Bldg 36 BEP_100pct Set_2023.0720.pdf
PDF 4 MB Posted
- Attached to
- Bldg 36 Renovation
- Solicitation number
- W911QY-24-R-0004
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G-100
CO
VE
R
SH
EE
T
100% CORRECTED FINAL SUBMISSION
U.S. Army Soilder System Center
Building 36 Bureau of Engraving and Printing Renovation
TBD
NSSC
General Greene Avenue Natick, MA 01760
Project Name:
Solicitation No.:
Project Address:
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
G
-S er ie s
Sh ee ts .d w g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
General
G-100
G-101
Architectural
EX-100
LF-100
AD-100
A-100
A-101
A-102
A-300
A-500
Structural
S-100
Electrical
E-101
E-102
Mechanical
MD-100
M-100
M-101
Plumbing
P-100
Equipment
EQ-100
EQ-101
Process
PR-100
PR-101
Fire Protection
FXE-100
Fire Alarm
FA-100
Security
ES-100
Telecommunications
TN-100
Cover Sheet
Abbreviations, General Notes & Applicable Standards
Existing Conditions Plan
Life Safety Plan
Architectural Demolition Plan
Architectural Floor Plan
Reflected Ceiling Plan
Roof Plan
Wall Sections and Details
Door Schedule and Details
Structural Roof Plan
Electrical Power Plan
Electrical Lighting Plan
Mechanical Demolition Plan
Mechanical Plan
Mechanical Roof Plan
Plumbing Plan
Existing Equipment Plan
Equipment Relocation Plan
Air/Domestic Hot Water Relocation Plan
Condenser Water and Gas Relocation Plan
Fire Protection Existing Conditions Plan
Fire Alarm Plan
Access Control and Alarm Systems Plan
Telecommunication Data Plan
DRAWING INDEX:
AB
ACT
ADH
ADJ
ALUM
ARCH
BD
BLDG
BM
BO
BRNG
C
CAB
C.I.P.
CJ
CLR
CMU
COL
CONC
DED
DEG
DET
DIA
DIM
DN
DR
DTL
DWG
EA
EJ
EL
ELEC
EP
EQ
EW
EXP
EXT
F
FAB
FD
FE
FEC
FFE
FTG
FMG
GALV
GC
GR
HDW
HM
HORIZ
HR
HWD
ID
IN
INT
JB
JST
JT
ANCHOR BOLT
ACOUSTICAL TILE
ADHESIVE
ADJUSTABLE
ALUMINUM
ARCHITECT/ARCHITECTURAL
BOARD
BUILDING
BEAM
BOTTOM OF
BEARING
CELSIUS
CABNIET
CAST IN PLACE
CONTROL JOINT
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
DEDICATED
DEGREE
DETAIL
DIAMETER
DIMENSION
DOWN
DOOR
DETAIL
DRAWING
EACH
EXPANSION JOINT
ELEVATION
ELECTRICAL
ELECTRICAL PANEL
EQUAL
EACH WAY
EXPANSION
EXTERIOR
FARENHEIT
FABRICATED
FLOOR DRAIN
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FLOOR ELEVATION
FOOTING
FRAMING
GALVANIZED
GENERAL CONTRACTOR
GRADE
HARDWARE
HOLLOW METAL
HOIZONTAL
HOUR
HARDWARE
INSIDE DIAMETER
INCH
INTERIOR
JAMB
JOIST
JOINT
L
LF
LH
MAS
MAT
MAX
MFRS
MIN
MISC
MO
MTL
N N/A
NIC
NO
NOM
NTS
OC
OD
OPNG
OPP
P
PART
PC
FREFAB
PSF
PSI
QTY
R
REF
REINF
REQ'D
REV
RH
RO
SCHED
SECT
SF
SHT
SIM
SQ
STD
STL
STRUCT
SUSP
T/..
TEMP
THK
TYP
UL
UNO
VERT
W/
WD
WWF
LENGTH
LINEAR FEET
LEFT HAND
MASONRY
MATERIAL
MAXIMUM
MANUFACTURER
MINIMUM
MISCELLANEOUS
MASONRY OPENING
METAL
NORTH
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OPENING
OPPSITE
PLATE
PARTITION
PRE CAST
PRE FABRICATED
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
QUANTITY
RADIUS
REFERENCE
REINFORCED(MENT)
REQUIRED
REVISION
RIGHT HAND
ROUGH OPENING
SCHEDULE
SECTION
SQUARE FOOT
SHEET
SIMILAR
SQUARE
STANDARD
STEEL
STRUCTURAL
SUSPENDED
TOP OF ...
TEMPERATURE
THICK
TYPICAL
UNDERWRITERS LABORATORY
UNLESS NOTED OTHERWISE
VERTICAL
WITH
WOOD
WELDED WIRE FABRIC
ABBREVIATIONSMATERIALS AND SYMBOLS
CONCRETE
EARTH
GRAVEL
PRE CAST CONCRETE
CMU
BRICK
STEEL, IRON
A7
A7
DETAIL
NUMBER
SECTIONAL INDICATION
DIRECTION
SHEET
NUMBER
A7
DRAWING
REVISION NUMBER
DETAIL
NUMBER
SHEET
NUMBER
COLUMN INDICATOR
EXTERIOR ELEVATION
PHOTOGRAPH KEY
CONTRACTOR SHALL DIRECT ALL QUESTIONS, REQUESTS FOR INFORMATION, OR SHOP
DRAWINGS ON ITEMS IN THE PLAN TO THE ENGINEER OF RECORD.
CONTRACTOR SHALL VISIT SITE AND BECOME FAMILIAR WITH THE PROJECT AND
CONDITIONS AFFECTING THE WORK. NO ADDITIONAL PAYMENT WILL BE MADE ON CLAIMS
THAT ARISE FROM LACK OF KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL
BE HELD TO HAVE EXAMINED THE SITE SO AS TO COMPARE FIELD CONDITIONS WITH THE
DRAWINGS AND SPECIFICATIONS. NO ALLOWANCE SHALL BE MADE TO THE CONTRACTOR
BY REASON OF THEIR FAILURE TO HAVE MADE EXAMINATION OR MANY ERROR ON THEIR
PART.
CONTRACTOR SHALL NOTIFY CONTRACTING OFFICERS REPRESENTATIVE (COR), IN
WRITING, OF DISCREPANCIES FOUND ON THE DRAWINGS PRIOR TO CONSTRUCTION.
ALL DIMENSIONS SHALL BE READ OR CALCULATED, NOT SCALED.
ALL DIMENSION SHALL BE VERIFIED AT SITE AND ANY DISCREPANCIES SHALL BE REPORTED
BY THE CONTRACTOR TO THE COR PRIOR TO ORDERING MATERIALS AND PROCEEDING THE
THE WORK. ANY OMISSIONS OR INCONSISTENCIES ON THESE DRAWINGS OR ANY
VARIATIONS OR AMBIGUITIES BETWEEN THESE DRAWINGS, AND ACTUAL SITE AND
CONSTRUCTION CONDITIONS AND/OR REQUIREMENTS SHALL BE BROUGHT TO THE
ATTENTION OF THE ENGINEER OF RECORD IN WRITING AND RESOLVED AND DOCUMENTED
IN WRITING BEFORE CONTINUING WITH THE WORK IN QUESTION.
ALL CONSTRUCTION DEBRIS SHALL BE LAWFULLY DISPOSED OF AT A SANITARY LANDFILL.
ALL WORK SHALL BE PREFORMED IN A WORKMANLIKE MANNER WITH MATERIALS INSTALLED
PER MANUFACTURER'S SPECIFICATIONS.
"TYPICAL" MEANS THE REFERENCED DETAIL SHALL APPLY FOR ALL SIMILAR CONDITIONS
UNLESS OTHERWISE NOTED.
NOTE THAT THIS IS AN EXISTING FACILITY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
VISIT THE SITE AND VERIFY EXISTING CONDITIONS FOR NEW WORK PRIOR TO MATERIAL
PURCHASE, FABRICATION AND INSTALLATION.
1.
GENERAL NOTES
VICINITY MAP
2.
3.
4.
5.
6.
7.
8.
9.
/6 5%
D D
SU
BM
IT
TA
L
/1 6/
G-101
GE
NE
RA
L N
OT
ES
PR
OJ
EC
T
IN
FO
RM
AT
IO
N
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
G
-S er ie s
Sh ee ts .d w g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
PROJECT LOCATION:
BUILDING 36
0%
C D
SU
BM
IT
TA
L
J U
LY
CALIBRATION SHOP
GRT PACKAGING LAB
PACKAGING LAB
MECHANICAL / ELECTRICAL
ROOM
STORAGE
CORRIDOR
MEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
E145
E146
E162 E163
E167 E168
E144
E155E156
E158
E159
TREASURY
E153 E152
E149
E151
CALIBRATION SHOP
E166
E1
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
J
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
EX-100
EX
IS
TI
N
G C
O N
D
IT
IO
N
PL
AN
1/8" = 1'-0"
1 EXISTING CONDITION PLAN
EX-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Ar ch ite ct ur al
S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
WAREHOUSE
S-1 500 5
2212 SF 1
36"
75'-2"
MT-100
CALIBRATION SHOP
GRT PACKAGING LAB
MECHANICAL
ROOMCONTROLLED TEMP BOXES
PACKAGING LAB
MECHANICAL
STORAGE
CORRIDOR
STOKES
MEN
WOMEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
SPICE ROOM
CONTR. TEMP.
