6)_Drawing__STRU.PDF
PDF 1 MB Posted
- Attached to
- Repair Building B127, CP Bonifas
- Solicitation number
- W90VN819R0038
About this file
Drawing 6. Structural
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Submittal_Register.pdf | ||
| 2)_Drawing___ARCH.PDF | ||
| 1)_Drawing_files___Title.pdf | ||
| 4)_Drawing___ELEC.PDF | ||
| 7)_Drawing__FIRE.PDF | ||
| 5)_Drawing__MECH.PDF | ||
| W90VN8-19-R-0038.pdf | ||
| 3)_Drawing___CIVIL.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
C H
O E S M
C A
M P B
O N
IF
A S
K O
R E
A
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
F E
W R
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
IN
G
A
P R
WALL
STIRRUP OR TIE
PRECAST CONCRETE COVER, REFER TO ACI-318 CHAPTER 7.
3. PROTECTIVE COVER SHOWN IS FOR CAST-IN-PLACE CONCRETE ONLY. FOR
2. THICKER PROTECTIVE COVER INDICATED IN SPECIFIC DETAILS SHALL GOVERN.
1. PROTECTIVE COVER SHOWN IS MINIMUM PERMITTED
75 CLR.
CONCRETE CAST
AGAINST EARTH
BEYOND
CONCRETE EXPOSED TO
EARTH OR WEATHER
NOTE
EXTERIOR
C L
R
MAIN OR TEMPERATURE
EARTH/CONC
BAR (TYP)
STIRRUP OR
TIE
EARTH
FACE
SURFACE
TEMPERATURE
BAR (TYP)
STIRRUP OR
MAIN OR
FORMED CONC
TIE
MAIN OR
BAR (TYP)
TEMPERATURE
BEAM
BARSMAIN BAR
CONCRETE NOT EXPOSED TO
EARTH OR WEATHER
COLUMN STIRRUP
40 CLR.
20 CLR
BEAM
20 CLR
MAIN
40 CLR
SLAB
JOINTS SHALL BE LOCATED AT THE MIDDLE 1/6 OF THE SLAB SPAN IN EITHER
Fy = 240 MPa
Fu = 400 MPa
Fu = 490 MPa
Fu = 1000 MPa
Fy = 240 MPa fy = 400 MPa fy = 448 MPa
2. METAL YIELD STRENGTHS (Fy) OR TENSILE STRENGTHS (Fu) :
f'c = 30 MPa
- MACHINE/ANCHOR BOLTS
- HIGH STRENGTH BOLTS (F10T OR A325)
- WELDING ELECTRODES (E70xx)
- WELDED WIRE FABRIC
- SLAB ON GRADE, MECH PAD
C. MATERIAL STRENGTHS :
- STANDING SEAM ROOFING (MIN)
- REINFORCING BARS (SD40 OR GRADE 60)
- STRUCTURAL STEEL (SS400 OR A36)
1220 mm
960 Pa
960 Pa
V = 59.4 m/sec (USD)
CLASS D
S1=0.07g, Ss=0.16g
100 kPa
TO CLEAN AND ROUGH STANDARDS.
DIRECTION. ALL REINFORCING BARS SHALL BE CONTINUOUS THROUGH CONSTRUCTION
JOINTS AND CONCRETE JOINT FACES SHALL BE KEYED OR INTENTIONALLY ROUGHENED
- BASIC WIND SPEED (RISK CATEGORY II)
- EXPOSURE CATEGORY
- WIND PRESSURE
- MINIMUM DESIGN BEARING CAPACITY
- IMPORTANCE FACTOR
- FROST DEPTH
B. FOUNDATIONS :
1. DESIGN PARAMETERS
- SEISMICITY
- SOIL TYPE
4. SEISMIC (UFC 3-301-01)
- RISK CATEGORY
C
DESIGN DATA
A. DESIGN LOADS :
2. FLOOR LIVE
3. WIND (UFC 3-301-01/IBC)
- GROUND SNOW
- LIVE
1. ROOF
AND SHALL BE MODIFIED TO SUIT THE SELECTED EQUIPMENT.
