Technical_Exhibit_B_Drawings_16-T-0269_Ft_Hood_Replace_Failed_Air_Cooled_Chiller_13_July_16.pdf

PDF 1 MB Posted

Attached to
Replace Failed Air-Cooled Chiller
Solicitation number
W91151-16-T-0269
Issued by

About this file

Drawings

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET

N

1"=200’

INDEX OF DRAWINGS

HWY 84

HWY 84

HWY 36

F .M

RES.BD.

RES.BD.

R E S . B

D

RES. BD.

R E

S .B

D

KILLEEN

CANTONMENT

AREA

WEST

FORT

HOOD

GATESVILLE

NORTH

FORT

HOOD

RESERVATION

BELTON

LAKE

COPPERAS

COVE

HWY190

HWY190

FORT HOOD AREA MAP

O L

D G

E O

R G

E T

O W

N R

D

E A

S T R

A N

G E R

D

N O

LA

N R

D

FORT HOOD

W E S

T R

A N

G E R

D

C L

A R

K E R

D

H W

Y

35 37

LOCATION

PROJECT

LAREDO

CORPUS

CHRISTI

HOUSTON

AUSTIN

KILLEEN

WACO

FORT WORTH DALLAS

FORT

SMITH

OKLAHOMA

CITY

TULSA

AMARILLO

ALBUQUERUE

SANTA FE

VICINITY MAP

LOUISIANA

MEXICO

MEXICO

TEXAS

ARKANSAS

NEW

MEXICO

ELPASO

OKLAHOMA

GULF OF

SAN ANTONIO

FORT HOOD

WICHITA FALLS

N

SCALE IN MILES

1/2 1

FORT HOOD MILITARY RESERVATION

N

0 100 200

SCALE IN MILES

N

0 5 10

SCALE IN MILES

NORTH SYMBOL

GENERAL SYMBOLS

REVISION NUMBER

WALL TYPE MARK

DOOR MARKWINDOW MARK

DETAIL NUMBER

REFERENCE FROM

REFERENCE TO

G-101

C O

V E

R S

H E

E T

FORT HOOD,TEXAS

FORT HOOD DIRECTORATE OF PUBLIC WORKS-ENGINEERING DIVISION

NOTE BY SYMBOL

SHEET DESCRIPTION

A

A

N

A

A

BUILDING LEGEND (POINTS OF INTEREST)

PROJECT SITE

BUILDING 4612 (DIRECTORATE OF PUBLIC WORKS)

DARNALL ARMY HOSPITAL

III CORPS HEADQUARTERS

MAIN CANTONMENT AREA

W E S T R

A N

G E R

D

MONTAGUE VILLAGE

VILLAGEII

COMANCHE

CENTRAL DR

LANDFILL

FT.HOOD

W R

A T

T E

N

PATTON

PARK

BATTALION

NORTH

761ST

NORTH

WALKER VILLAGE

HOOD

ARMY

AIRFIELD

HILLIARD

CENTRAL

TEXAS

COLLEGE

HEIGHTS

WEST

FT.HOOD

VILLAGEIII

MURPHY

TURKEYRUN

T

H

N D

H W

Y

T

H

R

D

M U

R P

H Y

T

H

M A

R T

IN

62ND

WAINWRIGHT

TO

VILLAGEI

COMANCHE

T

H

T

H

LIBERTY VILLAGE

OLD IRONSIDES

BATTALION AVE

HELL ON WHEELSC

L

A R

K E R

O A

D C

L A

R K

E R

O A

D

C L E

A R C

R E

E K

US HIGHWAY 190

HELL ON WHEELS

OLD IRONSIDES

WARRIOR WAY

BUSINESS ROUTE 190

US HIGHWAY 190

PERSHING PARK

VENABLE VILLAGE

CHAFFEE VILLAGE

US HIGHWAY 190

RAIL HEAD

McNair Village

TANK DESTROYER RD

COPPERAS COVE RD

WEST RANGE RD

Santa Fe Av e

WAREHOUSE AVE

DESTROYER RD

TANK

COPP

ERAS

COVE

RD

O L

D G

E O

R G

R T

O W

N R

D

TURKEYRUN

C L E

A R C

R E

E K

T

H

EAST

R

AN

G E

R D

NORTH NOLAN RD

WEST RANCIER AVE

SOUTH RANGE RD

F T H

O O

D S

T

T .J

M

IL

L S B

L V

D

PROJECT NO: 13900986P

AIR-COOLED CHILLER

REPLACE FAILED

MECHANICAL SCHEDULEM-601

MECHANICAL PLANM-101

DEMO PLAND-101

COVER SHEETG-101

B P

R E

S S

E R

NUMBER

REFERENCE

SHEET

Project No.

