1)_Drawing_files___Title.pdf
PDF 4 MB Posted
- Attached to
- Repair Building B127, CP Bonifas
- Solicitation number
- W90VN819R0038
About this file
Drawing 1. Title
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Submittal_Register.pdf | ||
| 2)_Drawing___ARCH.PDF | ||
| 4)_Drawing___ELEC.PDF | ||
| 7)_Drawing__FIRE.PDF | ||
| 5)_Drawing__MECH.PDF | ||
| 6)_Drawing__STRU.PDF | ||
| W90VN8-19-R-0038.pdf | ||
| 3)_Drawing___CIVIL.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 G-001 TITLE SHEET, SCHEDULE OF DRAWINGS & CROSS
REFERENCING CONVENTIONS
2 G-002 PROJECT LOCATION PLAN
CIVIL
GENERAL
AE001 GENERAL NOTES & SCOPE OF WORK
ARCHITECTURAL
AE201 ELEVATIONS & CROSS SECTIONS
AE401
EXTERIOR WALL SECTIONS & INTERIOR ELEVATION
AE101
AE102
EXISTING/REMOVAL FLOOR PLAN
NEW FLOOR & ROOF PLANS
CAMP BONIFAS, KOREA
ELECTRICAL
E-001
ED101
SCOPE OF WORK
REMOVAL/EXIST ELECTRICAL PLAN
NEW LIGHTING PLAN EL101
NON-STANDARD LIGHT FIXTURE DETAILS EL501
EL601 LIGHT FIXTURE SCHEDULE
NEW/EXIST ELECTRICAL PLAN
BLDG #127
G-003 ABBREVIATIONS, NOTES, LEGEND & SCOPE OF WORK 3
G-0044 ABBREVIATION, MATERIAL INDICATIONS & SYMBOLS
(ARCHITECTURAL)
G-0055 LEGEND & ABBREVIATION
(MECHANICAL)
G-0066 LEGEND AND ABBREVIATIONS
(ELECTRICAL)
G-0077 GENERAL NOTES-1
(ELECTRICAL)
(CIVIL)
G-0088 GENERAL NOTES-2
(ELECTRICAL)
EP101
AE601 EXTERIOR/ INTERIOR FINISH SCHEDULE & MATERIAL/ COLOR SCHEDULE
AE602 SIGNAGE NUMBERING PLAN, SCHEDULE, TYPE & DETAIL
AE603
AE103 REFLECTED CEILING PLAN
& DOOR HARDWARE SCHEDULE
DOOR/ LOUVER NUMBERING PLAN, SCHEDULE, TYPE
SF001 GENERAL NOTES, DESIGN DATA & TYPICAL DETAILS
STRUCTURAL
SF101
SF102
EXISTING/REMOVAL GROUND FLOOR & ROOF FRAMING PLANS
NEW GROUND FLOOR & ROOF FRAMING PLANS
SF401 BUILDING CROSS SECTIONS
CD1019 REMOVAL PLAN
SITE LAYOUT PLANCS10110
C-501
MISC DETAILS
DRAINAGE PLANCG101
DRAIN LINE PROFILECG201
MECHANICAL
MH001
MD101
GENERAL NOTES & SCOPE OF WORK
EXISTING / REMOVAL HVAC PLAN
MH601 MECHANICAL EQUIPMENT SCHEDULE-1
MH602
PD101
HVAC SYSTEM CONTROL DIAGRAM-1
EXISTING / REMOVAL PLUMBING PIPING PLAN
MH101 NEW HVAC DUCT PLAN
PP101 NEW PLUMBING PIPING PLAN-1 (DCW & DHW PIPING)
PP601 PLUMBING EQUIPMENT SCHEDULE
MH603
HVAC SYSTEM CONTROL DIAGRAM-2
PP602 PLUMBING SYSTEM CONTROL DIAGRAM
MECHANICAL EQUIPMENT SCHEDULE-2
MH604
MH102 NEW HVAC PIPING PLAN
HVAC SYSTEM CONTROL DIAGRAM-3MH605
S C H E D U L E O F D R A W I N G S SECTION / DETAILS CROSS
REFERENCING CONVENTIONSDESCRIPTION OF DRAWINGS REVISION STATUS DESCRIPTION OF DRAWINGSSHEET
NO. REVISION STATUS
SHEET
IDENTIFICATION
NO.
SHEET
IDENTIFICATION
NO.
SUBTITLE FOR DETAIL DRAWING
SUBTITLE FOR SECTION DRAWING
SYMBOL WHERE SECTION IS TAKEN
SYMBOL FOR LOCATING CONDITION FOR
CALLED OUT SHEET NUMBER
SECTION IDENTIFICATION NUMBER
DETAIL
WHICH THERE IS A DETAIL
SECTION
DETAIL IDENTIFICATION
NUMBER
CALLED OUT SHEET NUMBER
SHEET
NO.
DWG CODE DWG CODE
Chief, Engineering DivisionChief, Technical Review Branch
Project Manager
Date
Date
Approved By:
Date
Approved By:
Submitted By:
T
IT
L E S
H E
E T S
C H
E D
U L E O
F D
R A
W
IN
G S
G-001
C R
O S
S R
E F
E R
E N
C
IN
G C
O N
V E
N T
IO
N S
LOAD SCHEDULES AND CONN. DIAGRAM EP601
FIRE PROTECTION
FD101
FA101
REMOVAL FIRE ALARM SYSTEM PLAN
NEW FIRE ALARM SYSTEM PLAN
SF501 MISC. DETAILS
PP102 NEW PLUMBING PIPING PLAN-2 (VENT & SEWER PIPING)
AE002 LIFE SAFETY PLAN 53
FA102
FA103
54 FA104
BUILDING TRANSMITTER LOCATION LAYOUT PLAN
FIRE ALARM BUILDING TRANSMITTER(BT) REPLACEMENT SCHEDULE
FA ANTENNA MOUNTING DETAIL & BUILDING TRANSMITTER CONNECTION DIAGRAM
TRANSCEIVERS AND REPAIR S-127,
FEWR # 138581 REPLACE BUILDING
D
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
Y I, S
C
C P B
O N
IF
A S
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
IN
G
K
O R
E A
F E
W R
A
P R
D
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
Y I, S
C
C P B
O N
IF
A S
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
O R
E A
F E
W
A
P R
S
C
WP
CP
CP
CP CP
CP
CP
CP
CP
CP
CP
OWS
OWS
A.C.
S-0024
SO
SO SO
LP
LP
LP
LP
A/G
OIL
TANK
A.C.
A.C.
A/G
OILTANK
WP
BREAK AREA
BREAK AREA
WP
A.C PAVED ROAD
A.C PAVED ROAD
G R
IL
L
B A
R B
E C
U E
S -1
S-152
S -1
S-
S -1
S -1
S -1
S-1
S-149
GATE
T-157
S-172
S-122
S-100
S-
S -1
GATE
T-123
S-
S -1
S-1
S-
S-142
S -1
G A
T E
S-153
S-
S-
T-
T -2
S -8
S -9
T -5
B U
N K
E R
F /T
SHED
T R
A S
H G
U A
R D
F /T
BUNKER
B U
N K
E R
B U
N K
E R
U/G
G U
A R
D
B U
N K
E R
TRASH
U /G
F A
N
S H
E D
B U
N K
E R
SHED
SHED
SHED
SHED
T-39
TRASH
F /T
F /T
F/T
F/T
U/G
F/ T
F/ T
F /T
F /T
F /T
F/T
F/T
F/T
F/T
F/T
F /T
F/T
F /T
F/T F/T
FAN
T R
A S
H
F A
N
T -1
T -6
S -1
S -1
T-1
T -1
T-1
T-20
T-21
T -3
SHED
S-126
T -6
T-
S -8
S-99
S-98
S-97
T -3
T-62
B A
N K
T -2
B
U N
K E R
S H E
D
S H E D
S -1
S H E
D
GEN
S-159
SHED
SHED
P O
R T
A
SHED
SHED
S H
E D
T R
A S
H
S-
S-
T-
W A
R E H
O U
S E
S H
E D
SH
ED
S H
E D
S H
E D
S H E
D
SHED
FAN
TRASH
F /T
F /T
G R E E N
S A
N D
S A
N D
S A N
D
B U
N K E R
B U
N K E R
B U
N K E
R
BUNKER
BUNKER
B U
N K E R
U /G
U /G
F A
N
SHED
TRANS
GUARD
B U
N K
E R
B U
N K
E R
BUNKER
B U
N K
E R
FAN
FAN
TCL BOX
S H
E D
F A
N
U /G
TRASH
CHAI
R
CHAI
R
CHAI
R
CHAI
R
CHAI
R
C H
A
IR
C H
A
IR
C H
A
IR
C H
A
IR
C H
A
IR
C H
A
IR
C H
A
IR
C H
A
IR
C H
A
IR
C H
AIR
C H
A
IR
C H
A
IR
C H
A
IR
C H
A
IR
WALL
W O
O D E
N W
A L L
W O
O D E
N W
A L L
F
IR
IN
G R
A N
G E
F
IR
IN
G R
A N
G E
G A
T E
GATE
GATE
TR
A S H
SW
IM
MI
NG
POOL
WATER TANK
F A
N
G U
A R
D
F A
N
A/C
PAVED R
OAD
A/ C P
AVED
R
O
AD
D M
U
A T
M
CONTRACTING OFFICER DURING THE SITE ORIENTATION.
OPERATION AREA WILL BE DESIGNATED BY
THE CONTRACTOR'S HAUL ROUTE, STORAGE AND
NOTE:
40m20100
SCALE: 1:1,000
N
ACCESS CONTROL POINT
WONJU
POHANG
15 50
MOKPO
TONGYEONG
SEOUL
DONGDUCHEON
UIJEONGBU
CHUNCHEON
1OSAN
DAEJEON
E A S T S E A
BUSAN
WAEGWAN
JINHAE
DAEGU
MUNSAN
W E S T
S E A
INCHEON
GWANGJU
NOT TO SCALE
L O C A T I O N M A P
GUNSAN
PYEONGTAEK
YEONGPYEONG
N
BONIFAS
PROJECT LOCATION PLAN
SCALE: 1:1,000
THIS PROJECT
S-127
S-178
G-002
P R
O J E
C T L
O C
A T
IO
N P
L A
N
S-127, CP BONIFAS, KOREA
TRANSCEIVER WITH NEW INCLUDING REPAIR
FEWR # 138581 REPLACE FIRE ALARM BUILDING
D
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
Y I, S
C
C P B
O N
IF
A S
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
O R
E A
F E
W
A
P R
C I V I L A B B R E V I A T I O N S
C I V I L L E G E N D
PORTLAND CEMENT CONCRETE
CRM
BOT,B
CMS
CLR
CONSTR
CW
CV
CTRJ
C TO C
CTG
CRV
CP
CORR
COR
CONT
CONN
CONC
COL
CMU
CMP
CLKG
CLJ
CL OR C
CJ
CI-CIP
CHAN
CAP
C
BS
BRK
ACM
BO
BLK
BLDG(S)
BKS
BH
BCE
BARR
AVG
AUTO
AT/FP
ASPH
ASAP
ARCH
APPROX(.)
