Amendment_08.pdf

PDF 12 MB Posted

Attached to
CLR043 Design and Construct Fire Station Federal contract opportunity
Solicitation number
W911KB-17-R-0021
Issued by
Department of the Army Corps of Engineers Engineering District Alaska

About this file

CLR043 - Amendment 08

View the file

Other files for this federal contract opportunity

Other files attached to CLR043 Design and Construct Fire Station, newest first.
File Type Posted
AM_10.pdf PDF
A.3.9_Redacted_JA_CLR043_Fire_Station_Siemens_BCAS.pdf PDF
W911KB-17-R-0021_AM_09.pdf PDF
CLR043_SF30_Amendment_07.pdf PDF
W911KB-17-R-0021_AM_05.pdf PDF
W911KB-17-R-0021-0006.pdf PDF
SF30_AM04.pdf PDF
Amendment_3_to_post.pdf PDF
CLR043_SF30_AM_02-finala.pdf PDF
W911KB-17-R-0021_AM_01.pdf PDF
W911KB-17-R-0021_Solicitation.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLR043

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

PROJECT TITLE/LOCATION: CLR043, FIRE STATION, CLEAR AFS, ALASKA

a. This amendment provides changes to the solicitation as indicated on the continuation pages of this document.

b. PROPOSAL DUE DATE IS: 15 June 2017 at 1400 hours ALASKA TIME. Proposals shall be submitted in accordance w ith Section 00 21 00, paragraph 1.10, Proposal Submittals.

c. YOU ARE REQUIRED TO ACKNOWLEDGE RECEIPT OF THIS AMENDMENT ON THE REVERSE SIDE OF THE STANDARD FORM 1442.

1. CONTRACT ID CODE PAGE OF PAGES

J 1

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 25-May-2017

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W911KB-17-R-0021

X 9B. DATED (SEE ITEM 11)

22-Dec-2016

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

26-May-2017

CODE

U.S. ARMY ENGINEER DISTRICT, AK

CEPOA-CT (W911KB)

PO BOX 6898

JBER AK 99506-0898

W911KB 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

a. The following drawings are substituted for the superseded documents/sections:

b. The following revised documents/sections are substituted for the superseded documents/sections. The identifier “AM08” appears before and after new and/or revised materials, except as noted below.

SECTION 01 11 00– STANDARD FORM (SF) 1442, BLOCK 13-A

Extended proposal due date to 15 June 2017 at 2:00PM Alaska Time

SECTION 00 22 20 – PHASE 2 DESIGN-BUILD SELECTION PROCEDURES AND BASIS

OF AWARD

- 5.3.1 -

SECTION 00 73 46 - Wage Rates

- Replace with AK170001 05/19/2017 AK1

SECTION 01 10 00 – STATEMENT OF WORK

- 2.3.9 F – Air Barrier

- 2.5.2 A f –Ventilation air

- 2.5.2 C a – Steam Boiler

- 2.8 – Hazardous Materials

APPENDIX B

- Room Criteria Sheets

NOTE: Revisions within the following documents do not contain the above referenced identifiers:

c. The following sections are deleted:

NONE

d. The following documents are added:

Image(s) 0632, 0633, 0634, 0635, 0636, 0637, and 0638; Figure 1.1 Character Areas – Facilities Excellence Plan;

e. The following revisions are incorporated:

f. Other:

G-1 SHT 002-002, G-2 SHT 001-001, G-3 SHT 001-001, G-4 SHT 001-001, G-5 SHT 002-002, and G-8 SHT 001-001 via AMERDEC; CLR043 C-101 via AMERDEC

(End of Summary of Changes)

ALL OTHER TERMS AND CONDITIONS SHALL REMAIN THE SAME.

NONE

Section 00 22 20 Page 7

• Are the proposed colors and material finishes conducive to the working environment of the facility?

• Has the proposal addressed/provided for natural and artificial light in working spaces and is the arrangement of fenestration and lighting fixtures in the spaces conducive to space usage?

• Has “support item” placement been considered and addressed in the proposal to enhance the environment? For example: placement of supply/exhaust devices, placement of electrical panels, and placement of exhaust fans, etc.

• Does the proposal provide for acoustic control of noise in the fire station?

5.2.2.3. Minimum Space and Facility Size: The proposal must include all the mandatory spaces in response to the requirements set forth in Section 01 10 00, Statement of Work. For this element, proposals will be evaluated on compliance with these requirements. Individual areas may slightly exceed the requirements, so long as building function is not compromised elsewhere and as long as the overall square footage is not greater than that as described in

Section 01 10 00, as authorized by Congress

5.3. VOLUME 1- TAB B – SUBFACTOR 2 - QUALITY OF BUILDING SYSTEMS AND MATERIALS

5.3.1. General. As part of this Subfactor, the Government has identified certain items as desirable features or preferable items. Desirable features are identified below in the evaluation criteria. Preferable items are listed in order of priority. These items, along with any Offeror-identified betterment, will be given additional consideration during the evaluation process, provided that they are included in the proposed base price and are within the contract cost limitation

(CCL) identified in the Solicitation.

Preferable Items:

1. Day lighting via insulated translucent wall systems located on all four sides of apparatus bay. System shall consist of translucent wall panels with minimum light transmission of 17% and U-factor of 0.05 thermally broken.

2. Sound absorption panels/baffles in ceiling and/or on walls to reduce noise in the apparatus bay. Baffle face area will ideally total at least half of the total combined wall and ceiling area of the apparatus (less doors). Sound baffle core should be inert, mildew resistance and meet fire rating ASTM E- 84 class I.

Baffles will ideally have noise reduction capability of 25 STC or 0.80 NRC, minimum.

3. Laminate solar panels mounted to vertical building surfaces.

5.3.2. Submission Requirements:

5.3.2.1. Presentation Drawings

There are no specific drawings requirements for this Subfactor. However, the Offeror has the option of providing concept level drawing information for specific materials and/or systems which the Offeror feels are necessary to describe the proposed systems or materials in the drawings provided under Tab A.

5.3.2.2. Technical Approach Narrative:

Provide technical approach narrative, both qualitative and quantitative, defining the elements of the proposal. It is the responsibility of the proposer to ensure that all aspects identified in the evaluation criteria below are addressed.

Maximum total length for the narrative shall be ten (10) typewritten pages.