D e s ig n e d B y

D a te

M a rk

Bldg. No.

F T

H O

O D T

E X

A S

S A

N T

A F

E E

N G

IN

E E

R D

R

B

L D

G

F O

R T H

O O

D T

E X

A S

P U

B L

IC

W

O R

K S

D

IR

E C

T O

R A

T E O

F

A B C D E F

D a te

D e s c ri p ti o n

DPW

FORT HOOD TEXAS

n oi sivi

D secivreS & gn ir ee ni g n

E

D ir ec to rat eofPublic

W o rk s

P R

O J E

C T M

A N

A G

E R

P U

R P

O S

E S O

N L

Y F

O R B

ID

D

IN

G T

E C

H N

IC

A L E

X H

IB

IT

B

/1

/2

:5

:0

P

M G E

N G

S

V C \E

N G

IN

E E

R

IN

G

P ro je c ts \1

P R

E P

L A

C E F

A

IL

E D A

IR

-C

O O

L E

D C

H

IL

L E

R B

L D

G

\F lo o rp la n s

D e s ig n \G -1

C o v e r S h e e t.

d g n

39009

13900986P

B P

R E

S S

E R

-A

P R -2

A

IR

-C

O O

L E

D C

H

IL

L E

R R

E P

L A

C E F

A

IL

E D

SUPPORT AVE

SUPPORT AVE

TRAINING RD

T R

A

IN

IN

G

R D

39011

28008

39015

39046

39013

28009

39012

39019

39036

39032

39034

28006

39027

39008

39033

39031

39010

39009

39016

39014

D-101N SCALE: 3/8" = 1’

SCALE (FEET)

0 4 62

B P

R E

S S

E R

GENERAL NOTES:KEY NOTES:

D E

M O P

L A

N

DEMO PLAN

ELECTRICAL CONDUIT AS POSSIBLE.

CONTRACTOR SHALL PRESERVE AND REUSE AS MUCH EXISTING, ABOVE-GROUND6.

ELECTRICAL CONDUIT.

CONTRACTOR SHALL PRESERVE AND REUSE ALL EXISTING, UNDERGROUND5.

UNLESS OTHERWISE NOTED.

CONTRACTOR SHALL PRESERVE AND REUSE ALL EXISTING CHILLED-WATER PIPING,4.

NFPA 101 (LIFE SAFETY CODE).

STANDARD PLUMBING CODE, NFPA 13, NFPA 70 (NATIONAL ELECTRIC CODE), AND

INCLUDE, BUT ARE NOT LIMITED TO, INTERNATIONAL BUILDING CODE, NATIONAL

SPECIAL PROVISIONS, TERMS AND CONDITIONS. APPLICABLE CODES AND STANDARDS

MANUFACTURER�S SPECIFICATIONS AND RECOMMENDATIONS, AND ALL CONTRACT

LAWS AND REGULATIONS, INDUSTRY AND CONSTRUCTION CODES AND STANDARDS,

ALL WORK FOR THIS PROJECT SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL3.

DAY AND IMPLEMENT A PLAN TO PREVENT UNINTENDED ACCESS.

CONTRACTOR SHALL KEEP WORK AREA CLEAN AND ORGANIZED DURING THE WORK2.

EXECUTION.

CONTRACTOR SHALL FIELD VERIFY EXISTING SITE CONDITIONS PRIOR TO WORK1.

CONTRACTOR SHALL DEMOLISH EXISTING CHILLER DISCONNECT.

CHILLER.

CONTRACTOR SHALL DEMOLISH EXISTING WIRING BETWEEN EXISTING CHILLER DISCONNECT AND EXISTING

ROOM 125 AND EXISTING CHILLER DISCONNECT.

CONTRACTOR SHALL DEMOLISH EXISTING WIRING BETWEEN EXISTING MAIN DISTRIBUTION PANEL (MDP) IN

AND EXTERIOR WALL OF ROOM 125.

CONTRACTOR SHALL DEMOLISH EXISTING, ABOVE-GRADE CHILLED-WATER PIPING BETWEEN EXISTING CHILLER

THERMOMETERS, FLEXIBLE CONNECTORS, AND FLOW SWITCHES SERVING EXISTING CHILLER.

