Technical_Exhibit_C-_Drawings_(Revision)_16-T-0269_Ft_Hood_Replace_Failed_Air_Cooled_Chiller_29_August_16.pdf
PDF 1 MB Posted
- Attached to
- Replace Failed Air-Cooled Chiller
- Solicitation number
- W91151-16-T-0269
About this file
Revised Drawings
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET
N
1"=200’
INDEX OF DRAWINGS
HWY 84
HWY 84
HWY 36
F .M
RES.BD.
RES.BD.
R E S . B
D
RES. BD.
R E
S .B
D
KILLEEN
CANTONMENT
AREA
WEST
FORT
HOOD
GATESVILLE
NORTH
FORT
HOOD
RESERVATION
BELTON
LAKE
COPPERAS
COVE
HWY190
HWY190
FORT HOOD AREA MAP
O L
D G
E O
R G
E T
O W
N R
D
E A
S T R
A N
G E R
D
N O
LA
N R
D
FORT HOOD
W E S
T R
A N
G E R
D
C L
A R
K E R
D
H W
Y
35 37
LOCATION
PROJECT
LAREDO
CORPUS
CHRISTI
HOUSTON
AUSTIN
KILLEEN
WACO
FORT WORTH DALLAS
FORT
SMITH
OKLAHOMA
CITY
TULSA
AMARILLO
ALBUQUERUE
SANTA FE
VICINITY MAP
LOUISIANA
MEXICO
MEXICO
TEXAS
ARKANSAS
NEW
MEXICO
ELPASO
OKLAHOMA
GULF OF
SAN ANTONIO
FORT HOOD
WICHITA FALLS
N
SCALE IN MILES
1/2 1
FORT HOOD MILITARY RESERVATION
N
0 100 200
SCALE IN MILES
N
0 5 10
SCALE IN MILES
NORTH SYMBOL
GENERAL SYMBOLS
REVISION NUMBER
WALL TYPE MARK
DOOR MARKWINDOW MARK
DETAIL NUMBER
REFERENCE FROM
REFERENCE TO
G-101
C O
V E
R S
H E
E T
FORT HOOD,TEXAS
FORT HOOD DIRECTORATE OF PUBLIC WORKS-ENGINEERING DIVISION
NOTE BY SYMBOL
SHEET DESCRIPTION
A
A
N
A
A
BUILDING LEGEND (POINTS OF INTEREST)
PROJECT SITE
BUILDING 4612 (DIRECTORATE OF PUBLIC WORKS)
DARNALL ARMY HOSPITAL
III CORPS HEADQUARTERS
MAIN CANTONMENT AREA
W E S T R
A N
G E R
D
MONTAGUE VILLAGE
VILLAGEII
COMANCHE
CENTRAL DR
LANDFILL
FT.HOOD
W R
A T
T E
N
PATTON
PARK
BATTALION
NORTH
761ST
NORTH
WALKER VILLAGE
HOOD
ARMY
AIRFIELD
HILLIARD
CENTRAL
TEXAS
COLLEGE
HEIGHTS
WEST
FT.HOOD
VILLAGEIII
MURPHY
TURKEYRUN
T
H
N D
H W
Y
T
H
R
D
M U
R P
H Y
T
H
M A
R T
IN
62ND
WAINWRIGHT
TO
VILLAGEI
COMANCHE
T
H
T
H
LIBERTY VILLAGE
OLD IRONSIDES
BATTALION AVE
HELL ON WHEELSC
L
A R
K E R
O A
D C
L A
R K
E R
O A
D
C L E
A R C
R E
E K
US HIGHWAY 190
HELL ON WHEELS
OLD IRONSIDES
WARRIOR WAY
BUSINESS ROUTE 190
US HIGHWAY 190
PERSHING PARK
VENABLE VILLAGE
CHAFFEE VILLAGE
US HIGHWAY 190
RAIL HEAD
McNair Village
TANK DESTROYER RD
COPPERAS COVE RD
WEST RANGE RD
Santa Fe Av e
WAREHOUSE AVE
DESTROYER RD
TANK
COPP
ERAS
COVE
RD
O L
D G
E O
R G
R T
O W
N R
D
TURKEYRUN
C L E
A R C
R E
E K
T
H
EAST
R
AN
G E
R D
NORTH NOLAN RD
WEST RANCIER AVE
SOUTH RANGE RD
F T H
O O
D S
T
T .J
M
IL
L S B
L V
D
PROJECT NO: 13900986P
AIR-COOLED CHILLER
REPLACE FAILED
MECHANICAL SCHEDULEM-601
MECHANICAL PLANM-101
DEMO PLAND-101
COVER SHEETG-101
B P
R E
S S
E R
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E O
F
A B C D E F
D a te
D e s c ri p ti o n
DPW
FORT HOOD TEXAS
n oi sivi
D secivreS & gn ir ee ni g n
E
D ir ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/2
/2
:1
:3
P
M G E
N G
S
V C \E
N G
IN
E E
R
IN
G
P ro je c ts \1
P R
E P
L A
C E F
A
IL
E D A
IR
-C
O O
L E
D C
H
IL
L E
R B
L D
G
\F lo o rp la n s
D e s ig n \G -1
C o v e r S h e e t.