PERIMETER FELT JOINTS. UNDER NO CIRCUMSTANCES SHALL SUCH JOINTS BE
D. CONSTRUCTION JOINTS ARE PERMITTED IN STRUCTURAL SLABS ON GRADE IF REQUIRED
BY CONCRETE PLACEMENT AND FINISHING LIMITATIONS. WHEN REQUIRED, CONSTRUCTION
CLEAN AND ROUGH JOINT SHALL REFER TO A CONCRETE TO CONCRETE CONTACT
SURFACE WHICH IS CLEAN AND FREE OF LAITANCE AND INTENTIONALLY ROUGHENED
1. DIMENSIONS, LOCATIONS, AND SIZES OF EQUIPMENT SUPPORTS, PADS, AND ROOF
OR WALL OPENINGS SHOWN ON THESE DRAWINGS ARE FOR INFORMATION ONLY
2. ANCHOR BOLTS SHALL BE SIZED AND LOCATED AS REQUIRED BY THE EQUIPMENT
A MINIMUM DISTANCE OF 150mm SHALL BE MAINTAINED FROM CENTER OF ANCHOR
3. SEE MECHANICAL DRAWINGS FOR ADDITIONAL PIPES, RISERS, VENTS, AND DUCTS
4. CONCRETE PLACED OVER PIPING SHALL BE POURED ONLY AFTER THE PIPING HAS
C. STRUCTURAL SLABS DO NOT REQUIRE CONTRACTION JOINTS, EXPANSIONS JOINTS, OR
TO AN AMPLITUDE OF 6mm (MINIMUM). JOINT SHALL BE CLEANED WITH WATER BLAST
MANUFACTURER'S SHOP DRAWINGS.
BOLT TO EDGE OF EQUIPMENT PAD.
WHICH PENETRATE THE ROOF, FLOOR OR WALL.
BEEN INSPECTED, TESTED AND APPROVED.
PERMITTED IN STRUCTURAL SLABS ON GRADE.
B. MECHANICAL EQUIPMENT
GENERAL NOTES
A. CONCRETE CLEAN AND ROUGH JOINT(CRJ)
CHIPPING HAMMER, OR OTHER SUITABLE MEANS.
1. CONCRETE MINIMUM COMPRESSIVE STRENGTH (f'c) :
M
IN
SLEEVE
M
IN
SLEEVE
BEAM
MINMIN
SECTION "A-A"
SLEEVE
"A"
GRADE BEAM
FOOTING OR
STEM WALL
"A"
PARALLEL PIPE PERPENDICULAR PIPE
M
IN
MIN
BELOW THIS PLANE
EMBEDMENT PERMITTED
NO PIPE OR CONDUIT
FOOTING OR GRADE
NOT TO SCALE
STANDARD HOOK FOR MAIN BARS, STIRRUPS & TIES
NOT TO SCALE
WALL INTERSECTIONS
NOT TO SCALE
CONCRETE PROTECTION FOR REINF BARS
NOT TO SCALE
PIPE OR CONDUIT AT FOUNDATION - DESIGN CATAGORY B
NOTE : SEE PLUMBING DRAWINGS
FOR SLEEVE DETAIL
STANDING SEAM METAL ROOFINGSSMR
RIM JOISTRJ
EAVE STRUTES
BOPC BOTTOM OF PILE CAP
CONC CONCRETE
CONSTRUCTION JOINTCNJ
CONTINUOUS OR CONTINUECONN
CWB CAPILLARY WATER BARRIER
HIGH STRENGTH BOLT
IJ ISOLATION JOINT
DET DETAIL
DIAMETERDIA
DIM DIMENSION
DN DOWN
DWG DRAWING
DWGS DRAWINGS
EACH FACEEF
EACHEA
EL ELEVATION
