Upgrades to Facility and Parking Lot and Construct Dry Storage Building at Stillwater, OK
Solicitation number
W911SA-18-B-2009
Issued by

About this file

Attachment 3 - Drawings

View the file

Other files

File Type Posted
W911SA-18-B-2009_Bid_Abstract.pdf PDF
W911SA-18-B-2009_Solicitation_Amendment_0002.docx DOCX document
W911SA-18-B-2009_Attachment_12_-_Phase_I_and_Phase_II_Interior.pdf PDF
W911SA-18-B-2009_Attachment_4_-_Wage_Determination_5_4_18.docx DOCX document
W911SA-18-B-2009_Attachment_2_-_SOW_5_4_18.docx DOCX document
W911SA-18-B-2009_Solicitation_Amendment_0001.docx DOCX document
W911SA-18-B-2009_Attachment_11_-_Phase_I_and_Phase_II_Exterior.pdf PDF
W911SA-18-B-2009_Attachment_8_-_Combined_Construction_Drawings_Part_Two_of_Three.pdf PDF
W911SA-18-B-2009_Attachment_7_-_Combined_Modernization_Drawings_Part_One_of_Two.pdf PDF
W911SA-18-B-2009_Attachment_1_-_AT_OPSEC.pdf PDF
W911SA-18-B-2009_Attachment_5_-__SF_24.pdf PDF
W911SA-18-B-2009_Attachment_6_-_Parking_Lot_Drawings.pdf PDF
W911SA-18-B-2009_Attachment_9_-_Asbestos_Analysis.pdf PDF
W911SA-18-B-2009_Attachment_4_-_Wage_Determination.docx DOCX document
W911SA-18-B-2009_Attachment_8_-_Combined_Construction_Drawings_Part_One_of_Three.pdf PDF
W911SA-18-B-2009_Attachment_2_-_Scope_of_Work.pdf PDF
W911SA-18-B-2009_Attachment_7_-_Combined_Modernization_Drawings_Part_Two_of_Two.pdf PDF
W911SA-18-B-2009_Solicitation.docx DOCX document
W911SA-18-B-2009_Attachment_10_-_Asbestos_Inspection_Summary.pdf PDF
W911SA-18-B-2009_Attachment_8_-_Combined_Construction_Drawings_Part_Three_of_Three.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1290 SF

WASH RACK

2581 SF

P1002

OMS

POV PARKING

POV PARKING

46754 SF

P1001

USARC

N

TO SCALE

NOT DRAWN

Stillwater, OK 74074-1599

2715 Washington street

CLEO O PAYNE USARC

4.0

SOW

SITE PLAN

2025 SF

BUILDING

DRY STORAGE

NEW

LOADING RAMP

NEW

LADDER

NEW

9'-0"

POV PARKING

MEP PARKING

MEP PARKING

POV PARKING

120'-0"

DN

62'-0"

(95'-6")

95'-4"

(34'-5")

34'-6"

(27'-7")

27'-6"

(7

62'-0" (10'-0")

10'-2"

(2

(7

(52'-0")

52'-6"

(7

(10'-0")

9'-10"

97'-4"