STORAGE
E125
E123
E122
E145
E146
E162 E163
E167 E168 E170
E144
E155E156
E157
E158
E159
TREASURY
BOXES
E154
E153 E152
E153A
E149
E148
E124 E151
CALIBRATION SHOP
E166 ELEV MEC
COM
DATA
TELE
E142
E143
E144
19'-2"±
EXISTING
2 3 4 5 6 7 8 9
Q
P
N
M
L
K
J
H
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-2
EX
IS
TI
NG
TREASURY
E149A
MEZZANINE
715 sqft +/-
2212 sqft +/-
ELECTRICAL
ROOM
WAREHOUSE
S-1 500 2
712 SF 1
68'-0"
MT-100
FE
(E)
FE
(E)
FE
FE
FIRE EXTINGUISHER. (E) INDICATES EXISTING
1 HOUR FIRE RATED WALL IS INDICATED BY -
EGRESS POINT
PATH OF TRAVEL
MAXIMUM TRAVEL
ROOM OCCUPANCY TAG
DOOR EGRESS TAG
STAIR EGRESS TAG
LIFE SAFETY NOTES
ROOM NAME
R-2 100 5
900 SF 1
36"
44"
NUMBER OF OCCUPANTS
REQ NO. OF EXITS
OCCUPANT FACTOR
ROOM AREA
OCCUPANCY CLASSIFICATION
NO. OF OCCUPANTS
WIDTH OF DOOR
ALLOWABLE EXIT CAPACITY
NO. OF OCCUPANTS
WIDTH OF STAIR
ALLOWABLE EXIT CAPACITY
LENGTH
MT-A
APPLICABLE CODES:
OCCUPANCY CLASSIFICATION:
SPRINKLED:
MAXIMUM OCCUPANCY:
MAXIMUM PATH OF TRAVEL:
CODE SUMMARY
UFC, 2021 IEBC, 2021 IBC, NFPA
S-2 (WAREHOUSE)
YES
29 PPL (ACTUAL 7 PPL)
100 FT (ACTUAL 75'-2")
FE
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Li fe
S af et y
Se rie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
LF-100
LI
FE
S
AF
ET
Y
PL
AN
1/8" = 1'-0"
1 LIFE SAFETY PLAN
LF-100
AutoCAD SHX Text
OVERHEAD
AutoCAD SHX Text
DOOR
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
ACID
AutoCAD SHX Text
WASTE
AutoCAD SHX Text
PUMP
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
PACKAGING LAB
MECHANICAL
STORAGE
CORRIDOR
MEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
E145
E146
E162 E163
E167 E168
E144
E155E156
E159
TREASURY
E153 E152
E149
E151
CALIBRATION SHOP
E166
E144
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
J
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
MEZZANINE
715 sqft +/-
2212 sqft +/-
ELECTRICAL
ROOM
2 2 2
5 5 5 5
6 6
7 77
4'-0"
10 11 14
11 14
DEMOLITION KEY NOTES
REMOVE DOOR, FRAME AND ALL ASSOCIATED
COMPONENTS IN ITS ENTIRETY
REMOVE WALL, FRAMING AND ALL
ASSOCIATED COMPONENTS IN ITS ENTIRETY
REMOVE STEEL BEAM. BEAM SHALL BE
REMOVED AT BOLTED CONNECTION OF
COLUMN TO REMAIN
REMOVE STEEL COLUMNS. CUT COLUMNS TO
BELOW FACE OF CONCRETE
REMOVE STEEL BEAMS.
REMOVE ASBESTOS WALL PANELS
RELOCATED ALL UTILITY LINES AND PIPES IN
AREAS INDICATED
REMOVE CONCRETE SLAB AND SUB GRADE
TO ACCOMMODATE 12" CONCRETE FOOTING
AND 6" GRAVEL BASE. SEE SHEET A-100 AND
A-300 FOR MORE INFORMATION
REMOVE PORTION OF CHAIN LINK AS
INDICATED
MOVE EXISTING METAL SHELVING UNITS TO
LOCATION WITHIN THE REFERENCED SPACE
FOR RELOCATION
MOVE EXISTING FURNITURE TO LOCATION
WITHIN THE REFERENCED SPACE FOR
RELOCATION
MOVE EXISTING SINK. SEE PLUMBING
DRAWINGS
REMOVE AND RELOCATE TO NEW CMU WALL.
SEE ELECTRICAL DRAWINGS
REMOVE ASBESTOS FLOOR TILE, GRIND TO
CONCRETE
REMOVE SUBMERGED VIBRATING TABLE,
MOTORS AND ALL ASSOCIATED COMPONENTS
IN ITS ENTIRETY
SEE EQ-100 AND EQ-101 FOR EXISTING
EQUIPMENT TO BE RELOCATED
AD-100
D
EM
O
LI
TI
O
N P
LA
N
A N
D
PH
O
TO
G R
AP
H
S
1/8" = 1'-0"
1 ARCHITECTURAL DEMOLITION PLAN
AD-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Ba se
_F lo or P la ns
.d w g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
4 4
4 4 4
5 5 5
3 9
83 9
CALIBRATION SHOP
GRT PACKAGING LAB
PACKAGING LAB
MECHANICAL / ELECTRICAL
ROOM
STORAGE
CORRIDOR
MEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
OFFICES
E145
E146
E162 E163
E167
E168
E144
E155E156
E159
E160
E161
TREASURY
E153 E152
E149
E151
CALIBRATION SHOP
E166
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
J
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
FAP
FA
FA
SD SDSD
FA FA
RCP DEMOLITION KEY NOTES
REFLECTIVE CEILING PLAN LEGEND
2 X 4 RECESSED
LIGHT
ROOF MOUNTED
LIGHT
UNDER STEEL
MOUNTED LIGHT
ACOUSTICAL CEILING GRID
HVAC SUPPLY DIFFUSER
HVAC RETUREN DIFFUSER
SEE ELECTRICAL DRAWINGS FOR PRODUCT
TYPE AND ELECTRICAL REQUIREMENTS.
REMOVE WALL. SEE SHEET AD-100
REMOVE ASBESTOS WALL PANELS. SEE
SHEET AD-100
REMOVE ACT TILES, GRID AND ALL
ASSOCIATED COMPONENTS IN ITS ENTIRTY
REMOVE AND STORE ROOF HUNG LIGHT
FIXTURES. SEE ELECTRICAL DRAWINGS
REMOVE AND STORE UNDER STEEL FRAMING
HUNG LIGHTS FIXTURES. SEE ELECTRICAL
DRAWINGS
REMOVE DUCT WORK. SEE MECHANICAL
DRAWINGS
REMOVE CORRUGATED METAL ROOF AND ALL
ASSOCIATED THERMAL AND WEATHER
PROOFING MATERIAL TO ACCOMMODATE NEW
ROOF TOP UNIT AND DUCT WORK. SEE
STRUCTURAL AND MECHANICAL DRAWINGS
FOR MORE INFORMATION
REMOVE RECESSED LIGHTS, SEE ELECTRICAL
DRAWINGS FOR MORE INFORMATION
REMOVE HVAC SUPPLY AND RETURN GRILLS.
SEE MECHANICAL DRAWINGS FOR MORE
INFORMATION
AD-101
R C
P D
EM
O
LI
TI
O N
P
LA
N
1/8" = 1'-0"
1 ARCHITECTURAL DEMOLITION REFLECTED CEILING PLAN
AD-101
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Ar ch ite ct ur al
S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
PACKAGING LAB
MECHANICAL
STORAGE
CORRIDOR
MEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
E145
E146
E162 E163
E167 E168
E144
E155E156
E159
TREASURY
E153 E152
E149
E151
CALIBRATION SHOP
E166
E144
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
J
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
MEZZANINE
715 sqft +/-
2212 sqft +/-
ELECTRICAL
ROOM
70'-9"
6'- 9"
'-3
2 3
A-300
ALIGN
2'- 0"
'-0
3'-
1"
5 16'-0" 6'-0"
GATE OPENING 53'-0"
9'-
6'-0"
14'-0" 6'-0"
GATE OPENING
888 8
A-300
A-300
A-300
UP
149A-1
149A-2
149A-3
163-1
14 14
A300
A300
CJ CJ
FE
(E)
FE
(E)
FE16
16FE 17 131317 17
ARCHITECTURAL KEY NOTES
PATCH WALL TO MATCH ADJACENT EXISTING
WALL
PREP EXISTING FLOOR TO LEVEL PRIOR TO
FINAL FINISH
EPOXY FLOORING. DUR-A-QUARTZ EPOXY
BROADCAST WITH URETHANE TOPCOAT.