EQUIP EQUIPMENT
EW EACH WAY
EJ EXPANSION JOINT
EXP JT EXPANSION JOINT
EXST EXISTING
FL FLOOR
FNSH FINISH
FOOTFT
HGT HEIGHT
GRADE BEAMGB
GALVANIZEDGALV
HORIZ HORIZONTAL
HSB
JOINTJT
ELEC ELECTRICAL
EQ EQUAL
INDICATOR PILEIP
WWF
VARIABLEVAR
WITHW/
VERT VERTICAL
TRANSVERSALTRANS
TYP TYPICAL
THICKENED SLABTS
TOC TOP OF CONCRETE
THROUGHTHRU
TOP BART BAR
THK THICKNESS
BOTTOM BARB BAR
BOTTOM MOST BARBM BAR
STRUCTURALSTRL
STL STEEL
STD STANDARD
SQ SQUARE
SPEC(S) SPECIFICATION(S)
SIMILARSIM
SCHEDULESCHED
STRUC STRUCTURAL
RO ROUGH OPENING
ROOMRM
RFG ROOFING
REQUIREDREQD
REPL REPLACE OR REPLACEMENT
REINFORCED OR REINFORCEMENTREINF
RC REINFORCED CONCRETE
RADIUSRAD
PROJECTPROJ
PANELPNL
PC PILE CAP
PEDESTALPED
PEJ PRE-MOLDED EXPANSION JOINT
OPPOSITEOPP
OPNG OPENING
ON CENTEROC
NTS NOT TO SCALE
LONGITUDINALLONGIT
NUMBERNO
NOT IN CONTRACTNIC
NON FROST SUSCEPTIBLE MATERIALNFSM
NA NOT APPLICABLE
MISCELLANEOUSMISC
MIN MINIMUM
MANUFACTUREMFR
MEZZANINEMEZZ
MACHINE BOLTMB
METALMET
MECH MECHANICAL
MIDDLEMID
MAX MAXIMUM
MATERIALMATL
MAINT MAINTENANCE
LG LENGTH
COLUMNCOL
CONCRETE MASONRY UNITCMU
CLEARANCECLR
CRACK CONTROL JOINTCLJ
CJ CONTROL JOINT
CENTER LINECL
BOT BOTTOM
BEAMBM
BKS BARRACKS
BLDG BUILDING
ARCHITECTURALARCH
ANCHOR BOLTAB
WELDED WIRE FABRIC
AUTOMATIC WELDING STUDAWS
ABBREVIATIONS
QTY QUANTITY
FOR
BAR CLEAR COVER
TEE INTERSECTION
FOR
CORNER
STANDARD HOOKS
STANDARD HOOK
MAIN BAR
ADDED VERT BARS
WALL HORIZ BARS
WALL VERT BARS
SEE SEE
SIZE
BAR
H d
DdD D
DIMENSION
DETAILING
D E
T A
IL
IN
G
D
IM
E N
S
IO
N
D E
T A
IL
IN
G
D
IM
E N
S
IO
N
DETAILING
d
A or G
D (mm)SIZE
BAR
140HD22
HD13
HD19
HD16
HD10
(mm)
HOOKS
(mm) A or G
STIRRUP & TIE HOOKS
D=4d FOR HD10 ~ HD16 BARS
D=6d FOR HD10 ~ HD25 BARS
D=8d FOR HD29, HD32 BARS
MAIN BAR HOOKS
HD19
HD22
HD16
HD13
HD29
HD32
HD25
A
B
(mm)
HD16
HD10
HD13
D
D=6d FOR HD19, HD22 BARS
SEISMIC STIRRUP/TIE HOOKS
D=4d FOR HD10 ~ HD16 BARS
APPROX.
A or G (mm)
H(mm)
C
L BEAM
(mm)
DIMENSION
SIZE
HD10
D J
A or G
(mm)
BAR
D
(mm) J d
L BEAM
A or G (mm)
HOOKS
c dD
D c
6d
H d
D E
T A
IL
IN
G
D
IM
E N
S
IO
N
M
IN
APPROX.
