TE 3_Safety and Load Test Report_ENG.pdf
PDF 184 KB Posted
- Attached to
- Hoist and Crane Federal contract opportunity
- Solicitation number
- W90VN7-24-Q-A007
- Issued by
- Department of the Army
About this file
This document contains a safety and load test report template for hoists and cranes. The template requires information on the customer, crane details including location, structure specifications, operating capacity and inspection results. Inspection items cover components like the girder, rail, wheel, brake, drum, wire rope, hook and safety equipment. Tests include a running test with rated load for functions like hoisting, traveling and turning. Acceptance criteria specify pass/fail standards for critical items.
The related federal contract opportunity is a solicitation from the Department of the Army for safety inspection and load testing of hoists and cranes. The solicitation references an attached performance work statement and has a number W90VN7-24-Q-A007 for a hoist and crane requirement.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment W90VN724QA0070002 SF 30.pdf | ||
| PWS Hoist and Crane V2.pdf | ||
| Solicitation Amendment W90VN724QA0070001 SF 30.pdf | ||
| TE 2 Hoist and Cranes on Kunsan AB.pdf | ||
| RFQ 24QA007.pdf | ||
| PWS Hoist and Crane.pdf | ||
| TE 1 Hoist and Cranes on Kunsan AB.pdf | ||
| Solicitation Amendment W90VN724QA0070001 SF 30.pdf | ||
| PWS Hoist and Crane.pdf | ||
| TE 1 Hoist and Cranes on Kunsan AB.pdf | ||
| RFQ 24QA007.pdf | ||
| TE 3_Safety and Load Test Report_ENG.pdf | ||
| TE 2 Hoist and Cranes on Kunsan AB.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SAFETY & LOAD TEST REPORT
CUSTOMER
MODEL
CONTROL
NUMBER
MFR
MANUFACTURED
DATE
TYPE
□ GANTRY (GANTRY, SEMI GANTRY) CRANE □ OVERHEAD CRANE
LOCATION
□ HOIST (MONO RAIL, DOUBLE RAIL, FIX) □ OTHER □ INDOOR □ OUTDOOR
STRUCTURE'S SPEC, SIZE AND TYPE
□ SPAN □ LIFT □ GIRDER TYPE
□ OPERATING
RATED
CAPACITY
ACCEPTANCE □ PASS INSP DATE
INSPECTOR
□ FAIL VALID BY
INSPECTION & TEST ITEMS
# LIST
INSP
# LIST
INSP
# LIST
INSP
# LIST
INSP
# LIST
INSP
P N/A P N/A P N/A P N/A P N/A
1 GIRDER/SADDLE 11 BEARING 21 WIRE ROPE 31 CONTROLLER 41 ER STOP DEVICE
2 RAIL 12 WHEEL 22 CHAIN 32 PENDANT SW 42 OL PROTECTION
3 RAIL FAS BOLT 13 MOTOR 23 HOOK, BLOCK 33 REMOTE CON 43 COL PROTECT
4 STOPPING DEVICE 14 COUPLING 24 OPERATING CABIN 34 RESISTER 44 HOOK UNLOCK DEV
5 SLIPPING PRE EQ 15 BRAKE 25 TRAVELING MOT 35 TROLLEY BAR 45 MOVING PARTS
6 MOT FIX BASE 16 WHEEL GEAR 26 NAME PLATE 36 WIRING 46 LOAD TEST
7 COUPLING 17 SHAFT 27 LUBR COCK 37 LIGHTING
8 BREAK 18 BEARING 28 LUBR PUMP 38 LIF MAGNET
9 WHEEL GEAR 19 DRUM 29 MOTOR 39 GROUNDING
10 SHAFT 20 SHEAVE 30 CONT PANEL 40 LIMIT SWITCH
INSPEC : INSPECTION, P : PERFORMED, N/A : NOT APPLICABLE, FAS : FASTEN, PRE : PREVENT, EQ : EQUIPMENT, MOT : MOTOR, DEV : DEVICE
LUBR : LUBRICANT, CONT : CONTROL, SW : SWITCH, LIF : LIFTING, ER : EMERGENCY, OL : OVERLOAD, PRO : PROTECTOR, COL : COLLISION
ROT : ROTATOR
CRITICAL ITEMS
NO LIST ACCEPTANCE STANDARD
RESULT INSP
METHOD
INSP RESULT
USED
EQUIPMENT
PA FA
1 GIRDER & SADDLE Girder and saddles are not in worn, cracked or distorted status.
2 STOPPING DEVICES Stopping Devices for traveling are not in worn, cracked, fallen off or distorted condition.
SLIPPING PREVENTION
DEVICES
Crane installed outdoor must be equipped with stopping devices and not in worn, cracked, damage or fallen apart.
WHEEL
Flanges are not in any cracked, distorted or damaged. Abrasin of the flanges are within 50% of original size.
Boss and web of wheels are not in any crack, deformed or damaged.
BRAKE
Works smoothly without abnormal noise or odor.
Lining has no wear and tear and loss of abrasion is less than 50% of original size
Disc is not in any damaged or cracked status and loss of abrasion is less than 10% of original size
6 DRUM Drum is not cracked, worn or distorted.
WIRE ROPE AND
CHAIN
Wirerope must be the 1 continuous integrated part and no joints. NOMIN DIAMETER
Element of wire rope at the end must not be cut, corroded, kinked or damaged. Fastening of wire rope is not loosen, damaged or fallen off.
When the hook is located at the lowest position, the remaining length of wire rope should be more than 2 turns of the drum.
MEASURED
DIAMETER
Chain shall not be in cracked. Elongation rate shall be less than 5% and deformed diameter within 10%
8 HOOK
Hook body is not in cracked, deformed or wear. A portion of abrasin must be within 5% of original measurement.
9 MOTOR Insulation resistance must be over (Voltage / (1000 + output Kw))KΩ
10 LIFTING MAGNET Magnetic contactor must be kept over 10 munities in an emergency power outage.
11 GROUND Ground resistance, Under 400V : Under 100Ω, Over 400V : Under 10Ω
SAFETY EQUIPMENT
Limit switch, Emergency stop device & Overload protection device are in compliance with the local safety standard.
Where two crane are installed in parallel, cranes shall be stopped in the programed distance and alarmed to prevent a collision.
Safety latch of hook must be in proper location and operating.
13 LOAD TEST
Running Test with the rated load, (hoisting up/down, cross running, traveling, turning and etc.)
14 OTHER In a case of natural disaster
PA : PASS, FA : FAIL, INSP : INSPECTION, NTE : NONDISTRUCTIVE TESTING EQUIPMENT
- ACCEPTANCE RESULT : ○ MARKED EACH COLUMN
- INSPECTION METHOD, V : VISUAL INSPECTION, E : INSPECTED BY EQUIPMENT, A : ACTUAL INSPECTION, C : VERIFY TO CERTIFIED ITEM
OTHER ITEMS TO MANAGE (IF NEEDED, USE EXTRA COPY)
NO LIST INSPECTION RESULT (NOT CRITICAL ITEMS) AA
AA : AUTHORITY ARTICLES
OTHER ITEMS ARE NOT PART OF CRITICAL ITEMS WHETHER OR NOT CRANES/HOISTS ARE DETERMINDED TO BE PASSED OR FAILED IN MEETING SAFETY STD.