(4

DRILL HALL

3124.9 SF

STORAGE

N/A

KITCHEN

293.3 SF

OFFICE

100 SF

STORAGE

151.7 SF

ADMIN

XXXXX

OFFICE

904.8 SF

VEST

47 SF

RETENTION

243.9 SF

OFFICE

128.9 SF

ADMIN

753.9 SF

OFFICE

88.3 SF

OFFICE

99.2 SF

OFFICE

190.1 SF

OFFICE

173.4 SF

OFFICE

91.8 SF

FAX

75.5 SF

LATR

186.8 SF

OFFICE

88.7 SF

MAIL

88.7 SF

CLASSROOM

1035 SF

OFFICE

88.2 SF

OFFICE

100 SF

NBC

161.3 SF

STOR

146.7 SF

MECH

507.9 SF

SCULLERY

157.5 SF

MECH

241.3 SFCORR

246.4 SF

ARMS

258 SF

OFFICE

104 SF

ADMIN

219.7 SF

ADMIN

219.7 SF

OFFICE

104 SF

OFFICE

104 SF

ADMIN

219.7 SF

OFFICE

104 SF

ADMIN

219.7 SF

OFFICE

104 SF

ADMIN

219.7 SF

LIBRARY

491.4 SF

CLASS

495.1 SF

COMMON

1188 SF

VEST

43.3 SF

SHOWER

116A

55.8 SF

JANITOR

42.4 SF

LATR

125.3 SF

CORR

973.7 SF

N

TO SCALE

NOT DRAWN

Stillwater, OK 74074-1599

2715 Washington Street

CLEO O. PAYNE USARC

FLOOR PLAN

4.1

SOW

LADDER

ROOF ACCESS

NEW CAGED

OFFICE

173.4 SF

OFFICE

91.8 SF

FAX

75.5 SF

LATR

186.8 SF

OFFICE

88.7 SF

MAIL

88.7 SF

N

DEMOLITION

TO SCALE

NOT DRAWN

REFERENCE

SHOWERS, I.T. ROOM

BREAK ROOM, LATRINE

4.2 - 4.3 - 4.4

SOW

AC COND

A C E

V A

P

OFFICE

IT ROOM

3'-0"

16'-0"

4'-10"

BRK RM

150 S.F.

190 S.F.

44 S.F.

310.7 S.F.

LATRINE

N

RECONSTRUCTION

TO SCALE

NOT DRAWN

REFERENCE

SHOWERS, I.T. ROOM

BREAK ROOM, LATRINE

4.2 - 4.3 - 4.4

SOW

/2

SHOWER

ADA

B E

N C

H F

O L

D

IN

G

EXHAUST FAN

FLOOR DRAIN

3'-0"

4'-1 1/2 "

HOOKS (7)

SHOWER

WALLS

FRAMED "BLOCKING"

ADA SHOWER

15'-0"

19'-0"

4'-0"

3'-0"6'-0 1/2 "3'-0"

TO SCALE

NOT DRAWN

CABINET REFERENCE

4.2 - 4.3 - 4.4

TO SCALE

NOT DRAWN

4.2-4.3-4.4

SOW

REFERENCE

ELEVATION

EXHAUST FAN

Exhaust Fan Intake Grill

Exhaust Fan

Backdraft Damper

RETENTION

243.9 SF

OFFICE

128.9 SF

TO SCALE

NOT DRAWN

FAX ROOM

RM139

4.5

SOW

N

DEMOLITION

RETENTION

243.9 SF

OFFICE

128.9 SF

TO SCALE

NOT DRAWN

FAX ROOM

RM139

4.5

SOW

RECONSTRUCTION

CLASSROOM

z

1035 SF

4.6

SOW

TO SCALE

NOT DRAWN

CLASSROOM

RM146

REMOVE TWO EXISTING CHALKBOARDS

285 SF

146 A

CLASSROOM

769 SF

146 B

3 LAN DROPS ON EACH SIDE

3 ELECTRICAL OUTLETS AND

ADD THIS WALL COMPLETE WITH

z

RECONSTRUCTION

4.6

SOW

INSTALL 2 - 4'X8' DRY ERASE BOARDS

COMPUTER LAB

TO SCALE

NOT DRAWN

RM146B CLASSROOM

RM146A COMPUTER LAB

15'-0"

TO MAKE ROOM FOR NEW DRY ERASE BOARD

TO THE NEW LOCATION (BLUE) IN ORDER

RELOCATE EXISTING ELECTRICAL (RED)

NEW 4'X8' DRY ERASE BOARDNEW 4'X8' DRY ERASE BOARD

4.6

SOW

SINGLE GANG RECEPTICLES WITH SS COVER

DRY ERASE BOARDS

LOOKING NORTH

CLASSROOM WALL

RM146B

ADMIN

753.9 SF

OFFICE

88.3 SF

OFFICE

99.2 SF

N

TO SCALE

NOT DRAWN

ADMINISTRATION

RM132

4.7

SOW

DEMO EXISTING DOOR (1)

ADMIN

CONFERENCE

132B

132A

357.0 SF

416.5 SF

Z

RECONSTRUCTION

OFFICE

OFFICE

88.3 SF

99.2 SF

4.7

SOW

TO SCALE

NOT DRAWN

RM132B CONF

RM132A ADMIN

18' 0"

INSTALL NEW DOOR ASSEMBLY

CONSTRUCT NEW WALL

ENCLOSE OLD DOOR OPENING

NOT DRAWN

LATRINE

WOMENS

RM116

4.9

SOW

LATRINE

125.3 SF

TOILETS, AND PARTITIONS

DEMO EXISTING SINKS, COUNTER,

FLOORING

DEMO THE EXISTING CERAMIC

VALVES AND HEADS

DEMO THE EXISTING SHOWER

AND NOT BE REPLACED

THIS SINK WILL DEMO

125.3 SF

AND MIRROR

VANITY / SINK, FAUCET

NEW ADA 36"