H(mm)
1 2
3 4
SF001
SF001
IBC TABLE 1609.6.2.1(1) & (4)
Fy = 240 MPa - COLD-FORMED STEEL SHAPES f'c = 24 MPa - ALL CONCRETE UNLESS NOTED OTHERWISE
7,200 Pa - MECHANICAL ROOM/COMM. ROOM
40 CLR
40 CLR
20 CLR 20 CLR
230230
M A X .(6 d ,7 m m
A o r
MAX.(4d,60mm)
A or G
A d
A or G
A
SF001
T
Y P
IC
A L D
E T
A
IL
S
G E
N E
R A
L N
O T
E S
D E
S
IG
N D
A T
A
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
C H
O E S M
C A
M P B
O N
IF
A S
K O
R E
A
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
F E
W R
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
A
P R
A
2 3 4 5
B
C
D
N
A
2 3 4 5
B
C
D
N
S L
O P
E S
L O
P E
REMOVE EXISTING
METAL ROOFING
S L
O P
E
REMAIN EXISTING
LOW ROOF PURLIN(TYP.)
E -S
B
E -S
B
E -S
B
E -S
B
LEGEND
E-SB1 : REMAIN EXISTING STEEL BEAM
R-P1
R-P1
R-P1
E-P1
E-P1
E-P1 : REMAIN EXISTING PURLIN
REMOVE EXISTING
ROOF PURLIN
R-P1 : REMOVE EXISTING PURLIN
NOTE 2
*NOTE
2. EXISTING LOW ROOF PURLIN SPACES AND ROOF SLOPE ARE BY EYE MEASURE.
EXISTING LOW
ROOF
EXISTING HIGH
ROOF
3. EXISTING HIGH ROOF FRAMES ARE ASSUMED THAT CONSIST OF WOOD OR
LIGHT WEIGHT STEEL, REMOVAL WORK SHOULD BE PROCEEDED NOT TO DAMAGE
NOTE 3
REMOVE EXISTING
HIGH ROOF FRAME
EXISTING LOW ROOF BEAMS AND PURLINS.
E -S
B
2337 6909 15334
24580
E-P1
E-P1
E-P1
E-P1
E-P1
E-P1
E-P1
E-P1
2337 6909 15334
24580
300 6075 300
SCOPE OF WORK
2 SAW CUT EXISTING CMU WALL
REPLACE CONC STOOP
REPAIR AND MAINTENANCE WORK
REPLACE EXISTING CONC SLAB W/ NEW 150THK CONC SLAB
BLOCK-UP EXISTING OPENING W/ CMU
5 REPLACE EXISTING HIGH ROOF W/ NEW
2 2
EXISTING GROUND FLOOR PLAN
SCALE: 1/100
EXISTING ROOF FRAMING PLAN
SCALE: 1/100
E-SC1 : REMAIN EXISTING STEEL COLUMN
E-SC1 E-SC1 E-SC1 E-SC1 E-SC1
E-SC1 E-SC1 E-SC1 E-SC1 E-SC1
1. EXISTING MAIN FRAME(PEB) SIZES COULDN'T CHECK CLEARLY BECAUSE THIS BUILDING
IS USING NOW, CONTRACTOR MUST HAVE CHECKED EXISTING MAIN FRAME FOR SUPPORTING
COLUMN OF NEW HIGH ROOF.
5915 6075 5915
SF101
SCALE: 1:100
0 1000 2000 4000mm
R
O O
F F
R A
M
IN
G P
L A
N S
E X
IS
T
IN
G /R
E M
O V
A L G
R O
U N
D F
L O
O R
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
C H
O E S M
C A
M P B
O N
IF
A S
K O
R E
A
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
F E
W R
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
A
P R
A
2 3 4 5
B
C
D
N
A
2 3 4 5
B
C
D
N
S L
O P
E S
L O
P E
S L
O P
E
REMAIN EXISTING
LOW ROOF PURLIN
E -S
B
NEW HIGH
ROOF
EXISTING LOW
ROOF
LEGEND
N-SB1 : H-125x125x6.5x9 STEEL BEAM
N-SC1 : 101.6 DIAx5t STEEL COLUMN
N-P1 : C-200x80x7.5x11 PURLIN
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-P1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
E-P1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1 N-SC1
N-SC1
N-SC1
N -S
B
N -S
B
N -S
B
N -S
B
E -S
B
P
E R
P
E R
15334
24580
N -S
B
N -S
B
LEGEND
NEW 150THK CONC SLAB
EXISTING 200 THK CMU WALL
MECH PAD
SCOPE OF WORK
2 SAW CUT EXISTING CMU WALL
REPLACE CONC STOOP
REPAIR AND MAINTENANCE WORK
REPLACE EXISTING CONC SLAB W/ NEW 150THK CONC SLAB
BLOCK-UP EXISTING OPENING W/ CMU
5 REPLACE EXISTING HIGH ROOF W/ NEW
FORM DECK PL(U.N.O.)