PROVIDE ISOLATION MEMBRANE BETWEEN
EPOXY AND CONCRETE SLAB. MEMBRANE PER
EPOXY MANUFACTURES RECOMMENDATIONS.
NOT USED
PRIME AND PAINT WALLS
PREPARE AND INSTALL SALVAGED WIRE MESH
DOOR TO NEW LOCATION
RELOCATE STORED METAL SHELVING UNITS
RELOCATE STORED CUBICLES. RECONNECT
ALL DATA AND ELECTRICAL TO OUTLETS
RELOCATE SINK AND MILLWORK. SEE
PLUMBING DRAWINGS
RELOCATE ELECTRIAL PANELS. SEE
ELECTRICAL DRAWINGS
FIRE ALARM AND STROBE. SEE FIRE ALARM
DRAWINGS
FIRE ALARM PULL STATION. SEE FIRE ALARM
DRAWINGS
PALLET STORAGE RACKS. CONTRACTOR TO
MOVE FROM BUILDING 20 AND INSTALL IN NEW
LOCATION INDICATED, COORDINATE WITH
DMST PERSONAL
GOVERNMENT FURNISHED, GOVERNMENT
INSTALLED EQUIPMENT. CONTRACTOR TO
COORDINATE ELECTRICAL AND COMPRESSED
AIR INSTALLATION. SEE ELECTRICAL
DRAWINGS FOR POWER REQUIREMENTS AND
SEE PROCESS DRAWINGS FOR COMPRESSED
AIR REQUIREMENTS
FLOOR INFILL: 4" CONCRETE SLAB (MATCH
EXISTING THICKNESS) 8" CRUSHED GRAVEL,
REMAINING TO BE BACKFILLED WITH GRAVEL
MIXTURE TO ACCOMMODATE 95%
COMPACTION (PROCTOR DENSITY)
PROVIDE WALL MOUNTED FIRE
EXTINGUISHER.
PALLET STORAGE RACKS. CONTRACTOR TO
MOVE FROM E-149. SEE SHEET EQ100 AND
EQ101 FOR MORE INFORMATION
INTERIOR PARTITIONS - ALL DIMENSIONS ARE FROM CENTER LINE
OF WALL STUD FRAMING UNLESS NOTED OTHERWISE
WINDOWS - ALL DIMENSION ARE FROM CENTER LINE OF WINDOW
DOORS - DOOR LOCATION ARE AS SHOW IN TYP 5" DOOR OFFSET
FROM HINGE SIDE. UNLESS DIMENSIONED OTHERWISE
1.
2.
3.
DIMENSION NOTES:
1 HOUR FIRE RATED WALL IS INDICATED BY -
SEE PLANS AND DETAILS FOR ADDITIONAL INFORMATION
EXISTING FIRE EXTINGUISHER INDICATED BY
1.
2.
LIFE SAFETY NOTES:
FE
(E)
A-100
FL
O
O R
P
LA
N S
1/8" = 1'-0"
1 ARCHITECTURAL FLOOR PLAN
A-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Ba se
_F lo or P la ns
.d w g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
A-300
4 4
4 4
4 4 4 4 4
CALIBRATION SHOP
GRT PACKAGING LAB
PACKAGING LAB
MECHANICAL / ELECTRICAL
ROOM
STORAGE
CORRIDOR
MEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
OFFICES
E145
E146
E162 E163
E167
E168
E144
E155E156
E159
E160
E161
TREASURY
E153 E152
E149
E151
CALIBRATION SHOP
E166
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
J
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
FAP
FA
FA
SD SDSD
FA FA
REFLECTED CEILING PLAN KEY NOTES
ACOUSTICAL CEILING SYSTEM. TILE:
ARMSTRONG SCHOOL ZONE FINE FISSURE,
24"X24" ANGLED REGULAR WHITE TILE. GRID:
PRELUDE XL 15/16" EXPOSED TEE, WHITE
PROVIDE FIRE SPRINKLER HEADS AS NEEDED
PER UFC AND NFPA REQUIREMENTS. SEE FIRE
PROTECTION DRAWING.
HVAC SUPPLY AND RETURN DUCTS. SEE
MECHANICAL DRAWINGS
ROOF AND UNDER MEZZANINE LIGHTS. SEE
ELECTRICAL DRAWINGS
LED EXIT SIGN. SEE ELECTRICAL DRAWINGS
POLE MOUNTED SMOKE DETECTORS. SEE
FIRE ALARM DRAWINGS
FIRE ALARM AND STROBE. SEE FIRE ALARM
DRAWINGS
POLE MOUNTED SMOKE DETECTOR. SEE FIRE
ALARM DRAWINGS
HVAC SUPPLY AND RETURN GRILLS. SEE
MECHANICAL DRAWINGS
24"X24" RECESSED LIGHTS. SEE ELECTRICAL
DRAWINGS
DROP EXISTING SPRINKLER HEADS TO NEW
ACOUSTICAL CEILING SYSTEM
REFLECTIVE CEILING PLAN LEGEND
RECESSED LIGHT
RELOCATED ROOF MOUNTED
LIGHT
RELOCATED UNDER MEZZANINE
MOUNTED LIGHT
EXIT SIGN
FIRE ALARM WITH STROBE
FIRE ALARM PULL STATION
POLE MOUNTED SMOKE
DETECTOR
HVAC SUPPLY DIFFUSER
HVAC RETUREN DIFFUSER
FA
FAP
SD
A-101
R
EF
LE
C
TE
D
C
EI
LI
N
G
PL
AN
1/4" = 1'-0"
1 REFLECTED CEILING PLAN
A-101
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Ar ch ite ct ur al
S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
J
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
M101
SEE M-101 FOR
RTU INFORMATION
A-102
R O
O F
PL
AN
1/4" = 1'-0"
1 ROOF PLAN
A-102
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Ba se
_F lo or P la ns
.d w g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
8" CMU
TOC
EL. EXISTING
2'- 0"
SP
LI
CE
M
IN
#5 VERTICAL REBAR, 24" O.C.
GROUT EACH CAVITY SOLID
(E) CONCRETE SLAB (TYP)
CONCRETE SLAB (TYP)
16" X 12" FOOTING
6" GRAVEL BASE (3) #5 REBAR AT BOTTOM
#5 REBAR BENT AS INDICATED,
MATCH VERTICAL BARS FOR
SPACING
#5 HORIZONTAL REBAR AND
TRUSS REINFORCEMENT, 16" O.C.
EXISTING ROOF SYSTEM
PARTITION
5/8" GWB
6" METAL STUD, 16" O.C.
MINERAL WOOL INSULATION
5/8" GWB
EXISTING ROOF TRUSS SYSTEM
BOTTOM TRACK. 6" TRACK,
MECHANICALLY ATTACHED TO
CMU WALL
TOP TRACK.
SLOTTED DEFLECTION TRACK,
ATTACHED TO CORRUGATED
ROOF
BEP SIDEPACKAGING
LAB SIDE
BOTTOM OF ROOF DECK
BOTTOM OF SOFFET
EL: - 2"
ACT CEILING
EL: EXISTING
EL: 20'-0" +/-
5/8 GWB EACH SIDE
3-5/8 MTL STUD SOFFIT, 16" OC
6"
2'- 0"
4'-0" 2 3-1/2" x 3-1/2" x 1/4"
10'-0" 2 6" x 3-1/2" x 3/8"
SEE LINTEL SCHEDULE
MAXIMUM
OPENING
8" THICK CMU WALL
LINTEL NOTES:
PROVIDE AND INSTALL LINTEL ANGLES FOR MASONRY OPENINGS
IN ACCORDANCE WITH THE SCHEDULE ABOVE. INSTALL LONG
LEG VERTICAL.
PROVIDE 6" MINIMUM BEARING AT EACH END BUT NOT LESS
THAN 1" PER FOOT OF SPAN. FILL 2 COURSES OF MASONRY
BELOW BEARING WITH GROUT.
2 CONTINUOUS #5 BARS
AT OPENINGS
BENT BARS
AT OPENINGS
MASONRY OPENING CORNERTYPICAL DETAIL
2'-0" LOCATED IN CENTER OF CAVITY
# 5 HORIZONTAL BARS
LADDER TRUSS TYPE WALL
REINFORCING WHERE SHOWN ON
SCHEDULE OR NOTES. TYPICAL
PROVIDE ADDITIONAL
VERTICAL BARS AT
CORNER
PROVIDE HORIZONTAL CORNER
BARS AT ALL WALLS TO MATCH
HORIZONTAL REINFORCING
ADDITIONAL VERTICAL
REINFORCING
MASONRY
OPENING
EXISTING THERMAL AND
WEATHER SYSTEM
STRUCTURAL TO PROVIDE NEW
FRAMING FOR ROOF
PENETRATIONS
EXISTING ROOF TRUSS
SYSTEM BEYOND
RTU. SEE
MECHANICAL
DRAWINGS
RTU CURB.