(a) Architectural Finishes: Describe how the materials selected provide for a suitable environment for the

AM 08... AM 08...

J4RMMJCM

Cross-Out

General Decision Number: AK170001 05/26/2017 AK1

Superseded General Decision Number: AK20160001

State: Alaska

Construction Types: Building and Heavy

Counties: Alaska Statewide.

BUILDING AND HEAVY CONSTRUCTION PROJECTS (does not include residential construction consisting of single family homes and apartments up to and including 4 stories)

Note: Under Executive Order (EO) 13658, an hourly minimum wage of $10.20 for calendar year 2017 applies to all contracts subject to the Davis-Bacon Act for which the contract is awarded (and any solicitation was issued) on or after January 1, 2015. If this contract is covered by the EO, the contractor must pay all workers in any classification listed on this wage determination at least $10.20 (or the applicable wage rate listed on this wage determination, if it is higher) for all hours spent performing on the contract in calendar year 2017.

The EO minimum wage rate will be adjusted annually. Additional information on contractor requirements and worker protections under the EO is available at www.dol.gov/whd/govcontracts.

Modification Number Publication Date 0 01/06/2017 1 01/20/2017 2 01/27/2017 3 02/17/2017 4 03/17/2017 5 03/31/2017 6 04/07/2017 7 04/21/2017 8 05/12/2017 9 05/19/2017 10 05/26/2017

ASBE0097-001 01/01/2017

Rates Fringes

Asbestos Workers/Insulator (includes application of all insulating materials protective coverings, coatings and finishings to all types of mechanical systems).........................$ 38.68 20.07

HAZARDOUS MATERIAL HANDLER

(includes preparation, wetting, stripping, removal scrapping, vacuming, bagging, and disposing of all

AM 08...

insulation materials, whether they contain asbestos or not, from mechanical systems).........$ 37.38 19.55

BOIL0502-002 08/01/2016

Rates Fringes

BOILERMAKER......................$ 44.26 28.41

BRAK0001-002 07/01/2016

Rates Fringes

Bricklayer, Blocklayer, Stonemason, Marble Mason, Tile Setter, Terrazzo Worker.....$ 40.81 19.15 Tile & Terrazzo Finisher.........$ 34.79 19.15

CARP1501-001 09/01/2014

Rates Fringes

MILLWRIGHT.......................$ 35.74 21.29

* CARP2520-003 09/01/2016

Rates Fringes

Diver Stand-by....................$ 42.65 25.04 Tender......................$ 41.65 25.04 Working.....................$ 82.45 25.04 Piledriver Carpenter...................$ 38.34 25.04 Piledriver; Skiff Operator and Rigger..................$ 38.34 25.04 Sheet Stabber...............$ 38.34 25.04 Welder......................$ 43.90 25.04

DEPTH PAY PREMIUM FOR DIVERS BELOW WATER SURFACE:

50-100 feet $1.00 per foot 101 feet and deeper $2.00 per foot

ENCLOSURE PAY PREMIUM WITH NO VERTICAL ASCENT:

5-50 FEET $1.00 PER FOOT/DAY

51-100 FEET $2.00 PER FOOT/DAY

101 FEET AND ABOVE $3.00 PER FOOT/DAY

SATURATION DIVING:

The standby rate applies until saturation starts. The saturation diving rate applies when divers are under pressure continuously until work task and decompression are complete. the diver rate shall be paid for all saturation hours.

WORK IN COMBINATION OF CLASSIFICATIONS:

Employees working in any combination of classifications within the diving crew (except dive supervisor) in a shift are paid in the classification with the highest rate for that shift.

CARP4059-001 09/01/2014

Rates Fringes

CARPENTER

Carpenter...................$ 37.34 23.34 Lather/Drywall Applicator...$ 36.59 22.59

ELEC1547-004 04/01/2017

Rates Fringes

CABLE SPLICER....................$ 39.82 3%+25.44

ELECTRICIAN......................$ 39.49 3%+25.69

ELEC1547-005 04/01/2017

Line Construction

Rates Fringes

CABLE SPLICER....................$ 52.57 3%+30.81

Linemen (Including Equipment Operators, Technician)...........$ 50.52 3%+30.81 Powderman........................$ 48.52 3%+30.81

TREE TRIMMER.....................$ 35.84 3%+22.56

ELEV0019-002 01/01/2017

Rates Fringes

ELEVATOR MECHANIC................$ 53.76 31.585+a+b

FOOTNOTE: a. Employer contributes 8% of the basic hourly rate for over 5 year's service and 6% of the basic hourly rate for 6 months to 5 years' of service as vacation paid credit. b. Eight paid holidays:

New Year's Day; Memorial Day; Independence Day;

Labor Day; Veteran's Day; Thanksgiving Day; Friday after Thanksgiving, and Christmas Day

ENGI0302-002 01/01/2017

Rates Fringes

POWER EQUIPMENT OPERATOR

GROUP 1.....................$ 40.28 22.65

GROUP 1A....................$ 42.04 22.65

GROUP 2.....................$ 39.51 22.65

GROUP 3.....................$ 38.79 22.65

GROUP 4.....................$ 32.58 22.65

TUNNEL WORK

GROUP 1....................$ 44.31 22.65

GROUP 1A...................$ 46.24 22.65

GROUP 2....................$ 43.46 22.65

GROUP 3....................$ 42.67 22.65

GROUP 4....................$ 35.84 22.65

POWER EQUIPMENT OPERATOR CLASSIFICATIONS

GROUP 1: Asphalt Roller: Breakdown, Intermediate, and Finish; Back Filler; Barrier Machine (Zipper); Beltcrete with power pack and similar conveyors; Bending Machine;

Boat Coxwains; Bulldozers; Cableways, Highlines and Cablecars; Cleaning Machine; Coating Machine; Concrete Hydro Blaster; Cranes-45 tons and under or 150 foot boom and under (including jib and attachments): (a) Hydralifts or Transporters, all track or truck type,(b) Derricks;

