7)_Drawing__FIRE.PDF
PDF 1 MB Posted
- Attached to
- Repair Building B127, CP Bonifas
- Solicitation number
- W90VN819R0038
About this file
Drawing 7. Fire Protection
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Submittal_Register.pdf | ||
| 2)_Drawing___ARCH.PDF | ||
| 1)_Drawing_files___Title.pdf | ||
| 4)_Drawing___ELEC.PDF | ||
| 5)_Drawing__MECH.PDF | ||
| 6)_Drawing__STRU.PDF | ||
| W90VN8-19-R-0038.pdf | ||
| 3)_Drawing___CIVIL.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
T A
K
Y S
C P B
O N
IF
A S
K O
R E
A
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
F E
W R
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
IN
G
A
P R
& SCOPE OF WORK,
FOR ABBREVIATION, LEGEND, GENERAL NOTES1.
NOTES
200010005000
SCALE: 1:50
1/50
SCALE :
REMOVAL FIRE ALARM SYSTEM PLAN
(WIRING), CONDUIT, JUNCTION BOXES AND ASSOCIATED
ALL EXISTING ELECTRICAL ITEM INCLUDING CIRCUITRY2.
R E
M O
V A
L F
IR
E A
L A
R M S
Y S
T E
M P
L A
N
FD101
ACCESSORY SHALL BE REMOVED UNLESS OTHERWISE
INDICATED ON THE DRAWING.
N
SEE SHEET NO. G-006, G-007, G-008 & E-001.
(S -1
D
W
D
W
D D D
FF F
D D
DDDD
D D
DD
REMOVE EXIST FIRE ALARM
DETECTOR W/SOUND BASE
REMOVE EXIST FIRE
ALARM MANUAL PULL
REMOVE EXIST FIRE ALARM
CONTROL PANEL
(TYPICAL)
REMOVE EXIST FIRE
ALARM BELL (TYPICAL)
STATION (TYPICAL)
1 2 3 4 5
A
B
C
D
ROOM
SLEEPING
ROOM
LIVING
ROOM
MECH
LAUNDRY
STORAGE
ROOM
COMM
VEST
VEST CORRIDOR
ROOM
LIVING
ROOM
SLEEPING
ROOM
LIVING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
LIVING
ROOM
LIVING
ROOM
SLEEPINGD
F
F/A
D
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
T A
K
Y S
1/50
SCALE :
NEW FIRE ALARM SYSTEM PLAN
FA101
N
SCALE: 1:50
0 500 1000 2000
NEW HEAT DETECTOR/ SENSOR
NEW HEAT DETECTOR/ SENSOR
NOTES
FOR ABBREVIATION, LEGEND, GENERAL NOTES
& SCOPE OF WORK,
SEE SHEET NO. G-006, G-007, G-008 & E-001.
1.
ALL SPEAKERS AND SOUNDER BASES IN ALL
SLEEPING ROOMS SHALL BE PROVIDED WITH
2.
A 520Hz TONE.
* ADDITIONAL LEGEND (THIS SHEET ONLY)
NEW MANUAL FIRE ALARM STATION,
MOUNTED 1,220 MM AFF TO TOP
- SPOT TYPE, CEILING MOUNTED
S P
SMOKE DETECTOR/ SENSOR
BASE WITH ADDRESSABLE INPUT MODULE
12/24VDC OPERATING VOLTAGE 85dB IN ALARM, LOCAL SOUNDER
NEW CARBON MONOXIDE DETECTOR, CEILING MOUNTED,
CO
NEW PHOTOELECTRIC SYSTEM
SB
- WITH SOUNDER BASE, CEILING MOUNTED
SMOKE DETECTOR/ SENSOR
NEW PHOTOELECTRIC SYSTEM
FE
FIRE EXTINGUISHER PANEL
(UNDER MECH ITEM) RELAY WITH ADDRESSABLE MODULER
J
W/ADDRESSABLE MODULE
J
XX
SEE SHEET NO. G-009, G-010, & G-011.
FOR ABBREVIATION, LEGEND, AND GENERAL NOTES1.
NOTES
CONTRACTOR SHALL COMPLETE DESIGN AND INSTALL
2.