ALT
AL
AKR
A/G
ADJ
ADH
ADD
AD
ACS
ACP
ACCU
AC
AB
MATERIALMAT(')L
PROPERTY (MATERIAL)
HEXAGON
HARDWARE
HOSE BIBB
HIGH, HEAD, HORIZONTAL
GALVANIZED
GREASE TRAP
GATE VALVE
GALVANIZED STEEL PIPE
GRADE LINE
GOVERNMENT FURNISHED
GENERATOR
FLOOR DRAIN
FOUNDATION
FIRE HYDRANT
FLOOR LEVEL
FUEL OIL RETURN
FUEL OIL SUPPLY
FIRE WATER
EACH WAY
ENTERING, ENTRANCE
ESTIMATE
ETCETERA
EXPANSION JOINT
EXISTING
EXTERIOR
CONCRETE RUBBLE MASONRY
COATING, CUTTING
CLEARANCE
CONSTRUCTION
COLD WATER
CHECK VALVE
CONTRACTION JOINT
CENTER TO CENTER
CONCRETE PIPE
CORRUGATED
CONTINUOUS
CONNECTION
CONCRETE
CORNER
COLUMN
CURVE
GALV
HDW
HGT
HEX
H
HB
HEIGHT
GS-GSP
GND
GR
GT
GV
GEN
GFP(M)
GL
GROUND
GRADE
CUBIC METER PER SECOND
CEMENT MASONRY UNIT
CORRUGATED METAL PIPE
CONTROL JOINT
CENTER LINE
CONSTRUCTION JOINT
CAST IRON PIPE
CAULKING
CHANNEL
L
BOTTOM
BOTH SIDES
CAPACITY
CONDUIT
BLOW-OFF
BUILDING(S)
BRICK
BLOCK
FD
FIN OR FNSH
FOR
FW
FOS
FL
FHY
FDN
FINISH
EXIST
EW
EXT
ENT
EST
ETC
EXP JT
NOMENCLATURENOMEN
O TO O
PC
PCC
P
PAV
OUTL
OD
ORIG
O/H
OPNG
OPTL
O(.)C(.)
OA
OUT TO OUT
POINT OF CURVATURE
POLE
PAVEMENT
OUTLET
OUTSIDE DIAMETER
ON CENTER
ORIGINAL
OVERHEAD
OPENING
OPTIONAL
OVERALL
NO(.) OR #
NGL
MTG
NIC
MJ
N
NFSM
mm, MM
MISC
MIN(.)
MLD
MET
MAX(.)
MDL
MECH
MOUNTING
NUMBER
MECHANICAL JOINT
NON FROST SUSCEPTIBLE
NOT IN CONTRACT
MATERIAL
NATURAL GAS LINE
NORTH
MILLIMETERS
MISCELLANEOUS
MILLION LITERS PER DAY
MECHANICAL
MINIMUM
METAL
MAXIMUM
MIDDLE
PUBLIC WORKS
DRAINAGE MANHOLE
U/G ELECTRICAL CABLE LINE
ELEVATION
ELECTRICAL
ELECTRICAL MANHOLE
ENCLOSURE
ENGINEERING
DETAIL(S)
DRINKING FOUNTAIN
DIAMETER
DIMENSION
DUCTILE IRON PIPE
DISTRIBUTION
DROP MANHOLE
DRAIN OR DOOR
DWELLING
DRAWING(S)
DIRECTORATE OF
DRAIN LINE
ADHESIVE
DMH
AVERAGE
AS SOON AS POSSIBLE
ASPHALT
BARRACKS
BOILER HOUSE
BASE CIVIL ENGINEER
ANTITERRORISM/FORCE PROTECTION
BARRIER
AUTOMATIC
ARCHITECTURAL
APPROXIMATE
ALUMINUM
ABOVEGROUND
ALTITUDE
ANCHOR
ADJACENT
EL
ELEC
EMH
ENCL
ENGRG
E
EA
ECL
EAST
EACH
DSGN
DWEL
DWG(S)
DPW
DN
DP
DR
DESIGN
DOWN
DROP
ASBESTOS CONTAINING
ASBESTOS CEMENT PIPE
MATERIAL
AREA DRAIN
ASPHALTIC CONCRETE
ANCHOR BOLT
ADDITION
ACCESS
AIR COOLED CONDENSING UNIT
DIAG
DIM
DI-DIP
DISTR
DL
D
DET(S)
DF
DIA
DIAGRAM
DEPTH
IJ ISOLATION JOINT
KSC
L
M
LONG
LYT
LG
L
INVT
KPH
JT
IS
INTR
INSUL
INSTL
INL
KILOGRAMS PER SQUARE
CENTIMETER
LONGITUDINAL
LITERS
METERS
LAYOUT
LENGTH
LONG, LENGTH
KILOMETERS PER HOUR
INSECT SCREEN
INSTALLATION
INVERT
JOINT
INTERIOR
INSULATION
INLET
HORIZ
HWL
IE
ID
HW
HP
HM
INVERT ELEVATION
INSIDE DIAMETER
HIGH WATER LEVEL
HEADWALL, HOT WATER
HORSEPOWER, HIGH POINT
HORIZONTAL
HOLLOW METAL
RD ROAD
WOOD,
OR DITTO
WIRE MESH
WELDED
WELDED WIRE MESH
WATER
WEIGHT
WOODEN POLE
WITHOUT
TRANSFORMER
PERCENT
AND
AT
EQUAL
NUMBER
PLATE
PLUS OR MINUS
SAME AS ABOVE
WALL HYDRANT
WASTE DRAIN
WEST, WIDTH
WIND LOAD, WATER LINE
VERTICAL
VELOCITY
VALVE BOX
VARIOUS
STAINLESS STEEL
SPECIFICATION(S)
POWERLINE, STATIC PRESSURE
STEEL PIPE, OVERHEAD SECONDARY
SOLENOID VALVE
SEWER MANHOLE
SPEC(S)
STANDARD
SEPTIC TANK
STATION
SQUARE
STD
ST
STA
SST
SQ
SQUARE METER
SLOPE
SIMILAR
SHEET
SEWER LINE
SM, M2
SP
SOLV
SMH
SLP, S
SIM
SHT
SL
L
P
XFMR
SURFACE CLEANOUT
REINFORCING BAR
SHOULDER
SOUTH
SCALE
SADDLE
SECTION
RAW WATER, RETAINING WALL
SC
SHLDR
SCO
SDL
SECT
RW
S
REPLACE
REQUIRED
REVIEW, REVISE
ROOM
REPAIR
RECTANGULAR
REFERENCE
RELOCATED
REPL
REQ'D
REV
RM
RPR
RE-BAR
RECT
REF
RELOC
W/O
WWM
WTR
WT
WP
WM
WLD
WH
WL
WD
W/
W
WITH
VERT
VEL
VB
VAR(.)
CABLE LINE
TELEPHONE
TELEPHONE MANHOLE
TOTAL
TOP OF STEEL
STAIRWAY
STRUCTURAL
STORAGE
STEEL
SUSPEND(ED)
SWITCH
SYSTEM
TYPICAL
THROUGH
THICK
TITLE BLOCK
UNDERGROUND
TELEPHONE
TEMPORARY
THREAD
UNDERGROUND
UNIFORM
PERFORATED STEEL PLATE
REINFORCED CONCRETE PIPE
REINFORCED CONCRETE
POINT OF VERTICAL TANGENCY
POINT OF VERTICAL INTERSECTION
POLYVINYL CHLORIDE
POINT OF TANGENT
RUBBER
RADIUS
RIGHT
RCP
R(.)C
RBR
RAD, R
R
PARTITION
POWER
QUANTITY
PWR
PT
Q
PSP
PVT
PVI
PVC
PTN
TMH
UNIF
U/G
TOS
TOT
TYP
THD
THRU
TEMP
THK(.)
TEL
T/B
TCL
PRESSURE REDUCING VALVE
POINT OF INTERSECTION
OVERHEAD PRIMARY POWER LINE
PROJECT
PRESSURE
PREFABRICATED
PERMANENT
PRESSURE GATE
PAINT
PP
PRV
PROJ
PRESS
PREFAB
PERM
PG
PNT
PI STWY
SUSP
SW
SYS
STRL
STOR
STL
SUB DRAINSD
AIR VACUUM RELIEF VALVEAVRV
ACFT AIRCRAFT
POST INDICATOR VALVEPIV
NOT TO SCALENTS
A AREA
CI CURB INLET, CAST IRON
CO COMPANY
COMM COMMUNICATION
COMP COMPACTION
DUCTILE IRONDI
EXPANSION JOINTEJ, EXPJJ
ETHLENE PROPYLENE DIENE M-CLASSEPDM
FENCEFE
FIRE WATER LINEFWL
MFR MANUFACTURE
MH MANHOLE
NA NOT APPLICABLE
POLYETHYLENE PIPEPE
SURFACE INLETSI
SIGN POST
WELDED WIRE MESHWWMF
FABRIC
DIAMETERΦ
CURVE LENGTHCL
CONCRETE F'ck
COMPRESSIVE
STRENGTH
GRAY CAST IRON CASINGSGC
C CABLE
SQUAREQ(SQ)
STEEL BEARINGSTB
PLATEPL
ROOF TOP UNITRTU
HPU HEAT PUMP UNIT
ACU AIR CONDITIONING UNIT
AHU AIR HANDLING UNIT
A LIST OF SALVAGEABLE MATERIALS IN COORDINATION WITH CONTRACTING OFFICER.
11. PRIOR TO DEMOLITION WORK THE CONTRACTOR SHALL PROVIDE
REGULATION 201-1.
ENVIRONMENTAL GOVERNING STANDARDS FOR KOREA, USFK
APPLICABLE KOREAN ENVIRONMENTAL LAWS AND THE
10. ALL DISPOSAL WORK, SHALL BE IN ACCORDANCE WITH
THE SATISFACTION OF THE CONTRACTING OFFICER.
CONDITION AT NO ADDITIONAL COST TO THE GOVERNMENT AND TO
SHALL RESTORE THESE ITEMS TO THEIR ORIGINAL OR BETTER
NEGLIGENCE OR CONSTRUCTION OPERATIONS, THE CONTRACTOR
SHOULD THESE ITEMS BECOME DAMAGED DUE TO CONTRACTOR'S
RECEIVE THE PROPOSED UTILITIES, STRUCTURES AND/OR IMPROVEMENTS.
AS TO REMAIN SHALL BE MAINTAINED IN GOOD CONDITION TO
9. ALL UTILITIES, STRUCTURES AND/OR IMPROVEMENTS IDENTIFIED
PROJECT LIMITS SHALL BE REMOVED, UNLESS OTHERWISE INDICATED.
8. EXISTING DRAIN LINES AND DRAINAGE STRUCTURES WITHIN THE
900mm (3 FEET) OF THE FINAL GRADE.
TOP OF MANHOLES AND PITS SHALL BE DEMOLISHED WITHIN
ALLOW SEEPAGE OF WATER THROUGH THE ABANDONED MANHOLE.
THE BOTTOM OF MANHOLES AND PITS SHALL BE CRACKED TO
BE ABANDONED AND SHALL BE FILLED WITH STRUCTURAL BACKFILL.
REMOVED, UNLESS OTHERWISE INDICATED. MANHOLES AND PITS MAY
7. WATER AND SEWER LINES WITHIN THE PROJECT LIMITS SHALL BE
UNLESS OTHERWISE INDICATED.
THE PROJECT LIMITS SHALL BE DEMOLISHED AND REMOVED,
6. SIDEWALKS, CONCRETE PADS, CURBING AND OTHER ITEMS WITHIN
INDICATED.