Crushers; Deck Winches-Double Drum; Ditching or Trenching Machine (16 inch or over); Drilling Machines, core, cable, rotary and exploration; Finishing Machine Operator, Concrete Paving, Laser Screed, Sidewalk, Curb and Gutter Machine; Helicopters; Hover Craft, Flex Craft, Loadmaster, Air Cushion, All Terrain Vehicle, Rollagon, Bargecable, Nodwell, and Snow Cat; Hydro Ax: Feller Buncher and similar; Loaders (2 1/2 yards through 5 yards, including all attachments): Forklifts with telescopic boom and swing attachment, Overhead and front end, 2 1/2 yards through 5 yards, Loaders with forks or pipe clamps; Loaders, elevating belt type, Euclid and similar types; Mechanics, Bodyman; Micro Tunneling Machine; Mixers: Mobile type w/hoist combination; Motor Patrol Grader; Mucking Machines:

Mole, Tunnel Drill, Horizontal/Directional Drill Operator, and/or Shield; Operator on Dredges; Piledriver Engineers, L. B. Foster, Puller or similar Paving Breaker; Power Plant, Turbine Operator, 200 k.w. and over (power plants or combination of power units over 300 k.w.); Scrapers-through 40 yards; Service Oiler/Service Engineer; Sidebooms-under 45 tons; Shot Blast Machine; Shovels, Backhoes, Excavators with all attachments, and Gradealls (3 yards and under), Spreaders, Blaw Knox, Cedarapids, Barber Greene, Slurry Machine; Sub-grader (Gurries, Reclaimer, and similar types); Tack tractor; Truck mounted Concrete Pumps, Conveyor, Creter; Water Kote Machine; Unlicensed off road hauler

GROUP 1A: Camera/Tool/Video Operator (Slipline), Cranes-over 45 tons or 150 foot (including jib and attachments): (a) Clamshells and Draglines (over 3 yards),

(b) Tower cranes; Licensed Water/Waste Water Treatment Operator; Loaders over 5 yds.; Certified Welder, Electrical Mechanic, Camp Maintenance Engineer, Mechanic (over 10,000 hours); Motor Patrol Grader, Dozer, Grade Tractor, Roto-mill/Profiler (finish: when finishing to final grade and/or to hubs, or for asphalt); Power Plants: 1000 k.w.

and over; Quad; Screed; Shovels, Backhoes, Excavators with all attachments (over 3 yards), Sidebooms over 45 tons;

Slip Form Paver, C.M.I. and similar types; Scrapers over 40 yards;

GROUP 2: Boiler-fireman; Cement Hog and Concrete Pump Operator; Conveyors (except as listed in group 1); Hoist on steel erection; Towermobiles and Air Tuggers;

Horizontal/Directional Drill Locator;Licensed Grade Technician; Loaders, (i.e., Elevating Grader and Material Transfer Vehicle); Locomotives: rod and geared engines;

Mixers; Screening, Washing Plant; Sideboom (cradling rock drill regardless of size); Skidder; Trencing Machine under 16 inches; Waste/ Waste Water Treatment Operator.

GROUP 3: "A" Frame Trucks, Deck Winches: single power drum;

Bombardier (tack or tow rig); Boring Machine; Brooms-power;

Bump Cutter; Compressor; Farm tractor; Forklift, industrial type; Gin Truck or Winch Truck with poles when used for hoisting; Grade Checker and Stake Hopper; Hoist, Air Tuggers, Elevators; Loaders: (a) Elevating-Athey, Barber Green and similar types (b) Forklifts or Lumber Carrier (on construction job site) (c) Forklifts with Tower (d) Overhead and Front-end, under 2 1/2 yds. Locomotives:Dinkey (air, steam, gas and electric) Speeders; Mechanics (light duty); Oil, Blower Distribution; Post Hole Diggers, mechanical; Pot Fireman (power agitated); Power Plant, Turbine Operator, under 200 k.w.; Pumps-water; Roller-other than Plantmix; Saws, concrete; Skid Steer with all attachments; Straightening Machine; Tow Tractor

GROUP 4: Rig Oiler/Crane Assistant Engineer;Parts and Equipment Coordinator; Swamper (on trenching machines or shovel type equipment); Spotter; Steam Cleaner; Drill Helper.

FOOTNOTE: Groups 1-4 receive 10% premium while performing tunnel or underground work. Rig Oiler/Crane Assistant Engineer shall be required on cranes over 85 tons or over 100 feet of boom.

IRON0751-003 07/01/2015

Rates Fringes

Ironworkers:

BRIDGE, STRUCTURAL,

ORNAMENTAL, REINFORCING

MACHINERY MOVER, RIGGER,

SHEETER, STAGE RIGGER,

BENDER OPERATOR.............$ 36.25 28.05

FENCE, BARRIER INSTALLER....$ 32.75 28.05

GUARDRAIL INSTALLERS........$ 33.75 28.05

GUARDRAIL LAYOUT MAN........$ 33.49 28.05

HELICOPTER, TOWER...........$ 37.25 28.05

LABO0341-005 04/01/2017

Rates Fringes

Laborers: South of the 63rd Parallel & West of Longitude 138 Degrees

GROUP 1.....................$ 30.55 26.72

GROUP 2.....................$ 31.55 26.72

GROUP 3.....................$ 32.45 26.72

GROUP 3A....................$ 35.73 26.72

GROUP 3B....................$ 39.27 24.01

GROUP 4.....................$ 20.12 26.72

TUNNELS, SHAFTS, AND RAISES

GROUP 1....................$ 33.61 26.72

GROUP 2....................$ 34.71 26.72

GROUP 3....................$ 35.70 26.72

GROUP 3A...................$ 39.30 26.72

GROUP 3B...................$ 43.20 24.01

LABORERS CLASSIFICATIONS

GROUP 1: Asphalt Workers (shovelman, plant crew); Brush Cutters; Camp Maintenance Laborer; Carpenter Tenders; Choke Setters, Hook Tender, Rigger, Signalman; Concrete Laborer(curb and gutter, chute handler, grouting, curing, screeding); Crusher Plant Laborer; Demolition Laborer;

Ditch Diggers; Dump Man; Environmental Laborer (asbestos (limited to nonmechanical systems), hazardous and toxic waste, oil spill); Fence Installer; Fire Watch Laborer;

Flagman; Form Strippers; General Laborer; Guardrail Laborer, Bridge Rail Installers; Hydro-Seeder Nozzleman;

Laborers (building); Landscape or Planter; Laying of Decorative Block (retaining walls, flowered decorative block 4 feet and below); Material Handlers; Pneumatic or Power Tools; Portable or Chemical Toilet Serviceman; Pump Man or Mixer Man; Railroad Track Laborer; Sandblast, Pot Tender; Saw Tenders; Scaffold Building and Erecting; Slurry Work; Stake Hopper; Steam Point or Water Jet Operator;

