103rd_st_plan_C_00_DETAIL_779-06-C902_2016-07-14.pdf
PDF 416 KB Posted
- Attached to
- FY16 Underwood Creek Ecosystem Restoration
- Solicitation number
- W911XK-16-B-0012
About this file
103rd Street Plans
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BOX CULVERT
4’x8’ PRECAST CONCRETE
8’ 4
TYPICAL SECTION 8
BETWEEN CROWNS
APPROX. 0.04’ GAP
TURF GRASS
FILTER FABRIC
LANDSCAPE CONTRACTOR SHALL ESTABLISH VIGOROUS GROWTH AND
MOW & MAINTAIN AS DESCRIBED IN WRITTEN SPECIFICATION.
TOPSOIL PER SPECIFICATIONS
NTS
NTS
NTS
NTS
CONCRETE END SECTION DETAIL
FRONT
SIDE
6"
MIN. 3000 PSI CONCRETE
CONNECTION
CONCRETE COLLAR
4’ MIN
TYP.
8" MIN
TOPSOIL REPLACEMENT DETAIL
@ 0.0218’/’
CULVERT
EXIST. BOX
@ 0.0 300’/’
CULVERT
PROP. BOX
@ 4" O.C.
6#5 HOOPS
DOWELS
MATCHING
#5 @ 8" WITH
1’-0"
#5 @ 12" O.C.
7#5
3#5
SIDE
4#5 EACH
9’-0" 1’-0"
CULVERT
4’x8’ BOX
CULVERT
4’x8’ BOX
3#5
#4 @ 8" O.C.
2’-6"
3#5
#4 @ 8" O.C.
3%
TOP
PLANS
SEE USACE
RETAINING WALL
9’-2" 1’-10"1’-2"6"
#3 STIRRUPS @ 8" O.C.
10"
#3 @ 8" O.C.
4#5
2#5
#4 @ 8" O.C.
1’-0" 1’-0"1’-0"1’-0" 8’-0"
1’-0"1’-0"
NOTES:
NOTES:
1.
2.
3.
4. SEE PLANTING PLAN IN USACE PLANS FOR LOCATION OF VARIOUS SEED MIXES.
NOTES:
C902
#5 @ 12" O.C.
#5 @ 8" O.C.
#5 @ 8" O.C.
#5 @ 12" O.C.
#5 @ 8" O.C.
#5 @ 12" O.C.
#5 @ 12" O.C.
#5 @ 8" O.C.
#5 @ 8" O.C.
KEY
#5 @ 12" O.C.
O.C.
#5 @ 8"
KEY
NTS
JOINT PREPARATION
SEE SPECIFICATIONS FOR
CONSTRUCTION JOINT,
AS DETAILED
REINFORCEMENT
SEE DETAIL
WATERSTOP,
6" PLASTIC
NOTE:
A
AT OUTSIDE
THICKNESS
C - MIN STEM
OUTSIDE DIA
D - CENTER BULB
THICKNESS
E - MIN BULB
TYP
5/32"
ALL RIBS, TYP
1/8" PROJECTION
FACE OF WS
EA SIDE, EA
F - NO OF RIBS
1.
2.
3.
4.
NOTES:
NTS
PLASTIC WATERSTOP
USACE PLANS
WALL, SEE
RETAINING
MATERIAL QUALITY PER SPECIFICATIONS
DIM REQUIREMENTS INDICATED SHOULD BE GIVEN
TO SUPPLIERS PRIOR TO PLACING ORDERS
NON-ROUND CENTER BULBS SHALL HAVE A MIN OUTSIDE DIM OF D
6"x3/8" WS TO BE USED IF NOT OTHERWISE INDICATED
@ CTR BULB
MIN STEM THICKNESS - B
9"x3/8"
6"x3/8"
4"x3/16"
SIZE
9"
6"
4"
A
3/8"
3/8"
3/16"
B
3/8"
3/8"
3/16"
C
1"
7/8"
3/4"
D
1/4"
1/4"
1/4"
E
F
PLANS
SLOPE PER
ELEVATION
TOP OF WALL
MATCH USACE
ON END SECTION DETAIL
PROVIDE KEYS WHERE SHOWN
SPECIFICATIONS
TOPSOIL SHALL CONFORM TO PROPERTIES AS DESCRIBED IN
SPECIFICATIONS
SEED BLEND & APPLICATION PROCEDURES ARE DESCRIBED IN
CONCRETE COLLAR
1.