LIMITS SHALL BE DEMOLISHED AND REMOVED, UNLESS OTHERWISE
5. EXISTING ASPHALTIC CONCRETE PAVEMENT WITHIN THE PROJECT
DEMOLISHED AND REMOVED, UNLESS OTHERWISE INDICATED.
4. ALL STRUCTURES WITHIN THE PROJECT BOUNDARY SHALL BE
ON BONIFAS DETERMINED BY THE CONTRACTING OFFICER.
SHALL BE CAREFULLY REMOVED AND TRANSPLANTED AT LOCATIONS
TREES, SHRUBBERY AND ORNAMENTAL PLANTINGS TO BE RETAINED
SHALL BE CLEARED, GRUBBED AND REMOVED FROM THE SITE.
SPECIFICALLY SCHEDULED TO BE RETAINED AND/OR TRANSPLANTED
3. ALL TREES, SHRUBBERY, AND ORNAMENTAL PLANTING NOT
ROADWAY, EXISTING CHAIN-LINK FENCE, ETC.
FOR THE PROJECT LIMITS, I.E. EDGE OF PAVEMENT, EDGE OF
FEATURES AND ROADWAYS SHALL BE USED AS A DEMARCATION
2. PROJECT LIMITS SHOWN ARE APPROXIMATE. EXISTING GROUND
LIMITS INDICATED, UNLESS OTHERWISE NOTED.
1. ALL DEMOLITION WORK SHALL BE CONFINED WITHIN THE PROJECT
DEMOLITION NOTES
THE CONTRACTING OFFICER SHALL BE PAYABLE BY THE CONTRACTOR.
THE COSTS INCURRED FOR ANY NECESSARY REMEDIAL ACTION BY
AND DEPOSITED IN DRAINAGE FACILITIES, ROADWAYS AND OTHER AREAS.
5. THE CONTRACTOR SHALL REMOVE ALL SILT AND DEBRIS RESULTING FROM HIS WORK
ELEVATION.
4. TOPS OF MANHOLES TO BE RETAINED SHALL BE ADJUSTED TO MATCH FINISH GRADE
OR UNPAVED AREAS TO PROVIDE A SMOOTH RIDING CONNECTION.
ADJUSTMENTS MAY BE REQUIRED AT CONNECTION OF NEW WORK TO EXISTING PAVED
PAVEMENT ELEVATIONS, UNLESS OTHERWISE INDICATED.
3. FINISH GRADES ALONG PAVED AREAS AS SHOWN ON THE DRAWINGS ARE TOP OF
THICK PRIOR TO SODDING.
ALL NEWLY GRADED AREAS SHALL BE TOP SOILED 100mm (4 INCHES)
HAS BEEN INTERRUPTED OR DELAYED, SHALL BE SODDED.
GRADING TO FINAL GRADE SHALL BE CONTINUOUS, AND ANY AREA WITHIN WHICH WORK
SODDING SHALL NOT BE DELAYED UNTIL ALL GRADING WORK HAS BEEN COMPLETED.
NO GAPS, AS SOON AS FINAL GRADES HAVE BEEN ESTABLISHED.
2. ALL EXPOSED AREA SHALL BE SOLID SODDED. SODDING SHALL BE PLACED WITH
150mm (6 INCHES) BELOW FINISH FLOOR ELEVATION, UNLESS OTHERWISE SHOWN.
1. THE FINISH GROUND ELEVATION AT THE BUILDING LINE SHALL BE A MINIMUM OF
GRADING NOTES
OFFICER AND THE USING AGENCY.
THE PROPOSED PROJECT LIMIT FOR APPROVAL BY THE CONTRACTING
THE CONTRACTOR SHALL PREPARE A WORK PLAN SHOWING
LOCATIONS OF TEMPORARY FENCING OR BARRICADES.
FOR THE PURPOSES OF DEFINING THE PROJECT LIMIT TO DETERMINE
SHOWN ON THE SITE DEVELOPMENT PLAN.
1. THE PROJECT LIMIT IS GENERALLY DEFINED BY THE GRADING LIMITS
PROJECT LIMIT
SCOPE OF WORK:
REPAIR AND MAINTENANCE WORK:
7. USE 1.22 METER FOR THE FROST DEPTH.
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
CLEAN. ALL COSTS INCURRED FOR SPILL CONTAINMENT AND CLEANUP
OFFICER SHALL OVERSEE THE CLEANUP EFFORT AND RENDER THE SITE
CONTAIN AND ADEQUATELY CLEANUP THE SPILL. THE CONTRACTING
THE CONTRACTING OFFICER AND UTILIZE APPROPRIATE MEASURES TO
CAUSED DURING CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY SEWAGE SPILLS
OF THE CONTRACTING OFFICER.
MODIFYING HIS/HER CONSTRUCTION METHOD, WITH THE APPROVAL
SUCH AS CONSTRUCTING SPECIAL REACTION BLOCKS AND/OR
WHATEVER MEASURES IS NECESSARY TO PROTECT THE WATER LINES,
EXISTING REACTION BLOCKS. THE CONTRACTOR SHALL TAKE
MOVEMENT DUE TO REMOVAL OF THE SUPPORTING EARTH BEYOND THE
TEES AND BENDS WHEREVER THERE IS A POSSIBILITY OF WATER LINE
BE ESPECIALLY CAREFUL WHEN EXCAVATING BEHIND WATER LINES,
ALL WATER LINES DURING CONSTRUCTION. THE CONTRACTOR SHALL
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF
THE CONTRACTING OFFICER AND THE AFFECTED USING AGENCIES.
UTILITY SERVICE AND/OR OPERATIONS WILL BE COORDINATED WITH
FACILITIES WILL BE KEPT TO A MINIMUM. ANY INTERRUPTION OF
4. INTERRUPTION OF UTILITY SERVICE AND/OR OPERATIONS OF ADJACENT
OFFICER IMMEDIATELY FOR REMEDIAL ACTION.
UTILITIES, THE CONTRACTOR SHALL INFORM THE CONTRACTING
UTILITIES ARE REQUIRED DUE TO UNFORESEEN CONFLICT WITH OTHER
3. WHENEVER ANY CHANGE IN ALIGNMENT OR GRADE FOR THE PROPOSED
TRENCHES FOR THE NEW UTILITY LINES.
VERIFY THEIR LOCATIONS AND DEPTHS PRIOR TO EXCAVATING
SHALL CAREFULLY EXPOSE THE UTILITY BY HAND EXCAVATION TO
UTILITIES CROSS EXISTING UTILITIES ARE SHOWN, THE CONTRACTOR
2. WHENEVER CONNECTIONS TO EXISTING UTILITIES OR WHERE NEW
CONDITION AND SHALL BE PAID FOR BY THE CONTRACTOR.
WORK, SHALL BE RESTORED IMMEDIATELY TO THEIR ORIGINAL OR BETTER
WHICH HAVE BEEN DAMAGED AS A RESULT OF THE CONSTRUCTION
EXISTING UTILITIES WHETHER SHOWN ON THE DRAWINGS OR NOT
ALL SUCH UTILITIES AT ALL TIMES, UNLESS OTHERWISE INDICATED.
SIZE AND INVERTS OF ALL EXISTING UTILITIES AND SHALL PROTECT
THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION,
COMPLETE AND ACCURATE.
POSSIBLE BY FIELD SURVEYS. HOWEVER THIS INFORMATION MAY NOT BE
RECORDS, AND APPLICABLE UTILITY MAPS, VERIFIED WHENEVER
APPURTENANCES AND STRUCTURES SHOWN ARE BASED ON AVAILABLE
1. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITIES,
UTILITY NOTES
CONTRACTING OFFICER.
5. THE CONTRACTOR SHALL COORDINATE ALL PHASES OF WORK WITH THE
AND UTILITIES.
ARE NOT LIMITED TO PAVEMENTS, CONCRETE SIDEWALKS AND CURBS,
CONDITION, UNLESS OTHERWISE NOTED. THESE ITEMS INCLUDE, BUT
REMOVED AS A RESULT OF CONSTRUCTION TO ITS ORIGINAL OR BETTER
4. THE CONTRACTOR SHALL RESTORE ALL IMPROVEMENTS, DAMAGED OR
6 DEC 2017.
- THE ORIGINAL FIELD SURVEY FOR PROJECT WAS COMPLETED
- ELEVATIONS ARE MEAN SEA LEVEL.
IS FROM SURVEY DONE BY THE GEOTECH (G&E) BRANCH, FED.
3. THE EXISTING TOPOGRAPHIC INFORMATION SHOWN ON THE DRAWINGS
AND/OR MILITARY TRAFFIC AND OPERATIONS.
PRECAUTIONS FOR THE PROTECTION AND SAFETY OF THE PUBLIC
AND OTHER PROTECTIVE FACILITIES AND SHALL TAKE ALL NECESSARY
NECESSARY SIGNS, LIGHTS, FLARES, BARRICADES, MARKERS, CONES
2. THE CONTRACTOR SHALL PROVIDE, INSTALL, AND MAINTAIN ALL
OF THE CONTRACTING OFFICER.
ANY DISCREPANCIES SHALL BE BROUGHT IMMEDIATELY TO THE ATTENTION
DRAWINGS PRIOR TO THE START OF CONSTRUCTION.
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AS SHOWN ON THE
GENERAL NOTES
1 REPLACE EXISTING DRAINAGE SYSTEM (CONCRETE DITCHES).
(CONCRETE SIDEWALK AND CONCRETE DITCH CROSSING).
REPLACE EXISTING SITE ITEMS
REPLACE EXISTING SOLID SODDING.
)BLDG #127- (
G D50
G D50
RW RW
W D150
W D150
W D150
W D150
W D150
W D150
W D150
W D150
W D150
W D150
SAN
D200
SAN
D200
SAN
D200
NEWEXIST REMOVAL
SAN
A
WOODEN FENCE
CHAIN LINK FENCE
CMU WALL FENCE W/ BARBED WIRE
CHECK VALVE
WATER LINE W/ AIR & VACUUM RELIFE VALVE
RAW WATER LINE
POST INDICATOR VALVE
WATER LINE W/ FIRE HYDRANT
WATER LINE W/ GATE VALVE W/ GATE VALVE BOX
WATER LINE W/ VALVE & VALVE BOX AND MANHOLE
GREASE TRAP
SEWER LINE W/ SEPTIC TANK
SEWER LINE W/ SMH
SEWER LINE W/ SCO
A
NATURAL GAS LINE
A
W
CONTOUR LINE
SPOT ELEVATION
U/GA/G
23.60
A/G & U/G FUEL OIL STORAGE TANK
EVERGREEN OR DECIDUOUS TREE
RC RETAINING WALL
23.60
NEWEXIST REMOVAL
RICE PADDY
WATER LEVEL
DRY FARM
GRAVE & CEMETERY
B95-359
EL 88.06
NORTH DIRECTIONAL ARROW
N
AND EXISTING GROUND ELEVATION
W/ BORING NUMBER
LOCATION OF SOIL BORING
CO
S
ST
GT
W
W
D200
SAN
D200
SAN
D200
SAN
D200
SAN
D200
SAN
D200
W D150
RW
W D150
W D150
W D150
W D150
G D50
NEW CONSTRUCTION WORK:
PROVIDE CONCRETE PAD.