Steam Cleaner Operator; Tank Cleaning; Utiliwalk, Utilidor Laborer and Conduit Installer; Watchman (construction projects); Window Cleaner

GROUP 2: Burning and Cutting Torch; Cement or Lime Dumper or Handler (sack or bulk); Choker Splicer; Chucktender (wagon, airtrack and hydraulic drills); Concrete Laborers (power buggy, concrete saws, pumpcrete nozzleman, vibratorman);

Culvert Pipe Laborer; Cured in place Pipelayer;

Environmental Laborer (marine work, oil spill skimmer operator, small boat operator); Foam Gun or Foam Machine Operator; Green Cutter (dam work); Gunnite Operator; Hod Carriers; Jackhammer or Pavement Breakers (more than 45 pounds);Laying of Decorative Block (retaining walls, flowered decorative block above 4 feet); Mason Tender and Mud Mixer (sewer work); Pilot Car; Plasterer, Bricklayer and Cement Finisher Tenders; Power Saw Operator; Railroad Switch Layout Laborer; Sandblaster; Sewer Caulkers; Sewer Plant Maintenance Man; Thermal Plastic Applicator; Timber Faller, chain saw operator, filer; Timberman

GROUP 3: Alarm Installer; Bit Grinder; Guardrail Machine Operator; High Rigger and tree topper; High Scaler;

Multiplate; Slurry Seal Squeegee Man

GROUP 3A: Asphalt Raker, Asphalt Belly dump lay down; Drill Doctor (in the field); Drillers (including, but not limited to, wagon drills, air track drills; hydraulic drills);

Powderman; Pioneer Drilling and Drilling Off Tugger (all type drills); Pipelayers

GROUP 3B: Grade checker (setting or transfering of grade marks, line and grade)

GROUP 4: Final Building Cleanup

TUNNELS, SHAFTS, AND RAISES CLASSIFICATIONS

GROUP 1: Brakeman; Muckers; Nippers; Topman and Bull Gang;

Tunnel Track Laborer

GROUP 2: Burning and Cutting Torch; Concrete Laborers;

Jackhammers; Nozzleman, Pumpcrete or Shotcrete.

GROUP 3: Miner; Retimberman

GROUP 3A: Asphalt Raker, Asphalt Belly dump lay down; Drill Doctor (in the field); Drillers (including, but not limited to, wagon drills, air track drills; hydraulic drills);

Powderman; Pioneer Drilling and Drilling Off Tugger (all type drills); Pipelayers.

GROUP 3B: Grade checker (setting or transfering of grade marks, line and grade)

Tunnel shaft and raise rates only apply to workers regularly employed inside a tunnel portal or shaft collar.

LABO0942-001 04/01/2017

Rates Fringes

Laborers: North of the 63rd Parallel & East of Longitude 138 Degrees

GROUP 1.....................$ 30.55 26.72

GROUP 2.....................$ 31.55 26.72

GROUP 3.....................$ 32.45 26.72

GROUP 3A....................$ 35.73 26.72

GROUP 3B....................$ 39.27 24.01

GROUP 4.....................$ 20.12 26.72

TUNNELS, SHAFTS, AND RAISES

GROUP 1....................$ 33.61 26.52

GROUP 2....................$ 34.71 26.52

GROUP 3....................$ 35.70 26.52

GROUP 3A...................$ 39.30 26.52

GROUP 3B...................$ 43.20 23.81

LABORERS CLASSIFICATIONS

GROUP 1: Asphalt Workers (shovelman, plant crew); Brush Cutters; Camp Maintenance Laborer; Carpenter Tenders; Choke Setters, Hook Tender, Rigger, Signalman; Concrete Laborer(curb and gutter, chute handler, grouting, curing, screeding); Crusher Plant Laborer; Demolition Laborer;

Ditch Diggers; Dump Man; Environmental Laborer (asbestos (limited to nonmechanical systems), hazardous and toxic waste, oil spill); Fence Installer; Fire Watch Laborer;

Flagman; Form Strippers; General Laborer; Guardrail Laborer, Bridge Rail Installers; Hydro-Seeder Nozzleman;

Laborers (building); Landscape or Planter; Laying of Decorative Block (retaining walls, flowered decorative block 4 feet and below); Material Handlers; Pneumatic or Power Tools; Portable or Chemical Toilet Serviceman; Pump Man or Mixer Man; Railroad Track Laborer; Sandblast, Pot Tender; Saw Tenders; Scaffold Building and Erecting; Slurry Work; Stake Hopper; Steam Point or Water Jet Operator;

Steam Cleaner Operator; Tank Cleaning; Utiliwalk, Utilidor Laborer and Conduit Installer; Watchman (construction projects); Window Cleaner

GROUP 2: Burning and Cutting Torch; Cement or Lime Dumper or Handler (sack or bulk); Choker Splicer; Chucktender (wagon, airtrack and hydraulic drills); Concrete Laborers (power buggy, concrete saws, pumpcrete nozzleman, vibratorman);

Culvert Pipe Laborer; Cured in place Pipelayer;

Environmental Laborer (marine work, oil spill skimmer operator, small boat operator); Foam Gun or Foam Machine Operator; Green Cutter (dam work); Gunnite Operator; Hod Carriers; Jackhammer or Pavement Breakers (more than 45 pounds);Laying of Decorative Block (retaining walls, flowered decorative block above 4 feet); Mason Tender and Mud Mixer (sewer work); Pilot Car; Plasterer, Bricklayer and Cement Finisher Tenders; Power Saw Operator; Railroad Switch Layout Laborer; Sandblaster; Sewer Caulkers; Sewer Plant Maintenance Man; Thermal Plastic Applicator; Timber Faller, chain saw operator, filer; Timberman

GROUP 3: Alarm Installer; Bit Grinder; Guardrail Machine Operator; High Rigger and tree topper; High Scaler;

Multiplate; Slurry Seal Squeegee Man

GROUP 3A: Asphalt Raker, Asphalt Belly dump lay down; Drill Doctor (in the field); Drillers (including, but not limited to, wagon drills, air track drills; hydraulic drills);

Powderman; Pioneer Drilling and Drilling Off Tugger (all type drills); Pipelayers

GROUP 3B: Grade checker (setting or transfering of grade marks, line and grade)

GROUP 4: Final Building Cleanup

TUNNELS, SHAFTS, AND RAISES CLASSIFICATIONS

GROUP 1: Brakeman; Muckers; Nippers; Topman and Bull Gang;

Tunnel Track Laborer

GROUP 2: Burning and Cutting Torch; Concrete Laborers;

Jackhammers; Nozzleman, Pumpcrete or Shotcrete.