THE SYSTEM FOR READY TO USE. THE NUMBER OF
DEVICES SHOWN IS THE MINIMUM REQUIRED AND THE
FINAL QUANTITY SHALL BE IN ACCORDANCE WITH THE
APPLICABLE CODE, SPECIFICATIONS AND
MANUFACTURER'S EQUIPMENT LISTING.
SHOP SUBMITTAL TO SHOW DETAILED INSTALLATION
DEVICE LOCATIONS IN ACCORDANCE WITH THE
MANUFACTURER'S LISTED INSTALLATION
REQUIREMENTS AND WIRE COUNT.
RESPONSIBLE FOR PROVIDING FIRE ALARM INTELLIGIBILITY/
THE FIRE ALARM SYSTEM CONTRACTOR SHALL BE 4.
AUDIBILITY CALCULATION, WIRE SIZE, CONDUIT SIZE,
NO. OF WIRES FOR THE FIRE ALARM AND DETECTION SYSTEM.
SHALL BE PROVIDED BY THE CONTRACTOR WHEN THE
THE VOLTAGE DROP AND POWER SUPPLY CALCULATION5.
CONTRACTOR SUBMITS SHOP DRAWINGS.
CIRCUIT AND ROOM LOCATION OF PANEL SHALL BE 6.
INDICATED ON THE FIRE ALARM PANEL COVER.
BUILDING TRANSMITTER AND ANTENNA.
COAXIAL CABLE SHALL BE ONE PIECE BETWEEN12.
OR FM APPROVED.
ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED7.
DEVICES ARE SHOWN IN SUGGESTED LOCATION. FINAL
DEVICE LOCATION AND CONDUIT ROUTING ARE CONCEPTUAL.3.
QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE WITH
APPLICABLE CODES, MANUFACTURER'S RECOMMENDATIONS,
AND EQUIPMENT LISTINGS. COORDINATE LOCATIONS WITH
LIGHTING AND MECHANICAL SYSTEM AND BUILDING
ARCHITECTURAL FEATURES.
ALL CONDUIT IN FINISHED AREAS SHALL BE CONCEALED.
ALL FIRE ALARM CONDUIT SHALL BE 21mm MINIMUM. 8.
SYNCHRONIZE ALL AUDIBLE NOTIFICATION APPLIANCES.
SYNCHRONIZE ALL VISUAL NOTIFICATION APPLIANCES.9.
PATTERN TONE FOLLOWED BY THE APPROPRIATE VOICE
THE FIRE ALARM SIGNAL SHALL BE A TEMPORAL THREE10.
MESSAGE.
FROM SUPPLY ARE DIFFUSERS.
SMOKE DETECTOR SHALL BE LOCATED A MINIMUM OF 900mm11.
DIGITAL VOICE MODULE, MICROPHONE, BATTERY, AND BATTERY
SEMI-FLUSH OR FLUSH MOUNTED ADDRESSABLE FIRE ALARM
PROGRAMMABLE MODULE & RELAYS, LCD ANNUNCIATOR,
SYNCHRONIZATION CONTROL MODULE, POWER SUPPLY,
CHARGER, POWER MODULES PANEL (AS REQ'D), NEMA 1 ENCL
24VDC, BUILT-IN ADDRESSABLE POINTS MODULES AS REQ'D,
MOUNTED 2032 MM AFF TO BOTTOM OF DEVICE
INDICATED ON THE DRAWINGS.
LENS WITH MARKINGS "FIRE", CANDELA RATING AS
WALL MOUNTED FIRE ALARM HORN/STROBE WITH CLEAR COLOR
NEW FIRE ALARM ANTENNA
TRANSMITTER COMPATIBLE WITH CENTRAL F/A RECEIVING
ALL FIRE ALARM TRANSCEIVER SHALL BE A MONACO BTX13.
SYSTEM.