X X
X X X X X X
X X X X
CONC STEPS W/ HANDRAILS
CONC SLAB & CONC SIDEWALK
BUILDING
SD
D600
DRAIN LINE W/ SURFACE INLET
DRAIN LINE W/ DMH
CONC DITCH, CONC COVERED
CONC OPEN DITCH
W/ DIRECTION OF FLOW
GROUTED STONE OPEN DITCH
DIRT ROAD
CULVERT W/ HEADWALL & ENDWALL
ASPHALTIC CONC PAVED ROAD W/ CURB
D SD
D600
D
SD
D600
SI SD
D600
SI
DRAIN LINE W/ JUNCTION BOXSD
D600
JB SD
D600
JB
DRAIN LINE W/ CURB INLETSD
D600
CI SD
D600
CI
S-1504
SD
D600
SD
D600
SI
SD
D600
SD
D600
CI
CP
J
NEWREMOVALEXIST
D
G-003
N O
T E
S L E
G E
N D S
C O
P E O
F W
O R
K
C
IV
IL
A
B B
R E
V
IA
T
IO
N S
EXTERIOR INSULATION CONTROL JOINT EICJ
FINNED TUBE RADIATORFTR
FCO FLOOR CLEAN OUT
SHD SOAP HOLDER
TYPE)
SOAP DISPENSER (LAVATORY MOUNTEDSD
ROOF TRUSS
SURFACE INLET SI
RIDGE VENT
RAW WATER
RIVET
REFRIGERATION TON
REPAIR
RETURN AIR REGISTER
LEVELLVL
DWELLINGDWEL
DWG(S) DRAWING(S)
CATALOGCAT
ASPHALT TIRE TILEATT
ACOUSTICAL WALL PANELAWP
SAWP SOUND ABSORPTION WALL PANEL
PAVEMENTPAV, PVMT
LFT LINEAR FEET
POUND LB
LIVE LOADLL
HARDENER HDR
GLAZED CERAMIC WALL TILEGCWT
EXTERIOR INSULATION & FINISH SYSTEM EIFS
DIVISIONDIV
DOWNSPOUTDS
CEMENT PLASTERCPL
ACOUSTICAL TILEACST
WATER LINE WL
AB
A/C
AD
ADH
ACS
AHR
ARCH
ALT
APPX
APPROX
AL
ADJ
AE
ASAP
ASTM
AUTO
ATC
ASPH
AIR EXTRACTOR
MATERIAL
AMERICAN SOCIETY FOR TESTING &
AUTOMATIC
AS SOON AS POSSIBLE
ACOUSTIC TILE CEILING
ASPHALT
ARCHITECTURE
APPROXIMATE
ALTERNATE
APPENDIX
AIR CONDITIONING
ANCHOR
ALUMINUM
ADHESIVE
ADJACENT
AREA DRAIN
ACCESS
AT
ANCHOR BOLT
BN BULL NOSE BLOCK
BS
BRK
BP
BOTH SIDES
BASE PLATE
BRICK
BARRACKSBKS
BOT
BLKG
BLDG(S)
BOTTOM
BUILDING(S)
BLOCKING
ACCESSORYACCESS
BC
BD
BARR
BOARD
BOTTOM CHORD
BARRIER
AP ACCESS PANEL
AVG
ASSY
AC
ASSEMBLY
AVERAGE
ASPHALTIC CONCRETE
CHECK VALVECV
CWB CAPILLARY WATER BARRIER
CEMENT BOARDCB
CH
CT
CAP
CEILING HEIGHT
CERAMIC TILE, COUNTER TOP
CAPACITY
CHAN
CD
CHANNEL
CEILING DIFFUSER
CTRJ
CUFT
CTG
CS
CUBIC FOOT
COATING, CUTTING
CONTRACTION JOINT
CRV
CPC
CORR
COR
CEMENT PLASTER CEILING
CURVE
CORNER
CORRIDOR
CONCRETE MASONRY UNITCMU
CONN
CONST
CONC
COL
CONSTANT
CONNECTION
COLUMN
CONCRETE
CMT
CFM
CLWR
CERAMIC MOSAIC TILE
CLEAR WIRE GLASS
CUBIC FEET PER MINUTE
CLG
CLKG
CLR
CL OR C
CLJ
CEILING, COOLING
COLOR, CLEAR
CAULKING
CONTROL JOINT
CENTER LINE
CI
CIP
CAST IRON
CAST IRON PIPE
CF
C TO C CENTER TO CENTER
COLUMN FOOTING
HEX
H/V
HORIZ
HR
HW
HDWD
HDBD
HTR
HZ
HP
HGT
HM
HDW
H
HB
GENL
GPM
DISC DISCONNECT
DBL DOUBLE
DST
DSGN
DOOR STOOP
DESIGN
HEXAGON
HORIZONTAL
HEATING AND VENTILATION
HOT WATER
HARDWOOD
HARD BOARD
HEATER
HORSE POWER
HERTZ
HOLLOW METAL
HEIGHT
HARDWARE
HOSE BIBB
HIGH, HEAD, HORIZONTAL
GENERAL
GALLON PER MINUTE
MFR
MM
MANUFACTURE
MILLIMETER
MO
MIRR
MB
MS
MASONRY OPENING
MIRROR
MACHINE BOLT
METAL SCREW
PERM
MISCELLANEOUSMISC
MTG
MT
MSCR
MOUNTING
METAL THRESHOLD
MACHINE SCREW
MEZZ
MIN
MET
METD
MEZZANINE
MINIMUM
METAL
METAL DOOR
MATERIALMATL
MC
MECH
MDL
MAX
MAGNETIC CONTACTOR
MECHANICAL
MIDDLE, MODULE
MAXIMUM
MACH
M & R
MPH
MACHINE
MAINTENANCE & REPAIR
MILES PER HOUR
PTN
PREFAB
PRF
PROJ
PLYWD
PNL
PH
PLAS
LPS
LTG
LT
LOWER PRESSURE SODIUM
LATCHING THRESHOLD
LIGHTING
LVG
LTY
LVD
LEAVING
LOUVERED DOOR
LAYOUT
LENGTHLG
LONG
LTC
LNTL
LATTICE
LONGITUDINAL
LINTEL
LAV
L
LAVATORY
LONG
PED
PDVN
PB
PIV
PC
P
OPNG
OUT
OD
OPTL
ORIG
O/H
OL
OC
KS
KW
KOREAN STANDARD
KILOWATT
JT
J
JOIST
JOINT
INCL
IN
INCLUDE
INCH
NFSM
OA
O TO O
NTS
NIC
NO OR #
PERMANENT
PARTITION
PREFABRICATED
PROOF
PROJECT
PANEL
PLYWOOD
PLASTER
PHASE
SCR
SDG SIDING
SHOWER CURTAIN ROD
SEL
SC
SCD
SELECTOR
SCALE
SCREEN DOOR
PEDESTAL
POWER DRIVEN
PUSH BUTTON
POST INDICATOR VALVE
POLE, PLATE, PAPER, PAINT
PILE CAP
OPENING
OUTSIDE DIAMETER
OUTLET
OPTIONAL
ORIGINAL
OVERLOAD
OVERHEAD
ON CENTER
THROUGH THRU
TECH
TYP
TW
TS
TYP
TV
TOT
T.O.S.
TH
TYPICAL
TECHNICAL
TILE WAINSCOT
TONS
TYPICAL
TOTAL
TURNING VANES
THERMOMETER
TOP OF STEEL
TEMP
THK
TEL
TC
T/B
STOR
STIFF
SCHED
SKD
SG
SYS
TEMPORARY, TEMPERATURE
THICKNESS
TERRA COTTA
TELEPHONE
TITLE BLOCK
STORAGE
STIFFENER
SINGLE KEYED DIFFERENT
SCHEDULE
SUPPLY AIR GRILLE
SYSTEM
NON FROST SUSCEPTIBLE MATERIAL
OVERALL
OUT TO OUT
NOT TO SCALE
NOT IN CONTRACT
NUMBER
SUSP
SW
STWY
STD
STRL
STL
STA
SS
SUSPENDED
SWITCH
STAIRWAY
STANDARD
STRUCTURAL
STEEL
STATION
STAINLESS STEEL
STEEL SHEET OR SERVICE SINK
BRKR BREAKER
CAST STEEL
DR
DP
DN
DL
DIM
DIA
DET(S)
DF
DIAG
DROP, DEW POINT
DOWN
DRAIN OR DOOR
DAYLIGHT, DRAIN LINE, DEAD LOAD,
DISTRIBUTION
DIMENSION
DIAGRAM
DIAMETER
DETAIL(S)
DRINKING FOUNTAIN
DESIGN PACKAGE
INSTL INSTALLATION
IDENT
IAW
INCAND
IS
INTR
INVT
IJ
INSUL
IDENTIFICATION
IN ACCORDANCE WITH
INCANDESCENT
INSECT SCREEN
INTERIOR
INVERT
ISOLATION JOINT
INSULATION
INL
ID
INLET
INSIDE DIAMETER
INDIRECT DRAIN
SN SERIAL NUMBER
SPECIFICATION(S)
SPACE HEATER
STROKES PER MINUTE
SPH
SPM
SPEC(S)
SHOULDER
SHOWER HEAD
SECTION
SADDLE
SECT
SH
SHLDR
SDL
UNDER GROUND UGND
UL
& AND
UNDERWRITERS LABORATORIES
TELECOMM
UNIF
UH
U
UR URINAL
"U" SHAPED STIRRUP
UNIT HEATER
UNIFORM
TELECOMMUNICATION
SLP
SIM
SLOPE
SIMILAR
V
VAC
VB
VOLT
VACUUM
VALVE BOX
VENT
VERT
VENTILATOR
VERTICAL
VOLUME
VESTIBULE
VOL
VEST
VARIES OR VARIABLE
VAPOR RETARDER VR
VCB
VAR
VINYL COVE BASE
WIND LOAD
WALL HYDRANT
WINDOW
WIDTH OR WOOD
WITH
WATER CLOSET
WOOD BASE
WAINSCOT
WC
WB
WD
WL
WH
WDO
W/
WA
WATER LINE OR WALL
WALL BOARD WLB
WELDED WIRE FABRIC
WEIGHT
WORKING POINT
WITHOUT
WIRE MESH
WF
WWF
WTR
WT
WP
W/O
WM
WALL FOOTING
WATER
GIRDER, GLASS
GENERATOR
GALVANIZE
(MATERIAL)
GRADE LINE
GALVANIZED STEEL SHEET
GLAZED WALL TILE
GYPSUM WALL BOARD
GALVANIZED STEEL PIPEGSP
GWB
GWT
GSS
GFM(M)
GEN
GND
GL
GALV
GAL
GA
G
GROUND
GALLON
GAGE
EVAPORATINGEVAP
DEGREE FAHRENHEIT
FLAT HEAD METAL SCREW
FEET PER MINUTE
FLAT HEAD WOOD SCREW
FISCAL YEAR
FIRE HYDRANT
FLOOR, FLASHING, FLUSH
FAR SIDE, FULL SIZE
FAN COIL UNIT
FINISH FLOOR, FACTORY FINISH
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
ET CETERA
ELECTRIC WATER COOLER
ELECTRICAL
EMERGENCY
FLUORESCENT
FLOOR DRAIN
FOUNDATION
FEDERAL, FAR EAST DISTRICT
FIRE DOOR
EACH WAY
FHWS
FRAMG
FEC
FE
FRZA
FF
FNSH
FY
FRAMING
FREEZER
FINISH
FT
FHMS
FPM
FCU
FXD
FXTR
FS
FR
FOOT
FIXED
FIXTURE
FRAME
FDR
FL
FHY
FED
FD
FDN
FAC FACTOR
FLUOR
EMER
EWC
EW
ETC
ELEC
EXTERIOR
ENCLOSURE
ELEVATION
ENGINEERING
EPOXY, EXPLOSION PROOF
EXHAUST
ESTIMATE
ENTRANCE
EXPANSION JOINT
EL OR ELEV
ENGRG
EXP JT
ENT
EXH
EP
EST
ENCL
EXST
EA
EXT
EXISTING
EACH
PL PLATE
QUANTITY
QUARRY TILE FLOOR
QUARRY TILE
RETURN AIR GRILLE
RAIL, RIGHT
RADIUS
RR