d g n
39009
13900986P
B P
R E
S S
E R
-A
P R -2
A
IR
-C
O O
L E
D C
H
IL
L E
R R
E P
L A
C E F
A
IL
E D
SUPPORT AVE
SUPPORT AVE
TRAINING RD
T R
A
IN
IN
G
R D
39011
28008
39015
39046
39013
28009
39012
39019
39036
39032
39034
28006
39027
39008
39033
39031
39010
39009
39016
39014
D-101N SCALE: 3/8" = 1’
SCALE (FEET)
0 4 62
B P
R E
S S
E R
GENERAL NOTES:KEY NOTES:
D E
M O P
L A
N
DEMO PLAN
ELECTRICAL CONDUIT AS POSSIBLE.
CONTRACTOR SHALL PRESERVE AND REUSE AS MUCH EXISTING, ABOVE-GROUND6.
ELECTRICAL CONDUIT.
CONTRACTOR SHALL PRESERVE AND REUSE ALL EXISTING, UNDERGROUND5.
UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL PRESERVE AND REUSE ALL EXISTING CHILLED-WATER PIPING,4.
NFPA 101 (LIFE SAFETY CODE).
STANDARD PLUMBING CODE, NFPA 13, NFPA 70 (NATIONAL ELECTRIC CODE), AND
INCLUDE, BUT ARE NOT LIMITED TO, INTERNATIONAL BUILDING CODE, NATIONAL
SPECIAL PROVISIONS, TERMS AND CONDITIONS. APPLICABLE CODES AND STANDARDS
MANUFACTURER�S SPECIFICATIONS AND RECOMMENDATIONS, AND ALL CONTRACT
LAWS AND REGULATIONS, INDUSTRY AND CONSTRUCTION CODES AND STANDARDS,
ALL WORK FOR THIS PROJECT SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL3.
DAY AND IMPLEMENT A PLAN TO PREVENT UNINTENDED ACCESS.
CONTRACTOR SHALL KEEP WORK AREA CLEAN AND ORGANIZED DURING THE WORK2.
EXECUTION.
CONTRACTOR SHALL FIELD VERIFY EXISTING SITE CONDITIONS PRIOR TO WORK1.
CONTRACTOR SHALL DEMOLISH THE EXISTING CHILLER DISCONNECT.
EXISTING CHILLER.
CONTRACTOR SHALL DEMOLISH THE EXISTING WIRING BETWEEN THE EXISTING CHILLER DISCONNECT AND THE
(MDP) IN ROOM 125 AND THE EXISTING CHILLER DISCONNECT.
CONTRACTOR SHALL DEMOLISH THE EXISTING WIRING BETWEEN THE EXISTING MAIN DISTRIBUTION PANEL
CHILLER AND THE EXTERIOR WALL OF ROOM 125.
CONTRACTOR SHALL DEMOLISH THE EXISTING, ABOVE-GRADE CHILLED-WATER PIPING BETWEEN THE EXISTING
THERMOMETERS, FLEXIBLE CONNECTORS, AND FLOW SWITCHES SERVING THE EXISTING CHILLER.