MANUFACTURER: CARRIER
MODEL NO.: CRRFCURB002A01 (24" HIGH)
RTU CURB NOTE:
CONTRACTOR SHALL COORDINATE WITH MECHANICAL
CONTRACTOR FOR SIZE OF OPENINGS PRIOR TO
CUTTING INTO THERMAL ROOF SYSTEM AND
CORRUGATED METAL.
EXISTING THERMAL AND WATER PROOFING SYSTEM WAS
INSTALLED FEBRUARY 2006 AND THE ROOF WARRANTIES
FOR THIS WORK ARE IN PLACE. CONTRACTOR SHALL
CONTACT ROOF MANUFACTURERS REPRESENTATIVE FOR
RECOMMENDATIONS AND DETAILS PERTAINING TO NEW
ROOF PENETRATIONS SO THE EXISTING WARRANTY IS
NOT VOIDED. CONTRACTOR SHALL HAVE WORK
INSPECTED BY EPDM MANUFACTURES REPRESENTATIVE
TO FOR COMPLIANCE AND APPROVAL OF WORK.
EXISTING EPDM
MEMBRANE
8" X 16" RUBBER WALK PAD
UNDER WOOD BLOCKING
6" X 6" X 12" PT WOOD
BLOCKING. ADD ADDITIONAL
BLOCKING WHERE ROOF
SLOPES TO PROVIDE A RUN
WITH NO SEVER BENDS IN
PIPE
GAS PIPE OR ELECTRICAL
CONDUIT
U-CLAMP SECURED TO WOOD
BLOCKING
EXISTING THERMAL AND
WEATHER SYSTEM
STRUCTURAL TO PROVIDE
NEW FRAMING FOR ROOF
PENETRATIONS
COUNTER FLASHING
ATTACHED TO CURB
FACTORY INSTALLED
WOOD BLOCKING
1" RIGID INSULATION
ATTACHED TO CURB
EPDM SHEET FLASHING,
INSTALLED PER EPDM
MANUF. RECOMMENDATIONS
LAP SEALANT
EXISTING EPDM WRAPPED
UP CANT STRIP
CANT STRIP
EXISTING ROOF TRUSS
SYSTEM BEYOND
RTU. SEE MECHANICAL
DRAWINGS
DETAIL NOTE:
FLASHING IS TYPICAL ON ALL
FOUR SIDES OF RTU CURB
MANUFACTURED RTU CURB
VERTICAL REINFORCING
ON EACH SIDE OF JOINT TO
MATCH WALL REINFORCING
CONTROL JOINT WITH FULL
HEIGHT BACKER ROD AND
SEALANT. ON EACH SIDE3/8" JOINT
CMU WALL
PREMOLDED CONTROL
JOINT KEY
CONTROL JOINT NOTES:
1.
2.
CONTROL JOINTS SHALL EXTEND FULL
HEIGHT OF CMU WALL.
JOINT REINFORCEMENT SHALL BE
DISCONTINUOUS AT CONTROL JOINTS
A-300
M
IS
C
EL
LA
N
EO
U
S D
ET
AI
LS
1-1/2" = 1'-0"
1 DETAIL - CMU WALL
A-300
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Ar ch ite ct ur al
S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
1-1/2" = 1'-0"
A-300
DETAIL - CMU WALL
1-1/2" = 1'-0"
A-300
DETAIL - WALL OPENING
1-1/2" = 1'-0"
A-300
DETAIL - SOFFIT
1" = 1'-0"
A-300
DETAIL - RTU CURB
3" = 1'-0"
A-300
DETAIL - PIPE / CONDUIT SUPPORT
1=1/2" = 1'-0"
A-300
ENLARGED DETAIL - RTU CURB
1-1/2" = 1'-0"
A-300
DETAIL - CMU CONTROL JOINT
WALL TYPE PER PLAN
VARIES
BOX HEADER AT OPENING
DOOR FRAME PER SCHEDULE
DOOR PER SCHEDULE
APPLY CAULKING AT GWB, EACH SIDE OF
FRAME AROUND FRAME PERIMETER
WALL TYPE PER PLAN
VARIES
DOUBLE METAL JAMB STUDS
DOOR FRAME PER SCHEDULE
DOOR PER SCHEDULE
APPLY CAULKING AT GWB, EACH SIDE OF
FRAME AROUND FRAME PERIMETER
DOOR TYP 2"2"
D O
O R
T
YP
2"
SEE SCHED
SE
E
SC
H
ED
SEE SCHED
SE
E
SC
H
ED
TYPE A TYPE B TYPE 1
DOOR FRAME PER SCHEDULE
DOOR PER SCHEDULE
APPLY CAULKING AT CMU, EACH SIDE OF
FRAME AROUND FRAME PERIMETER
FILL DOOR FRAME WITH MINERAL WOOL
INSULATION
WALL TYPE PER PLAN
WALL TYPE PER PLAN
8"
DOOR FRAME PER SCHEDULE
DOOR PER SCHEDULE
APPLY CAULKING AT CMU, EACH SIDE OF
FRAME AROUND FRAME PERIMETER
FILL DOOR FRAME WITH MINERAL WOOL
INSULATION
DOOR PER SCHEDULE
OVERHEAD DOOR HOOD AND COIL
CONTAINER. INSTALL PER
MANUFACTURERS INSTRUCTIONS
WALL TYPE PER PLAN
EXISTING EXTERIOR INSULATION
WALL PANEL SYSTEM
EXISTING
DOOR PER SCHEDULE
OVERHEAD DOOR HOOD AND COIL
CONTAINER. INSTALL PER
MANUFACTURERS INSTRUCTIONSNEW STAINLESS STEEL WALL
CLOSURE
2"
WALL TYPE PER PLAN
8"
DOOR PER SCHEDULE
OVERHEAD DOOR TRACK. INSTALL PER
MANUFACTURERS INSTRUCTIONS
EXISTING EXTERIOR INSULATION
WALL PANEL SYSTEM
EXISTING
DOOR PER SCHEDULE
NEW STAINLESS STEEL WALL
CLOSURE
2"
OVERHEAD DOOR TRACK. INSTALL PER
MANUFACTURERS INSTRUCTIONS
A-500
D O
O R
S C
H
ED
U
LE
A N
D D
ET
AI
LS
1-1/2" = 1'-0"
1 DETAIL - DOOR HEAD
A-500
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Ar ch ite ct ur al
S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
3/8" = 1'-0"
A-300
TYPES - DOORS AND FRAMES
1-1/2" = 1'-0"
2 DETAIL - DOOR JAMB
A-500
1-1/2" = 1'-0"
3 DETAIL - DOOR HEAD
A-500
1-1/2" = 1'-0"
5 DETAIL - DOOR JAMB
A-500
1-1/2" = 1'-0"
6 DETAIL - DOOR HEAD
A-500
1-1/2" = 1'-0"
8 DETAIL - DOOR HEAD
A-500
1-1/2" = 1'-0"
12 SCHEDULE - DOOR
A-500
1-1/2" = 1'-0"
4 DETAIL - DOOR JAMB
A-500
1-1/2" = 1'-0"
11 DETAIL - DOOR JAMB
A-500
CALIBRATION SHOP
GRT PACKAGING LAB
PACKAGING LAB
MECHANICAL / ELECTRICAL
ROOM
STORAGE
CORRIDOR
MEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
OFFICES
E145
E146
E162 E163
E166
E167 E168
E144
E155E156
E158
E159
E160
E161
CALIBRATION SHOP
TREASURY
E153 E152
E149
E151
CALIBRATION SHOP
E166
E144
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
J
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
LM
46-7/8" / 12-5/8" RETURN DUCT
DOWN
34" / 26-3/4" SUPPY DUCT DOWN
7'- 5"
TO
C O
L
LI
NE
L
M
18'-0"±
TO COL LINE 3
2 4 5
STRUCTURAL KEY NOTES
NEW CMU WALL BELOW. SEE A-100
NEW 15 TON RTU
EXISTING STEEL FRAMED ROOF STRUCTURE
(TYPICAL). SHEET SHEET NO.: 35-06-02 30 OF
60 AS-BUILT DRAWING DATED 20 MAY 1966
FOR STRUCTURAL INFORMATION
GENERAL CONTRACTOR SHALL HIRE A
MASSACHUSETTS LICENSED STRUCTURAL
ENGINEER TO PROVIDE DESIGN DRAWINGS
FOR ALL ROOF PENETRATIONS. THE DESIGN
DRAWINGS SHALL INCLUDE ALL PLANS,
DETAILS AND NOTES AND OTHER REQURIED
INFORMATION TO PROVIDE A STRUCTURALLY
SOUND DESIGN THAT MEETS ALL UFC/IBC
CODES UPON COMPLETION OF THE PROJECT
GENERAL CONTRACTOR SHALL COORDINATE
WITH ALL TRADES FOR SIZE OF ROOF
PENETRATION OPENING PRIOR TO
DEMOLITION WORK
S-101
ST
R
U C
TU
R
AL
R
O O
F
PL
AN
1/8" = 1'-0"
1 STRUCTURAL ROOF PLAN
S-101
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
St ru ct ur al S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
AT
FLOOR
CALIBRATION SHOP
PACKAGING LAB
MECHANICAL / ELECTRICAL
ROOM
STOR
CO
RR
ID
O
R
TREASURY
STOR
OFFICES
E1
E1
E162 E163
E166
E167 E168
E160
E161
CALIBRATION SHOP
TREASURY
E149
CALIBRATION SHOP
E166
19'-2"±
EXISTING
2 3 4 5 6
Q
P
N
M
L
K
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
MEZZANINE
AT
MEZZ
AT
FLOOR
AT
MEZZ
AT
FLOOR
P4L4
(E) ELECTRICAL
PP10
AT
FLOOR
AT
FLOOR
4 4
EXISTING POWER FOR
SHAKE TABLE. POWER
SOURCE IS FLOOR MOUNTED
WITH OVERHEAD CABLE EXISTING POWER FOR
VERTICAL PRESS.