REINFORCED CONCRETE
RUBBER
REINFORCING BAR
RECEPTACLE
REINFORCED CONCRETE PIPE
REFERENCE
RECTANGULAR
RELOCATED
REPLACE
REVIEW, REVISE
ROOF DRAIN
RPR
ROOM
REQUIRED
REVOLUTIONS/ MINUTE
RT
RVT
RW
RV
ROUND HEAD METAL SCREW
ROUND HEAD WOOD SCREW
ROUGH OPENING
ROOF LINER
REINFORCEMENT
RETAINING
REFLECTED
REFRIGERATOR
REQ'D
REFR
REFL
RET
REINF
RO
RL
RHMS
RHWS
RPM
RD
RM
REV
RE-BAR
RELOC
REPL
RECT
REF
RCPT
RCP
RC
RBR
R
RG
QTF
QT
QTY
POUNDS/SQUARE FOOT
PROTECTION
PREMOLDED EXPANSION JOINT
PORTLAND CEMENT CONCRETE
POINT OF CONNECTION
PROVIDE
POUNDS/SQUARE INCH GAGE
POUNDS/SQUARE INCH
PRESSURE
POWER
PSF
PEJ
PROT
PROV
POC
PSIG
PCC
PRESS
PSI
PWR
CONT CONTINUOUS
CHEMICAL BIOLOGICAL & RADIOLOGICALCBR
CCA CONTAMINATION CONTROL AREA
SMLD SHELF METAL LIGHT DUTY
SND SANITARY NAPKIN AND TAMPON
DISPOSER
TTD TOILET TISSUE DISPENSER
E/S EYE SHOWER
URINAL SCREEN US
HS HAND SINK
PTD PAPER TOWEL DISPENSER
CONTRACTOR FURNISHED CONTRACTORCFCI
INSTALLED
GOVERNMENT FURNISHED CONTRACTORGFCI
INSTALLED
GFGI GOVERNMENT FURNISHED GOVERNMENT
INSTALLED
ALKYDAK
HIGH PERFORMANCE ARCHITECTURALHL
LATEX
INSTITUTIONAL LOW ODER/LOW VOC LATEXIL
HEAT RESISTANT ENAMEL
PP PIGMENTED POLYURETHANE
EGGSHELLE
F FLAT
SEMI-GLOSS S
SATIN, SELF-TAPPING ST
VTR VENT THROUGH ROOF
SKIM COAT OF PLASTERSCP
HIGH IMPACT WALL COVERINGHWC
CPT CARPET
FMF FLOOR MATS & FRAMES
GROUTGR
LC LAVATORY COUNTER TOP
PLASTIC LAMINATE
RCB RUBBER COVE BASE
RUBBER TILE
SST
VAPOR BARRIER
VINYL WALL COVERING VWC
VWCB VINYL WALL COVERING BORDER
GUTTER EXPANSION JOINTGEJ
CPT/T CARPET TILE
VINYL COMPOSITION TILE VCT
VT VINYL TILE
L
DISTR
DRAWING LIST
GOVERNMENT FURNISHED PROPERTY
HOUR
RAD
STC SOUND TRANSMISSION CLASS
L1W1
ARCHITECTURAL
MATERIAL INDICATIONS AND SYMBOLSA B B R E V I A T I O N S
DOOR NUMBER
WINDOW & LOUVER NUMBER
ROOM NAME AND NUMBER
SCOPE OF WORK NUMBER
CONCRETE
GROUT & SAND
GRAVEL OR BASE MATERIAL
CONCRETE MASONRY UNIT(CMU)
WOOD, ROUGH
WOOD, FINISH
BRICK
GRANITE
REINFORCED CONCRETE
EARTH
GYPSUM BOARD
METAL, ROUGH
FIBERGLASS BATT INSULATION
PLYWOOD
RIGID INSULATION
CEMENT BOARD
SOLID SURFACE MATERIAL
OFFICE
S Y
M B
O L S
A B
B R
E V
IA
T
IO
N S
M A
T E
R
IA
L I
N D
IC
A T
IO
N S
J .H L E
E
G-004
D
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
Y I, S
C
C P B
O N
IF
A S
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
O R
E A
F E
W
A
P R
M E C H A N I C A L M A T E R I A L I N D I C A T I O N S & S Y M B O L S
NTS
PD
Pa
OS&Y
OXY
OD
OAIL
OA
QT
PRV
PPM
POL
POC
PLMB
PH
PG
RT
RPM
RH
RDTR
RA
R12, R22
QTY
A B B R E V I A T I O N S
SBM
SAN
SA
SCH
FLOWMETER, ORIFICEBUTTERFLY
REFRIGERANT LIQUID
CHILLED WATER SUPPLY
CHILLED WATER RETURN
AIR COOLED CONDENSING UNIT
AIR CONDITION UNIT (S)
APPARATUS DEW POINT
AIR CONDITION (-ING,-ED)
HOT CHILLED WATER RETURN
AMERICAN WIRE GAUGE
PRESSURE, BAROMETRIC
CUBIC METER PER HOUR
HOT/CHILLED WATER SUPPLY
CAPACITYCAP
CONNECTION
CONTINUE
COMPRESSOR
CUBIC METER
CPRSR
CONN
CONT
CU M
CHILLED WATER
CAST IRON PIPE
CIRCUIT
CLASSIFICATION
COOLING LOAD
COEFFICIENT
COUNTER CLOCKWISE
CLASS
CLG LOAD
COEF
CMH
CIP
CCW
CHW
CKT
ACV ALARM CHECK VALVE
AVERAGEAVG
BOILING POINT
CENTIGRADE
BAROMETER(-TRIC)
BRAKE HORSEPOWER
BP
BHP
C
BARO PR
AWG
BARO
ALUMINUM
ALTITUDE
AMBIENT
AIR HANDLING UNIT
AMPERE(AMP, AMPS)
APPROXIMATEAPPROX
ALT
AMB
AMP
AIR COND
ADP
AL
AHU
AIR COOLED
ACCU
ACLD
ACU
CHR
C/HWR
C/HWS
CHS
RL
D DRAIN
DIAMETER, INSIDE
ISOMETRIC
IRON PIPE SIZE
JOULE
THERMAL CONDUCTIVITY
KILOGRAM
KILOGRAM PER SQ. CENTIMETER (GAUGE)
KILOGRAM PER SQ. CENTIMETER
KILOGRAM PER SQ. CENTIMETER (ABSOLUTE)
KILOCALORIE PER HOUR
EXPANSION JOINT
EXPLOSION PROOF
FIRE HOSE CABINET
FULL LOAD AMPERES
ENTERING WATER TEMP
EVAPORAT (-E,-ING,-ED,-OR)
EXTERNAL STATIC PRESSURE
FACE AREA OR FRESH AIRFA
FHC
FHY
FLA
FIRE HYDRANT
ESP
EXPJT
EWT
EVAP
EP
EQPT
ENT
EFF
EQUIPMENT
ENTERING
EFFICIENCY
KG/SQ CM
KG/SQ CM A
KG/SQ CM G
KG
KCAL/HR
J
K
ID
ISO
IPS
NO
N.O.
NIC
NPT
MPS
NC
N/A
N.C.
MAX
MIN
MPH
MM
NOT IN CONTRACT
NATIONAL TAPER PIPE (THREAD)
NUMBER
NORMALLY OPEN
MINIMUM OR MINUTE
METERS PER HOUR
METERS PER SECOND
NORMALLY CLOSED
NOISE CRITERIA
NOT APPLICABLE
MAXIMUM
MILLIMETER
R
FEMALE PIPE THREAD
FUEL OIL
GALVANIZED STEEL
GAGE OR GAUGE
FIXTURE
FEED WATER PUMP
FACE VELOCITY
FLUSH VALVE
FREQUENCY
FIBERGLASS REINFORCED PLASTIC
HORIZONTAL
HOT WATER HEATER
HOT WATER
HOUR(S)
HORSEPOWER
MERCURY
HEAD
HOSE BIBB
HERTZ
GRAMS
FRP
CWP CIRCULATING WATER PUMP
DIRECT EXPANSION
DRY PIPE VALVE
EQUIVALENT DIRECT RADIATION
ENTERING AIR TEMPERATURE
DOUBLE POLE DOUBLE THROW
DEWPOINT TEMPERATURE
DRY BULB TEMPERATURE
DECIBEL OR DRY BULB
DIESEL OILDO
ECON
ECC
EAT
EDR
DX
DPV
DPDT
DPT
ECONOMIZER
ECCENTRIC
o
DIFF
DIAG
DIA or
DIV
DBT
DB
DIFFERENCE
DIAGRAM
DIAMETER
DIVISION
DEGREE
HR
HORIZ
HWH
HW
HZ
HP
HG
HD
HB
GALVS
GA
GR
FXTR
FWP
FVEL
FV
CUBIC MILLIMETER
CLOCKWISE OR COLD WATER
COEFFICIENT, VALVE FLOWCv
CU MM
CW
PLUG VALVE
THREE WAY
FPT
FO
FREQ
GATE, ANGLE
GATE, GLOBE
GLOBE
GATE
CONTROL
KJ KILOJOULE
LH
LT
LWT
LPS
M
LL
LPD
LPH
LM
LAV
LAT
LBS
LG
KW
KWH
L
LATENT HEAT
LEAVING WATER TEMPERATURE
LITERS PER HOUR
LITERS PER SECOND
LAUNDRY TRAY
METERS
LIQUID LINE
LITERS PER DAY
LINEAR METER
LEAVING AIR TEMPERATURE
LAVATORY
POUNDS
LENGTH
KILOWATT
KILOWATT HOUR
LITERS
P
FLOWMETER, VENTURI
FLOW SWITCH
PRESSURE SWITCH
PRESSURE GAUGE AND COCK
PUMP (INDICATE USE)
STRAINER
STRAINER, BLOW OFF
KG/SM
KG/SM A
KG/SM G
PS
P
OFM
FS
VFM
KILOGRAM PER SQ. METER
KILOGRAM PER SQ. METER (ABSOLUTE)
KILOGRAM PER SQ. METER (GAUGE)
JACKET WATER RETURN
MEDIUM PRESSURE STEAM
MEDIUM PRESSURE CONDENSATE
LOW PRESSURE STEAM
LOW PRESSURE CONDENSATE
BOILER BLOW DOWN
PUMPED CONDENSATE
JACKET WATER SUPPLY
VACUUM PUMP DISCHARGE
FUEL OIL TANK VENT
CONDENSATE WATER SUPPLY
CONDENSATE WATER RETURN
MEDIUM TEMPERATURE HOT WATER SUPPLY
MEDIUM TEMPERATURE HOT WATER RETURN
LOW TEMPERATURE HOT WATER SUPPLY
LOW TEMPERATURE HOT WATER RETURN
PIPE TO BE REMOVED
REFRIGERANT DISCHARGE
REFRIGERANT SUCTION
LPS
CONTROL AIR MAIN
air conditioning and refrigeration
RD
RS
(NAME)E
(NAME)
M
EXISTING PIPE
COMPRESSED AIR
VACUUM (AIR)
HWR
VAC
A
MTWS
MTWR
HWS
FOD FUEL OIL DRAIN
FOR
CS
CR
FOV
FOG
FOS FUEL OIL SUPPLY
FUEL OIL RETURN
FUEL OIL GAUGE
PC
VPD
MU
LPC
BBD
MAKE UP WATER
MPS
MPC
JWR
JWS
heating
PIPING
CHECK, SWINGSANITARY DRAIN
PITCH OR PIPE, UP(U), DOWN(D)
FLOOR SINK (200mm x 200mm)
PIPE SLEEVE WITH FIRE STOPPING
VENT THRU ROOF
BFP
valves : (for selective actuators)
PLAN
HOSE BIBB
AIR LINEA
BALL
ELEV.