CONTRACTOR SHALL DEMOLISH ALL EXISTING ISOLATION (BUTTERFLY) VALVES, PRESSURE GAUGES, CONTRACTOR SHALL DEMOLISH THE EXISTING AIR-COOLED CHILLER (CH-1).
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E
D a te
D e s c ri p ti o n sivi
D secivreS & gn ir ee ni g n
E
D ir ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/2
/2
:1
:3
P
M G E
N G
S
V C \E
N G
IN
E E
R
IN
G
P ro je c ts \1
P R
E P
L A
C E F
A
IL
E D A
IR
-C
O O
L E
D C
H
IL
L E
R B
L D
G
\F lo o rp la n s
D e s ig n \D -1
.d g n
39009
13900986P
B P
R E
S S
E R
-A
P R -2
A
IR
-C
O O
L E
D C
H
IL
L E
R R
E P
L A
C E F
A
IL
E D
LANDING
CH-1
CHWP-1
CHS
CHR
MECHANICAL
OFFICE
C O
R R
ID
O R
CHEMO
CALL LNO
EXISTING CHILLER
EXISTING FLOW SWITCH
EXISTING MDP
EXISTING CHILLER DISCONNECT
LEGEND:
EXISTING PIPING TO REMAIN
EXISTING PIPING TO BE DEMOLISHED
EXISTING ELECTRICAL DISCONNECT
EXISTING THERMOMETER
EXISTING PRESSURE GAUGE
EXISTING BUTTERFLY VALVE
BRIAN.E.PRESSER
Polygon
BRIAN.E.PRESSER
Callout
ADDED KEY NOTE FOR CLARIFICATION
BRIAN.E.PRESSER
Polygon
BRIAN.E.PRESSER
Callout
REMOVED BALANCING VALVE SYMBOL
BRIAN.E.PRESSER
Polygon
BRIAN.E.PRESSER
Callout
REMOVED ENTRY FOR EXISTING BALANCING VALVE
M-101N SCALE: 3/8" = 1’
SCALE (FEET)
0 4 62
B P
R E
S S
E R
GENERAL NOTES:KEY NOTES:
MECHANICAL PLAN
M E
C H
A N
IC
A L P
L A
N
DISPOSE OF USED REFRIGERANT PER SPECS.
CONTRACTOR SHALL DISPOSE OF ALL DEMOLISHED EQUIPMENT OFF-SITE AND9.
EXISTING ELECTRIC UTILITIES AND PIPE SIZES PRIOR TO ORDERING.
CONTRACTOR SHALL VERIFY THAT ALL NEW EQUIPMENT IS COMPATIBLE WITH8.
FOR INSTALLATION FOR THIS PROJECT.
AND SHALL BE ADJUSTED TO REFLECT NEW EQUIPMENT SUBMITTED AND APPROVED
DISCONNECTS, WIRES, AND CONDUIT, ARE SIZED FOR EXISTING EQUIPMENT ONLY
ALL EXISTING ELECTRICAL DEVICES, INCLUDING CIRCUIT BREAKERS, FUSES,7.
ALL NEW WIRING FOR EQUIPMENT SHALL BE COPPER.6.
WIRING, INSULATION, AND ALUMINUM JACKETING.
ALL EXTERIOR, ABOVE-GRADE CHILLED-WATER PIPING SHALL FEATURE HEAT-TRACE5.
EXECUTION PER SPECS.
CONTRACTOR SHALL REINSULATE ALL PIPING THAT IS DISTURBED BY WORK4.
NFPA 101 (LIFE SAFETY CODE).
STANDARD PLUMBING CODE, NFPA 13, NFPA 70 (NATIONAL ELECTRIC CODE), AND
INCLUDE, BUT ARE NOT LIMITED TO, INTERNATIONAL BUILDING CODE, NATIONAL
SPECIAL PROVISIONS, TERMS AND CONDITIONS. APPLICABLE CODES AND STANDARDS
MANUFACTURER�S SPECIFICATIONS AND RECOMMENDATIONS, AND ALL CONTRACT
LAWS AND REGULATIONS, INDUSTRY AND CONSTRUCTION CODES AND STANDARDS,
ALL WORK FOR THIS PROJECT SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL3.
DAY AND IMPLEMENT A PLAN TO PREVENT UNINTENDED ACCESS.
