Salient Characteristics - W911QX25QA034.doc
DOC document 80 KB Posted
- Attached to
- Amendment 0001** One (1) 1000 Watt (W) High power, pulsed, solid state laser system for ablative laser cleaning with additional specifications Federal contract opportunity
- Solicitation number
- W911QX25QA034
About this file
The document is a Salient Characteristics file for a federal contract solicitation (W911QX25QA034) issued by the Department of the Army Materiel Command Army Contacting Command at Aberdeen Proving Ground. The solicitation requires the procurement of a comprehensive 1000-Watt high-power, pulsed, solid-state laser system for ablative laser cleaning, with specific technical requirements including a CL1000 laser system, hand-held optical system, mobile housing, fiber optic components, and integrated safety features.
The laser system must operate on a 480-volt, 3-phase, 20-amp power connection and demonstrate advanced capabilities, including removing 3-4 mil chemical agent-resistive coatings in a single pass, clearing a 4x6 inch area in under 30 seconds, and meeting SSPC-SP 10/NACE No. 2 cleaning standards. Additional requirements include four laser safety curtains, a portable fume extractor, five sets of laser safety glasses, and four days of onsite installation. The system must also comply with Air Force Technical Manual Technical Order 36-1-191 specifications for demonstration and validation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Salient Characteristics - W911QX25QA034 - Revised.doc | DOC document | |
| Combination Synopsis-Solicitation for Commercial Purchases_W911QX25QA034 - Amendment 0001.docx | DOCX document | |
| Provisions and Clauses Full-Text Attachment (for Combo Synopsis-Solicitation) - W911QX25QA034.docx | DOCX document | |
| Combination Synopsis-Solicitation for Commercial Purchases_W911QX25QA034.docx | DOCX document | |
| Evaluation Criteria (Comparative).docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics Commercial Availability Certification:
I have evaluated the commercial marketplace and determined that all of the salient characteristics documented below are available in products/services offered in the commercial marketplace.
Signature (typed name): TBA After Contract Award (ACA)_________
Technical Point of Contact (TPOC) or Contracting Officer’s Representative (COR)
The Contractor shall provide One (1) 1000 Watt (W) High power, pulsed, solid state laser system for ablative laser cleaning with following minimum salient characteristics:
· One (1) CL1000 - 1000W High power, pulsed, solid state laser system for ablative laser cleaning that operates on a 480 volt (V), 3-phase, 20 amperage (amp) power connection
· One (1) 1D-Optical system OSH50 - Hand-held, manually controlled, low-weight, pistol-grip laser with up to 80 millimeters (mm) beam deflection and integrated point-source suction channel
· One (1) Mobil-Housing – Welded steel frame housing for all components of laser system on rolling wheel with water/air cooling
· One (1) 20 meters (m) optic fiber system for mid-power laser systems - Heavy duty fiber optic cable
· One (1) Quick Connect Fiber Coupler (QCF) – for connecting the fiber optic cable to the housing
· Internal vacuum to remove vapor at point of generation
· One (1) Laser Fume Extractor (LFE) 401 - Laser fume extractor filter with High Efficiency Particle Air (HEPA) or Ultra Low Penetration Air (ULPA) filters and dust collection bin.
· One (1) CleanTOUCH - Digital controls to adjust laser beam parameters with data logging and error reporting with status indicator lamp for safety
Additional Requirements:
· Four (4) 5M FLEX-GUARD - Laser curtains for safety; minimum 6 feet (‘) X 6 feet (‘) for each
· One (1) Teka 501 portable fume and particle extractor with spark arrestor
· One (1) set of five (5) Laser safety glasses
· Four (4) days of onsite installation required
· The system shall be compliant with demonstrations and validations as described in Air Force Technical Manual Technical Order (TO) 36-1-191, 6.14.10.3
· The system shall be capable of removing 3-4mil (0.003-0.004 inches) of Chemical Agent Resistant Coatings to a Society for Protective Coatings - Surface Preparation (SSPC-SP) 10/ National Association of Corrosion Engineers (NACE) Number (No). Two (2) equivalent level of clean in a single pass and fully clearing a 4 x 6 inch area in under 30 seconds or meet coating removal rates exceeding two (2) Square (sq) Feet (ft) per minute per mil of coating Contracting Officer:
Template last updated 07/28/2016
File details come from the government source that posted it. Updated .