G-0010 fi
ISSUE DATE:
of Engineers
US Army Corps
AND APPROVAL OF ALL DRAWINGS LISTED ON THE INDEX SHEET.
SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION
SUBMITTED BY:
SECTION CHIEF
APPROVAL RECOMMENDED BY:
BRANCH CHIEF
APPROVED BY:
CONSTRUCTION DIVISION
CHIEF, ENGINEERING AND
DATE
DATE
DATE
THEIR EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.
APPEAR ON THESE PROJECT DOCUMENTS WITHIN THE SCOPE OF
DESIGNATIONS OF U.S. ARMY CORPS OF ENGINEERS INDIVIDUALS
THIS SHEET. THE INITIALS OR SIGNATURES AND REGISTRATION
U.S. ARMY CORPS OF ENGINEERS AND THE A/E FIRMS IDENTIFIED ON
THIS PROJECT WAS DESIGNED BY THE PITTSBURGH DISTRICT OF THE
Pittsburgh District
C O
V E
R S
H E
E T
LOCATION
PROJECT
NTS
PROJECT VICINITY MAP
NTS
PROJECT LOCATION MAP
W911WN-17-X-XXXX
W911WN-17-B-8007
B
B A
K E
R
CONTRACT NO:
SOLICITATION NO:
J F
A R
M E
R
S
M
IS
S E
N D
A
LOCATION
PROJECT
CERTIFIED FINAL DOCUMENTS
JULY 2017
/s J E
S S
IC
A C F
A R
M E
R P .E
J
U L
Y
/s/ JESSICA C. FARMER, P.E. 14 JULY 2017
/s/ BETH L. SCHNELLER, P.E. 14 JULY 2017
/s/ JEANINE M. HOEY, P.E. 14 JULY 2017
BLAIRSVILLE, INDIANA COUNTY PA
CULVERT REPAIR PROJECT
PERMANENT EMBANKMENT AND
CONEMAUGH RIVER LAKE
ALLEGHENY RIVER BASIN
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
G -0
.d g n
-J
U L -2
:0
0.083334:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S I
D
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8 www.pa1call.org
PENNSYLVANIA ONE CALL SYSTEM, INC.
1-800-242-1776 or 8-1-1
CALL 3 BUSINESS DAYS BEFORE YOU DIG!
POCS Serial NO.:
Date:
LEGEND:
ZONE A - 100 YEAR FLOOD PLAIN BOUNDARY
(ABD)
EDGE OF WATER SURFACE
FENCE LINE
EXISTING OVERHEAD ELECTRIC LINE
EXISTING UNDERGROUND ELECTRIC LINE
EXISTING STORM SEWER LINE
EXISTING NATURAL GAS LINE
EXISTING WATER LINE
PIPING ABANDONED IN-PLACE
(FORCE)
EXISTING SANITARY SEWER FORCE MAIN
EXISTING SANITARY SEWER GRAVITY LINE
S
G
CO
SANITARY SEWER MANHOLE
STORM INLET
GAS METER
SANITARY SEWER CLEAN-OUT
UTILITY POLE
UTILITY POLE GUY WIRE
VALVE
BORING LOCATIONS/NUMBER
CONTRACTOR WORK LIMITS
LIMITS OF DISTURBANCE
PROPERTY LINE
LEGAL RIGHT-OF-WAY LINE
NEW STORM SEWER LINE
ST NEW 5’ DIAMETER STORM SEWER MANHOLE
990 MAJOR CONTOUR (PROPOSED)
MAJOR CONTOUR (EXISTING)
2GEOTEXTILEGT
UNLESS NOTEDUN
CENTRIFUGALLY CAST CONCRETE PIPECCCP
DIAMETERD
PUMPED WATER FILTER BAGPWFB
ROCK CONSTRUCTION ENTRANCERCE
BEST MANAGEMENT PRACTICEBMP
COMPOST FILTER SOCKCFS
WITHW/
HIGHWAY AND TRANSPORTATION OFFICIALS
AMERICAN ASSOCIATION OF STATE AASHTO
IDENTIFICATION ID
HIGH DENSITY POLYETHYLENEHDPE
POLYVINYL CHLORIDEPVC
CORRUGATED METAL PIPECMP
ROOMRM
GENERATORGEN
MANHOLEMH
INVERTINV
TOP GRATETG
APPROXIMATEAPPROX
ABANDONEDABD
HOUSEHSE
CONTROLCTR
CENTERLINEC
EQUALEQ
EACHEA
CONTRACTOR WORK LIMITSCWL
CUBIC YARDCY
CONCRETECONC
CENTER TO CENTERC/C
TYPICALTYP
MINIMUMMIN
MAXIMUMMAX
REQUIREDREQ’D
DRAWING(S)DWGS(S)
TOP OFT/
ELEVATIONEL
STATIONSTA
NOT TO SCALENTS
U.S. ARMY CORPS OF ENGINEERSUSACE
ABBREVIATIONS:
TREE
AND NEW STORM SEWER RIPRAP APRON
SULPHUR RUN BANK STABILIZATION AREA
AREA OF RIPRAP EMBANKMENT PROTECTION
EMBANKMENT CREST FILL AREAEMBANKMENT CREST FILL AREA
EXISTING VEGETATION LINE
S
M
IS
S E
N D
A
DRAWINGSREFERENCE
NAMEFILE TITLEDRAWING
PLATE_01-B
PLATE_02-A CONDITIONS EMBANKMENT PROPOSED &EXISTING
PLATE_03-B
VIEW PLANBERM
STABILIZATION TEMPORARY OF FOOTPRINT AND PLAN CONTROL SEDIMENT ANDEROSION
PLATE_04-A
ABBREVIATIONS AND NOTESMAINTENANCE
AND INSTALLATION PRACTICE MANAGEMENT BEST PLAN CONTROL SEDIMENTATION &EROSION
1FIG 1952-1963 HYDROGRAPHS STAGEPOOL
2FIG 1964-1975 HYDROGRAPHS STAGEPOOL
3FIG 1976-1987 HYDROGRAPHS STAGEPOOL
4FIG 1988-1999 HYDROGRAPHS STAGEPOOL
5FIG 2000-2011 HYDROGRAPHS STAGEPOOL
6FIG 2012-2016 HYDROGRAPHS STAGEPOOL
7FIG CONSTRUCTION BERM STABILIZATION TEMPORARY - DETAILSMISCELLANEOUS
R
A W
IN
G I
N D
E X
S
M
IS
S E
N D
A
B
B A
K
G-0011
O
N T
R A
C T A
N D R
E F
E R
E N
C E
J F
A R
M E
R
/s J E
S S
IC
A C F
A R
M E
R P .E
J
U L
Y
EXISTING CONDITIONS, SLOPE AREA FAILURE PLAN VIEW
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
G -0
.d g n
-J
U L -2
:0
0.083334:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
DRAWINGSCONTRACT
NAMEFILE
NO.
ID
SHEET
TITLEDRAWING
GENERAL
AO38ab_100_G-0010 G-0010 SHEETCOVER
AO38ab_100_G-0011 G-0011 INDEX DRAWING REFERENCE ANDCONTRACT
AO38ab_100_G-1012 G-0012 VIEW PLAN CONDITIONSEXISTING
AO38ab_100_G-1013 G-0013 PLAN LIMITS WORKCONTRACTOR
SURVEY
AO38ab_204_V-1001 V-1001 PLAN CONTROLSURVEY
CIVIL
AO38ab_204_C-0010 C-0010 SEQUENCECONSTRUCTION
AO38ab_204_C-1011 C-1011 PLAN LAYOUTPROPOSED
AO38ab_204_C-4012 C-4012 SECTION AND PLAN LINING AND REPLACEMENTCULVERT
C-5013
AO38ab_204_C-5014 C-5014
AO38ab_204_C-5015 C-5015
C-5016
C-3017
AO38ab_204_C-5018 C-5018
CONTROL SEDIMENTATION ANDEROSION
AO38ab_886_X-1001 X-1001 PLAN CONTROL SEDIMENT ANDEROSION
AO38ab_886_X-5002 X-5002 DETAILS PRACTICE MANAGEMENT BEST PLAN CONTROL SEDIMENT ANDEROSION
AO38ab_886_X-5003 X-5003 DETAILS PRACTICE MANAGEMENT BEST PLAN CONTROL SEDIMENT ANDEROSION
AO38ab_886_X-5004 X-5004 DETAILS PRACTICE MANAGEMENT BEST PLAN CONTROL SEDIMENT ANDEROSION
AO38ab_886_X-5005 X-5005 DETAILS PRACTICE MANAGEMENT BEST PLAN CONTROL SEDIMENT ANDEROSION
AO38ab_886_X-0006 X-0006 ABBREVIATIONS AND NOTES MAINTENANCE AND INSTALLATION PRACTICE MANAGEMENT BEST PLAN CONTROL SEDIMENT ANDEROSION
AO38ab_204_C-5013
AO38ab_204_C-5016
AO38ab_204_C-3017
NOT IN USE
EMBANKMENT REPAIR SECTIONS
C-5019AO38ab_204_C-5019
C-5020AO38ab_204_C-5020
C-5021AO38ab_204_C-5021
SULPHUR RUN BANK STABILIZATION DETAILS
CHAIN LINK SECURITY FENCE TYPE FE-5 DETAILS
EXISTING CONDITIONS CULVERT SECTIONS
CULVERT REPAIR DETAILS - SHEET 1 OF 2
CULVERT REPAIR DETAILS - SHEET 2 OF 2
HEADWALL DETAILS - SHEET 1 OF 2
HEADWALL DETAILS - SHEET 2 OF 2
G
C U
LVER
T (S
U
LP
H U R R
U N
ACCESS ROAD
TEMPORARY
EXISTING
AASHTO NO. 1 STONE
S
S
S
S
S
10+0
S
SEE NOTE 12
SEE NOTE 13
SEE NOTE 11
TREE
DEAD
S
S
G
CO
ZONE A - 100 YEAR FLOOD PLAIN BOUNDARY
(ABD)
MAJOR CONTOUR (EXISTING) - SEE NOTE 2
EDGE OF WATER SURFACE
FENCE LINE
EXISTING OVERHEAD ELECTRIC LINE
EXISTING UNDERGROUND ELECTRIC LINE
EXISTING STORM SEWER LINE
EXISTING NATURAL GAS LINE
EXISTING WATER LINE
PIPING ABANDONED IN-PLACE
SANITARY SEWER MANHOLE
STORM INLET
GAS METER
SANITARY SEWER CLEAN-OUT
UTILITY POLE
UTILITY POLE GUY WIRE
VALVE
(FORCE)
EXISTING SANITARY SEWER FORCE MAIN
EXISTING SANITARY SEWER GRAVITY LINE
S
S
CO
S
S
ZONE A - 100 YEAR
FLOODPLAIN BOUNDARY
SEE NOTE 1
SCALE: 1" - 20’
PLAN - EXISTING CONDITIONS
SEE NOTE 5
SEE NOTE 2
(APPROX 20’ x 40’)
STEEL PLATE
S U L P
H U
R R
U N
F L O
W
(APPROX)
STREAM BANK
TOP OF EXISTING
ENTRANCE
CONSTRUCTION
EXISTING ROCK
CULVERT
BRICK ARCH
POST
FENCE
(APPROX 12" DIA)
PIPE IN HEADWALL
EXISTING STEEL
LAYDOWN AREA
CONTRACTOR
EXISTING
APRON
CONCRETE
SEE NOTE 8
SEE NOTE 9
SEE NOTE 10
SEE NOTE 6
BORING LOCATIONS/NUMBER
EXISTING VEGETATION LINE
HEADWALL
CONCRETE
EXISTING
TO BE REMOVED
NOTES:
TB-1
TB-2
TB-3
INFORMATION.
