Amendment-7.pdf
PDF 56 KB Posted
- Solicitation number
- W911SF-12-R-0020
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment-7-Guardian-60kW.pdf.pdf | ||
| Amendment-6.pdf | ||
| Amendment-5.pdf | ||
| Attachment_T_v2.pdf | ||
| Amendment-4.pdf | ||
| Amendment_3.pdf | ||
| Sign-In_Sheet.pdf | ||
| REC.pdf | ||
| Amendment_2.pdf | ||
| Amendment_1.pdf | ||
| Attachment_U.pdf | ||
| Attachment_I.pdf | ||
| Attachment_K.pdf | ||
| Attachment_E.pdf | ||
| Attachment_Ra.pdf | ||
| Attachment_H.pdf | ||
| Attachment_D.pdf | ||
| Attachment_L.pdf | ||
| W911SF-12-R-0020.pdf | ||
| Attachment_F.pdf | ||
| Attachment_A.pdf | ||
| Attachment_O.pdf | ||
| Attachment_C.pdf | ||
| Attachment_B.pdf | ||
| Attachment_R.pdf | ||
| Attachment_M.pdf | ||
| Attachment_Rb.pdf | ||
| Attachment_P.pdf | ||
| Attachment_J.pdf | ||
| Attachment_Q.pdf | ||
| Attachment_Rd.pdf | ||
| Attachment_Rc.pdf | ||
| Attachment_T.pdf | ||
| Attachment_N.pdf | ||
| Attachment_G.pdf |
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MISSION & INSTALLATION CONTRACTING CMD
MAURICE L HUDSON, CPT, CCO
706-545-4943
MAURICE.L.HUDSON.MIL@MAIL.MIL
FT BENNING GA 31905
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
This solicitation is amended as follow s:
a. This amendment is issued to answ er questions that w ere previously omitted from the previous amendments.
b. ATTACHMENT(s) made part of the resulting contract – has been updated. http://w w w .benning.army.mil/tenant/MICC/CCT.html
c. FAR clause 52.211-12 LIQUIDATED DAMAGES--CONSTRUCTION (SEP 2000) has been updated w ith liquidated damages at #13.
d. Offerors are reminded of the requirement to acknow ledge receipt of this amendment w ith proposal submission.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 6
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 21-Dec-2012
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W911SF-12-R-0020
X 9B. DATED (SEE ITEM 11)
30-Sep-2012
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
21-Dec-2012
CODE
MISSION & INSTALLATION CONTRACTING CMD
MICC - FORT BENNING
6600 MELOY DRIVE
BUILDING 6, SUITE 250
FT BENNING GA 31905
W911SF 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE W911SF
FACILITY CODECODE
EMAIL:TEL:
W911SF-12-R-0020
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
The following items are applicable to this modification:
MODIFICATION
1. Are there specifications for concrete?
ANSWER : Yes. All specifications for this project were updated to MICC- Fort Benning website. http://www.benning.army.mil/tenant/MICC/CCT.html
2. Drawings – Drawing No. 43105-C8 Utility Plan shows the domestic water service, but does not show the fire protection water service. Where is the anticipated tap to the existing 8” water main for the fire protection water service and what is the desired location fire service entry into the building?
ANSWER: The fire service is located at the back corner of the north wall. The riser shall be located midway of the back wall of the service bay. The fire hose building connections to be located on the front of the building between the front door and service bay door.
Contractor shall show us where he intends to exit the building with the fire service lateral.
We will pass this info along to Columbus Water Works. The contractor shall terminate the fire protection service 5 feet outside the building and install a temporary cap. Stub the end of the pipe with a 2-inch PVC pipe and label the pipe for Columbus Water Works to identify and make the final connections. We would like to see the fire service tap exit either side or front of the building.
3. Drawings – Drawing No. 43105-FP1 states we are to design a fire suppression system for the fire station. What is the available water pressure and water flow rate in the existing 8” water main?
ANSWER: We do not have that data available for the bid proposal package. Please make an educated guess. Whoever is awarded the contract to execute will have the responsibility to contact Columbus Water Works to obtain the data to design the fire suppression system.
4. Specifications – Division 21 00 00 Fire Suppression has a specification section 21 30 00
Fire Pump, but the drawings do not show a location for a fire pump. We are also not able to find any power provisions for the fire pump on the electrical drawings. Is a fire pump to be provided?
ANSWER: The Government provided Section 21 13 00.00 40 for the contractors to use to prepare the fire suppression package for the bid proposals. There is no “FIRE PUMP” specified in the section.
http://www.benning.army.mil/tenant/MICC/CCT.html
5. Drawings – Drawing Nos. 43105-M1 and 43105-M2 show a scale of ½”=1’-0”, but the scale of the drawings does not appear to be ½”=1’-0” if the building is 126’ x 60’. What is the correct scale for Drawing Nos. 43105-M1 and 43105-M2?
ANSWER: The scale should be 1/4-inches equals 1’-0”.
6. Drawings – Drawing Nos. 43105-P1, 43105-P2, and 43105-P3 show a scale of ⅜”=1’-0”, but the scale of the drawings does not appear to be ⅜”=1’-0” if the building is 126’ x 60’.
What is the correct scale for Drawing Nos. 43105- P1, 43105-P2, and 43105-P3?
ANSWER: The scale should be 3/16-inches equals 1’-0”.
7. Drawings – Sheet 43105-A.10 – Door Schedule has Door No. 120 that is not found on the
Floor Plan, Sheet 43105-A.1. Is Door No. 120 required?