24580
NEW GROUND FLOOR PLAN
SCALE: 1/100
NEW ROOF FRAMING PLAN
SCALE: 1/100
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
N-SC1
E-P1
E-P1
E-P1
E-P1
E-P1
E-P1
E-P1
E-P1
E-P1
E-SC1 E-SC1 E-SC1 E-SC1 E-SC1
E-SC1 E-SC1 E-SC1 E-SC1 E-SC1
150THK CONC SLAB ON
GRADE
PAD
PAD
SF401
SF401
SF401
SF401
* SECTION PROPERTY :
1.2thk
Sx=17.5cm /M
Ix=60.5 cm /M
204.7146
10639.6
58.6
INSULATION & METAL SCREW
SSMR (SEE ARCH DWG FOR DETAIL)
(SEE ARCH DWG FOR DETAIL)
1441.3
2 AREA
LOADING DIAGRAMS/TABLES _BASED ON ASD
PRESSURE ACTING
AWAY FROM SURFACES
PRESSURE ACTING
(UNIT :N/M^2)
(UNIT :N/M^2)
TOWARD
DIRECTION
PRESSURE
948.2
1 AREA
AREA
"a" DISTANCE= 0.9M
3 AREA
1883.3( ) ( )
WIND FORCE FOR COMPONENTS & CLADING
a a a a
AT HATCHING AREA
SHALL BE 750mm
MAXIMUM PURLIN SPACING
a
CONC STOOP
SEE FOR DET.
SF501
MECH PAD
SEE FOR DET.
SF501
SEE FOR DET.
SF501
2337 6909
5915 6075 6075 5915300
5915 6075 6075 5915300 300
2 3 3
1 2 2
3 2 3 3
1 2
SF102SCALE: 1:100
0 1000 2000 4000mm
R
O O
F F
R A
M
IN
G P
L A
N S
N E
W G
R O
U N
D F
L O
O R
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
C H
O E S M
C A
M P B
O N
IF
A S
K O
R E
A
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
F E
W R
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
A
P R
D A
D A
F O
R M D
E C
K
H -1 x x .5 x
N -S
B
L O
W R
O O
F F
R A
M E B
Y P
E B
E -S
B
N -S
C
N -S
C
N -S
C
N -S
C
N -S
C
N -S
C 1 E
X
IS
T
IN
G
C M
U W
A L L
E X
IS
T
IN
G
S T
E E
L C
O L
U M
N B
Y P
E B
E X
IS
T
IN
G
C O
N C S
L A
B
F O
R M D
E C
K
H -1 x x .5 x
N -S
B
L O
W R
O O
F F
R A
M E B
Y P
E B
E -S
B
N -S
C
N -S
C
N -S
C
N -S
C
N -S
C
E X
IS
T
IN
G
C M
U W
A L L
E X
IS
T
IN
G
S T
E E
L C
O L
U M
N B
Y P
E B
E X
IS
T
IN
G
C M
U W
A L L
E X
IS
T
IN
G
C O
N C S
L A
B
S C
A L E
B U
IL
D
IN
G C
R O
S S S
E C
T
IO
N
/3
S
F
S C
A L E
B U
IL
D
IN
G C
R O
S S S
E C
T
IO
N
/3
S
F
E X
IS
T
IN
G P
U R
L
IN
E X
IS
T
IN
G
E X
IS
T
IN
G P
U R
L
IN
E X
IS
T
IN
G
L -2 x x .5 x
P U
R L
IN
B C
B C
E X
IS
T
IN
G
C M
U W
A L L
E X
IS
T
IN
G
C M
U W
A L L
E X
IS
T
IN
G
C O
N C S
L A
B
E X
IS
T
IN
G
C M
U W
A L L
E X
IS
T
IN
G
C M
U W
A L L
T
H K C
O N
C S
L A
B O
N
O V
E R
T
H K C
W B
O V
E R V
A P
O R B
A R
R
IE
R
-1 x W
W F
G R
A D
E W
M W
N F S
MS
T
O O
P
S T
O O
P
N F S
M
F O
R M D
E C
K L -2 x x .5 x
P U
R L
IN
S F
T
Y P
S F
T
Y P
SF401
S C
A L E
:3 m m
B U
IL
D
IN
G C
R O
S S S
E C
T
IO
N S
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
C H
O E S M
C A
M P B
O N
IF
A S
K O
R E
A
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
F E
W R
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
A
P R
L
D
GRUOT
(NOTE1)
SOLID
T-BAR
B-BAR
DSTIRRUP
B-BARS
OPENING
CLR40
T-BARS
PRECAST CONCRETE
LINTEL
STIRRUP
MORTAR
EXST CMU
WALL
200 200
NOTE2
A
A
@MECH.