POWER SOURCE LOCATED
AT TRUSS LEVEL
EXISTING POWER
FOR CUTTING
MACHINE
RELOCATED
POWER FOR
PRESS TABLE
RELOCATED
POWER FOR
SHAKE TABLE
RELOCATED
POWER FOR
VERTICAL PRESS
EXISTING POWER
FOR PRESS.
POWER SOURCE
LOCATED ON WALL
ELECTRICAL GENERAL NOTES
1.
2.
3.
4.
CIRCUIT NUMBERS SHALL BE DETERMINED IN
THE FIELD AND REFLECTED ON AS-BUILT
DOCUMENTS BY THE ELECTRICAL
CONTRACTOR. THE ASSOCIATED CIRCUIT
NUMBERS THAT ARE APPLIED TO EACH
DEVICE INFERS INTERCONNECTING BRANCH
CIRCUITRY. INTERCONNECTING BRANCH
WIRING SHALL BE SIZED EQUAL TO THE
HOMERUN UNLESS NOTED OTHERWISE.
POWER BRANCH CIRCUITRY SHALL BE
INSTALLED IN CONDUIT FROM THE PANEL TO
THE FIRST DEVICE AND/OR WHERE EXPOSED.
POWER BRANCH CIRCUITRY MAY BE TYPE MC
CABLE WHERE CONCEALED ABOVE
SUSPENDED CEILINGS AND IN METAL STUD
WALLS.
SWITCHBOARDS, PANEL BOARDS, METER
SOCKET ENCLOSURES AND MOTOR CONTROL
CENTERS SHALL BE FIELD MARKED TO WARN
QUALIFIED PERSONS OF POTENTIAL ELECTRIC
ARC FLASH HAZARDS. THE MARKING SHALL BE
LOCATED SO AS TO BE CLEARLY VISIBLE TO
QUALIFIED PERSONS BEFORE EXAMINATION,
ADJUSTMENT, SERVICING OR MAINTENANCE
OF THE EQUIPMENT.
ALL DEVICES ARE SHOWN AS NEW, UNLESS
NOTED OTHERWISE.
ELECTRICAL LEGEND
DUPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
ELECTRICAL KEY NOTES
ROOM E149 POWER. ALL OUTLETS TO BE
POWERED EXISTING PANEL SOURCE.
REMOVE EXISTING PANELS FROM WALL AND
RELOCATE ON NEW CMU WALL.
RELOCATE ALL WALL MOUNTED POWER
SOURCES ON NEW CMU WALL
GOVERNMENT FURNISHED, GOVERNMENT
INSTALLED (GFGI) EQUIPMENT
E-100
EL
EC
TR
IC
AL
P
O W
ER
PL
AN
1/8" = 1'-0"
1 ELECTRICAL POWER PLAN
E-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
El ec tri ca l S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
PACKAGING LAB
MECHANICAL / ELECTRICAL
ROOM
CO
RR
ID
O
R
TREASURY
OFFICES
E162 E163
E166
E167
E160
E161
CALIBRATION SHOP
TREASURY
E149
CALIBRATION SHOP
E166
19'-2"±
EXISTING
2 3 4 5 6
Q
P
N
M
L
K
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
MEZZANINE
(E) (E)
(E) (E)
(E) (E) (E) (E) (E)
UNDER MEZZ
UNDER MEZZ
UNDER MEZZ
UNDER MEZZ
UNDER MEZZ
UNDER MEZZ
P4L4
L3
L2
2 2
(E)
ELECTRICAL GENERAL NOTES
1.
2.
3.
4.
ELECTRICAL CONTRACTOR SHALL BE
RESPONSIBLE FOR COORDINATING AND
CONFIRMING LOCATIONS AND MOUNTING
HEIGHTS OF ALL RELOCATED FIXTURES,
SWITCHES AND OTHER DEVICES WITH
ARCHITECT.
ALL EXIT SIGNS AND EMERGENCY BATTERY
BOXES SHALL BE UNSWITCHED AND
POWERED FROM CONSTANT POWER SOURCE.
ALL LIFE SAFETY DEVICES ARE SHOWN NEW
UNLESS NOTED WITH (E).
ALL LIGHTING INDICATED LIGHTING IS
RELOCATED FROM SALVAGED LIGHTS FROM
DEMOLITION PHASE.
(E)
REFLECTIVE CEILING PLAN LEGEND
EXISTING LIGHT
RELOCATED LIGHT
LED EXIT SIGN LITHONIA #EXR LED EL 6,
WITH UNVERSAL MOUNTING, SEALED
MAINTENCE FREE NICKEL CADMIUM
BATTERY, HOUSING COLOR-WHITE,
DIRECTIONAL CHEVRON ARROW WHERE
INDICATED.
DUAL HEAD EMERGENCY BATTERY
BACKUP LITHONIA #EU2 LED M12
ELECTRICAL LIGHTING KEY NOTES
ROOM E149A LIGHTING. ALL LIGHTING TO
REMAIN IN PLACE AND RELOCATED SHALL BE
POWERED FROM PANEL E2/E3 LOCATED IN
ROOM E163.
ROOM E149 LIGHTING. ALL LIGHTING TO BE
RELOCATED SHALL BE POWERED EXISTING
PANEL SOURCE.
E-101
EL
EC
TR
IC
AL
L
IG
H
TI
N
G
PL
AN
1/8" = 1'-0"
1 ELECTRICAL LIGHTING PLAN
E-101
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
El ec tri ca l S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
CALIBRATION SHOP
GRT PACKAGING LAB
PACKAGING LAB
MECHANICAL / ELECTRICAL
ROOM
STORAGE
CORRIDOR
MEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
OFFICES
E145
E146
E162 E163
E166
E167 E168
E144
E155E156
E159
E160
E161
CALIBRATION SHOP
TREASURY
E153 E152
E149
E151
CALIBRATION SHOP
E166
E144
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
3 3 3
2 5
2 5
MECHANCIAL DEMOLISION KEY NOTES
SEE SHEET AD-100 FOR ARCHITECTURAL
ITEMS TO BE DEMOLISHED
SEE SHEET AD-101 FOR REFLECTED CEILING
ITEMS TO BE DEMOLISHED
REMOVE DUCT WORK. CONTRACTOR SHALL
COORDINATE WITH ARCHITECTURAL
DRAWINGS FOR NEW CMU WALL LOCATION
AND CUT DUCT WORK BACK TO NEW
LOCATION. NEW DUCT ENDS SHALL BE
CAPPED WITH SIMILAR METAL MATERIAL AS
EXISTING DUCT AND SEAL FOR NO LEAKS
ROOF PENETRATIONS FOR NEW ROOF TOP
UNIT SHALL BE COORDINATED WITH
CORRUGATED WITH GENERAL CONTRACTOR.
SEE S-100 FOR MORE INFORMATION.
REMOVE EXISTING HVAC SUPPLY AND
RETURN DIFFUSERS. SALVAGE EXISTING
DUCT.
REMOVE EXISTING SLAB MOUNTED CHILLER,
PIPING AND ALL ASSOCIATED COMPONENTS IN
ITS ENTIRETY.