GROUP 3: Miner; Retimberman

GROUP 3A: Asphalt Raker, Asphalt Belly dump lay down; Drill Doctor (in the field); Drillers (including, but not limited to, wagon drills, air track drills; hydraulic drills);

Powderman; Pioneer Drilling and Drilling Off Tugger (all type drills); Pipelayers.

GROUP 3B: Grade checker (setting or transfering of grade marks, line and grade)

Tunnel shaft and raise rates only apply to workers regularly employed inside a tunnel portal or shaft collar.

PAIN1959-001 09/01/2015

NORTH OF THE 63RD PARALLEL

Rates Fringes

PAINTER

BRUSH/ROLLER PAINT OR WALL

COVERER.....................$ 32.07 20.01

TAPING, TEXTURING,

STRUCTURAL PAINTING,

SANDBLASTING, POT TENDER,

FINISH METAL, SPRAY,

BUFFER OPERATOR, RADON

MITIGATION, LEAD BASED

PAINT ABATEMENT, HAZARDOUS

MATERIAL HANDLER............$ 32.59 20.01

PAIN1959-002 02/01/2016

SOUTH OF THE 63RD PARALLEL

Rates Fringes

PAINTER

Brush, Roller, Sign, Paper and Vinyl, Swing Stage, Hand Taper/Drywall, Structural Steel, and Commercial Spray............$ 30.31 19.76 Machine Taper/Drywall.......$ 31.56 19.76 Spray-Sand/Blast, Epoxy and Tar Applicator..........$ 31.66 19.76

PAIN1959-003 01/01/2017

NORTH OF THE 63RD PARALLEL

Rates Fringes

GLAZIER..........................$ 38.63 21.54

PAIN1959-004 07/01/2012

Rates Fringes

FLOOR LAYER: Carpet.............$ 30.09 13.02

PAIN1959-006 01/01/2017

SOUTH OF THE 63RD PARALLEL

Rates Fringes

GLAZIER..........................$ 38.63 20.82

PLAS0867-001 02/01/2016

Rates Fringes

PLASTERER

North of the 63rd parallel..$ 37.25 20.41 South of the 63rd parallel..$ 37.00 20.41

PLAS0867-004 02/01/2016

Rates Fringes

CEMENT MASON/CONCRETE FINISHER

North of the 63rd parallel..$ 37.25 20.41 South of the 63rd parallel..$ 37.00 20.41

PLUM0262-002 01/01/2017

East of the 141st Meridian

Rates Fringes

Plumber; Steamfitter.............$ 38.02 26.72

PLUM0367-002 07/01/2016

South of the 63rd Parallel

Rates Fringes

Plumber; Steamfitter.............$ 39.85 22.85

PLUM0375-002 07/01/2016

North of the 63rd Parallel

Rates Fringes

Plumber; Steamfitter.............$ 40.81 24.25

PLUM0669-002 04/01/2017

Rates Fringes

SPRINKLER FITTER.................$ 46.00 23.29

ROOF0189-006 04/01/2016

Rates Fringes

ROOFER...........................$ 42.62 15.50

SHEE0023-003 07/01/2015

South of the 63rd Parallel

Rates Fringes

SHEET METAL WORKER...............$ 40.79 22.38

SHEE0023-004 07/01/2015

North of the 63rd Parallel

Rates Fringes

SHEET METAL WORKER...............$ 45.93 21.44

TEAM0959-003 09/01/2016

Rates Fringes

TRUCK DRIVER

GROUP 1.....................$ 39.59 21.17

GROUP 1A....................$ 40.86 21.17

GROUP 2.....................$ 38.33 21.17

GROUP 3.....................$ 37.51 21.17

GROUP 4.....................$ 36.93 21.17

GROUP 5.....................$ 36.17 21.17

GROUP 1: Semi with Double Box Mixer; Dump Trucks (including rockbuggy and trucks with pups) over 40 yards up to and including 60 yards; Deltas, Commanders, Rollogans and similar equipment when pulling sleds, trailers or similar equipment; Boat Coxswain; Lowboys including attached trailers and jeeps, up to and including 12 axles; Ready-mix over 12 yards up to and including 15 yards); Water Wagon (250 Bbls and above); Tireman, Heavy Duty/Fueler

GROUP 1A: Dump Trucks (including Rockbuggy and Trucks with pups) over 60 yards up to and including 100 yards; Jeeps (driver under load)

GROUP 2: Turn-O-Wagon or DW-10 not self-loading; All Deltas, Commanders, Rollogans, and similar equipment; Mechanics;

Dump Trucks (including Rockbuggy and Trucks with pups) over 20 yards up to and including 40 yards; Lowboys including attached trailers and jeeps up to and including 8 axles;

Super vac truck/cacasco truck/heat stress truck; Ready-mix over 7 yards up to and including 12 yards; Partsman;

Stringing Truck

GROUP 3: Dump Trucks (including Rockbuggy and Trucks with pups) over 10 yards up to and including 20 yards; batch trucks 8 yards and up; Oil distributor drivers; Oil Distributor Drivers; Trucks/Jeeps (push or pull); Traffic Control Technician

GROUP 4: Buggymobile; Semi or Truck and trailer; Dumpster;

Tireman (light duty); Dump Trucks (including Rockbuggy and Truck with pups) up to and including 10 yards; Track Truck Equipment; Grease Truck; Flat Beds, dual rear axle; Hyster Operators (handling bulk aggregate); Lumber Carrier; Water Wagon, semi; Water Truck, dual axle; Gin Pole Truck, Winch Truck, Wrecker, Truck Mounted "A" Frame manufactured rating over 5 tons; Bull Lifts and Fork Lifts with Power Boom and Swing attachments, over 5 tons; Front End Loader with Forks; Bus Operator over 30 passengers; All Terrain Vehicles; Boom Truck/Knuckle Truck over 5 tons; Foam Distributor Truck/dual axle; Hydro-seeders, dual axle;