BACKFLOW PREVENTER
PIPE SLEEVE
(NAME)
ACID
200mm x 200mm
SURFACE CLEANOUT
FLOOR CLEANOUT
FLOOR DRAIN
CHEMICAL SUPPLY PIPES
FUNNEL DRAIN, OPEN
FCO
FD
SCO
FLOOR OR GRADE
FLOOR OR GRADE
CONDENSATE DRAIN BELOW
CONDENSATE DRAIN ABOVE
ACID WASTE
GASG
CD
CD
AIR VENT, MANUAL
AIR VENT, AUTOMATIC
W/ MEASURING TAP
EXPANSION LOOP
EXPANSION JOINT
BALL JOINT
ANCHOR, MAIN
ANCHOR, INTERMEDIATE
ALIGNMENT GUIDE
AIR SEPARATOR
FLEXIBLE CONNECTOR
SQUARE HEAD BALANCING COCK
EJ
S
MV
AVV
CHECK, NON-SLAM
CONTROL, ELECTRIC-PNEUMATIC
CONTROL, PNEUMATIC-ELECTRIC
QUICK OPENING
PRESSURE REDUCING
NEEDLE
LOCK SHIELD
HOSE END DRAIN
SAFETY
RELIEF
SQUARE HEAD BALANCING COCK
QUICK CLOSING, FUSIBLE LINK
R
S
PE
EP
plumbing
COLD WATER
HOT WATER RETURN
HOT WATER SUPPLY
VENT
MOTOR ELECTRIC
DIAPHRAGM
valves, special duty :
SOLENOIDS
valve actuators
M
FDAD
SUCTION
QUANTITY
SUCT
TONS OF REFRIGERATION
TEMPERATURE DIFFERENCE
HEAT TRANSFER COEFFICIENT
SANITARY
SUBMERSIBLE
SUPPLY AIR
SCHEDULE
RADIATOR
REFRIGERATION TON
REVOLUTIONS PER MINUTE
RELATIVE HUMIDITY
RETURN AIR
THERMAL RESISTANCE
REFRIGERANT (12, 22, ETC)
TYPICALTYP
URINAL
UNIT HEATER
UR
UH
U
THERMOSTAT
THICKNESS
THERMOMETER
TEMPERATURE
SYMBOL
TSTAT
TONS
THERM
THK
TEMP
TD
SYM
SINGLE POLE DOUBLE THROW
LPH, STANDARD CONDITIONS
LPS, STANDARD CONDITIONS
LPD, STANDARD CONDITIONS
SAYBOLT SECONDS UNIVERSAL
SAYBOLT SECONDS FUROL
SENSIBLE HEAT
OUTSIDE AIR INTAKE LOUVER
SH
PRESSURE DROP OR DIFFERENCE
PRESSURE REDUCING VALVE
PHASE (ELECTRIC)
PERCENT
PARTS PER MILLION
POINT OF CONNECTION
PLUMBING
PETROLEUM, OIL AND LUBRICANTS
QUART
OUTSIDE SCREW & YOKE
DIAMETER, OUTSIDE
PRESSURE GAGE
POLE
PASCAL
OXYGEN
SPRINKLERSPR
STEEL
STANDARD
STEAM
SQUARE
STAINLESS STEEL
STORAGESTOR
STL
STD
ST
SSU
SST
SSF
SQ
SENSIBLE LOAD
STATIC PRESSURE
SQUARE METER
SPECIFICATION
SPDT
SPEC
SM
SP
SLPH
SLPS
SLPD
SL
ALARM CHECK VALVE
SIDEWALL SPRINKLER
PENDENT SPRINKLER
UPRIGHT SPRINKLER
FIRE DEPARTMENT CONNECTION
PRE-ACTION VALVE
NOT TO SCALE
OUTSIDE AIR
(2-WAY SHOWN)
DRY-PIPE VALVE
SECOND
SAFETY FACTOR
SPECIFIC GRAVITYSG
SF
SEC
VARIABLE AIR VOLUMEVAV
VENTILATION
PRESSURE, DYNAMIC(VELOCITY)
WATER-COOLED
WATER CLOSET
WATTHOUR OR WATER HEATER
WET BULB TEMPERATURE
WATERPROOF
WSHR
WCLD
WTRPRF
WH
WT
W/
WD
WC
WBT
WEIGHT
WITH
WASHER
WIDTH
VP
VOL
WB
W
VISC
VERT
VENT
VEL
VOLUME
WET BULB
WATT
VISCOSITY
VERTICAL
VELOCITY
MANUAL VOLUME DAMPER
SMOKE DAMPER (PROVIDE ACCESS DOOR)
PNEUMATIC OPERATED DAMPER
VLV
V
VAC
M
VALVE
VOLT
VACUUM
SPLITTER DAMPER
SD
AD
VD
grilles, registers and diffusers :
SG
SR
600/300
300x150
200mm NCD
FIGURE IS ON TOP
810mm x 400mm dampers
ELBOW, TURNED DOWN
REDUCER, CONCENTRIC
REDUCER, ECCENTRIC (STRAIGHT, INVERT)
REDUCER, ECCENTRIC (STRAIGHT, DOWN)
TEE, OUTLET DOWN
TEE, SINGLE SWEEP
sprinkler
UNION, SCREWED
UNION, FLANGED
TEE, OUTLET UP
TEE
LATERAL
CONNECTION, BOTTOM
CONNECTION, TOP
ELBOW, TURNED UP
BUSHING
CAP
WELDED
FLANGED
SOLDERED
SCREWED BELL AND SPIGOT
SOLVENT CEMENT
SOUND ATTENUATOR
DETECTORS, FIRE AND/OR SMOKE
ELECTRIC MOTOR OPERATED DAMPER
FIRE DAMPER (PROVIDE ACCESS DOOR)
BACKDRAFT DAMPER
BDD
S
TRANSITION
TURNING VANES
SF
CHANGE OF ELEVATION, RISE(R), DOWN(D)
DUCT SECTION, NEGATIVE PRESS., FIRST
ACCESS DOOR, VERTICAL OR HORIZONTAL
COWL, (GOOSENECK) AND FLASHING
ACOUSTICAL LINING
FLEXIBLE DUCT
FLEXIBLE CONNECTIONFC
FIGURE IS ON TOP
R
AD
47.2
TG
94.4
UC 13mm
DG
500/300L
DUCT WORK
810mm x 400mm
810mm x 400mm
THERMOSTAT, ELECTRIC
TRAP, ELECTRIC (INDICATE TYPE)
fitting :
R
THERMOMETER
EXHAUST AIR GRILLE OR REGISTER, CEILING
DUCT SECTION, POSITIVE PRESS., FIRST
DIRECTION OF FLOW
SR
DIFFUSER, LINEAR
RETURN AIR GRILLE OR REGISTER, CEILING
CEILING DIFFUSER, SQUARE TYPE
CEILING DIFFUSER, ROUND TYPE (200mm
(600mm x 300mmH, 472 LPS)
UNDERCUT DOOR (13mm, 47.2 LPS)
DOOR GRILLE (300mmx150mmH)
NECK DIAMETER)
TRANSFER GRILLE ASSEMBLY
LOUVER, DOOR OR WALL
(500mmWx300mmH, 94.4 LPS)
RG
RR
SUPPLY AIR GRILLE OR REGISTER, SIDEWALL
EXHAUST AIR GRILLE OR REGISTER, CEILING
SUPPLY AIR GRILLE OR REGISTER, CEILING
ER
SG
EG
CONTRACT FURNISHEDCFCI
CFM
CH
CUBIC FEET PER MINUTE
CHILLED WATER
CONTRACTOR INSTALL
EXHAUST AIREA
FD
FCU FAN COIL UNIT
FLOOR DRAIN, FIRE DAMPER
RG REFRIGERANT GAS
RL REFRIGERANT LIQUID
VD VOLUME DAMPER
REMOVAL WORK
RELOCATION WORK
POINT OF CONNECTION
EXISTING WORK TO REMAIN(E)
NOT IN CONTRACTNIC
G-005
L E
G E
N D A
B B
R E
V
IA
T
IO
N S
D
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
Y I, S
C
C P B
O N
IF
A S
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
O R
E A
F E
W
A
P R
CTV OVERHAED CATV LINE
PHOTOCELL [1PH,120VAC, 1KW(MAX)]
DOMESTIC HOT WATER HEATER (UNDER MECH ITEM)EWH
UNDERGROUND TELEPHONE LINE POLE
INTERIOR
MINIMUM OR MINUTEMIN
J
P
WIRING
POWER AUXILIARY
SAFETY SWITCH
STUBBED-OUT WITH CAP
PULL BOX
FLEXIBLE CONDUIT W/CONNECTORS
CONDUIT UP AND DOWN
CONTROL CIRCUIT
TELEPHONE/DATA CIRCUIT
FOR LIGHTING, POWER & AUXILIARY CIRCUIT
WIRING EXPOSED
FOR LIGHTING, POWER & AUXILIARY CIRCUIT
WIRING CONCEALED IN CEILING, WALL & FLOOR
DENOTES +1350 ABOVE FINISHED FLOOR OR GRADE
19diax3000mmLG W/WELDING CONNECTION
GROUND ROD, COPPER CLAD STEEL
JUNCTION BOX WITH BOX COVER
EXH FAN (UNDER MECH ITEM)
GREEN PILOT LAMP
MANUAL MOTOR STARTER, W/ON-OFF SW
M
REMOVAL EXIST
TELEPHONE OUTLET, SINGLE MODULAR JACK, CAT-6,
8-PIN (RJ45 TYPE) FOR TEL
PANELBOARD OR LOADCENTER
MAGNETIC MOTOR STARTER
FOR REFRIGERATOR
SINGLE RECEPTACLE, 2P-3W-20A-125V, GND TYPE
FOR MICROWAVE
SINGLE RECEPTACLE, 2P-3W-20A-125V, GND TYPE
2P-3W-20A-125V
GROUND FAULT PROTECTED DUPLEX RECEPTACLE,
GROUNDING TYPE
EXISTREMOVAL
S
S3 TOGGLE SWITCH, 3WAY-15A-125V
TOGGLE SWITCH, 1POLE-15A-125V S
S3
EXIT LIGHT, SINGLE FACE WALL MOUNTED
HIGH PRESSURE SODIUM LIGHT, WALL MOUNTED,
FLUORESCENT LIGHT FIXTURE, CEILING RECESSED,
FLUORESCENT LIGHT FIXTURE, WALL MOUNTED,
FLUORESCENT LIGHT FIXTURE,
NEWNEWNEWEXISTREMOVAL
EF
UH UNIT HEATER (UNDER MECH ITEM)
PUMP (UNDER MECH ITEM)
S
LIGHTING
DESCRIPTION DESCRIPTION
EXTERIOR
L E G E N D
NORMALLY CLOSED
NORMALLY OPEN
TOXIC FREE AREA
KILO VOLT AMPERE
LIGHTNING ARRESTER
GROUND FAULT PROTECTION
UNDERGROUND
WEATHERPROOF
P
T
C
XFMR
W/
TRANSFORMER
WITH
AND
V
VA
WP
W
TFA
U/G
VOLT
VOLT AMPERE
WATT
+1350
J
REQUIREDREQ'D
STD
SW
TEL
SPEC
SEC
STANDARD
SWITCH
TELEPHONE
SECONDARY
SPECIFICATION
Q'TY
RCPT
GFP
PNLBD
PWR
PRIM
QUANTITY
RECEPTACLE
POWER
PRIMARY
PANELBOARD
N.O.