RM
150x150 WWF
SEE PLAN
HD13
FNSH FL.
NFSM.
40CLR
W/ SEALANT
MW10(#8)-
10 PEJ
SCALE:
CONTRACTION JOINT(CRJ)
NTS
NOT TO SCALE
CMU BLOCK-UP DETAIL
800 O.C.(MAX)
HD13 HORIZ BARS
1. 150mm DEEP HOLE W/EPOXY
MORTAR @ GROUTED CELLS.
2. BREAK OUT BLOCK WEB &
GROUT SOLID WHERE GROUTED
PAPER FILLER @ CASE 2
CELLS DO NOT OCCUR
EXST CMU SOLID GROUT
IN-FILL
HD13 BAR
OPENING
@800 O.C. ON
LIMIT OF EXST
MORTAR
150mm DEEP HOLE W/EPOXY
EXISTING CONC STEM@ DOOR
CMU WALL OPENING DETAIL @EXISTING WALL
NOT TO SCALE
SECTION A-AELEVATION
SCALE:
CONC STOOP DETAIL
1/20
SF102
SCALE: 1/20
SF102
PAD DETAIL
SEE PLAN
0 1
APRON
@400 O.C. OIL OR
GREASE 1-END
20DIAx400 DOWEL
POURED JOINT
SEALANT W/
SEPARATING TAPE
LAP
BEAM
EXISTING GRADE
150THK CWB
W/ SEALANT
AT ALL EDGES
20mm CHAMFER
10THK
PERIMETER
FELT JOINT
150MIN.
C L
R
SIZE & LOCATION
CHEMICAL ANCHOR BOLT
AS REQ'D BY EQUIPMENT
150MIN.
@300 O.C. E.W. & E.F.
HD13
LINTEL SCHEDULE
D (MIN)MARK
L1 200
B-BARS
L (MAX) T-BARS
2-HD13
STIRRUPS
HD10@150 O.C.
L2 200 2100 2-HD16 HD10@150 O.C.
2-HD13
2-HD16
1. AFTER CUTTING OPENING, GROUT JAMBS
SOLID TO GREATEST EXTENT POSSIBLE
OR LOUVER FRAME
2. DIMENSION AS REQUIRED FOR DOORS, WINDOW,
NOTES:
3. SEE ARCH PLAN FOR DOOR SIZE AND LOCATION
SCALE: 1/10
SF401
DETAIL
SCALE: 1/10
SF102
DETAIL
3-SIDES
9THK STIFFNER
150x150x6t
BASE PLATE
101.6DIAx5t
STEEL COLUMN
EXISTING STEEL
BEAM
H-125x125x6.5x9
N-SB1
3-SIDES
6THK STIFFNER
PURLIN
L-200x80x7.5x11
W/ 2-M12 MB
L-150x90x9
(BOTH SIDES)
V A
R
IE
S
SF501
SCALE: 1:10
100 200 400mm
SCALE: 1:20
200 400 800mm
M
IS
C
D E
T A
IL
S
| 1 |
| 2 |
| 3 |
| 4 |
| 5 |
File details come from the government source that posted it.