APPROXIMATELY 30 FT ALONG CULVERT. SEE SHEET C-4012 FOR ADDITIONAL
EXISTING STRUCTURAL PLATE ARCH CULVERT. STRUCTURAL PLATE EXTENDS13.
INLETS, TIRES ETC.) THAT SHALL BE REMOVED AND DISPOSED OF.
DOWNSTREAM CHANNEL AND SIDE SLOPES CONTAIN LARGE DEBRIS (ROCK, SEWER12.
COVERED WITH SILTY SAND.
AREA HAS BEEN SUBJECT TO EROSION OF FINES FROM HILLSIDE. AGGREGATE IS11.
MANHOLE 102 IS LOCATED WITHIN THE EXISTING STONE ARCH CULVERT.10.
AT THE CONCLUSION OF THE CONTRACT.
NORTH SPRING STREET. SANDBAGS SHALL BE REMOVED AND STORED FOR REUSE
DISPOSED. STORM WATER RUNOFF IS CONTROLLED BY SANDBAG DIKES ALONG
EXPOSED SLOPE COVERED BY GEOTEXTILE. GEOTEXTILE TO BE REMOVED AND 9.
LOCATED DOWNHILL AS SHOWN AND SHALL BE REMOVED PRIOR TO CONSTRUCTION.
CURB HAS BEEN REMOVED IN THIS AREA DUE TO UTILITY WORK. A DEAD TREE IS
SURFACE EROSION OBSERVED IN THIS AREA DUE TO CHANNELING OF RUNOFF.8.
SPECIFICATIONS.
VIDEO CONDUIT INSPECTIONS ARE PROVIDED IN THE ATTACHMENTS TO
PRECIPITATION, LAKE LEVELS AT CONEMAUGH DAM, EXISTING UTILITIES, AND
INFORMATION PERTAINING TO GEOTECHNICAL CONDITIONS, HISTORICAL 7.
INTO NEW ARCH CULVERT.
AND IS APPROXIMATELY 3’x4’x4’. CONTRACTOR SHALL INCORPORATE MANHOLE
SANITARY MANHOLE 101 IS LOCATED INSIDE THE EXISTING STRUCTURAL PLATE6.
ATTACHMENTS TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.
APPROXIMATELY 7 FEET DOWNSTREAM OF THE STONE/BRICK TRANSITION. SEE
A STEEL PIPE IS ENTERING THE CROWN OF THE STONE ARCH CULVERT5.
SECTION 01 18 00.
ALL UTILITIES SHALL BE CONFIRMED IN ACCORDANCE WITH SPECIFICATION
EXISTING UTILITIES LOCATIONS PROVIDED BY THE BOROUGH OF BLAIRSVILLE.4.
INTERVALS.
AND LABELED WITH THE ELEVATION; MINOR CONTOURS ARE SHOWN AT 2-FOOT
MAJOR CONTOURS ARE SHOWN ON THIS DRAWING AT INTERVALS OF 10 FEET3.
ADDITIONAL INFORMATION.
BLOCKS TO BRIDGE THE CULVERT. SEE REFERENCE DRAWING (FIGURE 7) FOR
THE EXISTING CULVERT. A SERIES OF WELDED PLATES WERE ANCHORED TO THE
2’X2’6’ JUMBO BLOCKS KEYED TOGETHER TO FORM SUPPORT OUTSIDE OF
SUPPORT BLOCKS FOR TEMPORARY STABILIZATION MEASURES CONSIST OF2.
DRAWING (PLATE 2A) FOR SCHEMATIC CROSS-SECTION OF REPAIR.
PLACED AS SHOWN AT THE TOE OF THE FAILURE SURFACE. SEE REFERENCE
TEMPORARY STABILIZATION PERFORMED IN SPRING 2017 ROCK BERM (PA DOT R-4)1.
INV OUT: 971.68
INV IN: 972.05
INV IN: 972.05
RIM: 981.70
MH-3
INV OUT: 972.48
INV IN: 972.63
INV IN: 974.19
RIM: 983.29
MH-4
INV OUT: 973.13
INV IN: 973.24
RIM: 982.88
MH-5
INV OUT: 968.33
INV IN: 968.42
RIM: 977.02
MH-2
BY-PASS
" P
LASTIC
" C
MP
12" (ABD)
(A B
D )(A
B D ) 3
" P
L A
S T
IC
INLET
INV OUT: 978.31
INV IN: 978.31
TG: 981.91
INLET
INV: 978.01
TG: 981.61
INLET
18" TILE
" C
M P
" P
L A
S T
IC
" P
V C
6" P
VC
3/4" WL AND 2" GL
(A B
D
ANTENNA TOWER
(F O
R C E
RIM: 947.81
MH-102
RIM: 947.8
MH-10121
" P
VC
INV: 947.18
INV OUT: 947.71
RIM: 957.37
MH
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
GENERATOR
RM
GEN
HSE
CTRL
STATION
PUMP
CONC WALL
SHED
N
CENTER STREET
N O
R T
H S
P R
IN
G S
T R
E E
T
DRIVEWAY (ASPHALT)
P E N
N S
T R E E T
SHEET ID
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
40’ G-1012
X
IS
T
IN
G C
O N
D
IT
IO
N S
P L
A N V
IE
W
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
20’
SCALE: 1"=20’
S
IZ
E
S U
B M
IT
T E
D B
Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
F
IL
E N
A M
E
P L
O T D
A T
E
A O a b
G -1
.d g n
-J
U L -2
:0
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
CERTIFIED FINAL DOCUMENTS
B
B A
K E
R
S
M
IS
S E
N D
A
J F
A R
M E
R
/s J E
S S
IC
A C F
A R
M E
R P .E
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
C O
N T
R A
C T N
O
IS
S
U E D
A T
E
W
W N -1
-B -8
J
U L
Y
D A
T of Engineers
US Army Corps
10987654
20.00004:1H4TSDBAC
A
B
C
D
E
F
G
ACCESS ROAD
TEMPORARY
EXISTING
STONE
AASHTO NO. 1
SANDBAGS
APPROXIMATE AREA OF EROSION
PROTECTION
AREA OF RIPRAP EMBANKMENT
EXISTING TREE (SINGLE)
RIM: 964.39
MH
CONTRACTOR WORK LIMITS
POINT NO. NORTHING EASTING
405135.89
405134.53
1546156.78405063.05
405020.65 1546133.31
1546143.49404935.70
404923.30 1546128.73
1546117.67404882.18
404861.26 1546125.18
404853.53 1546167.93
1546197.61404845.56
404844.58 1546214.52
1546237.98404852.73
404871.89 1546258.07
1546314.60404936.97
404942.61 1546318.64
404979.44 1546384.64
1546408.24404980.90
405041.46 1546404.51
1546423.96405051.89
405089.05 1546472.30
1546465.67405098.03
405077.79 1546438.39
1546403.55405057.0228
1 1546398.68
1546376.70
18 404945.29 1546364.36
404932.54 1546365.01
404933.67 1546386.98
404839.46 1546164.04
404831.27 1546193.66
C U
LVER
T (S
U
LP
H U R R
U N
EX. STEEL PLATE
10+0
CULVERT
STONE ARCH
S U L P
H U
R R
U N
F L O
W
CONTRACTOR WORK LIMITS
(APPROX)
STREAM BANK
TOP OF EXISTING
ZONE A - 100 YEAR FLOOD PLAIN BOUNDARY
ZONE A - 100 YEAR
FLOODPLAIN BOUNDERY
LIMITS OF DISTURBANCE
ENTRANCE
CONSTRUCTION
EXISTING ROCK
CULVERT
BRICK ARCH
SCALE: 1" - 20’
PLAN - CONTRACTOR WORK LIMITS
SEE NOTE 1
PROPERTY LINE
LEGAL RIGHT-OF-WAY LINE
21 22
REPRESENT EXISTING FEATURES.
ITEMS CALLED OUT IN ITALICS AND/OR DISPLAYED IN GRAYSCALE2.
WITHIN THE EXISTING CULVERT.
SPRING STREET SHALL BE CONSTRAINED TO UNDERGROUND
WORK UPSTREAM OF THE LEGAL RIGHT-OF-WAY LINE FOR NORTH1.