N.C.
O/H
PH
NO
MTG
OVERHEAD
PHASE
NUMBER
MOUNTING
MAG
MAX
LTG
KV
LA
KVA
MAGNETIC
MAXIMUM
LIGHTING
KILO VOLT
KILO CIRCULAR MIL
ALTERNATING CURRENT
CIRCUIT BREAKER
BARE COPPER
AMERICAN WIRE GAUGE
AMPERE FRAME/AMPERE TRIP
CURRENT TRANSFORMER
HORSE POWER
INCANDESCENT
JUNCTION BOX
ABBREVIATION
DESCRIPTION
FLUORESCENTFLUOR
INSTL
KCMIL
J-BOX
K
INCAND
HZ
INSTALLATION
KILO
HERTZ
FXTR
GND GROUND
FIXTURE
DRAWING(S)DWG(S)
EXIST
ENCL
EA
EM
EXISTING
EMERGENCY
ENCLOSURE
EACH
DIST
DISC
DET(S)
CONN
CT
DISCONNECT
DISTRIBUTION
DETAIL(S)
CONNECTION
AWG
C
CKT
CB
BLDG
BRKR
BC
CONDUIT
CIRCUIT
BUILDING
BREAKER
AF/AT
A
AC
AMPERE
HP
M
R
F
NEWREMOVAL EXIST
STUB-OUT
UNDERGROUND SECONDARY LINE
UNDERGROUND PRIMARY LINE
DESCRIPTION REMOVAL
PAD MOUNTED TRANSFORMER
CONCRETE ENCASEMENT DUCT
NEWEXIST DESCRIPTION NEWREMOVAL EXIST DESCRIPTION
ABOVE FINISHED FLOORAFF
OVERHEAD SECONDARY LINE
S
SINGLE RECEPTACLE, 2P-3W-20A-125V, GROUNDING TYPE
EWH
FLUORESCENT LIGHT FIXTURE,
FLUORESCENT LIGHT FIXTURE,
RATED WATT ON LTG SCHEDULE
3-POSITION SEL SWITCH(H-O-A)
COMBINATIONCOMB
RATED WATT & TYPE OF MTG ON LTG SCHEDULE
RATED WATT & TYPE OF MTG ON LTG SCHEDULE
RATED WATT & TYPE OF MTG ON LTG SCHEDULE
RATED WATT & TYPE OF MTG ON LTG SCHEDULE
RATED WATT & TYPE OF MTG ON LTG SCHEDULE
FLUORESCENT LIGHT FIXTURE, RATED WATT & TYPE OF MTG
ON LTG SCHEDULE W/EMERGENCY BATTERY & SUPPLY UNIT
EXTERIOR LIGHTS & POLE
OVERHEAD CONTROL LINE
QUAD-PLEX RECEPTACLE, 2P-3W-20A-125V,
GROUNDING TYPE
8-PIN (RJ45 TYPE) FOR TEL/DATA
TELEPHONE OUTLET, DUAL MODULAR JACK, CAT-6,
COMB MAGNETIC MOTOR STARTER
TELEPHONE MANHOLEC
SINGLE DOWNGUY
MANUAL TRANSFER SWITCH (MTS)
GROUNDING TYPE, W/PLUG30
SINGLE RECEPTACLE, 3P-4W-30A-125/250V,
DUPLEX RECEPTACLE, 2P-3W-20A-125V,
MTS
AIR COMPRESSOR (UNDER MECH ITEM)
A/C SPLIT AIR CONDENSING UNIT (UNDER MECH ITEM)
HPU SPLIT SYSTEM HEAT PUMP UNIT (UNDER MECH ITEM)
(UNDER MECH ITEM)
OHPU
OUTDOOR SPLIT SYSTEM HEAT PUMP UNIT
BUILT-IN CONTROLLER
J
HOMERUN CIRCUIT TO PANELBOARD
SINGLE RECEPTACLE, 2P-3W-20A-250V, GND TYPE
UH
HEATING & VENT UNIT (UNDER MECH ITEM)H/V
H-FRAME POLE MOUNTED TRANSFORMER
AC
ENCLOSURE CIRCUIT BREAKER
S CEILING MOUNT DUAL OCCUPANCY SENSOR SWITCH
Sos WALL MOUNT OCCUPANCY SENSOR SWITCH
D
SURGE SUPPRESSION TYPE DUPLEX RECEPTACLE
WHM WATT HOUR METER
2P-3W-20A-125V
EXPLOSION PROOFEP
P
ACU
S
GREEN PILOT LAMP
MANUAL MOTOR STARTER, W/3-POSITION SEL. SE.(H-O-A)
L
L
S MOMENTARY CONTACTOR SWITCH
"EP"TYPE, EMERGENCY LIGHT UNIT, WALL MOUNTEDEP
SCHEDULE, W/EMERGENCY BATTERY AND SUPPLY UNIT
LED LIGHT FIXTURE, RATED WATT & TYPE OF MTG ON LTG
LED LIGHT FIXTURE, RATED WATT & TYPE OF MTG ON LTG
L
L
SCHEDULE
SCHEDULE, W/EMERGENCY BATTERY AND SUPPLY UNIT
LED LIGHT FIXTURE, RATED WATT & TYPE OF MTG ON LTG
LED LIGHT FIXTURE, RATED WATT & TYPE OF MTG ON LTG
SCHEDULE
L
LED LIGHT FIXTURE, RATED WATT & TYPE OF MTG ON LTG
SCHEDULE
FLUORESCENT LIGHT FIXTURE,
RATED WATT & TYPE OF MTG ON LTG SCHEDULE
EP
LED LIGHT FIXTURE, RATED WATT & TYPE OF MTG ON LTG
SCHEDULE
"EP"TYPE, METAL HALIDE LIGHTS, RATED WATT ON LTG
SCHEDULE
ELECTRICAL HANDHOLEH
ELECTRICAL MANHOLEM
H
M
H
M
L
SCHEDULE, W/EMERGENCY BATTERY AND SUPPLY UNIT
LED LIGHT FIXTURE, RATED WATT & TYPE OF MTG ON LTG
LED LIGHT FIXTURE, RATED WATT & TYPE OF MTG ON LTG
SCHEDULE
L
L
L E
G E
N D A
N D A
B B
R E
V
IA
T
IO
N S
SECONDARY RACK AND ENTRANCE CAP
G-006
C
D
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D a te
P ro je c t n o
S u b m it te d b y
D ra w in g n o
R e v ie w e d b y D
A T
E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
U s in g A g e n c y
S a fe ty O ff ic e r
B ld g s
G ro u n d s
U ti li ti e s
F ir e P re v P ro t
In s p e c ti o n
O th e rs
R e v
D a te
IN
S
T A
L L
A T
IO
N M
A N
A G
E M
E N
T
C O
M M
A N
D -P
A C
IF
IC
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION
IMCOM-Pacific
UNIT 15742, APO AP 96205-5742
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U N
IT
A P
O A
P
-5
U S A
R M
Y G
A R
R
IS
O N R
E D C
L O
U D
Y I, S
C
C P B
O N
IF
A S
T R
A N
S C
E
IV
E R W
IT
H N
E W I
N C
L U
D
IN
G R
E P
A
IR
S -1
R
E P
L A
C E F
IR
E A
L A
R M B
U
IL
D
O R
E A
F E
W
A
P R
E
N E
R A
L N
O T
E S -1
SEPARATE GROUNDING CONDUCTORS SHALL BE PROVIDED FOR ELECTRICAL
EQUIPMENT AND RECEPTACLES UNLESS OTHERWISE INDICATED ON THE DRAWING.
STEEL CONDUIT.
TO PENETRATING CONCRETE SLAB.
THE CONDUIT SHALL BE INSTALLED 1219mm BELOW GRADE.
INDICATES 5#12 AWG & 1#12(G) IN 21C
INDICATES 4#12 AWG & 1#12(G) IN 16C
INDICATES 3#12 AWG & 1#12(G) IN 16C
UNLESS OTHERWISE INDICATED ON THE DRAWING.
ALL CONDUITS FOR INTERIOR ELECTRICAL WIRES SHALL BE RIGID STEEL CONDUIT
ALL UNDERGROUND CONDUITS UNDER PAVED ROAD SHALL BE ENCASED WITH
ALL ELECTRICAL MATERIAL AND WORKMANSHIP SHALL COMPLY WITH ALL THE
REQUIREMENTS OF NATIONAL ELECTRICAL CODE 2017 EDITION AND NATIONAL
ELECTRICAL SAFETY CODE IEEE-2017.
ENERGY EFFICIENT FLUORESCENT LIGHTING FIXTURES SHALL BE UTILIZED FOR
MOST INTERIOR SPACES. 1200mm(4 FEET) FULL SIZE LINEAR FLUORESCENT
LIGHTING FIXTURES SHALL BE EQUIPPED WITH ENERGY SAVING LAMP(S)
INDICATES 6#12 AWG & 1#12(G) IN 21C
THE GOVERNMENT RESERVES THE RIGHT TO POSTPONE THE REQUESTED POWER
MINIMUM OF 14 DAYS PRIOR TO THE ANY SCHEDULED POWER OUTAGE.
THE CONTRACTOR SHALL NOTIFY CONTRACTING OFFICE, AND DPW IN WRITING A
OUTAGE UP TO 8 HOURS PRIOR TO REQUESTED POWER OUTAGE.
FINISHED STATE PER NEC 300.23 AND 314.29
BE ACCESSIBLE TO AUTHORIZED PERSONNEL DURING FINAL INSPECTION IN
ALL ELECTRICAL JUNCTION BOXES, PULL BOXES, WIRING TRAYS, AND etc. SHALL
GENERAL NOTES
ANY NEW CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES 2#12AWG WIRES
A GREATER NUMBER OF WIRES ARE INDICATED AS FOLLOWS:
AND 1#12(G) IN 16C
A-1.
ALL MEASUREMENTS ARE METRIC "mm" UNLESS OTHERWISE INDICATED ON
CONCRETE UNLESS OTHERWISE INDICATED ON THE DRAWING.
ANY PENETRATING AND PASSING THROUGH BLDG CONCRETE SLAB SHALL BE RIGID
ALL UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC CONDUITS EXCEPT
USE OF RIGID STEEL CONDUIT SHALL BE ALSO USED WITHIN 1500mm PRIOR 28WATT(T-5) WITH A MINIMUM CRI OF 70 AND 3500K.
SHALL BE APPROVED BY THE CONTRACTING OFFICE.