CONTRACTOR SHALL KEEP WORK AREA CLEAN AND ORGANIZED DURING THE WORK2.
EXECUTION.
CONTRACTOR SHALL FIELD VERIFY EXISTING SITE CONDITIONS PRIOR TO WORK1.
3 4 10
CONDUCTORS AND ONE #2 CONDUCTOR FOR GROUNDING.
THIS DISCONNECT AND THE NEW CHILLER. EACH OF THESE WIRES SHALL CONTAIN THREE #4/0, THWN
DISCONNECT IN A NEMA 3 ENCLOSURE. CONTRACTOR SHALL INSTALL TWO NEW WIRES IN PARALLEL BETWEEN
POWER TO THE NEW CHILLER SHALL BE CONTROLLED BY A NEW, 600 AMP, HEAVY-DUTY, NON-FUSED
SHALL CONTAIN TWO #22, UNSHIELDED CONDUCTORS.
CONTROLLER TO ALLOW FOR FUTURE CONNECTION OF A LONWORKS INTERFACE CARD. EACH OF THESE WIRES
SHALL ALSO RUN TWO NEW WIRES FROM THE NEW CHILLER’S CONTROLLER TO THE EXISTING DDC
CONTROLLER IN ROOM 125 AND RECONNECT IT TO THE NEW CHILLER AFTER INSTALLATION. CONTRACTOR
CONTRACTOR SHALL PRESERVE THE EXISTING ENABLE AND STATUS WIRING FROM THE EXISTING DDC
THE NEW CHILLER.
CONTRACTOR SHALL INSTALL A NEW ISOLATION (BUTTERFLY) VALVE INSIDE ROOM 125 ON THE RETURN SIDE OF
CONTRACTOR SHALL DRAIN THE EXISTING CHILLED-WATER PIPING SYSTEM.
AND FLEXIBLE CONNECTORS TO SERVE THE NEW CHILLER.
CONTRACTOR SHALL INSTALL NEW ISOLATION (BUTTERFLY) VALVES, PRESSURE GAUGES, THERMOMETERS, CHILLED-WATER PIPING SYSTEM. SEE M-601 FOR SIZING AND CAPACITY DETAILS.
CONTRACTOR SHALL INSTALL A NEW AIR-COOLED CHILLER (CH-1) AND RECONNECT IT TO THE EXISTING
RESPONSIBLE FOR CHEMICALLY TREATING THIS WATER.
WATER PIPING SYSTEM USING MAKE-UP WATER FROM THE BUILDING. CONTRACTOR SHALL NOT BE
AFTER ALL NEW EQUIPMENT IS INSTALLED FOR THIS PROJECT, CONTRACTOR SHALL REFILL THE CHILLED-
MAY BE REUSED, HOWEVER, CONTRACTOR SHALL EXPAND IT IF IT IS UNDERSIZED.
NEW CHILLER SHALL BE PLACED ON A FORMED-AND-PLACED CONCRETE PAD PER SPECS. THE EXISTING PAD
THWN CONDUCTORS AND ONE #2 CONDUCTOR FOR GROUNDING.
BETWEEN THE MDP AND THE NEW CHILLER DISCONNECT. EACH OF THESE WIRES SHALL CONTAIN THREE #4/0, BE REUSED IF THEY ARE PROPERLY SIZED. CONTRACTOR SHALL INSTALL TWO NEW WIRES IN PARALLEL
BUCKET-TYPE BREAKER IN THE EXISTING MAIN DISTRIBUTION PANEL (MDP) IN ROOM 125. EXISTING FUSES MAY
OVERCURRENT PROTECTION FOR THE NEW CHILLER SHALL BE PROVIDED BY 500 AMP FUSES IN THE EXISTING, ROOM 125.