LATRINE

CONSTRUCTION

FIXTURES

TOILETS AND ADA

NEW LOW WATER USAGE

UP WALLS

FLOORING & 4'

NEW EPOXY RESIN

TO SCALE

NOT DRAWN

LATRINE

WOMENS

RM 116

4.9

SOW

HEADS

SHOWER VALVES & SHOWER

NEW LOW WATER USAGE

N

STALL PARTITIONS

NEW COMPOSITE ADA

DRILL HALL

3124.9 SF

STORAGE

N/A

N

4.13

SOW

TO SCALE

NOT DRAWN

DRILL HALL

RM 121

DEMO

24'-11"

DRILL HALL

3124.9 SF

STORAGE

N/A

GYM ROOM

456 SF

24'-11"

N

TO SCALE

NOT DRAWN

GYM ROOM

DRILL HALL

RM 121

4.13

SOW

CONSTRUCTION 1

20' UNIT

HVLS TYPE OVERHEAD FAN

INDUSTRIALL

CTRL

GYM ROOM

456 SF

M

IN

I S

P L

IT

M

IN

I S

P L

IT

ON TOP EDGE OF GYM ROOM

CONTINUE EXISTING RAILING

ACCESS LADDER

24'-11"

CONSTRUCTION 2

N

TO SCALE

NOT DRAWN

GYM ROOM

RM 123

4.13

SOW

6'-0"

2'-0"

4.13

TO SCALE

NOT DRAWN

SOUTH

EXTERIOR ELEVATION

DRILL / ASSEMBLY HALL

RM 121

WITH NEW FIXED WINDOWS

REPLACE EXISTING WINDOWS

4.13

TO SCALE

NOT DRAWN

NORTH

EXTERIOR ELEVATION

DRILL / ASSEMBLY HALL

RM 121

WITH NEW FIXED WINDOWS

REPLACE EXISITNG WINDOWS

4.15

SOW

EXTERIOR

SOUTH WALL

DRY STORAGE FACILITY

4' 0"

" 1

45' 0" 1' 10"

15' 0"

4.15

SOW

EXTERIOR

NORTH WALL

DRY STORAGE FACILITY

4' 0"

"1

45' 0"1' 10"

15' 0"

EXTERIOR VIEW

EAST WALL

DRY STORAGE FACILITY

4.15

SOW

10'-0"

45'-0"

6' 0"

NOT DRAWN

EXTERIOR

WEST WALL

DRY STORAGE FACILITY

4.15

45' 0"

TOP VIEW

REFERENCE

DRY STORAGE FACILITY

TO SCALE

NOT DRAWN

4.15

SOW

3' 0"

7' 4"

15' 0"

12' 0"

6' 0"

8' 0"

45' 0"

10' 0"

7' 4" 3' 0"

TYPICAL OF SOUTH WALL

NORTH WALL VIEW

INTERIOR CAGING REFERENCE

All caging shall be uniform in width.

Caging shall be fully enclosed on top with mesh panels.

Caging shall be continuous on the North and South walls.

TO SCALE

NOT DRAWN

4.15

SOW

44' 4"

6"

3'0"

4'0"

8" 8"