CONTRACTOR SHALL DEMOLISH ALL EXISTING ISOLATION (BUTTERFLY) VALVES, PRESSURE GAUGES, CONTRACTOR SHALL DEMOLISH EXISTING AIR-COOLED CHILLER (CH-1).

NUMBER

REFERENCE

SHEET

Project No.

D e s ig n e d B y

D a te

M a rk

Bldg. No.

F T

H O

O D T

E X

A S

S A

N T

A F

E E

N G

IN

E E

R D

R

B

L D

G

F O

R T H

O O

D T

E X

A S

P U

B L

IC

W

O R

K S

D

IR

E C

T O

R A

T E

D a te

D e s c ri p ti o n sivi

D secivreS & gn ir ee ni g n

E

D ir ec to rat eofPublic

W o rk s

P R

O J E

C T M

A N

A G

E R

P U

R P

O S

E S O

N L

Y F

O R B

ID

D

IN

G T

E C

H N

IC

A L E

X H

IB

IT

B

/1

/2

:5

:0

P

M G E

N G

S

V C \E

N G

IN

E E

R

IN

G

P ro je c ts \1

P R

E P

L A

C E F

A

IL

E D A

IR

-C

O O

L E

D C

H

IL

L E

R B

L D

G

\F lo o rp la n s

D e s ig n \D -1

.d g n

39009

13900986P

B P

R E

S S

E R

-A

P R -2

A

IR

-C

O O

L E

D C

H

IL

L E

R R

E P

L A

C E F

A

IL

E D

LANDING

CH-1

CHWP-1

CHS

CHR

MECHANICAL

OFFICE

C O

R R

ID

O R

CHEMO

CALL LNO

EXISTING CHILLER

EXISTING FLOW SWITCH

EXISTING MDP

EXISTING CHILLER DISCONNECT

LEGEND:

EXISTING PIPING TO REMAIN

EXISTING PIPING TO BE DEMOLISHED

EXISTING ELECTRICAL DISCONNECT

EXISTING THERMOMETER

EXISTING PRESSURE GAUGE

EXISTING BALANCING VALVE

EXISTING BUTTERFLY VALVE

BRIAN.E.PRESSER

Polygon

BRIAN.E.PRESSER

Polygon

BRIAN.E.PRESSER

Callout

ADDED KEY NOTE FOR CLARIFICATION

BRIAN.E.PRESSER

Callout

ADDED KEY NOTE SYMBOL

M-101N SCALE: 3/8" = 1’

SCALE (FEET)

0 4 62

B P

R E

S S

E R

GENERAL NOTES:KEY NOTES:

MECHANICAL PLAN

M E

C H

A N

IC

A L P

L A

N

FROM THIS DISCONNECT NEAR WHERE IT PASSES THROUGH EXTERIOR WALL OF ROOM 125.

TO NEW CHILLER AFTER INSTALLATION. CONTRACTOR SHALL ALSO REPAIR BREAK IN EXISTING CONDUIT

IN ROOM 125. CONTRACTOR SHALL PRESERVE EXISTING WIRING FROM THIS DISCONNECT AND RECONNECT IT

POWER TO NEW CHILLER CONTROLS SHALL BE CONTROLLED BY EXISTING CHILLER CONTROLS DISCONNECT

CONDUCTOR FOR GROUNDING.

NEW CHILLER. EACH OF THESE WIRES SHALL CONTAIN THREE #4/0, THWN CONDUCTORS AND ONE #2

DISCONNECT. CONTRACTOR SHALL INSTALL TWO NEW WIRES IN PARALLEL BETWEEN THIS DISCONNECT AND

POWER TO NEW CHILLER SHALL BE CONTROLLED BY A NEW, 600 AMP, HEAVY-DUTY, NEMA 3, NON-FUSED

UNSHIELDED CONDUCTORS.

FUTURE CONNECTION OF A LONWORKS INTERFACE CARD. EACH OF THESE WIRES SHALL CONTAIN TWO #22, NEW WIRES FROM NEW CHILLER’S CONTROL PANEL TO EXISTING DDC CONTROL PANEL TO ALLOW FOR

IN ROOM 125 AND RECONNECT IT TO NEW CHILLER AFTER INSTALLATION. CONTRACTOR SHALL ALSO RUN TWO

CONTRACTOR SHALL PRESERVE EXISTING ENABLE AND STATUS WIRING FROM EXISTING DDC CONTROL PANEL

THERMOMETERS, AND NEW FLEXIBLE CONNECTORS TO SERVE NEW CHILLER.