REQUIRED WIRING AND OVER CURRENT PROTECTION DEVICES. THE CHANGES
THEN THE CONTRACTOR SHALL BE RESPONSIBLE TO RESIZE AND PROVIDE THE
IF EQUIPMENT OTHER THAN INDICATED ON THE PLANS ARE PROVIDED,
FOLLOWS UNLESS OTHERWISE NOTED ON THE DRAWINGS.
MOUNTING HEIGHTS ABOVE THE FINISHED FLOOR SHALL BE AS
TEL CABINET
LIGHT FIXTURE
RCPT, TEL OUTLET
MOTOR CONTROLLER
SAFETY SWITCH
WALL SWITCH
PANELBOARD 1976 mm (6-FEET 6-INCH) TO THE HIGHEST HANDLE
1219mm (4-FEET) TO THE BOTTOM OF ENCL.
457mm (18-INCH) TO THE BOTTOM OF ENCL.
304mm (1-FEET) TO BOTTOM OF THE CABINET.
1524mm (5-FEET) TO CENTER OF THE ENCL.
1524mm (5-FEET) TO CENTER OF THE ENCL.
SEE LIGHTING FIXTURE SCHEDULE
OF CIRCUIT BREAKER OF PANELBOARD (MAXIMUM).
DURING THE CONSTRUCTION WHEN CONTRACTOR FOUND UNKNOWN EXISTING
RELOCATION WORK SHALL BE COORDINATED WITH DPW AND ELEC UTILITY SHOP.
UNDERGROUND POWER CABLES IN THE PROJECT SITE, ANY REMOVAL OR
FIRESTOPPED.
ALL CONDUIT AND CONDUCTORS PENETRATING FIRE RATED WALLS SHALL BE
CONTRACTOR SHALL VERIFY ELECTRICAL REQUIREMENT OF EQUIPMENT PRIOR TO
INSTALLING THE ASSOCIATED CIRCUIT BREAKER, CONDUIT & WIRING.
A-2.
A-3.
A-4.
A-5.
A-6.
A-7.
A-8.
A-9.
B-1.
C-1.
D-2.
D-3.
D-4.
A. GENERAL SYSTEM
B. GROUNDING SYSTEM
C. LIGHTING SYSTEM
D. POWER SYSTEM
THE DRAWING.
OR 152mm(6-INCH) FROM THE CEILING WHICHEVER
COMB (FA + MNS) VISUAL
SIGNAL STROBE
2032mm (6-FEET 8-INCH) TO BOTTOM OF DEVICE.
IS LOWER.
IS LOWER.
2032mm (6-FEET 8-INCH) TO BOTTOM OF DEVICE.
FIRE ALARM/MASS
NOTIFICATION SPEAKER
2286mm (7-FEET 6-INCH) TO TOP OF DEVICE.
IS LOWER. OR ON CEILING.
CONTROL PANEL
MASS NOTIFICATION
1220mm (4-FEET) TO TOP OF DEVICE.
VISUAL SIGNAL STROBE
SPEAKER/COMB (FA + MNS)
MANUAL PULL STATION
COMB FIRE ALARM &
OR 152mm(6-INCH) FROM THE CEILING WHICHEVER
OR 152mm(6-INCH) FROM THE CEILING WHICHEVER
1676mm (5-FEET 6-INCH) TO CENTER OF THE ENCL.
ROOM NUMBER PER CIRCUIT AFTER COMPLETE INSTALLATION.
THE CONTRACTOR SHALL PROVIDE EACH PANELBOARD SCHEDULE SHOWINGD-7.
THE CONTRACTOR SHALL SUBMIT A SHOP DRAWING OF HVAC SYSTEM IN ACCORDANCE
WITH SEQUENCE OF OPERATION ON THE MECHANICAL DRAWINGS.
FOR ANY CONTROL WIRINGS AND DEVICE LOCATIONS, SEE MECHANICAL DRAWINGS.
ALL EQUIPMENT CONTROL WIRING SHALL BE #14 AWG "TW" IN 16C UNLESS OTHERWISE
INDICATED.
D-8.
D-9.
REMOVAL OF EXISTING ELECTRICAL DISTRIBUTION SYSTEM EQUIPMENT SHALL
INCLUDE EQUIPMENT'S ASSOCIATED CONDUCTORS,EXPOSED CONDUIT, SURFACE
METAL RACEWAYS, BOXES, AND FITTINGS, BACK TO EQUIPMENT'S POWER
SOURCE IF POSSIBLE.
D-1.
EXCAVATION.
THE GRADING LINE OF NEW DUCTS WILL BE LIMITED TO THE WIDTH OF DUCT
AFTER INSTALLATION OF ELECTRICAL SYSTEM.
INCLUDING SODDING, UTILITIES, STRUCTURES, ANY INTERIOR & EXTERIOR
THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED AREA
WALLS/FLOORS TO THEIR ORIGINAL CONDITION AND OPERATION DURING AND
A-11.
PROVIDE ARC FLASH WARNING LABELS ON ELECTRICAL EQUIPMENT LIKELY TO
PROVIDE LABELS IN ACCORDANCE WITH THE FORMAT SHOWN IN FIGURE BELOW.
REQUIRE EXAMINATION, SERVICING OR MAINTENANCE WHILE ENERGIZED.
D-5.
SHOCK, ARC FLASH, AND ARC BLAST HAZARD APPROPRIATE
INJURY OR DEATH.
PPE REQUIRED FAILURE TO COMLPLY CAN RESULT IN
WARNING!
REFER TO UFC 3-560-01
OR WALL. CONDUITS ON CONC SLABS SHALL NOT BE OVERLAPPED.
CONDUITS LARGER THAN 27mm(1") SHALL NOT BE INSTALLED IN CONC FLOOR
TO BE EMBEDED IN CONCRETE FLOOR SLAB.
ELECTRICAL CONDUITS SIZES 27mm(1") DIAMETER OR SMALLER ARE ALLOWEDA-10.
CONDUITS EMBEDDED IN CONCRETE WALLS AND FLOORS SHALL NOT HAVE
MORE THAN TWO(2) 90 DEGREE BENDS BETWEEN PULL BOXES.
ENTRY CONDUITS SHALL EXTEND BETWEEN FOUR TO SIX INCHES ABOVE THE
FINISHED FLOOR TO AID IN PULLING CABLES AND SHALL BE PLACED WITHIN
THREE INCHES OF THE WALL.
A-15.
RE-ENTERABLE FIRSTOPPING DEVICES (S) CONTAINING SELF-SEALING
COMMUNICATION WIRING OR CABLE SHALL BE THROUGH MODULAR,
PENETRATIONS OF FIRE-RATED PARTITIONS, WALLS OR FLOORS BY DATA/
INTUMESCENT AND MAINTAIN AN AIR LEAKAGE RATING OF <5 CFM/SF
[MEASURED AT AMBIENT AIR TEMPERATURE AND 205 DEGREES C (400
DEGREES F)] AT 0 TO 100 PERCENT VISUAL FILL PER SPECIFICATION
SECTION 07 84 00 (FIRE STOPPING).
CONTRACTOR SHALL INSTALL ALL ELECTRICAL WALL BOXES FLUSH OR RECESSED .A-16.
A-17.
FOR FLUSH-MOUNTED PANELBOARDS, PROVIDE SPACE CONDUITS EXTENDING UP ABOVE
PROVIDE A MINIMUM OF 20% EMPTY SPACE FOR ALL PANELBOARDS.
THE CEILING AND DOWN BELOW RAISED FLOORS WHEN APPLICABLE.
PROVIDE ONE CONDUIT, MINIMUM OF 3/4 INCH, FOR EVERT THREE EMPTY SPACE.
D-6.
AFTER COMPLETE INSTALLATION OF THE INTERIOR ELECTRICAL SYSTEM, INSPECT THE
SYSTEM VISUALLY AND PERFORM THE TEST OF EACH ELECTRICAL SYSTEM AND
ITS MAJOR EQUIPMENT. THEN PROVIDE THE TESTING RESULTS WITH AT LEAST A COUPLE
OF A4 SIZE PAPER BRIEFLY TO THE DPW OR USING AGENCY.
CIRCUIT BREAKER & RELAY SETTINGS AND GROUND FAULT PROTECTION IN THE
MAIN SWITCHBOARD, etc.
THE TEST SHALL INCLUDE THE OPERATION OF SYSTEM, INSULATION OF MAIN FEEDERS,
D-11.
AFTER COMPLETE INSTALLATION OF THE EXTERIOR ELECTRICAL SYSTEM, INSPECT THE
SYSTEM VISUALLY AND PERFORM THE TEST OF UNDERGROUND ELECTRICAL SYSTEM AND
ITS MAJOR POWER EQUIPMENT. THEN PROVIDE THE TESTING RESULTS WITH AT LEAST A
COUPLE OF A4 SIZE PAPER BRIEFLY TO THE DPW OR USING AGENCY.
UNDERGROUND CABLES, FUSE OR BREAKER SETTINGS IN THE SWITCHGEAR,
THE TEST SHALL INCLUDE THE OPERATION OF SYSTEM, INSULATION OF
D-12.
RELAY SETTINGS ON THE POWER DISTRIBUTION LINES, etc.
FOR FLUORESCENT LIGHTING FIXTURE, PROVIDE DOUBLE-ENDED LAMPS AND
INTERNAL OR EXTERNAL DISCONNECT SWITCH TO MEET THE REQUIREMENT OF
NEC 410. 130 (G).
C-2
GROUNDING AND BONDING.
CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF I3A,
ANSI-J-S TD-607-B, MIL-STD-188-124B AND MIL-HDBK-419A FOR
EFFECT.
CABLING TYPES, TERMINATION POINTS, AND USE OF COMBINED PATCHING IS IN
DESIGN CRITERIA WILL OVERRIDE THE I3A INSTRUCTION WHERE CONFLICT OF
DOD UNIFIED CAPABILITIES REQUIREMENTS CHANGE 3 AND OCONUS TECHNICAL
B-2.
-. ROD AND PIPE ELECTRODES
-. OTHER LOCAL METAL UNDERGROUND SYSTEMS OR STRUCTURES.
-. GROUNDING RING
-. CONCRETE ENCASED ELECTRODE
-. METAL UNDERGROUND WATER PIPE
-. METAL FRAME OF THE BUILDING OR STRUCTURE
LISTED BELOW AT THE BUILDING OR STRUCTURE SHALL BE BONDED TOGETHER
IN ACCORDANCE WITH 2017 NEC ARTICLE 250 ALL GROUNDING ELECTRODES
RESISTANCE.
ADDITIONAL GROUND RODS SHALL BE ADDED TO OBTAIN THE REQUIRED SOIL
SHALL BE 25 OHMS OR LESS.
THE SOIL RESISTANCE TO GROUND FOR THE ELECTRODE GROUNDING SYSTEM
UNLESS OTHER WISE INDICATED ON THE DRAWINGS.
B-3.
CONTRACTOR SHALL PROVIDE 90 DEGREE RATED WIRE OR WIRE TYPE RECOMMENDED
THE DRAWING
BY MANUFACTURER FOR EQUIPMENT BELOW UNLESS OTHERWIRE INDICATED ON
D-10.
-. POWER FILTERS
-. HID LIGHT FIXTURES
-. DRY TYPE TRANSFORMER
-. MECHANICAL EQUIPMENTS SUCH AS FAN & MOTOR
G-007
D
2 3
C
4 5
A
B
NUMBER
IDENTIFICATION
SHEET
S E
T
ID
S c a le
A p p ro v e d b y
D w n b y
C k d b y
D e s ig n e d b y
D…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.