IN THE EXISTING CONDUIT FROM THIS DISCONNECT NEAR WHERE IT PASSES THROUGH THE EXTERIOR WALL OF
AND RECONNECT IT TO THE NEW CHILLER AFTER INSTALLATION. CONTRACTOR SHALL ALSO REPAIR A BREAK
DISCONNECT IN ROOM 125. CONTRACTOR SHALL PRESERVE THE EXISTING WIRING FROM THIS DISCONNECT
POWER TO THE NEW CHILLER’S CONTROLLER SHALL BE CONTROLLED BY THE EXISTING CHILLER CONTROLLER
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E
D a te
D e s c ri p ti o n sivi
D secivreS & gn ir ee ni g n
E
D ir ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/2
/2
:1
:3
P
M G E
N G
S
V C \E
N G
IN
E E
R
IN
G
P ro je c ts \1
P R
E P
L A
C E F
A
IL
E D A
IR
-C
O O
L E
D C
H
IL
L E
R B
L D
G
\F lo o rp la n s
D e s ig n \M
-1 .d g n
39009
13900986P
B P
R E
S S
E R
-A
P R -2
A
IR
-C
O O
L E
D C
H
IL
L E
R R
E P
L A
C E F
A
IL
E D
LANDING
CH-1
CHWP-1
CHS
CHR
MECHANICAL
OFFICE
C O
R R
ID
O R
CHEMO
CALL LNO
CONTROL PANEL
EXISTING DDC
NEW CHILLER
NEW FLOW SWITCH
EXISTING MDP
NEW CHILLER DISCONNECT
DISCONNECT
CONTROLLER
EXISTING CHILLER
LEGEND:
EXISTING PIPING TO REMAIN
NEW PIPING
NEW ELECTRICAL DISCONNECT
EXISTING ELECTRICAL DISCONNECT
NEW THERMOMETER
NEW PRESSURE GAUGE
NEW BUTTERFLY VALVE
BRIAN.E.PRESSER
Polygon
BRIAN.E.PRESSER
Callout
REMOVED BALANCING VALVE SYMBOL
BRIAN.E.PRESSER
Polygon
BRIAN.E.PRESSER
Callout
ADDED ISOLATION VALVE SYMBOL
BRIAN.E.PRESSER
Polygon
BRIAN.E.PRESSER
Callout
ADDED KEY NOTES FOR CLARIFICATION AND TO REQUEST A NEW ITEM OF WORK
BRIAN.E.PRESSER
Polygon
BRIAN.E.PRESSER
Callout
ADDED KEY NOTE FOR CLARIFICATION
BRIAN.E.PRESSER
Polygon
BRIAN.E.PRESSER
Callout
REMOVED ENTRY FOR EXISTING BALANCING VALVE
M-601
B P
R E
S S
E R
M E
C H
A N
IC
A L S
C H
E D
U L E
SYMBOL
GPM
MINIMUM EER
55CH-1
(TONS)
CAPACITY
POWER SUPPLY
VOLTAGEPHASE
(HZ)
CYCLE
60 208/230345
(°F)
TEMPERATURE
LEAVING
(°F)
TEMPERATURE
ENTERING
CHILLED WATER
(°F)
TEMPERATURE
AIR
AMBIENT
95 4
AIR-COOLED CHILLER SCHEDULE
COMPRESSORS
NUMBER OF
MINIMUM
TYPE
REFRIGERANT
R410A 189 9.878.2
MINIMUM EER LISTED IS AT AHRI CONDITIONS.5.
UNIT SHALL FEATURE A SINGLE-POINT POWER CONNECTION.4.
UNIT SHALL FEATURE A WIRED, FACTORY-MOUNTED FLOW SWITCH.3.
UNIT SHALL FEATURE A STRAINER ON ITS SUCTION SIDE.3.
UNIT SHALL FEATURE HAIL GUARDS2.
UNIT SHALL FEATURE A LONWORKS INTERFACE CARD.1.
NOTES:
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E
D a te
D e s c ri p ti o n sivi
D secivreS & gn ir ee ni g n
E
D ir ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/2
/2
:1
:3
P
M G E
N G
S
V C \E
N G
IN
E E
R
IN
G
P ro je c ts \1
P R
E P
L A
C E F
A
IL
E D A
IR
-C
O O
L E
D C
H
IL
L E
R B
L D
G
\F lo o rp la n s
D e s ig n \M
-6 .d g n
39009
13900986P
B P
R E
S S
E R
-A
P R -2
A
IR
-C
O O
L E
D C
H
IL
L E
R R
E P
L A
C E F
A
IL
E D
| G-101 Cover Sheet |
| D-101 |
| M-101 |
| M-601 |
File details come from the government source that posted it. Updated .