Attachment 12 - Building 2 Life Safety - Exit Signs.pdf
PDF 973 KB Posted
- Attached to
- Natick Building 2 Facade Federal contract opportunity
- Solicitation number
- W911QY-25-R-A020
About this file
These are 100% Construction Documents for a Life Safety - Exit Signs project at Building 2 of the U.S. Army Natick Soldier Systems Center located at General Greene Avenue in Natick, Massachusetts. The documents include detailed architectural drawings for installing new exit signs throughout the facility, with specifications including LED exit signs with universal shielding, sealed maintenance-free nickel cadmium batteries, self-diagnostic testing capabilities, and die-cast aluminum housing. The drawings provide a comprehensive floor plan showing exit sign locations across multiple rooms and areas, including electrical equipment areas, mechanical spaces, chambers, toilets, storage rooms, and control rooms. The project was issued on 17 June 2022 as part of the Directorate of Public Works (DPW) life safety improvement efforts.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G-100
CO
VE
R
SH
EE
T
CONSTRUCTION DOCUMENTS 100% SUBMISSION
U.S. Army Soilder System Center
Building 2 Life Safety - Exit Signs N/A
NSSC
General Greene Avenue Natick, MA 01760
Project Name:
Solicitation No.:
Project Address:
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AN
SI
D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
G P
D W
D W
M
AY
G -S er ie s Sh ee ts
.d w g
BU
IL
D
IN
G
L
IF
E
SA
FE
TY
EX
IT
S
IG
N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
IR
EC
TP
R A
TE
O
F
PU
B
LI
C W
O R
K S
(D
PW
G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
J
U N
E
General
G-100
G-101
Architectural
LF-100
Cover Sheet
Abbreviations, General Notes & Applicable Standards
Life Safety - Exit Sign Locations
DRAWING INDEX:
AB
ACT
ADH
ADJ
ALUM
ARCH
BD
BLDG
BM
BO
BRNG
C
CAB
C.I.P.
CJ
CLR
CMU
COL
CONC
DED
DEG
DET
DIA
DIM
DN
DR
DTL
DWG
EA
EJ
EL
ELEC
EP
EQ
EW
EXP
EXT
F
FAB
FD
FE
FEC
FFE
FTG
FMG
GALV
GC
GR
HDW
HM
HORIZ
HR
HWD
ID
IN
INT
JB
JST
JT
ANCHOR BOLT
ACOUSTICAL TILE
ADHESIVE
ADJUSTABLE
ALUMINUM
ARCHITECT/ARCHITECTURAL
BOARD
BUILDING
BEAM
BOTTOM OF
BEARING
CELSIUS
CABNIET
CAST IN PLACE
CONTROL JOINT
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
DEDICATED
DEGREE
DETAIL
DIAMETER
DIMENSION
DOWN
DOOR
DETAIL
DRAWING
EACH
EXPANSION JOINT
ELEVATION
ELECTRICAL
ELECTRICAL PANEL
EQUAL
EACH WAY
EXPANSION
EXTERIOR
FARENHEIT
FABRICATED
FLOOR DRAIN
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FLOOR ELEVATION
FOOTING
FRAMING
GALVANIZED
GENERAL CONTRACTOR
GRADE
HARDWARE
HOLLOW METAL
HOIZONTAL
HOUR
HARDWARE
INSIDE DIAMETER
INCH
INTERIOR
JAMB
JOIST
JOINT
L
LF
LH
MAS
MAT
MAX
MFRS
MIN
MISC
MO
MTL
N N/A
NIC
NO
NOM
NTS
OC
OD
OPNG
OPP
P
PART
PC
FREFAB
PSF
PSI
QTY
R
REF
REINF
REQ'D
REV
RH
RO
SCHED
SECT
SF
SHT
SIM
SQ
STD
STL
STRUCT
SUSP
T/..