NOTES:DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
GENERATOR
RM
GEN
HSE
CTRL
STATION
PUMP
CONC WALL
SHED
N
CENTER STREET
N O
R T
H S
P R
IN
G S
T R
E E
T
DRIVEWAY (ASPHALT)
L E
G A
L R
IG
H T -O
F -W
A Y
L E
G A
L R
IG
H T -O
F -W
A Y
L E
G A
L R
IG
H T -O
F -W
A Y
Z=1000.00
X=1546196.75
Y=404832.08
SHEET ID
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
20’ 40’
SCALE: 1"=20’
G-1013
N T
R A
C T
O R W
O R
K L
IM
IT
S
P L
A N
S
IZ
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
CERTIFIED FINAL DOCUMENTS
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S U
B M
IT
T E
D B
Y
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
F
IL
E N
A M
E
P L
O T D
A T
E
A O a b
G -1
.d g n
-J
U L -2
:0
W
W N -1
-B -8
B
C R
A T
Y
J
R U
S N
K
M A
R T
IN
/s J
A M
E S T S
H
IB
A T
A P .E
J
U L
Y
T
1098765
20.00004:1
A
H4TSDBAC
B
C
D
E
F
G
HSE
CTRL
POST
FENCE
MH-NSP-100
GEN RM
STA 0+81.80
TOWER
ANTENNA
(DESTROYED)
STA 1+69.12
N
PLAN - SURVEY CONTROL
SCALE: 1" = 40’
CENTER STREET
G A
T E
STATION
PUMP
D R
IV
E
C O
N C
DRIVEWAY
ASPHALT
G A
T E
M
IN
WALL
CONC
GEN
SHED
R P
R
IC
E
40’ 80’0
SCALE: 1"=40’
LEGEND:
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
D W
E L L
IN
G F
R A
M
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
D W
E L L
IN
G F
R A
W
E
LL
IN
G
F R
A
N
R T
H S
P R
IN
G S
T R
E E
T
A C
C E S S R
O A
D C C
U L V
E R
T
L
L
A C
C E
S S
R O
A D
948A-F
F-980-C
QUARRY
CREEK
GEOSPATIAL SECTION.
6. FILED DATA WAS COLLECTED IN JANUARY, MARCH, AND MAY OF 2017 BY USACE PITTSBURGH
5. THE AVERAGE COMBINED SCALE FACTOR (PA SOUTH ZONE) FOR THE PROJECT IS 0.99991766.
THE EXISTING BOROUGH OF BLAIRSVILLE MAPPING TO NAVD88.
4. THE EXISTING DROP MANHOLE NSP-100 WAS USED AS THE REFERENCE POINT TO LOWER
SINCE BEEN DESTROYED.
SURVEYORS AND USED TO MOVE MAPPING TO THE SPCS. STA 1+69.12 HAS
STA 0+81.80 AND 1+69.12, BOTH 5/8� REBAR, WERE RECOVERED AND OBSERVED BY USACE
HORIZONTAL COORDINATE SYSTEM AND AN ASSUMED VERTICAL DATUM. CONTROL POINTS
3. THE EXISTING MAPPING PROVIDED BY THE BOROUGH OF BLAIRSVILLE WAS ON AN ASSUMED
BASED ON GEOID12B.
2. THE VERTICAL DATUM IS NAVD88. THE ELEVATION UNITS ARE FEET. ALL GNSS ELEVATIONS ARE
CALCULATED BY NGS OPUS, AND CHECKED AGAINST NGS PID KX1056.
COORDINATES WERE DERIVED FROM A FIVE HOUR GNSS OCCUPATION OF 1001,
SPCS SOUTH ZONE (FIPS 3702). THE UNITS ARE US SURVEY FEET. THE NAD83(2011)
1. THE HORIZONTAL DATUM IS NAD83(2011). THE GRID COORDINATE SYSTEM IS PENNSYLVANIA
NOTES:
B
B A
K
V-1001
U
R V
E Y C
O N
T R
O L
P L
A N
R P
R
IC
E
J J
A L
B R
Z
IK
O W
S K I
J
U N
E
/s
B E
T H L S
C H
N E
L L E
R P .E
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
V -1
.d g n
-J
U L -2
:0
40.00008:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
S
F L O
W
S U L P
H U
R R
U N
EDGE OF WATER SURFACE
FENCE LINE
C CENTER LINE
PROPERTY LINE
CONTROLSURVEY
NAMESTATION NORTHINGGRID EASTINGGRID ELEVATION DESCRIPTION
QUARRY 405140.25 1546154.45 992.85
30" X 5/8" ON"QUARRY"
STAMPED DISKALUMINUM
CREEK 404656.11 1546073.89 940.09
"CREEK"
STAMPED DISKALUMINUM
1001 405130.83 1546345.15 983.67 NAIL
1002 405017.73 1546287.11 976.50 CONCRETE INSCRIBE
0+81.80STA 404897.78 1546126.61 945.43 REBAR5/8"
1+69.12STA 404939.43 1546203.33 --- DESTROYED
MH-NSP-100 --- --- 989.81 MANHOLE SEWERSANITARY
948A-F 405059.46 1546139.56 --- PIPE ON DISK BOUNDRYUSACE
F-980-C 404702.51 1546249.78 --- PIPE ON DISK BOUNDRYUSACE
IS
S
E N
C-0010
N S
T R
U C
T
IO
N S
E Q
U E
N
Y S
Z K
IE
W
IC
Z
J F
A R
M E
R
J
U L
Y
/s J E
S S
IC
A C F
A R
M E
R P .E
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
C -0
.d g n
-J
U L -2
:0
0.083334:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
DISPOSED OF PROPERLY FOLLOWING THE BMP INSTALLATION NOTES.
FILTER SOCKS SHALL BE CUT OPEN AND THE WOODEN STAKES AND MESH SHALL BE REMOVED FROM THE SITE AND
ONCE THE SITE HAS BEEN STABILIZED AND REACHED A UNIFORM 70% PERENNIAL VEGETATIVE COVER, THE COMPOST25.
SHALL BE DISPOSED OF OFF-SITE AT AN APPROVED FACILITY.
TREES, BRUSH, EXCESS SOIL AND CONSTRUCTION WASTE FROM THE CONSTRUCTION AND DEMOLITION ACTIVITIES24.
USED TO CONSTRUCT CROSSING SHALL BE SPREAD ALONG TEMPORARY ACCESS ROAD.
TEMPORARY STREAM CROSSING SHALL BE REMOVED AND RESTORED TO EXISTING CONDITIONS AS SHOWN. STONE23.
BANKS.
INSTALL TEMPORARY EROSION CONTROL BLANKETS ON ALL SLOPES GREATER THAN 3:1 AND ALONG THE STREAM22.
SEED, FERTILIZE, LIME, AND MULCH AREAS THAT HAVE BEEN DISTURBED BY THE CONSTRUCTION ACTIVITY.21.
INSTALL NEW CHAIN LINK SECURITY FENCE.20.
(IF AWARDED) REMOVE FLOW DIVERSION STRUCTURES FOR EXTENDED BANK ARMORING.19.
(IF AWARDED) INSTALL EXTENDED BANK ARMORING.18.
(IF AWARDED) INSTALL FLOW DIVERSION STRUCTURES FOR EXTENDED BANK ARMORING.17.
REMOVE TEMPORARY INLETS AND TEMPORARY SLOPE PIPES.16.
REMOVE DOWNSTREAM ROCK FILTER, PIPE FLUME AND TEMPORARY UPSTREAM SANDBAG DAM.15.
INSTALL REQUIRED BANK ARMORING.14.
STONE IN ERODED AREA ALONG LEFT BANK.
COMPLETE CONSTRUCTION USING NEW R-4 MATERIAL FROM APPROVED SOURCES. PLACE R-4 OR OTHER APPROVED
ZONES. RE-USE STORED R-4 FROM TEMPORARY STABILIZATION BERM AS APPROVED BY THE CONTRACTING OFFICER
DRAWINGS, INCLUDING SAND BEDDING LAYER, ANCHOR TRENCHES, AND EMBANKMENT CREST AND TRANSITION
INSTALL GEOTEXTILE FABRIC AND ROCK FILL EMBANKMENT TO THE LINES AND GRADES SHOWN ON CONTRACT13.
PHASING OF THIS WORK.
INSTALL CCCP LINER AND UPSTREAM CUT-OFF-KEY. ALTER POSITIONING OF PIPE FLUME AS REQUIRED FOR LATERAL 12.
INSTALL STRUCTURE BACKFILL AND GEOTEXTILE SEPARATION LAYER AT CULVERT REPLACEMENT.11.
FORM AND POUR CONCRETE HEADWALL END TREATMENT FOR ARCH CULVERT EXTENSION.10.
INSTALL STRUCTURAL PLATE OVER FOOTERS FOR CULVERT REPLACEMENT AND EXTENSION SECTIONS.9.
WINGWALLS.
INSTALL FOOTERS FOR CULVERT REPLACEMENT AND EXTENSION SECTIONS AND CONCRETE HEADWALL AND8.
STABILIZATION BERM AT CONTRACTOR LAYDOWN AREA FOR RE-USE.
STABILIZATION BERM. REMOVE EXISTING CONCRETE HEADWALL AND WINGWALL. STORE R-4 FROM TEMPORARY
AND AFTER EXCAVATION. REMOVE AND DISPOSE OF STEEL PLATE AND CONCRETE BLOCKS FROM TEMPORARY
WITH THE PERMANENT EMBANKMENT MATERIAL. INSTALL SHORING, SHEETING, AND BRACING AS NEEDED DURING
A SEQUENCE SUCH THAT NO MORE MATERIAL THAN NECESSARY IS REMOVED AT ANY TIME PRIOR TO BACKFILLING
MENT MATERIAL TO THE LINES AND GRADES SHOWN IN THE CONTRACT DOCUMENTS. PERFORM THIS EXCAVATION IN
EXCAVATE TEMPORARY STABILIZATION FEATURES, MATERIAL FROM THE FAILED STONE ARCH CULVERT, AND EMBANK-7.
INSTALL PIPE FLUME, TEMPORARY UPSTREAM SANDBAG DAM, AND DOWNSTREAM ROCK FILTER.6.
BAGS AND R-5 RIPRAP AT TEMPORARY SLOPE PIPE DISCHARGES.
SANDBAG DIVERSION ALONG NORTH SPRING STREET, TEMPORARY INLETS, TEMPORARY SLOPE PIPES, INLET FILTER
INSTALL TEMPORARY STREAM CROSSING, COMPOST FILTER SOCKS, PERFORM CLEARING AND GRUBBING; INSTALL5.
PERFORM A VIDEO SURVEY OF THE EXISTING CULVERT.4.
SPACE WORK PLAN.