CONTRACTOR SHALL INSTALL NEW ISOLATION (BUTTERFLY) VALVES, NEW PRESSURE GAUGES, NEW

WATER PIPING. SEE M-601 FOR SIZING AND CAPACITY DETAILS.

CONTRACTOR SHALL INSTALL NEW AIR-COOLED CHILLER (CH-1) AND RECONNECT IT TO EXISTING CHILLED-

DISPOSE OF USED REFRIGERANT PER SPECS.

CONTRACTOR SHALL DISPOSE OF ALL DEMOLISHED EQUIPMENT OFF-SITE AND9.

EXISTING ELECTRIC UTILITIES AND PIPE SIZES PRIOR TO ORDERING.

CONTRACTOR SHALL VERIFY THAT ALL NEW EQUIPMENT IS COMPATIBLE WITH8.

FOR INSTALLATION FOR THIS PROJECT.

AND SHALL BE ADJUSTED TO REFLECT NEW EQUIPMENT SUBMITTED AND APPROVED

DISCONNECTS, WIRES, AND CONDUIT, ARE SIZED FOR EXISTING EQUIPMENT ONLY

ALL EXISTING ELECTRICAL DEVICES, INCLUDING CIRCUIT BREAKERS, FUSES,7.

ALL NEW WIRING FOR EQUIPMENT SHALL BE COPPER.6.

WIRING, INSULATION, AND ALUMINUM JACKETING.

ALL EXTERIOR, ABOVE-GRADE CHILLED-WATER PIPING SHALL FEATURE HEAT-TRACE5.

EXECUTION PER SPECS.

CONTRACTOR SHALL REINSULATE ALL PIPING THAT IS DISTURBED BY WORK4.

NFPA 101 (LIFE SAFETY CODE).

STANDARD PLUMBING CODE, NFPA 13, NFPA 70 (NATIONAL ELECTRIC CODE), AND

INCLUDE, BUT ARE NOT LIMITED TO, INTERNATIONAL BUILDING CODE, NATIONAL

SPECIAL PROVISIONS, TERMS AND CONDITIONS. APPLICABLE CODES AND STANDARDS

MANUFACTURER�S SPECIFICATIONS AND RECOMMENDATIONS, AND ALL CONTRACT

LAWS AND REGULATIONS, INDUSTRY AND CONSTRUCTION CODES AND STANDARDS,

ALL WORK FOR THIS PROJECT SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL3.

DAY AND IMPLEMENT A PLAN TO PREVENT UNINTENDED ACCESS.

CONTRACTOR SHALL KEEP WORK AREA CLEAN AND ORGANIZED DURING THE WORK2.

EXECUTION.

CONTRACTOR SHALL FIELD VERIFY EXISTING SITE CONDITIONS PRIOR TO WORK1.

BE REUSED, HOWEVER, CONTRACTOR SHALL EXPAND IT IF IT IS UNDERSIZED.

NEW CHILLER SHALL BE PLACED ON A FORMED-AND-PLACED CONCRETE PAD PER SPECS. EXISTING PAD MAY

CONDUCTORS AND ONE #2 CONDUCTOR FOR GROUNDING.

BETWEEN MDP AND NEW CHILLER DISCONNECT. EACH OF THESE WIRES SHALL CONTAIN THREE #4/0, THWN

BE REUSED IF THEY ARE APPROPRIATELY SIZED. CONTRACTOR SHALL INSTALL TWO NEW WIRES IN PARALLEL

BUCKET-TYPE BREAKER IN EXISTING MAIN DISTRIBUTION PANEL (MDP) IN ROOM 125. EXISTING FUSES MAY

OVERCURRENT PROTECTION FOR NEW CHILLER SHALL BE PROVIDED BY 500 AMP FUSES IN EXISTING, NUMBER

REFERENCE

SHEET

Project No.

D e s ig n e d B y

D a te

M a rk

Bldg. No.