MD-100
M
EC
H
AN
IC
AL
D
EM
O
LI
TI
O
N P
LA
N
1/8" = 1'-0"
1 MECHANICAL DEMOLITION PLAN
MD-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
M ec ha ni ca l S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
CALIBRATION SHOP
GRT PACKAGING LAB
PACKAGING LAB
MECHANICAL / ELECTRICAL
ROOM
STORAGE
CORRIDOR
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
OFFICES
E145
E146
E162 E163
E166
E167 E168
E144
E160
E161
CALIBRATION SHOP
TREASURY
E149
CALIBRATION SHOP
E166
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
24/8
24/14
24/18
30/24
30/24
30/24
30/24
24/8
24/14
24/18
24/8
24/14
24/18
24/18
24/14
24/8 24/8
24/14
24/18 24/18
24/14
24/8
24/8
24/14
24/18
6 6 5
DS
DS
TYPICAL DIFFUSER NOTE:
375 CFM FOR 16 (15-TON RTU
TOTAL CAPACITY IS 6,000 CFM
MECHANCIAL KEY NOTES
46-7/8" / 12-5'8" RETURN DUCT DOWN AND
TRANSITION TO 30/24 DUCT
34" / 26-3/4" SUPPLY DUCT DOWN AND
TRANSITION TO 30/24 DUCT
15-TON RTU ON ROOF. SEE SHEET M101
SEE SHEET A-100 FOR ARCHITECTURAL ITEMS
SEE SHEET A-101 FOR REFLECTED CEILING
ITEMS (TYPICAL FOR LIGHTS)
CONTRACTOR SHALL INSTALL NEW
DEFUSSERS AT THIS LOCATION,
LEGEND:
SUPPLY AIR DIFFUSER.
SIZE: 2'X2'
MANUFACTURE: NAILOR
MODEL: 6500iv
TYPE "L", LAY IN T-BAR FRAME
CAPACITY: 1,000 CFM
NORMINAL NECK SIZE:
21" X 21" / 4-WAY BLOW
RETURN GRILL DIFFUSER.
SIZE: 2'X2'
MANUFACTURE: NAILOR
MODEL: 6500
TYPE "L", LAY IN T-BAR FRAME
CAPACITY: 1,000 CFM
NORMINAL NECK SIZE: 21" X 21"
DUCT SMOKE ALARM -
CONNECT TO FIRE PANEL
DS
MECHANICAL GENERAL NOTES
1 CONTRACTOR IS TO SECURE ALL DUCT WORK,
SUPPLY AND RETURN DEFUSERS AND ALL
ASSOCIATED ITESM TO THE ROOF
STRUCTURE ABOVE THE WORK IN
ACCORDANCE TO ALL FCAA, IMC AND ASHRE
STANDARDS.
M-100
M
EC
H
AN
IC
AL
P
LA
N
1/8" = 1'-0"
1 MECHANICAL PLAN
M-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
M ec ha ni ca l S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
EXISTING
2 3 4 5 6
Q
P
N
M
L
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
M101
NEW
1-1/4" LINE
CONNECT NEW 1-1/4" LINE TO EXISTING
LINE. LENGTH OF NEW RUN FROM POINT OF
CONNECTION TO NEW RTU IS 150' +/-.
CONTRACTOR IS TO VERIFY LENGTH.
PROVIDE PIPE SUPPORT EVERY
10' O.C. DETAIL TBD AT 100% CDS
SEE S-100 FOR
RTU LOCATION
15- TON RTU
46-7/8" / 12-5/8" RETURN
DUCT DOWN AND
TRANSITION TO 30/24 DUCT
34" / 26-3/4" SUPPY DUCT
DOWN AND TRANSITION TO
30/24 DUCT
NEW 1-1/4" GAS LINE.
STEEL PIPE, PAINTED
YELLOW
RTU INFORMATION
MANUFACTURE: CARRIER
MODEL: 48TCEE16H2A-5-WA5JO
48 = GAS HEAT PACKAGE RTU
TC = STANDARD EFFICIENCY
E = MEDIUM HEAT
E = TWO STAGE COOLING
16 = 15 TON
H = RETURN AND SUPPLY AIR SMOKE DETECTORS AND Co2
SENSOR
2 = BELT DRIVE MEDIUM STATIC
A = AL Cu COILS
5 = 208/230 VOLT, 3 PHASE
- = FACTORY DESIGN OPTION
2 = RTU OPEN MULTI-PROTOCOL CONTROLLER
W = ENTHALPY ECONOMIZER WITH BAROMETRIC RELIEF
A = NONE
5 = HINGED DOOR PANEL AND POWERED CONVENIENCE OUTLET
J = 2 SPEED FAN CONTROLLER AND NON-FUSED DISCONNECT
O = STANDARD PACKAGE
MOTOR DISCONNECT/SAFETY SWITCH.
SEE SHEET EP-100
DUPLEX OUTLET.
RTU CURB NOTE:
TBD AT 100% CDS
M-101
M
EC
H
AN
IC
AL
R O
O F
PL
AN
1/8" = 1'-0"
1 MECHANICAL ROOF PLAN
M-101
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
M ec ha ni ca l S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
1/4" = 1'-0"
2 ENLARGED MECHANICAL ROOF PLAN
M-101
MECHANICAL / ELECTRICAL
ROOM
STOR
CO
RR
ID
O
R
TREASURY
STOR
OFFICES
E1
E1
E162 E163
E167 E168
E160
E161
TREASURY
E149
CALIBRATION SHOP
E166
19'-2"±
EXISTING
2 3 4 5 6
Q
P
N
M
L
K
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
MEZZANINE
PLUMBING GENERAL NOTES
1.
2.
3.
PRIOR TO RELOCATING WATER AND WASTE
LINE, CONTRACTOR SHALL COORDINATE WITH
COR AND DPW LOCATION OF LINE
EXTENSIONS.
CONTRACTOR SHALL PROVIDE CLEANOUT IF
ONE DOES NOT CURRENTLY EXIST.
CONTRACTOR SHALL BACKFILL SLAB OPENING
WITH 6" GRAVEL AND THICKNESS OF NEW
CONCRETE SLAB SHALL MATCH EXISTING
ADJACENT SLAB.
PLUMBING KEY NOTES
REMOVE AND RELOCATE EXISTING
SINK/MILLWORK BASE CABINET.
REMOVE CONCRETE SLAB TO ACCOMMODATE
NEW WATER AND WASTE LINE EXTENSIONS
BEYOND THE FACE OF THE NEW CMU WALL.
REPLACE EXISTING HOT AND COLD WATER
VALVES WITH NEW VALVES.
P-100
PL
U
M
BI
N G
P
LA
N
1/8" = 1'-0"