MONITORING TO ENSURE WORKER SAFETY WITHIN EXISTING CULVERT IN ACCORDANCE WITH APPROVED CONFINED
PROVIDE CONFINED SPACE PERMITS PRIOR TO ANY WORK WITH THE EXISTING CULVERT STRUCTURE. INITIATE3.
TO THE SITE.
REMOVE EXISTING FENCING AND INSTALL ANY TEMPORARY FENCES AND GATES AS REQUIRED TO RESTRICT ACCESS
FACILITIES TO BOROUGH PERSONNEL. COORDINATE WITH CONTRACTING OFFICER AND BOROUGH OF BLAIRSVILLE TO
COORDINATE WITH CONTRACTING OFFICER AND BOROUGH OF BLAIRSVILLE TO PROVIDE ACCESS TO PUMP STATION2.
VERIFY AND CLEARLY MARK ALL EXISTING UTILITIES WITHIN THE CONTRACTOR�S WORK LIMITS.1.
ANY MODIFICATIONS SHALL BE APPROVED BY THE CONTRACTING OFFICER.
ADHERING TO ALL DEFINED CONSTRUCTION RESTRICTIONS. IF THE CONTRACTOR ELECTS TO MODIFY THIS SEQUENCE, THE CONTRACTOR HAS THE ABILITY TO MODIFY THE SEQUENCE TO SUIT THEIR MEANS AND METHODS WHILE
THE PROPOSED CONSTRUCTION SEQUENCE PRESENTS ONE POSSIBLE METHOD OF PERFORMING THE WORK.
EMBANKMENT REPAIRS:
PROPOSED SEQUENCE OF WORK � BLAIRSVILLE PERMANENT
5’
G
C U
LVER
T (S
U
LP
H U R R
U N
SEE NOTE 7
SANDBAGS TO DIVERT FLOW (SEE NOTE 12)
(SEE NOTE 12)
SANDBAGS TO DIVERT FLOW
10+0
S
S
S
S
S
S
S
ZONE A - 100 YEAR FLOOD PLAIN BOUNDARY
990 MAJOR CONTOUR (EXISTING) - SEE NOTE 3
EDGE OF WATER SURFACE
MAJOR CONTOUR (PROPOSED) - SEE NOTE 3990
CONTRACTOR WORK LIMITS
AREA OF R-4 RIPRAP EMBANKMENT PROTECTION
SULPHUR RUN BANK STABILIZATION AREA
NEW CHAIN-LINK SECURITY FENCE
EMBANKMENT CREST FILL AREA
APPROXIMATE AREA OF EROSION GULLY
S
S
CO
S
S
S U L P
H U
R R
U N
F L O
W
ZONE A - 100 YEAR
FLOODPLAIN BOUNDARY
SEE DETAIL 1, SHEET C-5018
NEW CONCRETE HEADWALL
SCALE: 1" - 20’
PLAN - PROPOSED LAYOUT
AND NOTES
SHEET C-5021 FOR DETAILS
FENCE (APPROX 135 LF) - SEE
NEW CHAIN-LINK SECURITY
E X T E
N D
E D B
A N
K A
R M
O R
IN
G
(I N S T
A L L I F O
P T
IO
N I S A
W A
R D
E D
B A N
K A
R M
O R
IN
G
R E Q
U
IR
E D M
IN
IM
U
ARCH CULVERT
EXISTING BRICK
CONCRETE
END OF INLET WITH
PLUG DOWNSTREAM
DRIVEWAY APRON
EXISTING CONCRETE
EXISTING ASPHALT DRIVEWAY
DETAILS AND NOTES
SEE SHEET C-5020 FOR
ARMORING (R-5 STONE)
SULPHUR RUN BANK
SEE NOTE 8
INV EL 947.18
EXIST 21" PVC
SECTIONS, DETAILS AND NOTES
C-4012 THRU C-5015 FOR PLANS,
CULVERT REPAIRS - SEE SHEETS
FLOW DEPTH OF UP TO 6 INCHES.
RUNNING BETWEEN ADJACENT BAGS. SANDBAGS SHALL BE ABLE TO DIVERT A
PLACED SUCH THAT ROWS ARE OFFSET TO PREVENT SURFACE FLOW FROM
ARE RE-USED, THEY SHALL BE FREE OF RIPS AND TEARS. SANDBAGS SHALL BE
STORED SANDBAGS AS APPROVED BY THE CONTRACTING OFFICER. IF SANDBAGS
CONTRACTOR TO INSTALL SANDBAGS AS SHOWN. CONTRACTOR MAY RE-USE12.
BEYOND EXTENTS OF WINGWALLS TO EFFECT DRAINAGE.
THE EMBANKMENT - SSP INTERFACE SHALL EXTEND A MINIMUM OF 2 FEET
EMBANKMENT ROCK FILL SHALL DIRECTLY CONTACT SSP FOR BANK ARMORING.11.
ENSURE ACCEPTABLE STABILITY.
EVENT, THE CONTRACTOR SHALL FLATTEN OR SHORE TEMPORARY SLOPES TO
DURING AND AFTER EXCAVATION. IN THE CASE OF AN IMPENDING HIGH WATER
FILLED. SHORING, SHEETING, AND BRACING SHALL BE INSTALLED AS NEEDED
PORTION OF THE SLOPE SHALL BE OPENED WHICH CANNOT BE QUICKLY BACK-
ARE OBSERVED FOLLOWING REMOVAL OF THE TEMPORARY STABILITY BERM, NO
FILLING WITH THE PERMANENT EMBANKMENT MATERIAL. IF SLOPE INSTABILITIES
MORE MATERIAL THAN NECESSARY IS REMOVED AT ANY TIME PRIOR TO BACK-
THE CONTRACTOR SHALL PERFORM EXCAVATIONS IN A SEQUENCE SUCH THAT NO10.
FOR ADDITIONAL REQUIREMENTS.
TO PROTECT WORKERS FROM HIGH FLOWS. SEE SPECIFICATION SECTION 01 35 00
THE EXISTING CULVERT. CONTRACTOR SHALL INSURE THAT A SYSTEM IS IN PLACE
THE CONTRACTOR SHALL TAKE SPECIAL PRECAUTIONS WHEN WORKING WITHIN 9.
CONTRACTING OFFICER.
CONTRACTOR TO PLACE R-4 IN SURFACE EROSION GULLIES AS DIRECTED BY 8.
INSTALLATION OF NEW HEADWALL.
EXISTING TREE ADJACENT TO HEADWALL TO BE REMOVED PRIOR TO 7.
FOR ADDITIONAL LEGEND SYMBOLS, SEE SHEET G-1012. 6.
SECTION 01 18 00.
ALL UTILITIES SHALL BE CONFIRMED IN ACCORDANCE WITH SPECIFICATION
EXISTING UTILITIES LOCATIONS PROVIDED BY THE BOROUGH OF BLAIRSVILLE. 5.
DOWNSTREAM SHALL BE PERFORMED IF OPTION IS AWARDED.
DETAILS AND NOTES. ADDITIONAL ARMORING INSTALLATION TO 170 FEET
DOWNSTREAM OF THE NEW CULVERT HEADWALL. SEE SHEET C-5020 FOR
MINIMUM BANK ARMORING TO BE PERFORMED TO APPROXIMATELY 50 FEET 4.
ALONG CENTER OF CULVERT. SEE SHEET C-3017 FOR ADDITIONAL DETAILS.
SEE SHEET C-4012 FOR TYPICAL CROSS SECTION FOR BUTTRESS CONSTRUCTION 3.
INTERVALS.
AND LABELED WITH THE ELEVATION; MINOR CONTOURS ARE SHOWN AT 2-FOOT
MAJOR CONTOURS ARE SHOWN ON THIS DRAWING AT INTERVALS OF 10 FEET 2.
PRIOR TO BEGINNING WORK.
SHALL VERIFY EXISTING CONDITIONS AND PERFORM SURVEY AS NECESSARY
AREA. SEE REFERENCE DRAWINGS FOR DESIGN SECTIONS. THE CONTRACTOR
EXISTING PAVEMENT HAS BEEN REMOVED ALONG NORTH SPRING STREET IN THIS
INSTALLATION OF TEMPORARY STABILIZATION MEASURES DURING SPRING 2017.
CONTOURS IN THE AREA OF FAILURE REPRESENT THE CONDITIONS AFTER 1.
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
DWELLING
FRAME
GENERATOR
RM
GEN
HSE
CTRL
STATION
PUMP
CONC WALL
SHED
B C-3017
A C-3017
SHEET ID
CENTER STREET
C-1011
N O
R T
H S
P R
IN
G S
T R
E E
T
P E N
N S
T R E E T
P R
O P
O S
E D L
A Y
O U
T
P L
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
20’ 40’
SCALE: 1"=20’
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
F
IL
E N
A M
E
P L
O T D
A T
E
A O a b
C -1
.d g n
-J
U L -2
:0
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S I
D
L
IB
E R
T Y A
V E
N U
E W
W N -1
-B -8
B
C R
A T
J
U L
Y
A
M A
R C
G U
Y
/s E
R
IC
H D
G U
Y P .E
D A
T
20.00004:1
A
B
H4TSDBAC
C
D
E
F
2’ (MIN)
20’
EX. STONE ARCH CULVERT- SEE DETAIL 1, SHEET C-5014
70’ (APPROX)
EXISTING STONE ARCH CULVERT LINING- SEE DETAIL 1, SHEET C-5014
70’ (APPROX)
EL 947.72
TOP FOOTER
SS
SEE DETAIL 1, SHEET C-5018
NEW CONCRETE HEADWALL
AASHTO #1
AASHTO #57
STONE
R-4
C-4012 NTS
DETAIL - EMBANKMENT CREST
SELECT GRANULAR FILL (2RC)
(SEE DETAIL 2, SHEET C-3017)
GEOTEXTILE WITH BEDDING
(SEE DETAIL 1, SHEET C-3017)
ANCHOR TRENCH
GEOTEXTILE
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
C -4
.d g n
-J
U L -2
:1
10.00002:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
C-4012
M A
R K
U M
C U
L V
E R
T R
E P
L A
C E
M E
N T A
N D L
IN
IN
G
P L
A N A
N D S
E C
T
IO
N
0 10’ 20’
SCALE: 1"=10’
B
C R
A T
T Y /B
B A
K E
R
J
U L
Y
E
G U
Y
/s E
R
IC
H D
G U
Y P .E
AND REPLACEMENT
FOR CULVERT REPAIRS
LIMITS OF EXCAVATION
1.75
(WINGWALL)
NEW HEADWALL
C NORTH SPRING STREET (APPROX)L
SHEET C-3017
GT - SEE DETAIL 1,
ANCHOR TRENCH FOR
GROUND
EXISTING
BACKFILL
STRUCTURE
ROCK FILL (R-4)
EMBANKMENT
SEE DETAIL 1, SHEET C-5018
NEW CULVERT HEADWALL
STA 2+91.09
CULVERT HEADWALL
FACE OF NEW
INFORMATION
SHEET, FOR ADDITIONAL
EL 980.5 - SEE DETAIL 1, THIS
NEW EMBANKMENT CREST AT
GT
EXTENTS
SHEET C-1011 FOR
STABILIZATION - SEE
R-5 STREAMBANK
(SEE DETAIL 2, SHEET C-3017)
LAYER (GT) WITH BEDDING
GEOTEXTILE SEPARATION
CONCRETE ENCASEMENT
SANITARY SEWER WITH
EXISTING 21" DIAMETER
EL 945.63
EL 947.14
947.81
EL T/EL
MH-102
EL. 947.72
TOP FOOTER
KEY - SEE DETAIL 6, SHEET C-5015
APPROXIMATE LOCATION OF UPSTREAM CUT-OFF
3+00 4+00
N
ENCASED IN CONCRETE
EXISTING 21" SANITARY SEWER
LC
C
U L
V E
R T S
E E N
O T
E
SCALE: 1" - 10’
PLAN - CULVERT LINING AND REPLACEMENT
FLOW
SULPHUR RUN
BOROUGH OF BLAIRSVILLE.