F T

H O

O D T

E X

A S

S A

N T

A F

E E

N G

IN

E E

R D

R

B

L D

G

F O

R T H

O O

D T

E X

A S

P U

B L

IC

W

O R

K S

D

IR

E C

T O

R A

T E

D a te

D e s c ri p ti o n sivi

D secivreS & gn ir ee ni g n

E

D ir ec to rat eofPublic

W o rk s

P R

O J E

C T M

A N

A G

E R

P U

R P

O S

E S O

N L

Y F

O R B

ID

D

IN

G T

E C

H N

IC

A L E

X H

IB

IT

B

/1

/2

:5

:1

P

M G E

N G

S

V C \E

N G

IN

E E

R

IN

G

P ro je c ts \1

P R

E P

L A

C E F

A

IL

E D A

IR

-C

O O

L E

D C

H

IL

L E

R B

L D

G

\F lo o rp la n s

D e s ig n \M

-1 .d g n

39009

13900986P

B P

R E

S S

E R

-A

P R -2

A

IR

-C

O O

L E

D C

H

IL

L E

R R

E P

L A

C E F

A

IL

E D

LANDING

CH-1

CHWP-1

CHS

CHR

MECHANICAL

OFFICE

C O

R R

ID

O R

CHEMO

CALL LNO

CONTROL PANEL

EXISTING DDC

NEW CHILLER

NEW FLOW SWITCH

EXISTING MDP

DISCONNECT

CONTROLS

EXISTING CHILLER

NEW CHILLER DISCONNECT

LEGEND:

EXISTING PIPING TO REMAIN

NEW PIPING

NEW ELECTRICAL DISCONNECT

EXISTING ELECTRICAL DISCONNECT

NEW THERMOMETER

NEW PRESSURE GAUGE

EXISTING BALANCING VALVE

NEW BUTTERFLY VALVE

BRIAN.E.PRESSER

Polygon

BRIAN.E.PRESSER

Polygon

BRIAN.E.PRESSER

Callout

REMOVED KEY NOTE SYMBOL

BRIAN.E.PRESSER

Callout

REMOVED KEY NOTE FOR ADJUSTING EXISTING BALANCING VALVE NEAR CHWP-1

M-601

B P

R E

S S

E R

M E

C H

A N

IC

A L S

C H

E D

U L E

SYMBOL

GPM

MINIMUM EER

55CH-1

(TONS)

CAPACITY

POWER SUPPLY

VOLTAGEPHASE

(HZ)

CYCLE

60 208/230345

(°F)

TEMPERATURE

LEAVING

(°F)

TEMPERATURE

ENTERING

CHILLED WATER

(°F)

TEMPERATURE

AIR

AMBIENT

95 4

AIR-COOLED CHILLER SCHEDULE

COMPRESSORS

NUMBER OF

MINIMUM

TYPE

REFRIGERANT

R410A 189 9.878.2

MINIMUM EER LISTED IS AT AHRI CONDITIONS.5.

UNIT SHALL FEATURE A SINGLE-POINT POWER CONNECTION.4.

UNIT SHALL FEATURE A WIRED, FACTORY-MOUNTED FLOW SWITCH.3.

UNIT SHALL FEATURE A STRAINER ON ITS SUCTION SIDE.3.

UNIT SHALL FEATURE HAIL GUARDS2.

UNIT SHALL FEATURE A LONWORKS INTERFACE CARD.1.

NOTES:

NUMBER

REFERENCE

SHEET

Project No.

D e s ig n e d B y

D a te

M a rk

Bldg. No.

F T

H O

O D T

E X

A S

S A

N T

A F

E E

N G

IN

E E

R D

R

B

L D

G

F O

R T H

O O

D T

E X

A S

P U

B L

IC

W

O R

K S

D

IR

E C

T O

R A

T E

D a te

D e s c ri p ti o n sivi

D secivreS & gn ir ee ni g n

E

D ir ec to rat eofPublic

W o rk s

P R

O J E

C T M

A N

A G

E R

P U

R P

O S

E S O

N L

Y F

O R B

ID

D

IN

G T

E C

H N

IC

A L E

X H

IB

IT

B

/1

/2

:5

:1

P

M G E

N G

S

V C \E

N G

IN

E E

R

IN

G

P ro je c ts \1

P R

E P

L A

C E F

A

IL

E D A

IR

-C

O O

L E

D C

H

IL

L E

R B

L D

G

\F lo o rp la n s

D e s ig n \M

-6 .d g n

39009

13900986P

B P

R E

S S

E R

-A

P R -2

A

IR

-C

O O

L E

D C

H

IL

L E

R R

E P

L A

C E F

A

IL

E D

G-101 Cover Sheet
D-101
M-101
M-601