FTR
FMCP
FMCP
CONTROL & MNS PANEL (FMCP),
D
W
D
W
CO
EOL
EOL
TYPE "D"
TYPE "C"
TYPE "B"
TYPE "E"
TYPE "A"
VEST-1
ROOM
COMM
STORAGE
MECH ROOM 110
LANUNDRY
VEST-2
CORRIDOR
ROOM
SLEEPING
LIVING
LIVING
ROOM
LIVING
ROOM
LIVING
ROOM
LIVING
F
EJ
F E J
F
EJ
F E J
F
EJ
CONN TO SHUNT-TRIP
TYPE CIRCUIT BREAKER
FOR ELEC RANGE
C
R J
C
R J
C
R J
CONN TO SHUNT-TRIP
TYPE CIRCUIT BREAKER
FOR ELEC RANGE
C
R
J
C
R
J
FTR
FMCP
(BT-XM)
NEW COMBINATION FIRE ALARM INTERFACE / TRANSMITTER
THE FIRE ALARM & MNS SYSTEM IS CONCEPTUAL. THE
C P B
O N
IF
A S
K O
R E
A
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
F E
W R
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
(S -1
N E
W F
IR
E A
L A
R M S
Y S
T E
M P
L A
N
A
P R
NUMBER
IDENTIFICATION
SHEET
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
T A
K
Y S
1 2 3 4 5
D
C
B
BUILDING TRANSMITTER LOCATION LAYOUT PLAN
24123
T
T
Dispensing Unit
: PROJECTED BUILDING
FA102
L A
Y O
U T P
L A
N
B U
IL
D
IN
G T
R A
N S
M
IT
T E
R L
O C
A T
IO
N
C P B
O N
IF
A S
K O
R E
A
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
F E
W R
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
A
P R
SHEET
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
J
U N
E
T A
K
Y S
D
C
B
1 2 3 4 5
BT-XM
BT-XM
BT-XM
BT-XM
BOQ
BEQ
BEQ
BEQ
NUMBER INSTALLATION BLDG NO.
REMARKSBUILDING USAGE
EXISTING
BUILDING TRANSMITTER BUILDING TRANSMITTER
NEW
BT2-4
BT-XM
BT-XM
BT-XMBOQ
BEQ
FL.
1.
3.
WITH CONNECTORS (TYPICAL)
W/ RAIN PROOF ENCL., COAXIAL CABLE (CLASS I&II)
ANTENNA AND MOUNTING SET, LIGHTNING ARRESTER
(BT-XM) WITH BATTERY & CHARGER, FIRE ALARM
DEVICES AND INSTALL NEW BUILDING TRANSMITTER
TRASMITTERS, ANTENNAS AND ASSOCIATED
CONTRACTOR SHALL REMOVE EXISTING BUILDING
ASSOCIATED DEVICES.
FIRE ALARM BUILDING TRANSMITTERS, ANTTENAS AND
FOR INSTALLAION DETAILS AND DIAGRAM, LOCATIONS OF
EXISTING SITE CONDITION AND PROVIDE SHOP DRAWING
CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY 2.
FIRE DEPARTMENT.
COMMUNICATED WITH RECIEVING SYSTEM IN BASE
BUILDING FIRE ALARM CONTROL SYSTEM TO BE
BE-RECONNECTED AND RE-CONFIGURED TO EXISTING
NEW FIRE ALARM BUILDING TRANSMITTER SHALL
4.
5.
NOTIFICATION SYSTEM FOR FUTURE USE
RELAY BOARDS(8EA) TO COMMUNICATE WITH MASS
NEW BUILDING TRANSMITTERS SHALL INCLUDE
6.
AND USING AGENCY.
BUILDINGS IF NECCESSARY BY THE DETERMINATION OF COR
BUILDINGS IN THE SCHEDULE CAN BE ALTERED WITH OTHER
CONDTION.