1 PLUMBING PLAN
P-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Pl um bi ng
S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
PACKAGING LAB
MECHANICAL / ELECTRICAL
ROOM
STORAGE
CORRIDOR
MEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
E145
E146
E162 E163
E167 E168
E144
E155E156
E158
E159
TREASURY
E153 E152
E149
E151
CALIBRATION SHOP
E166
E1
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
J
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
5 5 5 5
8 9 9
7A
11 11
17A 17A
16A
16B
EXISTING EQUIPMENT / FURNITURE LIST
7A
16A
16B
17A
STAND UP STAPLE MACHINE
SCALE
36 X 84 TABLE
42 X 54 FLAT FILES (2 STACKED)
24 X 84 FIVE SHELF STORAGE RACK
PACKAGING MANUFACTURING MACHINE
PACKAGING CUTTING MACHINE
28 X 82 WOOD BOX
PORTABLE GENERATOR
18 X 36 HIGH STORAGE CABINET
18 X 42 FLAMMABLE STORAGE CABINET
42 X 126 THREE SHELF PALLET RACK. MOVE TO
ROOM E149A
30 X 43 HIGH STORAGE CABINET
18 X 36 HIGH STORAGE CABINET
48 X 48 SHAKE TABLE
36 X 66 VERTICAL PRESS MACHINE
60 X 66 PRESS MACHINE
30 X 72 TABLE
36 X 72 TABLE
74 X 112 CUTTING MACHINE
LARGE BUBBLE WRAP ROLL DISPENSER
15 X 30 HIGH STORAGE CABINET
30 X 212 STORAGE DRAWERS WITH COUNTER TOP
24 X 36 HIGH STORAGE CABINET
18 X 36 HIGH STORAGE CABINET
18 X 42 HIGH STORAGE CABINET
28 X 28 WOOD TABLE
96 X 480 PARACHUTE ASSEMBLY TABLE
34 X 72 SEWING MACHINE TABLE
72 X 480 PARACHUTE ASSEMBLY TABLE.
81 X 84 SEWING MACHINE TABLE
300 X 396 RUBBER MAT. 18 X 18 INTERLOCKING
SQUARES EACH
EXISTING CUBICLES, CHAIRS AND FILE CABINETS
TO BE DISPOSED. SEE SHEET AD-100 DEMOLITION
EQ-100
EX
IS
TI
N
G E
Q U
IP
M
EN
T
PL
AN
1/8" = 1'-0"
1 EXISTING EQUIPMENT PLAN
EQ-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Eq ui pm en t S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
EXISTING
2 3 4 5 6 7
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
CALIBRATION SHOP
MECHANICAL
STORAGE
CO
RR
ID
O
R
TREASURY
STORAGE
E145
E146
E162 E163
E167 E168
E155E156
E158
E159
TREASURY
E153 E152 E151
CALIBRATION SHOP
E166
Q
P
N
M
L
K
J
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
MEZZANINE
715 sqft +/-
2212 sqft +/-
ELECTRICAL
ROOM
17A17A
16A
16B
1 12
5 5 5 5
109 9 9
11 11 11
7A
FLOOR MOUNTED ELEC
TRANSFORMERS
EXISTING
POWER
FOR
ITEM 14
EXISTING
POWER
FOR
ITEM 15
EXISTING
POWER
FOR
ITEM 16
EXISTING
POWER
FOR
ITEM 17
RELOCATED
POWER
FOR
ITEM 14
RELOCATED
POWER
FOR
ITEM 16
RELOCATED
POWER
FOR
ITEM 15
RELOCATED
POWER
FOR
ITEM 17
PACKAGING LAB
E149
EQUIPMENT / FURNITURE LIST
7A
16A
16B
17A
STAND UP STAPLE MACHINE
SCALE
36 X 84 TABLE
42 X 54 FLAT FILES (2 STACKED)
24 X 84 FIVE SHELF STORAGE RACK
PACKAGING MANUFACTURING MACHINE
PACKAGING CUTTING MACHINE
28 X 82 WOOD BOX
PORTABLE GENERATOR
18 X 36 HIGH STORAGE CABINET
18 X 42 FLAMMABLE STORAGE CABINET
42 X 126 THREE SHELF PALLET RACK. MOVE TO
ROOM E149A
NOT IN CONTRACT, MOVED BY AGENCY
NOT IN CONTRACT, MOVED BY AGENCY
48 X 48 SHAKE TABLE. EXISTING POWER TO BE
RELOCATED TO NEW LOCATION
36 X 66 VERTICAL PRESS MACHINE. EXISTING
POWER TO BE RELOCATED TO NEW LOCATION
60 X 66 PRESS MACHINE. POWER TO BE
RELOCATED TO NEW LOCATION
30 X 72 TABLE
36 X 72 TABLE
74 X 112 CUTTING MACHINE.
LARGE BUBBLE WRAP ROLL DISPENSER
15 X 30 HIGH STORAGE CABINET
NOT IN CONTRACT, MOVED BY AGENCY
NOT IN CONTRACT, MOVED BY AGENCY
NOT IN CONTRACT, MOVED BY AGENCY
NOT IN CONTRACT, MOVED BY AGENCY
NOT IN CONTRACT, MOVED BY AGENCY
NOT IN CONTRACT, MOVED BY AGENCY
NOT IN CONTRACT, MOVED BY AGENCY
NOT IN CONTRACT, MOVED BY AGENCY
NOT IN CONTRACT, MOVED BY AGENCY
NOT IN CONTRACT, MOVED BY AGENCY
EQ-101
EQ
U
IP
M
EN
T
R
EL
O C
AT
IO
N P
LA
N
1/8" = 1'-0"
1 EQUIPMENT RELOCATION PLAN
EQ-101
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Eq ui pm en t S er ie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
MECHANICAL
TREASURY
E149A
MEZZANINE
715 sqft +/-
2212 sqft +/-
ELECTRICAL
ROOM
AIR
PR100
E-A N-A2
E-V E-V N-V
NEW VACUUM PIPE TO BE
LOCATED AT THE TOPSIDE OF
LOWER CHORD OF THE
EXISTING ROOF TRUSS
1.
2.
3.
CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING AND CONFIRMING LOCATIONS
AND MOUNTING HEIGHTS OF ALL RELOCATED
WATER VACCUUM, GAS AND NEW AIR LINES
WITH ARCHITECT. HEAD CLEARANCE SHALL BE
7'-0" MIN
ALL NEW LINES, FITTING, ETC MUST COMPLY
WITH ALL UFC, AND APPLICABLE BUILDING
CODES AND OTHER INDUSTRY STANDARDS
AND REGULATIONS.
CONTRACTOR SHALL VERIFY ALL EXISTING
PIPE SIZES TO PROVIDE ACCURATE
CONNECTIONS TO NEW PIPE, NEW PIPES
SHALL BE THE SAME SIZE AS EXISTING PIPE
WHICH THAT ARE CONNECTING.
AIR AND WATER LEGEND
EXISTING COMPRESSED
AIR LINE
NEW COMPRESSED AIR
LINE
EXISTING VACUUM LINE
NEW VACUUM LINE
EXISTING DOMESTIC HOT
WATER
NEW DOMESTIC HOT WATER
EXISTING CONDENSER
WATER SUPPLY OR RETURN
NEW CONDENSER WATER
SUPPLY AND RETURN
EXISTING GAS LINE
NEW GAS LINE
EXISTING COPPER LINE
NEW COPPER LINE
AIR AND WATER KEY NOTES
EXISTING AIR COMPRESSOR.
EXISTING FLOOR MOUNTED MECHANICAL UNIT
E-A
N-A
E-DHW
E-CW-TYPE
N-DHW
N-CW-TYPE
E-V
N-V
E-G
N-G
E-CP
N-CP
MECHANICAL
CO
RR
ID
O
R
TREASURY
E149A
MEZZANINE
715 sqft +/-
2212 sqft +/-
ELECTRICAL
ROOM
E-DHW
PR100
E-WATER
E-CP
N-DHW
NEW PIPE TO BE LOCATED
TIGHT TO THE UNDERSIDE OF
LOWER CHORD OF THE
EXISTING ROOF TRUSS
N-CP
NEW COPPER PIPE TO BE
LOCATED AT THE TOPSIDE OF
LOWER CHORD OF THE
EXISTING ROOF TRUSS
PR-100
AI
R
D
O M
H O
T W
AT
ER
R
EL
O C
AT
IO
N P
LA
N
3/16" = 1'-0"
1 COMPRESSED AIR PLAN
PR-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Pr oc es s
Se rie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
3/16" = 1'-0"
1 DOMESTIC AND PROCESS WATER PLAN
PR-100
N.T.S.
3 EXISTING PIPE PHOTOGRAPH
PR-100
D
EXISTING COMPRESSED
AIR LINE
N.T.S.
PR-100
EXISTING DOMESTIC HOT
WATER LINE TO BE RELOCTED
EXISTING STEEL FRAME TO
BE REMOVED, SEE AD-100
EXISTING CONDENSER LINE
TO BE RELOCATED SEE PR-101
NEW COMPRESSED AIR LINE
TO GFGI EQUIPMENT
EXISTING WATER LINE TO REMAIN
N.T.S.
PR-100
EXISTING DOMESTIC HOT
WATER LINE TO BE RELOCTED
EXISTING STEEL FRAME TO
BE REMOVED, SEE AD-100
EXISTING CONDENSER LINE
TO BE RELOCATED SEE PR-101
EXISTING WATER LINE TO REMAIN
EXISTING VACUUM LINE
EXISTING GAS LINE
EXISTING VACUUM, GAS AND COPPER
LINES TO BE RELOCATED. ABOVE
LOWER TRUSS CORD
EXISTING PIPE PHOTOGRAPH
EXISTING PIPE PHOTOGRAPH
EXISTING VACUUM LINE TO BE
RELOCATED
EXISTING GAS LINE TO BE
RELOCATED. SEE PR-101
EXISTING COPPER LINE TO BE
RELOCATED
MECHANICAL
CO
RR
ID
O
R
TREASURY
E149A
MEZZANINE
715 sqft +/-
2212 sqft +/-
ELECTRICAL
ROOM
PR100
3 MECH
M
AI
N C
W R
ET
U
R N
M
AI
N C
W S
U
PP
LY
CW RETURN
CW SUPPY
C W
S U
PP
LY
C W
R
ET
U R
N
N-CW
NEW PIPE TO ALIGN WITH
EXISTING PRIOR TO 90 BEND
DOWN. NEW PIPE TO FLOW
PATH OF EXISTING, BUT 90
BEND DOWN IN ROOM E166
E-G
E-G
N-G
NEW GAS PIPE TO BE
LOCATED AT THE TOPSIDE OF
LOWER CHORD OF THE
EXISTING ROOF TRUSS
1.
2.
3.
CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING AND CONFIRMING LOCATIONS
AND MOUNTING HEIGHTS OF ALL RELOCATED
WATER VACCUUM, GAS AND NEW AIR LINES
WITH ARCHITECT. HEAD CLEARANCE SHALL BE
7'-0" MIN
ALL NEW LINES, FITTING, ETC MUST COMPLY
WITH ALL UFC, AND APPLICABLE BUILDING
CODES AND OTHER INDUSTRY STANDARDS
AND REGULATIONS.
CONTRACTOR SHALL VERIFY ALL EXISTING
PIPE SIZES TO PROVIDE ACCURATE
CONNECTIONS TO NEW PIPE, NEW PIPES
SHALL BE THE SAME SIZE AS EXISTING PIPE
WHICH THAT ARE CONNECTING.