TEMP
THK
TYP
UL
UNO
VERT
W/
WD
WWF
LENGTH
LINEAR FEET
LEFT HAND
MASONRY
MATERIAL
MAXIMUM
MANUFACTURER
MINIMUM
MISCELLANEOUS
MASONRY OPENING
METAL
NORTH
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OPENING
OPPSITE
PLATE
PARTITION
PRE CAST
PRE FABRICATED
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
QUANTITY
RADIUS
REFERENCE
REINFORCED(MENT)
REQUIRED
REVISION
RIGHT HAND
ROUGH OPENING
SCHEDULE
SECTION
SQUARE FOOT
SHEET
SIMILAR
SQUARE
STANDARD
STEEL
STRUCTURAL
SUSPENDED
TOP OF ...
TEMPERATURE
THICK
TYPICAL
UNDERWRITERS LABORATORY
UNLESS NOTED OTHERWISE
VERTICAL
WITH
WOOD
WELDED WIRE FABRIC
ABBREVIATIONSMATERIALS AND SYMBOLS
CONCRETE
EARTH
GRAVEL
PRE CAST CONCRETE
CMU
BRICK
STEEL, IRON
A7
A7
DETAIL
NUMBER
SECTIONAL INDICATION
DIRECTION
SHEET
NUMBER
A7
DRAWING
REVISION NUMBER
DETAIL
NUMBER
SHEET
NUMBER
COLUMN INDICATOR
EXTERIOR ELEVATION
PHOTOGRAPH KEY
CONTRACTOR SHALL DIRECT ALL QUESTIONS, REQUESTS FOR INFORMATION, OR SHOP
DRAWINGS ON ITEMS IN THE PLAN TO THE ENGINEER OF RECORD.
CONTRACTOR SHALL VISIT SITE AND BECOME FAMILIAR WITH THE PROJECT AND
CONDITIONS AFFECTING THE WORK. NO ADDITIONAL PAYMENT WILL BE MADE ON CLAIMS
THAT ARISE FROM LACK OF KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL
BE HELD TO HAVE EXAMINED THE SITE SO AS TO COMPARE FIELD CONDITIONS WITH THE
DRAWINGS AND SPECIFICATIONS. NO ALLOWANCE SHALL BE MADE TO THE CONTRACTOR
BY REASON OF THEIR FAILURE TO HAVE MADE EXAMINATION OR MANY ERROR ON THEIR
PART.
CONTRACTOR SHALL NOTIFY CONTRACTING OFFICERS REPRESENTATIVE (COR), IN
WRITING, OF DISCREPANCIES FOUND ON THE DRAWINGS PRIOR TO CONSTRUCTION.
ALL DIMENSIONS SHALL BE READ OR CALCULATED, NOT SCALED.
ALL DIMENSION SHALL BE VERIFIED AT SITE AND ANY DISCREPANCIES SHALL BE REPORTED
BY THE CONTRACTOR TO THE COR PRIOR TO ORDERING MATERIALS AND PROCEEDING THE
THE WORK. ANY OMISSIONS OR INCONSISTENCIES ON THESE DRAWINGS OR ANY
VARIATIONS OR AMBIGUITIES BETWEEN THESE DRAWINGS, AND ACTUAL SITE AND
CONSTRUCTION CONDITIONS AND/OR REQUIREMENTS SHALL BE BROUGHT TO THE
ATTENTION OF THE ENGINEER OF RECORD IN WRITING AND RESOLVED AND DOCUMENTED
IN WRITING BEFORE CONTINUING WITH THE WORK IN QUESTION.
ALL CONSTRUCTION DEBRIS SHALL BE LAWFULLY DISPOSED OF AT A SANITARY LANDFILL.
ALL WORK SHALL BE PREFORMED IN A WORKMANLIKE MANNER WITH MATERIALS INSTALLED
PER MANUFACTURER'S SPECIFICATIONS.
"TYPICAL" MEANS THE REFERENCED DETAIL SHALL APPLY FOR ALL SIMILAR CONDITIONS
UNLESS OTHERWISE NOTED.
NOTE THAT THIS IS AN EXISTING FACILITY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
VISIT THE SITE AND VERIFY EXISTING CONDITIONS FOR NEW WORK PRIOR TO MATERIAL
PURCHASE, FABRICATION AND INSTALLATION.
1.
GENERAL NOTES
PROJECT LOCATION:
(PLACE ON BUILDING)
VICINITY MAP
2.
3.
4.
5.
6.
7.
8.
9.