FOOTING

NEW CONCRETE

BOLLARD TOP

GRIND SMOOTH AND FILL WITH CONCRETE

8" DIAMETER SCHED 40 STEEL PIPE

TRAFFIC YELLOW, OR USE RETRO-REFLECTIVE SHEETING

& THEN PAINT WITH TWO COATS OF BRIGHT

REMOVE ALL RUST & FOREIGN MATTER. PRIME

BOLLARD DETAIL

TO SCALE

NOT DRAWN

EXISTING GRASS / SOIL / CONCRETE / PAVEMENT

4.15

4.16

SOW

LADDER

ROOF ACCESS

NEW CAGED

157.5 SF

SCULLERY

MECHANICAL

TO SCALE

NOT DRAWN

LADDER

ROOF ACCESS

SECURED

4.16

TO SCALE

NOT DRAWN

REFERENCE

WALL LADDER

SECURED

PANEL

SECURITY

HINGED-LOCKABLE

2581 SF

P1002

OMS

SLOPESLOPESLOPESLOPE

S L

O P

E

DOWNSPOUTS

WASHRACK

N

TO SCALE

NOT DRAWN

4.18

SOW

OF THE OMS

DRAINAGE IN FRONT

FRONT OF OMS BAY DOORS

DRAINAGE TROUGH IN

MEP CREST

RUNNING FROM

NEW CURBING

CHUTE

STORM WATER

NEW 48" BAFFLED

SHOVEL

A SQUARE POINT

WIDE ENOUGH FOR

N

REMOVEABLE GRATE

TO SCALE

NOT DRAWN

4.18

SOW

CROSSECTION REFERENCE

OF THE OMS

DRAINAGE IN FRONT

2581 SF

P1002

OMS

POV PARKING

POV PARKING

46754 SF

P1001

USARC

N

2025 SF

BUILDING

DRY STORAGE

NEW

LOADING RAMP

NEW

LADDER

NEW

9'-0"

POV PARKING

MEP PARKING

MEP PARKING

POV PARKING

S L

O P

E S

L O

P E

S L

O P

E S

L O

P E

SLOPE

LOT CREST

APPROXIMATE MEP

SLOPESLOPESLOPESLOPESLOPE SLOPE SLOPE

4.19

SOW

TO SCALE

NOT DRAWN

MEP BOUNDRIES

NORTH AND EAST

NEW CURBING ON

NEW CURBING

NEW 48" BAFFLED STORM WATER CHUTES

" 120'-0"

2581 SF

P1002

OMS

SLOPESLOPESLOPESLOPE

S L

O P

E

N

MEP CREST

RUNNING FROM

NEW CURBING

SLOPE SLOPE

SLOPE

S L

O P

E S

L O

P E

S L

O P

E

NEW CURBING

TO SCALE

NOT DRAWN

4.19

SOW

REFERENCE

NEW CURBING

SLOPE

LOADING RAMP

NEW

NEW 48" STORM WATER CHUTE NEW 48" STORM WATER CHUTE

120'-0"

PAVEMENT DETAIL FOR PARKING

NO SCALE

TACK COAT

GEO-TECH FABRIC

PAVING LEGEND:

COMPACTED SUBGRADE (95%)

(6" MINIMUM AFTER COMPACTION)

6" OF CLASS 7 AGGREGATE BASE COURSE

2" ASPHLAT INTERMEDIATE COURSE

(2" MINIMUM AFTER COMPACTION AND ROLLING)

2" ASPHALT SURFACE COURSE

PRIME COAT

PAVING NOTES:

AFTER COMPACTION) TO 95% OF STANDARD PROCTOR DENSITY.

AND COMPACT 6" OF CLASS 7 AGGREGATE BASE COURSE (6" MINIMUM

PROCTOR DENSITY. PROOF ROLL, THEN PLACE GEO-TECH FABRIC

1. SCARIFY, GRADE, AND COMPACT SUBGRADE TO 95% OF STANDARD

DEPRESSIONS THAT RETAIN WATER RUNOFF.

SHALL FOLLOW THE SLOPE OF THE EXISTING TERRAIN AND SHALL HAVE NO

AREA AFTER COMPACTION AND ROLLING. FINISHED SURFACE ELEVATION

2. THE 2" THICK ASPHALT SURFACE COURSE TO BE A MINIMUM OF 2" IN ANY

LINK FENCE.

3. ASPHALT PAVING SHALL BEGIN A MAXIMUM OF 1' FT FROM EXISTING CHAIN

4. FINISHED ASPHALT SURFACE WILL BE 2" ABOVE SURROUNDING SOIL.

FOG SEAL

TO SCALE

NOT DRAWN

4.20

SOW

MEP - POV

PAVEMENT DETAIL

STANDARD

OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.0_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.1_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.2-4.3-4.4_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.2-4.3-4.4_2
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.2-4.3-4.4_3
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.2-4.3-4.4_4
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.5_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.5_2
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.6_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.6_2
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.6_3
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.7_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.7_2
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.9_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.9_2
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.13_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.13_2
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.13_3
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.13_4
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.13_5
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.15_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.15_2
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.15_3
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.15_4
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.15_5
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.15_6
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.15_7
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.15_8
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.15_9
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.16_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.16_2
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.17_1
AR068_REPAIR MEP_DWG2
AR068_REPAIR MEP_DWG1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.18_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.18_2
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.19_1
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.19_2
OK031_REPAIR FACILITY & CONSTRUCT DRY STORAGE_SOW 4.20_1

File details come from the government source that posted it.