FINISHED PAVEMENT GRADE TO BE DETERMINED BY 2.
PAVEMENT LINE TO EDGE OF CREST.
5-FT SHOULDER ALLOWANCE FROM EDGE OF ORIGINAL 1.
NOTES:
FAILURE SURFACE
BEYOND EXISTING EMBANKMENT
EXISTING STONE ARCH CULVERT
SCALE: 1" = 10’
PROFILE - CULVERT LINING AND REPLACEMENT AND EMBANKMENT REPAIR
GROUND
EXISTING
TO REMAIN IN PLACE
EXISTING STRUCTURAL PLATE ARCH
LOCATION APPROXIMATE
SEE DETAILS C-5015
NEW CONCRETE FOOTERS
LOCATION APPROXIMATE
SEE DETAILS C-5015
NEW CONCRETE FOOTERS
NOTES:
PIPES ENTERING THE SYSTEM SHALL BE COVERED TO PREVENT LINING.
THE REQUIREMENTS OF 33 01 30.72. EXISTING SANITARY MANHOLES AND
FLOWABLE MORTAR. CCCP LINER AND FLOWABLE MORTAR SHALL MEET
LOCATED NEAR STA 4+20. FLOWLINE SHALL BE LINED WITH 4" - 6" OF A
FROM NEW HEADWALL TO TRANSITION OF STONE TO BRICK ARCH CULVERT
2. CULVERT SHALL BE LINED WITH CCCP LINER OR OTHER APPROVED MATERIAL
(STA 0+81.80) AND NO MONUMENT (DESTROYED) (STA 1+69.12).
SHOWN ON SURVEY CONTROL SHEET V-1001, SPECIFICALLY 5/8" REBAR1.
ARCH CULVERT
EXISTING STONE
2+40 2+304+30 4+20 4+10 4+00 3+90 3+80 3+70 3+403+60 3+50 3+30 3+20 3+10 3+00 2+90 2+80 2+70 2+60 2+50
T/EL 947.74
MH-101
EL 947.72
TOP FOOTER
NEW CCCP LINER
EL 943.50
T/ HEADWALL FOOTER
SEE DETAIL 2, SHEET C-5014
CULVERT REPLACEMENT -
20’ (APPROX)
SEE DETAIL 4, SHEET C-5015
CULVERT EXTENSION -
30’ (APPROX)
SEE DETAIL 2, SHEET C-5014
CULVERT REPLACEMENT -
20’ (APPROX)
SEE DETAIL 4, SHEET C-5015
CULVERT EXTENSION -
30’ (APPROX)
SEE DETAIL 3, SHEET C-5014
EXISTING STRUCTURAL PLATE ARCH -
30’ (APPROX)
SEE DETAIL 3, SHEET C-5014
EX. STRUCTURAL PLATE -
30’ (APPROX)
EL 947.72
T/FOOTER
EL 947.72
T/FOOTER
EL 947.72
T/FOOTER
EL 947.72
T/FOOTER EL 946.00
T/FOOTER
EL 946.00
T/FOOTER
EL 943.50
FOOTER
T/ HEADWALL
EL 943.50
FOOTER
T/ HEADWALL
EL 947.72
T/FOOTER
EL 947.72
T/FOOTER
3’-8" –
2" 5"
1’-0" 1’-0"
10’-0"
9’-8"
1’-0"
2" 3"
D E
P T
H U
N K
N O
W N
D E
P T
H U
N K
N O
W N
1’-0"
10’-4"
10’-0"
9’-4"
10’-7"
9’-9"
11’-1"
EL. 947.72 EL. 947.72
EL. 952.99
EL. 944.93
EL. 944.13
EL. 945.33
TOP EL. 947.74
EXISTING STRUCTURAL PLATE, CONCRETE, AND FLOWLINE SHALL BE LINED AS INDICATED ON DETAIL 3 ON C-5014.3.
EXISTING MANHOLE SHALL BE PROTECTED TO AVOID LINING TO PREVENT ACCESS ISSUES WITH MANHOLE.2
EXISTING CONCRETE HEADWALL TO BE REMOVED TO ACCOMMODATE ARCH CULVERT EXTENSION.1.
NOTES:
FLOOR
CULVERT
EXISTING
SEWER MANHOLE
EXISTING SANITARY
C CULVERTL
PLATE
STRUCTURAL
EXISTING
EL. 947.72
EL. 952.54
EL. 947.72
EL. 945.78
PLATE
STRUCTURAL
EXISTING
ENCASEMENT
WITH CONCRETE
SANITARY SEWER
EXISTING 21"
EL. 945.77
EL. 946.20
FLOOR
CULVERT
EXISTING
C CULVERTL
EL. 952.58
C CULVERTL
EL. 949.88
R = 5.38’
EL. 946.29
R = 8.78R = 9.81
EL. 947.38 EL. 947.38
ENCASEMENT
WITH CONCRETE
SANITARY SEWER
EXISTING 21"
EL. 946.27
EL. 947.88 EL. 947.88
EL. 949.88
CULVERT
STONE ARCH
EXISTING
FLOOR
CULVERT
EXISTING
C-5013 NTS
EXISTING STRUCTURAL PLATE LOOKING UPSTREAM STA 3+03.44 2
C-5013 NTS
EXISTING STRUCTURAL PLATE LOOKING UPSTREAM STA 3+31.44
C-5013 NTS
EXISTING STONE ARCH CULVERT LOOKING UPSTREAM STA 3+53.44
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
C -5
.d g n
-J
U L -2
:1
0.083334:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
C-5013
J
U L
Y
J F
R E
E M
A N
E
G U
Y
/s E
R
IC
H D
G U
Y P .E
B
B A
K E
R
E X
IS
T
IN
G C
O N
D
IT
IO
N S
C U
L V
E R
T S
E C
T
IO
– 3’-8"
– 3’-8"
L (PADOT CLASS 4 TYPE A)
GEOTEXTILE SEPARATION LAYER
DESCRIBED IN SPECIFICATIONS
PREPARE SURFACE AS
EXISTING CULVERT FLOOR,
C CULVERT
EL. VARIES
ENCASEMENT
WITH CONCRETE
SANITARY SEWER
EXISTING 21"
RISE = 6’-3"
SPAN = 12’-0"
R = 6’-0"
PLATE ARCH
NEW STRUCTURAL
AS NEEDED
REMOVE DEBRIS
CCCP
4"-6" INVERT REPAIR MORTAR
SHEET C-5015
SIDE) - SEE DETAIL 5,
FOOTER (TYP EACH
NEW CONCRETE
BACKFILL
STRUCTURE
MIN. 2’ THICK
C CULVERTL
ENCASEMENT
WITH CONCRETE
SANITARY SEWER
EXISTING 21"
FLOOR
CULVERT
EXISTING
AS NEEDED
REMOVE DEBRIS
CULVERT
STONE ARCH
EXISTING
CCCP
4"-6" INVERT REPAIR MORTAR
FLOOR
CULVERT
EXISTING
SEWER MANHOLE
EXISTING SANITARY
C CULVERTL
CCCP
4"-6" INVERT REPAIR MORTAR
MANHOLES WITH CCCP LINER
DO NOT LINE EXISTING
NEW STRUCTURAL PLATE SHALL BE LINED WITH A CCCP OR OTHER APPROVED ALTERNATIVE.3.
RECOMMENDATIONS UNLESS OTHERWISE NOTED. CONTRACTOR MAY SUBMIT ALTERNATIVES TO THE STRUCTURAL PLATE FOR APPROVAL.
2. MINIMUM THICKNESS FOR STRUCTURAL PLATE SHALL BE 8 GAUGE. THE STRUCTURAL PLATE SHALL BE INSTALLED PER THE MANUFACTURER’S
05 19 GEOTEXTILE.
CONTINUOUSLY BETWEEN THE STRUCTURE BACKFILL AND THE EMBANKMENT ROCK FILL. GEOTEXTILE FABRIC SHALL MEET THE REQUIREMENTS OF 31
SHALL MEET THE REQUIREMENTS OF 31 00 00 FOR EARTHWORK, SECTION 3.11.1.2 STRUCTURE BACKFILL. GEOTEXTILE FABRIC SHALL BE PLACED
1. STRUCTURE BACKFILL SHALL BE PLACED AND COMPACTED AS SHOWN AROUND ALL NEW ARCH CULVERT. STRUCTURE BACKFILL AND COMPACTION
NOTES:
NOTES:
30.72.