0%
S D
SU
BM
IT
TA
L
J U
N E
G-101
GE
NE
RA
L N
OT
ES
PR
OJ
EC
T
IN
FO
RM
AT
IO
N
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AN
SI
D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
G P
D W
D W
M
AY
G -S er ie s Sh ee ts
.d w g
BU
IL
D
IN
G
L
IF
E
SA
FE
TY
EX
IT
S
IG
N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
IR
EC
TP
R A
TE
O
F
PU
B
LI
C W
O R
K S
(D
PW
G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
J
U N
E
112 112A
111A
113114
107107A
108A
116A
TROPIC
TROPIC
ARCTIC
ARCTIC
DORMITORY/
CLASS RM.
BOILER
AUX.
FIRE
OFFICE
TOOL
CRIB
101B
PIT ELECTRICAL
EQUIPMENT
AREA ELECTRICAL EQUIPMENT AREA
ELECTRICAL
EQUIPMENT
AREA
HEAVY MACHINERY
MECHANICAL EQUIPMENT
HEAVY
MACHINERY
DRESSING ROOM
CONDITIONING
KITCHEN
CONDITIONING
DRESSING ROOM
KITCHEN
STORES
CHAMBER
AIR LOCK
OBSERVATION
ROOM
CHAMBER
AIR LOCK
CHAMBER
AIR LOCK
THERMOCOUPLE
ROOM
TROPIC CHAMBERARCTIC CHAMBER
MEN'S
TOIL.
WOM.
TOIL.
AIR
LOCK
TOILET
SHOWER
STORAGE
STORAGE
SHOWER
OBSERVATION
ROOM
MEN
CONTROL ROOM
SHOWER
TOILET
CHAMBER
AIR LOCK
BLOOD RM
E
E
E
E
E
E
E
E
L1
P1 P2
L2 A
L2
L9
L6A L6
L3A
L3 L4
L5A L5
L8
L5
L5
L5
L4
L2
L1
L6
L3
L6
L6
L1
L4
C
C
C
C
C
C C
C
C
C
W
C
LIFE SAFETY LEGEND
E - EXISTING EXIT SIGN
W - WAL MOUNTED
C - CEILING MOUNTED
SINGLE FACE EXIT SIGN
SINGLE FACE EXIT SIGN, ARROW
INDICATES TRAVEL PATH
DOUBLE FACE EXIT SIGN, ARROW
INDICATES TRAVEL PATH
LIFE SAFETY NOTES
NEW EXIT SIGNS TIE INTO POWER SOURCE
INDICATED ON DRAWINGS. CONTRACTOR
CONFIRM AVALABLE CURCUITS.
LED EXIT SIGN
MOUNTING: UNIVERSAL
SHIELDING: FLAT SHEET ACRYLIC
BATTERY: SEALED MAINTENANCE FREE
NICKEL CADMIUM BATTERY
OTHER: SELF-DIAGNOSTIC TESTING,
TAMPERPROOF SCREWS.
NEMA PREMIUM EXIT SIGN
HOUSING: SOLID DIE-CAST ALUMINUM
HOUSING AND FACE
DIRECTIONAL CHEVRON
ARROW WERE INDICATED
FINISH: COLOR TO MATCH EXISTING
DIMENSIONS: 12-5/8" X 8-1/4" X 2" (L x W x H)
LF-100
LI
FE
S
AF
ET
Y
EX
IT
S
IG
N
LO
C
AT
IO
N
P
LA
N
3/32" = 1'-0"
1 PLAN: LIFE SAFETY-EXIT SIGN LOCATION PLAN
LF-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AN
SI
D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
G P
D W
D W
M
AY
Bl d
2_ Li fe S af et y Se rie s.
dw g
BU
IL
D
IN
G
L
IF
E
SA
FE
TY
EX
IT
S
IG
N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
New England District
US Army Corps of Engineers
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
IR
EC
TP
R A
TE
O
F
PU
B
LI
C W
O R
K S
(D
PW
G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
J
U N
E
| G-100 |
| Sheets and Views |
| G-100 Cover Sheet |
| G-101 |
| Sheets and Views |
| G-101 Gen Notes |
| LF-100 |
| Sheets and Views |
| LF-100 Life Safety Pln |
File details come from the government source that posted it. Updated .