Vacuum Trucks, Truck Vacuum Sweepers; Loadmaster (air and water); Air Cushion or similar type vehicle; Fire Truck/Ambulance Driver; Combination Truck-fuel and grease;

Compactor (when pulled by rubber tired equipment); Rigger (air/water/oilfield); Ready Mix, up to and including 7 yards;

GROUP 5: Gravel Spreader Box Operator on Truck; Flat Beds, single rear axle; Boom Truck/Knuckle Truck up to and including 5 tons; Pickups (Pilot Cars and all light duty vehicles); Water Wagon (Below 250 Bbls); Gin Pole Truck, Winch Truck, Wrecker, Truck Mounted "A" Frame, manufactured rating 5 tons and under; Bull Lifts and Fork Lifts (fork lifts with power broom and swing attachments up to and including 5 tons); Buffer Truck; Tack Truck; Farm type Rubber Tired Tractor (when material handling or pulling wagons on a construction project); Foam Distributor, single axle; Hydro-Seeders, single axle; Team Drivers (horses, mules and similar equipment); Fuel Handler (station/bulk attendant); Batch Truck, up to and including 7 yards;

Gear/Supply Truck; Bus Operator, Up to 30 Passengers;

Rigger/Swamper

WELDERS - Receive rate prescribed for craft performing operation to which welding is incidental.

Note: Executive Order (EO) 13706, Establishing Paid Sick Leave for Federal Contractors applies to all contracts subject to the Davis-Bacon Act for which the contract is awarded (and any solicitation was issued) on or after January 1, 2017. If this contract is covered by the EO, the contractor must provide employees with 1 hour of paid sick leave for every 30 hours they work, up to 56 hours of paid sick leave each year.

Employees must be permitted to use paid sick leave for their own illness, injury or other health-related needs, including preventive care; to assist a family member (or person who is like family to the employee) who is ill, injured, or has other health-related needs, including preventive care; or for reasons resulting from, or to assist a family member (or person who is like family to the employee) who is a victim of, domestic violence, sexual assault, or stalking. Additional information on contractor requirements and worker protections under the EO is available at www.dol.gov/whd/govcontracts.

Unlisted classifications needed for work not included within the scope of the classifications listed may be added after award only as provided in the labor standards contract clauses (29CFR 5.5 (a) (1) (ii)).

The body of each wage determination lists the classification and wage rates that have been found to be prevailing for the cited type(s) of construction in the area covered by the wage determination. The classifications are listed in alphabetical order of "identifiers" that indicate whether the particular rate is a union rate (current union negotiated rate for local), a survey rate (weighted average rate) or a union average rate (weighted union average rate).

Union Rate Identifiers

A four letter classification abbreviation identifier enclosed in dotted lines beginning with characters other than "SU" or "UAVG" denotes that the union classification and rate were prevailing for that classification in the survey. Example:

PLUM0198-005 07/01/2014. PLUM is an abbreviation identifier of the union which prevailed in the survey for this classification, which in this example would be Plumbers. 0198 indicates the local union number or district council number where applicable, i.e., Plumbers Local 0198. The next number, 005 in the example, is an internal number used in processing the wage determination. 07/01/2014 is the effective date of the most current negotiated rate, which in this example is July 1, 2014.

Union prevailing wage rates are updated to reflect all rate changes in the collective bargaining agreement (CBA) governing this classification and rate.

Survey Rate Identifiers

Classifications listed under the "SU" identifier indicate that no one rate prevailed for this classification in the survey and the published rate is derived by computing a weighted average rate based on all the rates reported in the survey for that classification. As this weighted average rate includes all rates reported in the survey, it may include both union and non-union rates. Example: SULA2012-007 5/13/2014. SU indicates the rates are survey rates based on a weighted average calculation of rates and are not majority rates. LA indicates the State of Louisiana. 2012 is the year of survey on which these classifications and rates are based. The next number, 007 in the example, is an internal number used in producing the wage determination. 5/13/2014 indicates the survey completion date for the classifications and rates under that identifier.

Survey wage rates are not updated and remain in effect until a new survey is conducted.

Union Average Rate Identifiers

Classification(s) listed under the UAVG identifier indicate that no single majority rate prevailed for those classifications; however, 100% of the data reported for the classifications was union data. EXAMPLE: UAVG-OH-0010 08/29/2014. UAVG indicates that the rate is a weighted union average rate. OH indicates the state. The next number, 0010 in the example, is an internal number used in producing the wage determination. 08/29/2014 indicates the survey completion date for the classifications and rates under that identifier.

A UAVG rate will be updated once a year, usually in January of each year, to reflect a weighted average of the current negotiated/CBA rate of the union locals from which the rate is based.

WAGE DETERMINATION APPEALS PROCESS

1.) Has there been an initial decision in the matter? This can be:

* an existing published wage determination

* a survey underlying a wage determination

* a Wage and Hour Division letter setting forth a position on a wage determination matter

* a conformance (additional classification and rate) ruling

On survey related matters, initial contact, including requests for summaries of surveys, should be with the Wage and Hour Regional Office for the area in which the survey was conducted because those Regional Offices have responsibility for the Davis-Bacon survey program. If the response from this initial contact is not satisfactory, then the process described in 2.)

and 3.) should be followed.

With regard to any other matter not yet ripe for the formal process described here, initial contact should be with the Branch of Construction Wage Determinations. Write to:

Branch of Construction Wage Determinations Wage and Hour Division U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

2.) If the answer to the question in 1.) is yes, then an interested party (those affected by the action) can request review and reconsideration from the Wage and Hour Administrator (See 29 CFR Part 1.8 and 29 CFR Part 7). Write to:

Wage and Hour Administrator U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

The request should be accompanied by a full statement of the interested party's position and by any information (wage payment data, project description, area practice material, etc.) that the requestor considers relevant to the issue.

3.) If the decision of the Administrator is not favorable, an interested party may appeal directly to the Administrative Review Board (formerly the Wage Appeals Board). Write to:

Administrative Review Board U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

4.) All decisions by the Administrative Review Board are final.