AIR AND WATER LEGEND
EXISTING COMPRESSED
AIR LINE
NEW COMPRESSED AIR
LINE
EXISTING VACUUM LINE
NEW VACUUM LINE
EXISTING DOMESTIC HOT
WATER
NEW DOMESTIC HOT WATER
EXISTING CONDENSER
WATER SUPPLY OR RETURN
NEW CONDENSER WATER
SUPPLY AND RETURN
EXISTING GAS LINE
NEW GAS LINE
EXISTING COPPER LINE
NEW COPPER LINE
AIR AND WATER KEY NOTES
EXISTING AIR COMPRESSOR.
EXISTING FLOOR MOUNTED MECHANICAL UNIT
E-A
N-A
E-DHW
E-CW-TYPE
N-DHW
N-CW-TYPE
E-V
N-V
E-G
N-G
E-CP
N-CP
PR-101
C O
N D
EN
SE
R W
AT
ER
G
AS
R
EL
O
C
AT
IO
N
P
LA
N
3/16" = 1'-0"
1 CONDENSER WATER AND GAS LINE PLAN
PR-101
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Pr oc es s
Se rie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
D
MECHANICAL / ELECTRICAL
ROOM
STO
CO
RR
ID
O
R
TREASURY
STO
E1
E1
E162 E163
E166
E167 E168
CALIBRATION SHOP
TREASURY
E149
CALIBRATION SHOP
E166
19'-2"±
EXISTING
2 3 4 5 6
Q
P
N
M
L
K
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
MEZZANINE
(E)
FA
FAP
SD
FA
SD SD
FA FA
FA
(E)
FA
(E)
FAP
(E)
FA
(E)
FA
FAP
FIRE ALARM PLAN LEGEND
FIRE ALARM SYSTEM SPEAKER
AND STROBE WITH SINGLE
CLEAR VISUAL INDICATOR
DEVICE MARKED "ALERT". RED
HOUSING, WALL MOUNTED AT
7'-6" AFF. CANDELA RATING NO
LESS THAN 15 CD. (E) INDICATES
EXISTING.
FIRE ALARM MANUAL DOUBLE
ACTION PULL STATION. RED
HOUSING, WALL MOUNTED AT
4'-0" AFF TO TOP OF PULL ARM.
(E) INDICATES EXISTING.
PHOTOELECTRIC SMOKE
DETECTOR. MOUNTED ON POLE
TO REACH 15'-0" AFF
FIRE ALARM GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
ALL FIRE ALARM WIRING SHALL BE INSTALLED
IN RED CONDUIT.
SEAL ALL PENETRATIONS THROUGH WALLS.
PROVIDE FA MODULES AND CONNECTIONS TO
ALL DEVICES (DUCT SMOKE DETECTORS).
PROVIDE REQUIRED PROGRAMING TO
INCORPORATE SIGNALS FOR ALL DEVICES,
EVEN IF DEVICE IS UNDER DIFFERENCE
SECTION OF WORK.
MOUNTING HEIGHTS ARE MEASURED FROM
CENTER POINT OF DEVICE U.N.O.
CONNECT NEW DEVICES TO FIRE ALARM
PANEL LOCATED AT BUILDING 36 ENTRY
LOBBY.
ALL DEVICES ARE CONCIDERED NEW UNLESS
NOTED WITH (E) FOR EXISTING.
FA
FAP
SD
FA-100
FI
R
E
AL
AR
M
P
LA
N
1/8" = 1'-0"
1 FIRE ALARM PLAN
FP-100
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Ba se
_F ire
A la rm P la ns
.d w g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
PACKAGING LAB
MECHANICAL
STORAGE
CORRIDOR
MEN
CORRIDOR
CO
RR
ID
O
R
TREASURY
STORAGE
E145
E146
E162 E163
E167 E168
E144
E155E156
E159
TREASURY
E153 E152
E149
E151
CALIBRATION SHOP
E166
E144
19'-2"±
EXISTING
2 3 4 5 6 7
Q
P
N
M
L
K
J
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
MEZZANINE
715 sqft +/-
2212 sqft +/-
ELECTRICAL
ROOM
UP
ACSACS IDS
IDS
IDS
IDS
SECURITY PLAN KEY NOTES
1 EXISTING SECURITY PANEL. ALL NEW
SECURITY EQUIPMENT SHALL BE WIRED TO
THIS LOCATION
ACS
SECURITY PLAN LEGEND
CAMERA
SYSTEM: AVIGILON CAMERAS AND SOFTWARE
CONTRACTOR: METRO SURVEILLANCE
TEL: 401-228-8550
ACCESS CONTROL
SYSTEM: INFINIAS
CONTRACTOR: METRO SURVEILLANCE
TEL: 401-228-8550
INTRUSION DETECTION
SYSTEM: ICIDS V
CONTRACTOR: OSG SECURITY
POC: CHRIS EASLEY
TEL: 253-212-2659
IDS
SECURITY GENERAL NOTES
1.
2.
3.
THIS PLAN IS DIAGRAMATICAL TO ILLUSTRATE
LOCATIONS OF REQUIRED CAMERAS,
INTRUSION DETECTION AND ACCESS
CONTROL EQUIPMENT AND LOCATION OF
EXISTING SECURITY PANEL BOARD.
ALL WIRE HOME RUNS SHALL BE INSTALLED
PER UFC.
CONTRACTOR SHALL PROVIDE PLANS AND
EQUIPMENT SUBMITTALS FOR APPROVAL BY
NATICK SYSTEM SOLDIER CENTER SECURITY
OFFICE PRIOR TO INSTALLATION.
ES-100
SE
C
U R
IT
Y
PL
AN
1/8" = 1'-0"
1 SECURITY PLAN
ES-101
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D W
D W
AS
N
O
TE
D
Se cu rit y
Se rie s.
dw g
BU
IL
D
IN
G
BE
P R
EN
O
VA
TI
O N
S N
AT
IC
K
SY
ST
EM
S O
LD
IE
R C
EN
TE
R N
AT
IC
K, M
AS
SA
C H
U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
EV
C O
M S
O
LI
D
ER
S C
EN
TE
R G
EN
ER
A L
G R
EE
N
E A
VE
N
U E
N A
TI
C
K , M
A
TB
D
D W
TB
D
TB
D
D
ES
IG
N D
EV
EL
O
PM
EN
T
A
PR
0% C
O R
R
EC
TE
D
F
IN
AL
J
U
LY
MECHANICAL / ELECTRICAL
ROOM
STOR
CO
RR
ID
O
R
TREASURY
STOR
OFFICES
E1
E1
E162 E163
E166
E167 E168
E160
E161
CALIBRATION SHOP
TREASURY
E149
CALIBRATION SHOP
E166
19'-2"±
EXISTING
2 3 4 5 6
Q
P
N
M
L
K
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
20'-0"±
EXISTING
'-2
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-0
EX
IS
TI
NG
TREASURY
E149A
MEZZANINE
AT
FLOOR
TELECOMMUNICATIONS GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
THIS PLAN IS DIAGRAMATICAL TO ILLUSTRATE
LOCATIONS OF REQUIRED DATA OUTLETS.
ALL WIRE HOME RUNS SHALL BE INSTALLED
PER UFC.
CONTRACTOR SHALL PROVIDE PLANS AND
EQUIPMENT SUBMITTALS FOR APPROVAL BY
NATICK SYSTEM SOLDIER CENTER NEC PRIOR
TO INSTALLATION.
TELECOMMUNICATIONS WIRING SHALL BE
INSTALLED IN CONDUIT.
WIRING SHALL IN INSTALLED FROM THE
DEVICE AND TERMINATE AT THE PANEL
BOARD.
INSTALL CAT 6 COPPER WIRE; WIRE:
CMP-00424 MWK*6U*01 MOHAWK WIR M582808
23-4P UTP-CMP SOL BC CAT6. FEP/PRBVC
WHITE JACKET 6 LAN BOX.
ALL DEVICES ARE SHOWN AS NEW, UNLESS
NOTED OTHERWISE.
TELECOMMUNICATIONS LEGEND
ORTRONICS MODULAR JACK, 2-PORT, CAT 6,
T568A/B WIRING. 48.26 MM X 30.48 MM X 23.37
MM, HIGH IMPACT THERMOPLASTIC, FOG
WHITE. MFR PART NO. S22600
ORTRONICS SERIES II FACEPLATE (SINGLE
GANG), FOG WHITE. MFR PART NO. 40300011
TELECOMMUNICATIONS KEY NOTES
EXISTING TEL/DATA OUTLETS AND CONDUIT
SHALL BE REMOVED FROM EXISTING WALL
PRIOR TO DEMOLITION AND REINSTALLED ON
NEW CMU WALL IN ROOM E166.
RELOCATE ALL WALL MOUNTED TELECOM
DEVICES AND WIRING ON NEW CMU WALL IN
ROO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .