About this file

This document is an LBP (Lead-Based Paint) Testing Data Sheet for a Red Cross building (Building Number 45) undergoing roof replacement. The testing was conducted on 4/9/2025 using a Viken/Pb200e XRF instrument, with inspectors documenting six sample locations across the building's east, north, and west ends. The data sheet reveals positive lead-based paint findings on wood fascia and soffit components in green and white colors, with all tested areas classified as "POSITIVE" and in "INTACT" condition. The testing conforms to the Texas Department of State Health Services lead measurement standard of 1.0 mg/cm², with XRF readings ranging from 16.1 to 19.1 mg/cm² across the sampled locations.

View the file

Other files for this federal contract opportunity

Other files attached to B45 Roof Replacement, newest first.
File Type Posted
Abstract of Offerors OF_1419 Page 1.pdf PDF
Abstract of Offerors OF_1419 Page 2.pdf PDF
Abstract of Offerors OF_1419 Page 3.pdf PDF
RFI Answers.pdf PDF
Bldg 45 - Roofing (Updated).pdf PDF
Solicitation Amendment W911SG25BA0230001 SF 30.pdf PDF
B45 Sign in sheet.pdf PDF
Asbestos Survey Bldg. 45.pdf PDF
Bldg 45 Roofing.pdf PDF
Wage Determination.txt TXT text file
Solicitation - W911SG25BA023.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LBP TESTING DATA SHEET

Facility Information: Roof replacement

Facility Name: Red Cross Building Number: 45

XRF Model and M/N: Viken/Pb200e Date of Assessment: 4/9/2025

XRF Instrument S/N: 2759 Inspector Name(s): Frank Lujan/Paul Rodriguez

Data Sheet

SA

M

P

LE

I D

SU

B

ST

R

A

TE

C O

M P

N

EN

T

C O

LO

R

O F

C O

M P

O N

EN

T

TE

ST

L O

C A

TI

N

D

ES

C R

IP

TI

X R

F R

EA

D

IN

G

(m g/ cm ²)

LA

SS

IF

IC

A

TI

N D

IT

IO

N/A N/A N/A Green Calibration (< 0.00) .1 ACCEPTABLE N/A

N/A N/A N/A Green Calibration (0.8 to 1.2) 1.0 ACCEPTABLE N/A

LBP-01 Wood Fascia Green East end 16.5 POSITIVE INTACT

LBP-02 Wood Soffit White East end 16.1 POSITIVE INTACT

LBP-03 Wood Fascia Green North end 17.7 POSITIVE INTACT

LBP-04 Wood Soffit White North end 18.0 POSITIVE INTACT

LBP-05 Wood Fascia Green West end 19.1 POSITIVE INTACT

LBP-06 Wood Soffit White West end 17.3 POSITIVE INTACT

NOTES:

DPW-ED conforms to Texas Department of State Health Services lead measurement standard, 1.0mg/cm2 by X-ray fluorescence.