END OF GENERAL DECISION

AM 08...

equal to spray or roller applied, one component, polymer modified or elastomeric bitumen, liquid membrane. Water vapor migration resistance shall be equal to or less than of 0.06 Perm (Class I per ASTM E-96 Procedure A) and be compatible with application substrate. Color to be manufacturer’s standard.

b. At locations where vapor retarder is installed over exposed plastic insulation or spray-applied foam insulation, quality standard shall be equal to spray or roller applied low/no VOC synthetic resin, acrylic top coat, water based latex emulsion or closed cell polyurethane suitable for use with plastic insulation. Water vapor migration resistance shall be less than 0.06 Perm (Class I per ASTM E-96 Procedure A) and have a fire-rating meeting Class 1, Class A flame spread ratings per ASTM E 84 or be approved for use as a thermal/ignition barrier per UL 1715 Fire Test of Interior Finish Materials. Color to white, off-white or light gray.

c. At locations where vapor retarder is installed over exposed wall finishes (gypsum wall board, wood paneling, metals or other architectural finishes materials), quality standard shall be equal to spray or roller applied, low/no VOC synthetic resin, water based latex emulsion or latex primer sealer with a water vapor migration resistance of less than 0.06 Perm (Class I per ASTM E-96 Procedure A), have flame spread ratings as required by 2015 IBC for Interior Finishes, be tested in accordance with ASTM E 84 and be compatible with application substrate and finish paint coatings.

Color to be white, off-white or neutral base.

d. Brush, roller or spray-applied vapor barrier products shall be applied per manufacturer’s instructions and shall not be thinned to improve application ease or be color tinted without expressed approval of the manufacturer. Color coats (finish paint coatings) if used, shall be through independent painting process with paint products compatible with vapor barrier coating as approved by the vapor barrier coating manufacturer.

F. Air Barrier - Continuous air barrier shall be installed throughout the building envelope. Air barrier system leakage shall not exceed must not exceed 0.4 cfm/ft2 (2.00 L/s-m2) when test results are extrapolated to 0.3 inches water (75 Pa). AM08.. Use of 0.2 inches water (50 Pa) test pressure allows for the use of the building HVAC system to provide test pressure. Determine air leakage pathways using ASTM E 1186-03 Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems, and perform corrective work as necessary to achieve the whole building air leakage rate specified above and any more stringent requirements for building performance standards required elsewhere in this

RFP…AM08

1. Contractor to provide mockup of air barrier installation for approval by the Contracting Officer or Contracting Officer’s appointed representative.

2.3.10 Exterior Signage

A. Signage shall be integrated into the building and site design in an attractive manner, in accordance with Air Force sign standard in UFC 3-120-01, exterior identification signs, and regulatory and parking regulation signs.

2.3.11 Glazing

A. Glazing for Fire-Rated Windows: UL listed and rated in accordance with ASTM E 2010.

Wired glass shall be Type II flat type, class 1, q7 decorative, form 1 wired and polished both sides conforming to ASTM C1036.

B. Windows shall bear an identifying UL label or the label of a nationally recognized testing agency as tested in accordance with NFPA 257.

C. Fire/safety rated glass shall be laminated Type 1 transparent flat type, class 1 clear,

ii. Server/Communications Rooms

Temperature +75F

Humidity 50 %

iii. Sleeping Rooms 78F for 90% of the time.

iv. Mechanical Rooms +85F *

v. Electrical Rooms +85F

* See item m. below.

e. Load design criteria: Heating load calculations shall not include people gain, lighting gain and gain from equipment. For cooling load calculations the degree of activity for all people shall be moderately active office work. Lights shall be included in calculations based on the actual quantity/power provided. Any additional equipment furnished under this contract shall also be included in the calculation for the appropriate space. Comfort cooling shall be by outdoor ventilation only and shall be sized such that the space temperature of areas cooled for comfort be 78 degrees Fahrenheit or less 90% of the year. Loads such as the pick-up heating load for the Apparatus Bay and snow melt system loads which do not occur concurrently may be considered in the diversity of the total facility heating load.

f. Ventilation air: Calculations determining minimum outside ventilation air and exhaust shall be provided for each building space. Ventilation rates shall be in accordance with the current edition of the ASHRAE 62.1. Ventilation shall be at a continuous rate. Outside air quantities shall be sufficient to meet ventilation requirements. Outside air quantities and exhaust air quantities shall be sufficient to maintain the following pressure relationships:

i. Maintain a neutral pressure 1) inside the Apparatus Room relative to the outdoors.

ii. Maintain a positive pressure 1) Inside in the Administrative/Sleeping area relative to the outdoors and to the Apparatus Room, 2) Inside any Data / Communications Rooms and the Emergency Communications Room relative to adjacent spaces AM08... 3) Inside the Sleeping Rooms relative to adjacent spaces.

iii. Maintain a negative pressure, 1) Inside the Sleeping Rooms relative to adjacent spaces, 2) Inside the Restrooms relative to adjacent spaces, 3) 2) Inside the PPE Storage Room relative to adjacent spaces. ...AM08

g. Storage rooms shall be considered occupiable and shall be ventilated according to their intended storage use.

h. Piping calculations: Calculations shall be provided for pressure drop calculations for all piping systems, including head loss calculations for all pumps.

01 10 00 Para 2.5.2 - Mechanical Systems

Pumps shall have automatic lead/lag feature. Receiver shall be cast iron and shall be provided with condensate return, vent, overflow, inlet strainer, pump suction connections, and a high level alarm connected to the DDC.

iv. Steam and condensate return valves shall be cast steel flanged class 150 for high pressure steam up to and including the steam pressure reducing valve. Bronze valves are allowed only on blowdowns and traps when less than 2”. Bronze valves shall be 300 lb class, bronze body, union bonnet, rising stem, threaded. Threaded valves shall be provided with a union installed adjacent to valve to allow valve removal. Cast Steel valves are allowed only for high pressure steam up to and including the steam pressure reducing station (PRV). Union shall be located on building side and not between the valve and the main.

i. Strainers, basket or Y-type shall be the same size as the pipe in which they are installed. Strainers shall be rated for 125 psi minimum.

j. Steam coils shall not be used.

C. Steam Boiler (Option Item 4)

a. Provide a redundant oil-fired boiler heating system to supply heat to the building.

AM08... Hydronic boilers may be provided, in lieu of steam boilers, if the hydronic boilers are not used to directly heat the building glycol heating media (Indirect heating through an intermediate water to glycol heat exchanger). …AM08

b. Provide a minimum of two boilers, each sized at 60% of building capacity.

c. Provide for manual and automatic switchover of heating systems.

d. Provide fuel storage systems as described under Paragraph J. Fuel Systems below.

