This structural plan and details document outlines renovation work for Building 36 at the DEVCOM Soldier Center in Natick, Massachusetts. The contractor shall provide demolition and renovation work to create space for the Bureau of Engraving and Printing, including work in Room E166. Work includes removal and disposal of selected items as well as new architectural, mechanical, electrical, security and fire protection elements. The contractor must hire a licensed structural engineer to provide design drawings for all roof penetrations and a new CMU wall, footing and concrete slab. The drawings must include plans, details, notes and other information to ensure structural soundness per UFC/IBC codes upon project completion.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CALIBRATION SHOP
GRT PACKAGING LAB
PACKAGING LAB
MECHANICAL / ELECTRICAL
ROOM
STORAGE
CORRIDOR
MEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
OFFICES
E145
E146
E162 E163
E166
E167 E168
E144
E155E156
E158
E159
E160
E161
CALIBRATION SHOP
TREASURY
E153 E152
E149
E151
CALIBRATION SHOP
E166
E144
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
J
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
LM
46-7/8" / 12-5/8" RETURN DUCT
DOWN
34" / 26-3/4" SUPPY DUCT DOWN
7'- 5"
TO
C O
L
LI
NE
L
M
18'-0"±
TO COL LINE 3
2 4 56
STRUCTURAL KEY NOTES
NEW CMU WALL BELOW. SEE A-100.
NEW 15 TON RTU.
EXISTING STEEL FRAMED ROOF STRUCTURE
(TYPICAL). SHEET SHEET NO.: 35-06-02 30 OF
60 AS-BUILT DRAWING DATED 20 MAY 1966
FOR STRUCTURAL INFORMATION.
GENERAL CONTRACTOR SHALL HIRE A
MASSACHUSETTS LICENSED STRUCTURAL
ENGINEER TO PROVIDE DESIGN DRAWINGS
FOR ALL ROOF PENETRATIONS. THE DESIGN
DRAWINGS SHALL INCLUDE ALL PLANS,
DETAILS AND NOTES AND OTHER REQUIRED
INFORMATION TO PROVIDE A STRUCTURALLY
SOUND DESIGN THAT MEETS ALL UFC/IBC
CODES UPON COMPLETION OF THE PROJECT.
GENERAL CONTRACTOR SHALL COORDINATE
WITH ALL TRADES FOR SIZE OF ROOF
PENETRATION OPENING PRIOR TO
DEMOLITION WORK.
GENERAL CONTRACTOR SHALL HIRE A
MASSACHUSETTS LICENSED STRUCTURAL
ENGINEER TO PROVIDE DESIGN DRAWINGS
FOR NEW CMU WALL, FOOTING AND
CONCRETE SLAB. THE CMU WALL DETAILS 1, 5,
7 AND 12 ON SHEET A-300 SHOWS THE DESIGN
INTENT AND WALL AND FOOTING SIZES AS
WELL AS ALL ASSOCIATED REINFORCEMENT
AND LATERAL BRACING SHALL BE DESIGNED
BY THE STRUCTURAL ENGINEER. THE DESIGN
DRAWINGS SHALL INCLUDE ALL PLANS,
DETAILS AND NOTES AND OTHER REQUIRED
INFORMATION TO PROVIDE A STRUCTURALLY
SOUND DESIGN THAT MEETS ALL UFC/IBC
CODES UPON COMPLETION OF THE PROJECT.
SKS-100
ST
R
U C
TU
R
AL
R
O O
F
PL
N
AN
D C
M U
W
AL
L D
ET
AI
L
1/8" = 1'-0"
1 STRUCTURAL PLAN
S-101
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
St ru ct ur al S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
AD
D
EN
D U
M
1- C
AL
IB
R
AT
IO
N
R M
S O
W C
H
AN
G
ES
F
EB
AD
D
EN
D U
M
2-
ST
R U
C
TU
R
AL
S O
W C
H
AN
G
ES
M
AR
| Sheets and Views |
| S-101 Struct Roof Pln |