6"
BASE BELOW
4.
3.
2.
1.
GROOVE
" SAW CUT4
3"x4
SEE NOTE 4
3" (TYP.)
(TYP.)
3"SEE NOTE 4
REV. NO. DATE REVISION DESCRIPTION BY APVD
APVD
CHK
DR
DSGN This Design Prepared For MMSD By:
BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY.
0" 1"
VERIFY SCALES MILWAUKEE METROPOLITAN SEWERAGE DISTRICT
W01001C01
MMSD FILE:
CONTRACT:
DATE:
SHEET:
DRAWING NO.:
McCARTHY
METROPOLITAN SEWERAGE DISTRICT.
AUTHORIZATION OF THE MILWAUKEE
PROJECT WITHOUT THE WRITTEN
WHOLE OR IN PART, FOR ANY OTHER
SERVICE AND IS NOT TO BE USED, IN
AN INSTRUMENT OF PROFESSIONAL
DESIGNS INCORPORATED HEREIN IS
THIS DOCUMENT AND THE IDEAS AND
REUSE OF DOCUMENTS
PARTNERS FOR A CLEANER ENVIRONMENT
UNDERWOOD CREEK
WATERCOURSE
JULY 15, 2016
103RD STREET OUTFALL DETAILS
TECCA
KURTZ
HENK
30’0 10’ 20’-30’ -20’ -10’
CROSS SECTION @ STATION 11+00.00
VERT. 1"=2’
HORZ. 1"=10’
-40’ 40’
30’0 10’ 20’-30’ -20’ -10’-40’ 40’
686686
GROUND
EXISTING
CROSS SECTION @ STATION 11+40.00
SWALE
TOPSOIL
P/L P/L
LINE
REFERENCE
CULVERT PIPE
CONCRETE BOX
PROPOSED 4’x8’
AND BEDDING
CONCRETE CHANNEL
REMOVE EXISTING
MATERIAL
BEDDING
VERT. 1"=2’
HORZ. 1"=10’
30’0 10’ 20’-30’ -20’ -10’-40’ 40’
30’0 10’ 20’-30’ -20’ -10’-40’ 40’
5.5’
C /L S
W A
L E
TO BE REMOVED
RETAINING WALL
DECORATIVE STONE
(APPROX. LOCATION)
WALL TO REMAIN
STONE RETAINING
DECORATIVE
EXISTING SLOPES
APPROXIMATE 4:1
IN FILTER FABRIC
WASHED STONE WRAPPED
LINE, TYP.
PROPERTY
GROUND AT
MATCH EXISTING
ON INSIDE OF PIPES.
FORM A SMOOTH BEND
SEE NOTE 4
TOPSOIL
SEE SPECIFICATIONS
GRANULAR TRENCH BACKFILL,
SEE SPECIFICIATIONS
BEDDING MATERIAL,
SEE NOTE 4
TYPICAL CONSTRUCTION JOINT DETAIL SEE DETAIL (TYP.)
AT ALL CONSTRUCTION JOINTS,
WATER STOPS TO BE PLACED
JOINT.
(GUN GRADE) ALONG
ELASOMETRIC SEALANT
SECTION. USE
CULVERT AND END
BETWEEN BOX
INSTALL DOWEL BARS
CONTRACTOR SHALL
JOINTS.
CAST-IN-PLACE
INSTALLED AT
WATERSTOPS TO BE
OF WAUWATOSA.
BY THE VILLAGE
GRATE PROVIDE
SHALL INSTALL
CONTRACTOR
SPECIFICATIONS.
BY THE
AS INDICATED
DRAWINGS
PROVIDE SHOP
SPECIFICATIONS
BACKFILL, SEE
GRANULAR TRENCH
CULVERT PIPE
CONCRETE BOX
PROPOSED 4’x8’
AND BEDDING
CONCRETE CHANNEL
REMOVE EXISTING
MATERIAL
BEDDING
GROUND
EXISTING
TO BE REMOVED
RETAINING WALL
DECORATIVE STONE
AT STA 11+45
CLAY DAM
2-FOOT THICK
TOPSOIL
5.5’
C /L S
W A
L E
(APPROX. LOCATION)
WALL TO REMAIN
STONE RETAINING
DECORATIVE
EXISTING SLOPES
APPROXIMATE 4:1
P/L
LINE
REFERENCE
P/L
LINE, TYP.
PROPERTY
GROUND AT
MATCH EXISTING
SWALE
File details come from the government source that posted it. Updated .