D. Hydronic Heating System.

a. The hydronic systems shall be heated using base-wide steam through a steam to glycol heat exchanger as described under section B (Steam Heating System), h (Steam heat exchanger system) above. The temperature of the glycol shall be reset based on the outdoor air temperature.

b. Pumps. Provide inline or base mounted centrifugal pump for each hydronic system provided. Variable speed pump control as an energy savings measure shall be included for motors 1 HP and above, unless the calculated energy savings does not pay for the added costs of equipment and installation within 10 years. Provide flexible connections and pressure gauges on pump inlet and outlet on pumps with capacities greater than 10 gpm. Provide primary and backup pump for each hydronic system provided. Primary and backup pump shall be piped and valved to allow each pump and motor assembly to be removed for service without affecting the operation of the second pump. Strainers shall be provided upstream of each pump.

c. Air separator. Provide air separator for each closed hydronic system. Pipe vent to glycol make up tank.

01 10 00 Para 2.5.2 - Mechanical Systems

SECTION 01 10 00

2.8 HAZARDOUS MATERIALS

A pre-renovation hazardous materials assessment of AM08…old Fire Station Building 251 on Clear AFS has been Building 1337 on Eielson AFB will be…AM08 conducted in anticipation of the current project. Suspect materials will be sampled and analyzed for asbestos, lead, PCBs, mercury, radio isotopes and any other suspect hazardous material encountered during the course of the site assessment. Per 40CFR part 61 29CFR1926and 29CFR1910 an accredited asbestos building inspector will secure representative samples of suspect materials and those samples will be analyzed for asbestos content by an accredited lab. The EM 385-1-1, section 6, enumerates Army Corps of Engineers requirements for conducting construction where the potential exists for the disturbance of asbestos. Materials encountered during the renovation which were not addressed in the referenced assessment should be considered ACM until tested. Unless suspect materials are assessed for asbestos content they must be considered asbestos containing materials (ACM) and handled accordingly.

In addition to asbestos there is the potential for exposure to lead from building components as well as coatings during renovation/construction. Section 6 of EM 385-1-1 contains the requirements for conducting construction where a lead hazard is present.

Supporting Documentation -V.81CLR043 Fire Station

Clear Air Force Station, Alaska

ROOM NO.:126

FUNCTIONAL USE:

OPTIMAL SIZE

NAME: Physical Therapy

Width Depth Height: 10’-0” Area: 138 sq ft

ELECTRICAL POWER REQUIREMENTS:

Voltage: Phase: Hertz: Cycle: Location(s}:

Security System(s} Req.:

Data System(s} Req

Communication System(s} Req yes no no no type type type

HEATING & COOLING REQUIREMENTS:

Temp. Range: Humidity Air: Cleanliness Req

Special Req

PLUMBING & PIPING REQUIREMENTS

Sinks: no

Safety Shower no

Compressed Air: no

Gas Lines: no

POL Supply Lines no

STRUCTURAL REQUIREMENTS:

Column Free

Vibration Control yes no nla

Especially Heavy Equipment

SPECIAL EQUIPMENT

no type

Type: whir1pool Width Depth Height

STORAGE REQUIREMENTS (type, size,location,etc.):

weight

COMMENTS: Floor drain. Self contained coed sauna and hydro therapeutic whirlpool. Visual and audible alarms controlled from comm.control rm. AM08...

Therapeutic whirlpool to be mobile type, 110 gallon, fully welded seams and seamless coved bottom, type 304 stainless steel, swiveling caster wheels, adjustable jet 1/2 horsepower turbine, dual scale thermometer; Basis of design is Medical Supplies & Equipment Co. #M011SWHM...AM08

B - Room Criteria Sheets

Supporting Documentation - V.82CLR043 Fire Station

Clear Air Force Station, Alaska

ROOM NO.:127

FUNCTIONAL USE:

OPTIMAL SIZE

NAME: Sauna

Width Depth Height Area: 102 sq ft

ELECTRICAL POWER REQUIREMENTS:

Voltage: Phase: Hertz: Cycle: Location(s):

Security System(s) Req.:

Data System(s) Req yes yes no type no type

Communication System(s) Req yes

HEATING & COOLING REQUIREMENTS:

Temp. Range: Humidity Air: Cleanliness Req no type

Special Req

PLUMBING & PIPING REQUIREMENTS

Sinks:

Safety Shower

Compressed Air:

Gas Lines:

POL Supply Lines

STRUCTURAL REQUIREMENTS:

Column Free .

Vibration Control

Especially Heavy Equipment

SPECIAL EQUIPMENT

no no no no no yes no yes no n/a type

Type Width Depth Height

STORAGE REQUIREMENTS (type,size, location,etc.):

weight

COMMENTS: See Physical therapy data sheet.AM08... Basis of Design is Finlandia Sauna Model FPF89, two bench tiers 6 person, cedar finished, door to have vision light, exterior controls, wall mounted stainless steal electric element heater...AM08

Supporting Documentation -V.26CLR043 Fire Station Clear Air Force Station, Alaska

ROOM NO.: 137 NAME: Fire Chief Bedroom

FUNCTIONAL USE: Space for separatebedroom sharing an adjacent restroom with assistant fire chief - operations

OPTIMAL SIZE Width Depth Height Area: 121 sq ft

ELECTRICAL POWER REQUIREMENTS:

Voltage: Phase: Hertz: Cycle: Location(s):

Security System(s) Req.:

Data System(s) Req yes no yes type type

Communication System(s) Req yes

HEATING & COOLING REQUIREMENTS:

Temp. Range: Humidity Air: Cleanliness Req

Special Req type

PLUMBING & PIPING REQUIREMENTS

Sinks:

Safety Shower

Compressed Air:

Gas Lines:

POL Supply Lines

STRUCTURAL REQUIREMENTS:

Column Free

Vibration Control yes yes no no no no no n/a

Especially Heavy Equipment

SPECIAL EQUIPMENT

no type

Type Width Depth Height weight

STORAGE REQUIREMENTS (type, size, location,etc.):

Two lockable closets.

COMMENTS: (1) bed with storage below, (1) night stand, (1) desk and chair,

(1) lamp and (1) TV. Minimum STC rating of 45 in walls. AM08...Comm: one government phone, one commercial phone, one fiber connection, one

CC1V connection, two government data ports....AM08

Supporting Documentation - V.94CLR043…