ANSWER: Door 120 on the Door Schedule corresponds to Door 121B on the floor plan.
This door is the pantry door for the Kitchen. Please revise floor plan Door 121B in the KITCHEN to read Door 120.
8. Drawings – Sheets 43105-A.1 & 43105-A.11– Door Schedule, Sheet 43105-A.10 has a
Door No. 120A that is not found on the Floor Plan, Sheet 43105-A.1, nor Enlarged Plan, 4/A.11, but appears to match the requirements for Door No. 121B on the Floor Plan, Sheet 43105-A.1 and Enlarged Plan, 4/A.11. Is Door Mark 121B on Sheets 43105-A.1 & 43105-A.11 to be changed to 120A to match the door schedule on Sheet 43105-A.10?
ANSWER: Door 120 on the Door Schedule corresponds to Door 121B on the floor plan.
This door is the pantry door for the Kitchen. Please revise floor plan Door 121B in the KITCHEN to read Door 120.
9. Drawings – Sheet 43105-E0 – Electrical keyed note 9 states, “ATMOS ENERGY WILL
SUPPLY LIQUID PROPANE FOR GENERATOR.” It is our understanding that ATMOS Energy provides natural gas service and not liquid propane. Will ATMOS Energy provide natural gas service to this generator?
If not, does Fort Benning have an agreement with a local LP company for fuel and service and, if so, what is the name of the firm?
ANSWER: New battle plan. As per our utility manager, the government is changing the design by deleting the requirement to provide a Government furnished propane tank for the contractor to install, and deleting the requirement for the contractor to install the concrete pad for the tank and installing buried gas piping from the tank to the generator.
The Government will by a separate contract, install the gas piping to within 5 feet of the generator and terminate the service with a gas meter assembly and cutoff valve. The contractor will be required to install the gas piping from the generator up to and connect to the cutoff valve.
10. Specifications – Drawing 43105-E0 shows a 60 KW LP Emergency Generator, but there is no specification for the emergency generator. What are the testing and specification requirements for the Emergency Generator shown on Drawing 43105-E0?
ANSWER: See Attached Specification. Guardian 60 KW or Equal.pdf.
11. On page 90 of 94, Volume IV - Price Proposal - Evaluation Factor 4, the second paragraph reads as follows: (2) On separate Microsoft compatible documents of the offeror’s choosing, Offerors are to provide a total lump sum price, on a firm fixed prices basis, for the seed project supported by a narrative and detailed computations that explain and depict how their price for the seed project was developed. Provide a price breakdown of all direct and indirect costs to include overhead and profit. The seed projects is “live,” which means it is anticipated to be awarded at the time of IDIQ contract award, and therefore Offerors should submit their very best price. It is virtually impossible to provide this extensive breakdown for direct and indirect costs with the proposal at the time of the bid. Most prices are not received until a few hours before bid time.
ANSWER: The vendor awarded the SEED contract will be required to submit.
12. ADDITIONAL INPUT:
We have been receiving telephone calls from various mechanical subcontractors about the testing, adjusting, balancing, and commissioning of the HVAC systems. The Government provided SECTION 23 05 93.00 10, Testing, Adjusting, and Balancing of HVAC Systems, which specifies the mechanical subcontractor to provide a certified testing and balancing company to execute the tasks and reporting specified in the document.
The Government is changing the requirement in SECTION 23 05 93.00 10 that requires the mechanical subcontractor to hire a certified testing and balancing company to execute the specified tasks in the section. The Government will allow the mechanical subcontractor to use his equipment and personnel to execute the specified tasks and reporting in SECTION 23 05 93.00 10 in lieu hiring a certified testing and balancing company.
13. 52.211-12 LIQUIDATED DAMAGES--CONSTRUCTION (SEP 2000)
(a) If the Contractor fails to complete the work within the time specified in the contract, the Contractor shall pay liquidated damages to the Government in the amount of $130.58 for each calendar day of delay until the work is completed or accepted.
(b) If the Government terminates the Contractor's right to proceed, liquidated damages will continue to accrue until the work is completed. These liquidated damages are in addition to excess costs of repurchase under the Termination clause.
14. ATTACHMENT(s) made part of the resulting contract – has been updated.
00 COVER-43105
00LIST OF SPECS
01 33 00 01 42 00 01 78 00 01 78 23 03 11 14.00 10 03 15 14.00 10 03 20 01.00 10 03 20 02 03 30 00 04 20 00 05 40 00 06 10 00 06 41 16.00 10 06 61 16 07 21 16 07 61 15.00 20 07 84 00 07 92 00 08 11 13 08 14 00 08 36 13 08 51 13 08 71 00 08 81 00 08 91 00 09 29 00 09 30 00 09 51 00 09 65 00 09 65 66 09 67 23.13 09 68 00 09 90 00.00 40 09 90 00 10 14 02 10 44 16 11 05 40 11 31 13 11 47 00 21 13 00.00 40 22 00 00
23 00 00 23 05 93.00 10 23 07 00 23 35 00.00 10 23 81 00.00 20 26 00 00.00 20 26 20 00 26 24 16.00 40 26 36 23.00 20 26 42 14.00 10 26 51 00 31 00 00 31 32 11 32 16 13 33 11 23 44 42 53 13855N Army Standard – Fire Station (Apr10) Fire Alarm System SOP Ufc_4_021_01_Chng1
THE DATE AND TIME FOR RECEIPT OF PROPOSALS REMAINS
UNCHANGED.