LBP Bldg. 45 Red Cross.pdf
PDF 124 KB Posted
- Attached to
- B45 Roof Replacement Federal contract opportunity
- Solicitation number
- W911SG25BA023
About this file
This document is an LBP (Lead-Based Paint) Testing Data Sheet for a Red Cross building (Building Number 45) undergoing roof replacement. The testing was conducted on 4/9/2025 using a Viken/Pb200e XRF instrument, with inspectors documenting six sample locations across the building's east, north, and west ends. The data sheet reveals positive lead-based paint findings on wood fascia and soffit components in green and white colors, with all tested areas classified as "POSITIVE" and in "INTACT" condition. The testing conforms to the Texas Department of State Health Services lead measurement standard of 1.0 mg/cm², with XRF readings ranging from 16.1 to 19.1 mg/cm² across the sampled locations.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Abstract of Offerors OF_1419 Page 1.pdf | ||
| Abstract of Offerors OF_1419 Page 2.pdf | ||
| Abstract of Offerors OF_1419 Page 3.pdf | ||
| RFI Answers.pdf | ||
| Bldg 45 - Roofing (Updated).pdf | ||
| Solicitation Amendment W911SG25BA0230001 SF 30.pdf | ||
| B45 Sign in sheet.pdf | ||
| Asbestos Survey Bldg. 45.pdf | ||
| Bldg 45 Roofing.pdf | ||
| Wage Determination.txt | TXT text file | |
| Solicitation - W911SG25BA023.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LBP TESTING DATA SHEET
Facility Information: Roof replacement
Facility Name: Red Cross Building Number: 45
XRF Model and M/N: Viken/Pb200e Date of Assessment: 4/9/2025
XRF Instrument S/N: 2759 Inspector Name(s): Frank Lujan/Paul Rodriguez
Data Sheet
SA
M
P
LE
I D
SU
B
ST
R
A
TE
C O
M P
N
EN
T
C O
LO
R
O F
C O
M P
O N
EN
T
TE
ST
L O
C A
TI
N
D
ES
C R
IP
TI
X R
F R
EA
D
IN
G
(m g/ cm ²)
LA
SS
IF
IC
A
TI
N D
IT
IO
N/A N/A N/A Green Calibration (< 0.00) .1 ACCEPTABLE N/A
N/A N/A N/A Green Calibration (0.8 to 1.2) 1.0 ACCEPTABLE N/A
LBP-01 Wood Fascia Green East end 16.5 POSITIVE INTACT
LBP-02 Wood Soffit White East end 16.1 POSITIVE INTACT
LBP-03 Wood Fascia Green North end 17.7 POSITIVE INTACT
LBP-04 Wood Soffit White North end 18.0 POSITIVE INTACT
LBP-05 Wood Fascia Green West end 19.1 POSITIVE INTACT
LBP-06 Wood Soffit White West end 17.3 POSITIVE INTACT