BUILDING TRANSMITTERS AND ANTTENAS TO MEET SITE
CONTROL PANELS TO NEW BUILDING FIRE ALARM
POWER/CONTROL WIRING FROM EXISTING FIRE ALARM
CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE
CAMP BONIFAS
CAMP BONIFAS
CAMP BONIFAS
CAMP BONIFAS
CAMP BONIFAS
CAMP BONIFAS
CAMP BONIFAS
BOQ
TOTAL 7 BUILDINGS
CONNECTED TO EXIST BT AT BUILDING S-128
CONNECTED TO EXIST BT AT BUILDING S-128
CONNECTED TO EXIST BT AT BUILDING S-128
BT2-4
CONNECTED TO EXIST BT AT BUILDING S-138
CONNECTED TO EXIST BT AT BUILDING S-164
FIRE ALARM BUILDING TRANSMITTER(BT) REPLACEMENT SCHEDULE
FA103
R E
P L
A C
E M
E N
T S
C H
E D
U L E
F
IR
E A
L A
R M B
U
IL
D
IN
G T
R A
N S
M
IT
T T
E R
C
B
O N
IF
A S
K O
R E
A
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
F E
W R
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
SHEET
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
J
U N
E
T A
K
Y S
D
C
B
1 2 3 4 5
GROUND CLAMP
21mm STEEL CONDUIT
MOUNTING BRACKET
21mm DIA BOLT (TYP)
FIN GRADE
CONNECTOR BOTH END
COAXIAL CABLE W/
25mmx25mmx3mm THK
HOT-DIPPED GALV.
ANGLE STEEL
RIGID STEEL
35mm DIA.
ANTENNA MAST
SERVICE HEAD
21mm DIA.
ANTENNA
OMNI DIRECTIONAL
915mm APART (MIN)
STRAP STEEL (TYP)
35mm DIA RSC
U-BOLT FOR
CONDUIT AS REQ'D
SEAL END OF
GND WIRE
#6 AWG "BC"
KIT, NEMA 3R ENCL
LIGHTNING ARRESTER
WEATHERPROOF SEAL
P
C
G
FA ANTENNA
OMNIDIRECTIONAL
KIT IN NEMA 3R ENCL
LIGHTNING ARRESTER
CABLE IN 21mm C
ANTENNA COAXIAL
IN 21mm C
1-#6 AWG (G)
S
EXIST SIGNALING LINE CIRCUIT
D
MEET WIRING REQUIREMENT FOR FACP OR MNS
POWER AND CONTROL LINES AS REQUIRED TO
EXIST FIRE ALARM DETECTOR (TYPICAL)
NOT TO SCALE
CONNECTION DIAGRAM
TYPICAL BUILDING TRANSMITTER
TRANSMITTER
TO FA BUILDING
FTR
(FACP)
CONTROL PANEL
EXIST FIRE ALARM
COR FOR LOCATION SELECTION.
SHALL COORDINATE WITH FIRE DEPARTMENT AND
BE NEXT TO EXIST "FACP" OR "MNS". CONTRACTOR
WITH BATTERY & CHARGER/ LOCATION SHALL
REPLACE WITH BUILDING TRANSMITTER (BT-XM)
NOTE
1.
2.
ATENNA, LIGHTNING ARRESTER, ETC BY BUILDING.
FOR INSTALLATION PLAN AND LOCATION OF BUILDING TRANSMITTER,
CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE SHOP DRAWING
LISTED BUILDINGS.
IF MASS NOTIFICATION SYSTEM IS NOT INSTALLED IN
SYSTEM OR ADDRESSABLE FIRE ALARM CONTROL PANEL
TRANSMITTER SHALL BE CONNECTED MASS NOTIFICATION
CONTROL LINES OF FIRE ALARM BUILDING
FIRE ALARM AND/ OR MASS NOTIFICATION SYSTEM POWER.
CONTRACTOR SHALL VERIFY EXISTING CONDITION OF
1-#6 AWG (G)
BUSHING
NOT TO SCALE
SEE SPECS
COPPER CLAD STL
GROUND ROD
FA ANTENNA MOUNTING DETAIL
(M
IN
ITEMS
WITH CONNECTORS
COAXIAL CABLE (CLASS I&II)
W/ RAIN PROOF ENCL.,
LIGHTNING ARRESTER
AND MOUNTING SET,
FIRE ALARM ANTENNA
WITH BATTERY & CHARGER,
TRANSMITTER (BT-XM)
7 SETS OF BUILDING
FA104
T R
A N
S M
IT
T E
R C
O N
N E
C T
IO
N D
IA
G R
A M
F A A
N T
E N
N A M
O U
N T
IN
G D
E T
A
IL
B
U
IL
D
IN
G
C P B
O N
IF
A S
K O
R E
A
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
F E
W R
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
| 175685FD101 |
| 175685FA101 |
| 175685FA102 |
| 175685FA103 |
| 175685FA104 |
File details come from the government source that posted it.