About this file
This document is a Salient Characteristics file for a Department of the Army contract (Solicitation Number W911QX25QA034) seeking a specialized laser cleaning system. The procurement requires one 1000-Watt high-power, pulsed, solid-state laser system for ablative laser cleaning, with comprehensive specifications including a CL1000 laser system, hand-held optical system, mobile housing, 20-meter fiber optic cable, laser fume extractor, digital controls, and safety equipment. Key technical requirements include operating on a 480-volt, 3-phase, 20-amp power connection, capability to remove 3-4 mil chemical agent resistant coatings in a single pass, and compliance with Air Force Technical Manual TO 36-1-191.
The system must meet specific performance standards, such as clearing a 4x6 inch area in under 30 seconds and removing coating at rates exceeding two square feet per minute per mil of coating. Additional procurement requirements include four laser safety curtains, one set of five laser safety glasses, and four days of onsite installation. The solicitation is issued by the Army Contracting Command at Aberdeen Proving Ground, with the document last updated on 07/28/2016 and revised on 8 September 2025. A commercial availability certification is included, indicating that all specified characteristics are available in the commercial marketplace.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Combination Synopsis-Solicitation for Commercial Purchases_W911QX25QA034 - Amendment 0001.docx | DOCX document | |
| Provisions and Clauses Full-Text Attachment (for Combo Synopsis-Solicitation) - W911QX25QA034.docx | DOCX document | |
| Combination Synopsis-Solicitation for Commercial Purchases_W911QX25QA034.docx | DOCX document | |
| Salient Characteristics - W911QX25QA034.doc | DOC document | |
| Evaluation Criteria (Comparative).docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics Revised 8 September 2025
Commercial Availability Certification:
I have evaluated the commercial marketplace and determined that all of the salient characteristics documented below are available in products/services offered in the commercial marketplace.
Signature (typed name): TBA After Contract Award (ACA)_________
Technical Point of Contact (TPOC) or Contracting Officer’s Representative (COR)
The Contractor shall provide One (1) 1000 Watt (W) High power, pulsed, solid state laser system for ablative laser cleaning with following minimum salient characteristics:
· One (1) CL1000 - 1000W High power, pulsed, solid state laser system for ablative laser cleaning that operates on a 480 volt (V), 3-phase, 20 amperage (amp) power connection
· One (1) 1D-Optical system OSH50 - Hand-held, manually controlled, low-weight, pistol-grip laser with up to 80 millimeters (mm) beam deflection and integrated point-source suction channel
· One (1) Mobil-Housing – Welded steel frame housing for all components of laser system on rolling wheel with water/air cooling
· One (1) 20 meters (m) optic fiber system for mid-power laser systems - Heavy duty fiber optic cable
· One (1) Quick Connect Fiber Coupler (QCF) – for connecting the fiber optic cable to the housing
· Internal vacuum to remove vapor at point of generation
· One (1) Laser Fume Extractor (LFE) 401 - Laser fume extractor filter with High Efficiency Particle Air (HEPA) or Ultra Low Penetration Air (ULPA) filters and dust collection bin.
· One (1) CleanTOUCH - Digital controls to adjust laser beam parameters with data logging and error reporting with status indicator lamp for safety
Additional Requirements:
· Four (4) 5M FLEX-GUARD - Laser curtains for safety; minimum 6 feet (‘) X 6 feet (‘) for each
· REMOVED
· One (1) set of five (5) Laser safety glasses
· Four (4) days of onsite installation required
· The system shall be compliant with demonstrations and validations as described in Air Force Technical Manual Technical Order (TO) 36-1-191, 6.14.10.3
· The system shall be capable of removing 3-4mil (0.003-0.004 inches) of Chemical Agent Resistant Coatings to a Society for Protective Coatings - Surface Preparation (SSPC-SP) 10/ National Association of Corrosion Engineers (NACE) Number (No). Two (2) equivalent level of clean in a single pass and fully clearing a 4 x 6 inch area in under 30 seconds or meet coating removal rates exceeding two (2) Square (sq) Feet (ft) per minute per mil of coating Contracting Officer:
Template last updated 07/28/2016