MORTAR MEETING THE REQUIREMENTS OF SECTION 33 01
BOTTOMLESS ARCH CULVERT WITH 4"-6" OF A FLOWABLE
4. CONTRACTOR SHALL LINE THE FLOWLINE/INVERT OF THE
LOCATIONS OF KNOWN PIPES.
FOR REFERENCE. SEE SHEET G-1012 FOR APPROXIMATE
SEE CONDUIT INSPECTION MEMORANDUM ATTACHMENT
WITH THE APPROPRIATE AUTHORITY/OWNER OF THE PIPE.
PIPES SHALL BE APPROVED BY USACE AND COORDINATED
ABANDON AS APPLICABLE. ANY EFFORTS TO ABANDON
A PLAN TO INCORPORATE THE PIPES INTO THE SYSTEM OR
CONTRACTOR SHALL FIELD LOCATE ALL PIPES AND SUBMIT
WORK AREA INSIDE THE CULVERT AND HEADWALL. THE
3. MULTIPLE PIPES CAN BE FOUND IN THE VICINITY OF THE
SHEET G-1012 FOR APPROXIMATE LOCATION.
CONTRACTOR SHALL FIELD-VERIFY THE LOCATION. SEE
ARCH CULVERT. EXACT DIMENSIONS ARE UNKNOWN. THE
LOCATED ALONG THE RIGHT DESCENDING BASE OF THE
2. AN EXISTING, CONCRETE-ENCASED 21" SANITARY SEWER IS
MEET THE REQUIREMENTS OF 33 01 30.72 08.
OTHERWISE NOTED. THICKNESS OF LINER MATERIAL SHALL
MANUFACTURER’S RECOMMENDATIONS UNLESS
THE LINER MATERIAL SHALL BE INSTALLED PER THE
SHALL MEET THE REQUIREMENTS OF SECTION 33 01 30.72.
OR OTHER APPROVED ALTERNATIVE. LINER MATERIAL
SHALL BE A CENTRIFUGALLY CAST CONCRETE PIPE (CCCP)
1. LINER MATERIAL FOR EXISTING STONE ARCH CULVERT
C-4012 NTS
STRUCTURAL PLATE ARCH FOR CULVERT REPLACEMENT
C-4012 NTS
CCCP LINER FOR EXISTING STONE ARCH CULVERT LINING
C-4012 NTS
CCCP LINER FOR EX. STRUCTURAL PLATE ARCH
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
C -5
.d g n
-J
U L -2
:1
0.083334:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
C-5014
B
C R
A T
T Y /B
B A
K E
R
C U
L V
E R
T R
E P
A
IR
D
E T
A
IL
S
J
U L
Y
J F
R E
E M
A N
E
G U
Y
/s E
R
IC
H D
G U
Y P .E
S H
E E
T O
F
(M
IN
(MIN)
8"
4"
24"
(M
IN
(MIN)
12"
1’-6"
L
(PADOT CLASS 4 TYPE A)
GEOTEXTILE SEPARATION LAYER
DESCRIBED IN SPECIFICATIONS
PREPARE SURFACE AS
EXISTING CULVERT FLOOR,
C CULVERT
EL. VARIES
AS NEEDED
REMOVE DEBRIS
RISE = 5’-3"
SPAN = 10’-0"
R = 5’-0"
PLATE ARCH
NEW STRUCTURAL CCCP
4"-6" INVERT REPAIR MORTAR
THIS SHEET
SIDE) - SEE DETAIL 5,
FOOTER (TYP EACH
NEW CONCRETE
BACKFILL
MIN. 2’ THICK STRUCTURE
MORTAR
4" - 6" FLOWABLE
OR TO BEDROCK
DEPTH = 18" (MIN)
FLOOR
CULVERT
EXISTING
FLOW
SULPHUR RUN
R = 6’
CULVERT REPLACEMENT
STRUCTURAL PLATE ARCH AT
R = 5’
AND STONE ARCH CULVERT
EX. STRUCTURAL PLATE ARCH
GROUT
NON-SHRINK
18" C/C
6" SHEAR PINS
CULVERT REPLACEMENT
STRUCTURAL PLATE ARCH AT
GROUT
NON-SHRINK
SHEAR PINS
AND STONE ARCH CULVERT
EX. STRUCTURAL PLATE ARCH
BRACING/FORMS
TEMPORARY
18"
OVERLAP EXISTING ARCHES MIN.
CULVERT REPLACEMENT SHALL
STRUCTURAL PLATE ARCH AT
KEYWAYGROUT
FLOOR
CULVERT
EXISTING
FOOTING
REINFORCED CONCRETE
PLATE
STRUCTURAL
DIMENSIONS ACCORDINGLY.
6. THE CONTRACTOR SHALL COORDINATE KEYWAY DIMENSIONS WITH THE MANUFACTURER AND REVISE
SLOT (SEE FOOTER DETAIL, THIS SHEET). GROUT SHALL MEET THE REQUIREMENTS OF 31 73 00.
THE CONNECTION OF THE STRUCTURAL PLATE TO THE FOOTING SHALL BE MADE BY A GROUTED KEYWAY/5.
PLACING.
STANDING WATER, SNOW, ICE, AND OTHER DELETERIOUS SUBSTANCES BEFORE START OF CONCRETE
SURFACES AGAINST WHICH CONCRETE IS TO BE PLACED MUST BE FREE OF DEBRIS, LOOSE MATERIAL,4.
MINIMUM THICKNESS OF FOOTERS SHALL BE 18 INCHES UNLESS OTHERWISE APPROVED.3.
BRIDGES.
FOOTERS SHALL BE MEET THE REQUIREMENTS OF THE AASHTO STANDARD SPECIFICATION FOR HIGHWAY2.
CAST-IN-PLACE CONCRETE.
THE FOOTERS SHALL BE CAST-IN-PLACE OR PRECAST CONCRETE MEETING THE REQUIREMENTS OF 03 30 001.
STRUCTURAL PLATE ARCH FOOTER NOTES:
C-4012 NTS
UPSTREAM CUT-OFF KEY
C-4012 NTS
STRUCTURAL PLATE ARCH FOR CULVERT EXTENSION
C-4012 NTS
CULVERT TRANSITION
C-5015
C-5014
C-4012 NTS
FOOTER DETAIL
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
C -5
.d g n
-J
U L -2
:1
0.083334:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
C R
A T
T Y /B
B A
K E
R
C U
L V
E R
T R
E P
A
IR
D
E T
A
IL
S
J
U L
Y
J F
R E
E M
A N
E
G U
Y
/s E
R
IC
H D
G U
Y P .E
C-5015
S H
E E
T O
(M
(MIN)
2’-0"
(M
IN
A
C-1011 SCALE: 1" = 10’
SECTION - EMBANKMENT REPAIR
B
C-1011 SCALE: 1" = 10’
SECTION - EMBANKMENT REPAIR
C-4012
C-3017 NTS
DETAIL - ANCHOR TRENCH (TYP)
C-4012
C-3017 NTS
DETAIL - GEOTEXTILE WITH BEDDING
D A
T E fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
G
D E
S C
R
IP
T
IO
N M
A R
K
E
F
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
S
IZ
E
S U
B M
IT
T E
D B
Y
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
F
IL
E N
A M
E
P L
O T D
A T
E
D
A O a b
C -3
.d g n
-J
U L -2
:1
A
N S
W
W N -1
-B -8
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
B
C
P
IT
T S
B U
R G
H D
IS
T R
IC
T
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
SHEET ID
A
H4TSDBAC 10.00002:1
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C
CERTIFIED FINAL DOCUMENTS
M A
R K
U M
0 10’ 20’
SCALE: 1"=10’
E M
B A
N K
M E
N T R
E P
A
IR
S
S E
C T
IO
N S
B
C R
A T
T Y
J
U L
Y
E
G U
Y
/s E
R
IC
H D
G U
Y P .E
C-3017
940 940
0+00 0+10 0+20 0+30 0+40 0+50 0+60 0+70 0+80 1+100+90 1+00
ASPHALT DRIVEWAY
EDGE OF EXISTING
GROUND
EXISTING
1.75
BACKFILL
STRUCTURE
EDGE OF STREAM
STABILIZATION (R-5)
STREAMBANK
(WINGWALL)
NEW HEADWALL
BACKFILL
STRUCTURE
ROCK FILL (R-4)
EMBANKMENT
INSTALLATION
FOR NEW HEADWALL
LIMITS OF EXCAVATION
TO DETAIL 1, THIS SHEET)
ANCHOR TRENCH (SIMILAR
(SEE DETAIL 2, THIS SHEET)
LAYER (GT) WITH BEDDING
GEOTEXTILE SEPARATION
SHEET
GT - SEE DETAIL 1, THIS
ANCHOR TRENCH FOR
1+30
0+00 0+10 0+20 0+30 0+40 0+50 0+60 0+70 0+80 1+100+90 1+00
STA 12+10.4 (APPROX)
NORTH SPRING STREET BASELINE
1.75
INSTALLATION
FOR NEW HEADWALL
LIMITS OF EXCAVATION BACKFILL
STRUCTURE
EDGE OF STREAM
STABILIZATION (R-5)
STREAMBANK
(WINGWALL)
NEW HEADWALL
BACKFILL
STRUCTURE
ROCK FILL (R-4)
EMBANKMENT
GROUND
EXISTING
(SEE DETAIL 2, THIS SHEET)
LAYER (GT) WITH BEDDING
GEOTEXTILE SEPARATION
1+20
DETAIL 1, SHEET C-4012
CREST EL 980.5 - SEE
T/NEW EMBANKMENT
SAND BEDDING SHALL MEET THE REQUIREMENTS OF 31 00 00 SECTION 3.12.5.1.
NOTES:
GROUND
EXISTING
1’ MIN FOR 2RC
2’ MIN FOR R-4
GRADE
FINISHED
(SEE DETAIL 2, THIS SHEET)
GEOTEXTILE WITH BEDDING
GRADE
6" BELOW
GEOTEXTILE
STOP
R-4 OR 2RC FILL
GROUND
EXISTING
GEOTEXTILE
R-4 FILL
SEE NOTE 1.
SAND BEDDING.
15’-8" ’-0
2’ -0
3’ -0
45°
(A P P R
O X
8’ -4 /4
(MIN)
2’-0"
(M
IN
(M
IN
(M
IN
15’-8"
(APPROX)
5’-10 1/4 " (A P
P R
O X
/4
(M
IN
2’-0"
(A P
P R
O X
/2
(APPROX)
8’-4 3/4 "
10’-0"
1’-6"
2’-0"
C O
V E
R
M
IN
C O
V E
R
M
IN
V A
R
IE
S
3’-0"
COVER
2" MIN
COVER
2" MIN
L A
P S
P L
IC
E
M
IN
COVER (TYP UN)
3" MIN
S
C CULVERTL
OUT INV EL 947.18
OVERFLOW PIPE
PVC SEWER
EXISTING 21" DIA
INV OUT 947.71
RIM ELEV 957.37
OVERFLOW MANHOLE
EXISTING SEWER
C CULVERTL
EL 943.50
T/FOOTER
THIS SHEET
AT 18" C/C - SEE DETAIL 2,
3/4" x 19" x 5" HOOK BOLTS
FORM WINGWALL AROUND PIPE
COMPRESSIBLE FILL MATERIAL.
BETWEEN PIPES WITH
OVERFLOW PIPE; FILL VOID
WRAP AROUND EXISTING SEWER
SPLIT 24" DIA PVC PIPE AND
RIM ELEV 957.37
OVERFLOW MANHOLE
EXISTING SEWER
OVERFLOW PIPE
PVC SEWER
EXISTING 21" DIA
EL 943.50
T/FOOTER
RIM ELEV 957.37
OVERFLOW MANHOLE
EXISTING SEWER
OVERFLOW PIPE
PVC SEWER
EXISTING 21" DIA
FORM WINGWALL AROUND PIPE
COMPRESSIBLE FILL MATERIAL.
BETWEEN PIPES WITH
OVERFLOW PIPE; FILL VOID
WRAP AROUND EXISTING SEWER
SPLIT 24" DIA PVC PIPE AND
SEE DETAIL 3, SHEET C-5019
AROUND PIPE PENETRATION,
FOR ADDITIONAL REINFORCING
NOTE:
HOOK BOLT
3/4" x 19" x 5"
(OUTSIDE FACE)
CULVERT HEADWALL
(INSIDE FACE OF CULVERT)
STRUCTURAL PLATE
EL 943.50
T/FOOTER
PLAN VIEW
FRONT ELEVATION
A C-5019
LEFT WINGWALL - FRONT ELEVATION
LEFT WINGWALL - REAR ELEVATION
8 - #6 (EQUALLY SPACED)
#7 AT 12" C/C
13 - #6 (EQUALLY SPACED)
#4 AT 18" C/C
#5 AT 18" C/C
#6 AT 12" C/C
8 - #5 (EQUALLY SPACED)
3 - #5 (EQUALLY SPACED)
BOTH ENDS
STD 90° HOOK
#6 @ 12" C/C
GRADE
FINISHED
GRADE
FINISHED
2 - #5
APPROXIMATELY 1/4 INCH
TO A FULL AMPLITUDE OF
INTENTIONALLY ROUGHENED
FREE OF LAITANCE, AND
CONCRETE SHALL BE CLEAN,
8 - #6 (EQUALLY SPACED)
#7 AT 12" C/C
13 - #6 (EQUALLY SPACED)
#4 AT 18" C/C
#5 AT 18" C/C
#6 AT 12" C/C
8 - #5 (EQUALLY SPACED)
3 - #5 (EQUALLY SPACED)
BOTH ENDS
STD 90° HOOK
#6 @ 12" C/C
GRADE
FINISHED
GRADE
FINISHED
2 - #5
APPROXIMATELY 1/4 INCH
TO A FULL AMPLITUDE OF
INTENTIONALLY ROUGHENED
FREE OF LAITANCE, AND
CONCRETE SHALL BE CLEAN,
05 19 GEOTEXTILE.
STRUCTURE BACKFILL AND THE EMBANKMENT ROCK FILL. GEOTEXTILE FABRIC SHALL MEET THE REQUIREMENTS OF 31
SECTION 3.11.1.2 STRUCTURE BACKFILL. GEOTEXTILE FABRIC SHALL BE PLACED CONTINUOUSLY BETWEEN THE
WINGWALLS. STRUCTURE BACKFILL AND COMPACTION SHALL MEET THE REQUIREMENTS OF 31 00 00 FOR EARTHWORK, AND THE PROFILE ON C-4012. THE STRUCTURE BACKFILL SHALL TERMINATE 2’ BELOW THE TOP OF THE HEADWALL AND
5. THE STRUCTURE BACKFILL SHALL BE INSTALLED AS SHOWN ON DETAIL 1, SHEET C-5015, SECTIONS A AND B ON C-3017, COVER FOR REINFORCING SHALL BE 3 INCHES, UNLESS OTHERWISE NOTED.
4. ALL REINFORCING STEEL SHALL BE EPOXY COATED BARS, UNLESS OTHERWISE NOTED ON THE DETAIL. MINIMUM
CONTINUED A MINIMUM OF 1-FT BELOW FINISHED GROUND LINE.
3. ALL EXPOSED CONCRETE EDGES SHALL HAVE A 3/4" x 45° CHAMFER. CHAMFER ON VERTICAL EDGES SHALL BE
CONCRETE SHALL BE 5,000 PSI COMPRESSIVE STRENGTH CONCRETE.2.
CAST-IN-PLACE OR PRECAST. CONCRETE SHALL MEET THE REQUIREMENTS OF 03 30 00 CAST-IN-PLACE CONCRETE.
AND WINGWALLS SHALL BE REINFORCED CONCRETE UNLESS OTHERWISE APPROVED. THE HEADWALL MAY BE EITHER
A HEADWALL WITH WINGWALLS SHALL BE INSTALLED AS AN END TREATMENT FOR THE ARCH CULVERT. THE HEADWALL 1.
NOTES:
B C-5018
B
C-5018 SCALE: 3/8" = 1’-0"
TYPICAL WALL SECTION
WALLS
TYP ALL
C-5018 SCALE: 3/4" = 1’-0"
DETAIL - STRUCTURAL PLATE ANCHORAGE
C-4012
C-1011 SCALE: 1/8" = 1’-0"
DETAIL - CULVERT HEADWALL
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
C -5
.d g n
-J
U L -2
:1
0.083334:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
C-5018
C R
A T
T Y /B
B A
K E
R
H E
A D
W A
L L D
E T
A
IL
S
0 8’4’ 16’
SCALE: 1/8"=1’
4’0 2’ 8’
SCALE: 3/8"=1’
J
U L
Y
J F
R E
E M
A N
E
G U
Y G
M E
Y E
R
/s E
R
IC
H D
G U
Y P .E
2’0 1’ 4’
SCALE: 3/4"=1’
S H
E E
T O
Q S
P A
C E
D
8 - #5
E Q S
P A
C E
D
E Q S
P A
C E
D
3 - #5
E Q S
P A
C E
D
(TYP)
2"
CLR
(TYP)
1’-
0"
.1
L
#6 A
T 2" C /C
#7 V E
R T
IC
A L B
A R
S A
T
12" C /C (U
P F
R O
M B
O T
T O
M
18" C /C (U
P F
R O
M B
O T
T O
M
#5 S
LA
N T
E D B
A R
S A
T
C CULVERT
NOTE:
ABOUT CENTERLINE OF CULVERT
FOOTER REINFORCING SYMMETRICAL
#5 A
T 8" C /C
#7 A
T 2" C /C
LC CULVERT
NOTE:
ABOUT CENTERLINE OF CULVERT
FOOTER REINFORCING SYMMETRICAL
WALL (TYP)
HORIZONTAL REBAR FOR
SIZE TO MATCH TYPICAL
ADDED HORIZONTAL REBAR
REBAR FOR WALL (TYP)
TO MATCH TYPICAL VERTICAL
ADDED VERTICAL REBAR SIZE
SHOWN FOR CLARITY (TYP)
INTERRUPTED BARS NOT
BACK FACE: 4’-2"
EXPOSED FACE: 2’-5"
FOLLOWS:
OUTERMOST BAR IS AS
EXTENSION BEYOND THE
THE DIMENSION OF THE
BACK FACE: 4’-2"
EXPOSED FACE: 2’-5"
AS FOLLOWS:
DIMENSIONS SHOULD BE
OUTERMOST BAR. HOOK
EXTENDING BEYOND THE
REQUIREMENTS FOR
MEET THE DIMENSION
HOOK BARS THAT CANNOT
OVERFLOW PIPE
PVC SEWER
EXISTING 21" DIA
B C-5019
1. WORK THIS DRAWING WITH SHEET C-5018.
NOTE:
A
C-5018 SCALE: 3/8" = 1’-0"
SECTION - FOOTER REINFORCING - TOP LAYER A
C-5018 SCALE: 3/8" = 1’-0"
SECTION - FOOTER REINFORCING - BOTTOM LAYER
C-5018 SCALE: 3/8" = 1’-0"
DETAIL - WINGWALL REINFORCING AT PIPE PENETRATION
B
C-5019 SCALE: 3/8" = 1’-0"
SECTION - WINGWALL REINFORCING AT PIPE PENETRATION
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
C -5
.d g n
-J
U L -2
:1
0.083334:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
C R
A T
T Y /B
B A
K E
R
H E
A D
W A
L L D
E T
A
IL
S
4’0 2’ 8’
SCALE: 3/8"=1’
J
U L
Y
J F
R E
E M
A N
E
G U
Y G
M E
Y E
R
/s E
R
IC
H D
G U
Y P .E
S H
E E
T O
F
C-5019
(T
P
(M
IN
4’-6"
12’ (MIN)
(T Y
P
(M
IN
9’-0"
12’ (MIN)
4’-9 1/4 "
3’-9 1/4 "
1 1/2 "
4’-0 1/4 "
FRAME
GALVANIZED ANGLE
1 3/4" X 1 3/4" X 1/4"
3’-0"
/2
SEE NOTE 6
(2) "U" SHAPE #3 BARSWIRE MESH RING
6" X 6" 8/8 GAUGE WELDED
ON EACH WALL
KNOCKOUTS
24" SQUARE
3’-9 1/4 "6" 6"
4’-9 1/4 "
V A
R
IE
S
V A
R
IE
S
EXISTING GROUND
N O
T E
S E
E
GEOTEXTILE
(SEE NOTE)
SLOPE VARIES
R-5 STONE PROTECTION
LIMITS OF EXCAVATION
NOTE:
SURFACE
WATER
LOW FLOW
LIMITS OF EXCAVATION
1.75 (MAX)
1.75 (MAX)
(TYP.)
EMBEDMENT
GEOTEXTILE
6" MIN.
THAN 1.75H:1V. FINAL DIMENSIONS SHALL BE DETERMINED IN THE FIELD.
FEET. SLOPES VARY TO CONFORM TO EXISTING GROUND, BUT SHALL BE NO STEEPER
STABILIZATION VARY, BUT SHALL EXTEND TO THE TOP OF THE BANK OR NO LESS THAN 4
DIMENSIONS OF BANK STABILIZATION SHOWN ARE APPROXIMATE. DIMENSIONS OF BANK
N O
T E
S E
E
NOTE:
GEOTEXTILE
(SEE NOTE)
SLOPE VARIES
R-5 STONE PROTECTION
SURFACE
WATER
LOW FLOW
LIMITS OF EXCAVATION
1.75 (MAX)
1GROUND
EXISTING
LIMITS OF EXCAVATION
1.75 (MAX)
(TYP.)
EMBEDMENT
GEOTEXTILE
6" MIN.
THAN 1.75H:1V. FINAL DIMENSIONS SHALL BE DETERMINED IN THE FIELD.
FEET. SLOPES VARY TO CONFORM TO EXISTING GROUND, BUT SHALL BE NO STEEPER
STABILIZATION VARY, BUT SHALL EXTEND TO THE TOP OF THE BANK OR NO LESS THAN 4
DIMENSIONS OF BANK STABILIZATION SHOWN ARE APPROXIMATE. DIMENSIONS OF BANK
1 1/2 "
4 1/2 "
SEE RC-45M SHEET 8 FOR STRUCTURAL STEEL BICYCLE SAFE GRATE.6.
SEE RC-45M SHEET 2 FOR REINFORCING DETAILS5.
ALL TOLERANCES SHALL BE +/- 1/4" UNLESS NOTED.4.
ALL OUTSIDE CORNERS TO HAVE A 1/2" X 1/2" CHAMFER3.
ALL REINFORCEMENT TO HAVE A MINIMUM 1 1/2" CONCRETE COVER.2.
PRECAST CONCRETE TO HAVE A COMPRESSIVE STRENGTH OF 4000 PSI WITHIN 28 DAYS.1.
WALL B AND D = 24" SQ.
WALL A AND C = 26" X 36"
SECTION 01 57 23.00 08 STORM WATER POLLUTION CONTROL.
THE INLETS AND GRATES SHALL MEET THE REQUIREMENTS OF SPECIFICATIONS2.
28 DAYS.
PRECAST CONCRETE TO HAVE A COMPRESSIVE STRENGTH OF 4000 PSI WITHIN1.
X-1001 NTS
TYPICAL SECTION - TYPE M INLET
NOTE:
TYPE M TOP
KNOCK OUT SIZES
A
B
C
D
TOP VIEW
SECTION VIEW
C-1011 NTS
TYPICAL SECTION - REQUIRED MINIMUM BANK ARMORING
C-1011 NTS
TYPICAL SECTION - EXTENDED BANK ARMORING
NOTE:
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
C -5
.d g n
-J
U L -2
:1
0.083334:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
C-5020
L P
H U
R R
U N B
A N
K S
T A
B
IL
IZ
A T
IO
N
D E
T A
IL
S
0 10’ 20’
SCALE: 1"=10’
A
M A
R K
U M /C
M A
R T
IN
B
B A
K E
R /B
C R
A T
T Y
J
U L
Y
E
G U
Y
/s E
R
IC
H D
G U
Y P
(M
IN
/2 (M
A X
/2 (M
IN
16" DIA (MIN)
10’-0" MAXIMUM
LINE POSTS TO BE EQUALLY SPACED
10’-0" MAXIMUM
10" DIA (MIN)
10’-0" (MAX) 10’-0" (MAX)
(T
Y P
F A
B R
IC
W
ID
H
C-5021
M A
R T
IN
D E
T A
IL
S
B
C R
A T
T Y
J
R U
S N
A K
C H
A
IN
L
IN
K S
E C
U R
IT
Y F
E N
C E T
Y P
E F
E -5
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S fiof Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDBAC
A O a b
C -5
.d g n
-J
U L -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
A L L E
G H
E N
Y R
IV
E R B
A S
IN
C O
N E
M A
U G
H R
IV
E R L
A K
E
B L
A
IR
S V
IL
L E P
A
P E
R M
A N
E N
T E
M B
A N
K M
E N
T A
N D C
U L
V E
R T R
E P
A
IR
P
R O J E
C T
CERTIFIED FINAL DOCUMENTS
W
W N -1
-B -8
FABRIC WIDTH 72" OR LESS
USE AND SECTION
FABRIC WIDTH 108" AND OVERFABRIC WIDTH 84" TO 96"
MINIMUM OUTSIDE DIMENSIONS (NORMAL)
STEEL POST SCHEDULE
LINE POST
BRACE RAIL
CONCRETE BASE
OR PULL POST
CORNER, END
LINE POST
TIE WIRES OR CLIPS (TYP)
(3/8" MIN DIA)
TRUSS ROD
TENSION WIRE
HOG RINGS (TYP)
TIE WIRES OR
GRADE HOG RINGS (TYP)
OF FABRIC
BOTTOM
(9 GAGE, 2" MESH)
CHAIN-LINK FABRIC
OF FABRIC)
TOP AND BOTTOM
AND WITHIN 4" FROM
WIRE (15" O.C. MAX
9 GAGE STEEL TIE
ROUND POST
TENSION WIRE
TENSION BAND DETAIL
FABRIC
WIRES (2’-0" O.C. MAX)
9 GAGE STEEL TIE
NTS
TOP OR BRACE RAIL ATTACHMENT
BRACE RAIL
TRUSS ROD
PULL POST
BRACE RAIL
TRUSS ROD
POST
LINE
WIRE
TENSION
POST
LINE
WIRE
TENSION
NTS
BRACE PANEL DETAIL
STRAIGHT RUNS EXCEED 500 FEET
PROVIDE BRACE PANEL WHENEVER
NOTE:
CONCRETE BASE
(3/8" MIN DIA)
TRUSS ROD
TRUSS ROD AND BAND
BAND
TENSION
(3/8" MIN DIA)
TRUSS ROD
ROUND POST
BRACE RAIL CLAMP DETAIL
BOTTOM OF FABRIC)
4" FROM TOP AND
O.C. MAX AND WITHIN
TENSION BAND (15"
FABRIC LINK
ENGAGE EACH
TENSION BAR TO
FABRIC
TENSION BAR
CARRIAGE BOLT
END OR GATE POST DETAIL
NTS
FASTENING DETAILS
TOP RAIL
RAIL
BRACE
NTS
LINE POST ATTACHMENT
NTS
CHAIN LINK SECURITY FENCE TYPE FE-5-TBR-96 DETAIL
FABRIC WIDTH96:
FENCE WITH TOP RAIL AND TENSION WIRE AT BOTTOMTBR:
CHAIN-LINK FENCE WITHOUT BARBED-WIRE APRONFE-5:
FENCE LEGEND:
TUBULAR - ROUND
CORNER, END & PULL POSTS
TUBULAR - ROUND
LINE POSTS
TUBULAR - ROUND
TOP, BOTTOM, & BRACE RAILS
2.375" O.D. 2.875" O.D. 4.00" O.D.
1.90" O.D. 2.375" O.D. 2.875" O.D.
1.66" O.D.
CONTRACTOR SHALL RE-INSTALL GATE SECTION TO WORKING CONDITIONS.
5. BOROUGH OF BLAIRSVILLE TO PROVIDE EXISTING ENTRANCE GATE SECTION.
4. CONCRETE SHALL BE 4,000 PSI COMPRESSIVE STRENGTH CONCRETE.
IS COMPLETELY FILLED WITH CONCRETE UP TO THE TOP OF THE FOUNDATION.
3. C-SECTION POSTS SHALL BE INSTALLED SO THAT THE VOID INSIDE THE POST
PLACED ON THE SIDE OPPOSITE THE SECURE AREA.
SECURE SIDE OF THE FENCE ALIGNMENT. CHAIN-LINK FABRIC SHALL BE
2. WIRE TIES, RAILS, POSTS, AND BRACES SHALL BE CONSTRUCTED ON THE
THAT COMPLY WITH THE SPECIFICATIONS.
TO LIMIT OTHER TYPES OF FENCE SECTIONS AND METHODS OF INSTALLATION
1. DETAILS SHOWN ARE TO CLARIFY REQUIREMENTS AND ARE NOT INTENDED
C U
LVER
T (S
U
LP
H U R R
U N
SLOPE PIPE
18" TEMPORARY
SEE DETAIL 3, SHEET C-5020
TEMPORARY INLET 4’ DEEP
S
S
S
S
S
10+0
CFS-12
S
S
S
S
CO
S
S
SCALE: 1" - 20’
PLAN - EROSION AND SEDIMENT CONTROL MEASURES
CFS-12
CFS-18
CFS-24
U
L P
H U
R R
U N
F L O
W
(APPROX)
STREAM BANK
TOP OF EXISTING
ENTRANCE
CONSTRUCTION
EXISTING ROCK
CULVERT
BRICK ARCH
LAYDOWN AREA
CONTRACTOR
EXISTING
ACCESS ROAD
TEMPORARY
EXISTING
ZONE A - 100 YEAR FLOOD PLAIN BOUNDARY
ZONE A - 100 YEAR
FLOODPLAIN BOUNDARY
X-5002
TEMPORARY STREAM CROSSING
12" DIAMETER COMPOST FILTER SOCK
18" DIAMETER COMPOST FILTER SOCK
24" DIAMETER COMPOST FILTER SOCK
LIMITS OF DISTURBANCE
APPROXIMATE STREAM LIMIT, WIDTH
X-5004
TEMPORARY SANDBAG DAM
X-5004
PIPE FLUME
X-5004
ROCK FILTER
FENCE
X-5003
COMPOST FILTER SOCK (TYP)
SE…