A
B
7 6 5
C
D
8 7 6 5
4 3 2
THIRD ANGLE
PROJECTION
A
B
4 3 2
C
D
(R )3.6 92[ ]
( )1.7 44[ ]
.75 19,1[ ]
( )2.7 67[ ]
.625 +.010 -.005
15,88 +0,25 -0,12[ ]
11.5�$�
( )11.5�$�
REVISIONS
ZONE REV. DESCRIPTION DATE APPROVED
- INITIAL RELEASE 2017-11-03
SCALE 1.000 WEIGHT 43.927 SHEET 1 OF 1
DEPARTMENT OF THE NAVY
UNITED STATES MARINE CORPS
TITLE
SERVICE CHAMBER,
TYPE 12, 1/4 NPT
PORT MODIFICATION
SIZE
D
CAGEC
01365
DWG NO.
17002C1120
REV.
DRAWN BY
DLT
DATE
2017-01-04
CHECKED BY
ERW
2017-11-03
ENGINEERED BY
DLT
2017-01-04
APPROVED BY
XXX
YYYY-MM-DD
CONTRACT NO.
M67854-12-G-0202
DESIGN ACTIVITY APPROVAL
APPROVED
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
ONE PLACE (X) �#� 0.03
TWO PLACE (XX) �#� 0.02
THREE PLACE (XXX) �#� 0.010
ANGLES �#� 0.5�$�
DO NOT SCALE THIS DRAWING
FOR INTERPRETATION OF DRAWING ASME Y14.100 APPLIES
REMOVE BURRS AND BREAK SHARP EDGES
MATERIAL
N/A
FINISH
SEE DRAWING NOTES
MODIFICATION DRAWING
DISTRIBUTION STATEMENT D -
DISTRIBUTION AUTHORIZED TO DOD AND U.S. DOD CONTRACTORS ONLY;
COMPETITION SENSITIVE. OTHER REQUESTS FOR THIS DOCUMENT SHALL
BE REFERRED TO PROGRAM EXECUTIVE OFFICER LAND SYSTEMS, 2200
LESTER STREET, QUANTICO, VIRGINIA 22134. ATTN: PM M&HTV.
PARTS LIST
FIND
NO.
QTY
CAGE
CODE
SPECIFICATION
PART OR
IDENTIFYING NO.
NOMENCLATURE OR
DESCRIPTION
1 1 01365 17002C1121 SERVICE CHAMBER, TYPE 12
2 1 01365 17002C1130 WELD-ON PORT, 1/4 NPT
17002C1100 17002C1200 17002C0000 17002C2100 17002T0000 17002C2200 17002W0000
NEXT ASSY USED ON
APPLICATION
FOR INTERPRETATION OF DIMENSIONING
AND TOLERANCING SEE ASME Y14.5
NOTES: UNLESS OTHERWISE SPECIFIED
1. REFER TO DRAWING 17002C1121 FOR TECHNICAL INFORMATION FOR
ORIGINAL BRAKE ACTUATOR.
2. PART IDENTIFICATION PER MIL-STD-130. MARK WITH PART NUMBER
"01365-17002C1120".
3. "TYPE" DESIGNATION REFERS TO THE NOMINAL AREA OF PISTON OR
DIAPHRAGM IN SQUARE INCHES, AS DEFINED IN FMVSS 121.
4. WELD IN ACCORDANCE WITH AWS D1.1/D1.1M:2010.
5. INTERNAL BRAKE ACTUATOR COMPONENTS ARE NOT SHOWN.
MODIFICATION INSTRUCTIONS:
6. REMOVE BAND CLAMP AND SEPARATE PRESSURE CHAMBER (PC) FROM
NON-PRESSURE CHAMBER (NPC). REMOVE BRAKE CHAMBER DIAPHRAGM AND
RETAIN COMPONENTS.
7. REMOVE INTERNAL RUBBER BOOT AND RETAINING RING FROM NPC AND DISCARD.
8. REMOVE COLLET NUT AND RETAIN.
9. REMOVE PLASTIC TUBE THREAD CAP AND RUBBER PLUGS FROM NPC AND DISCARD
(IF PRESENT).
10. REMOVE FINISH FROM NPC. SUGGESTED PROCESS: ABRASIVE BLASTING
IN ACCORDANCE WITH MIL-DTL-53072E.
11. PLUG WELD FOUR �n�.28 HOLES SHUT.
SUGGESTED PROCESS: GTAW
SUGGESTED FILLER METAL: AWS ER70S-2
12. DRILL HOLE FOR VENT PORT. INDICATED POINT MARKS HOLE CENTER.
POINT LIES ON SURFACE OF NPC. PLACEMENT OF THE WELD-ON PORT SHALL
BE BETWEEN THE TOOLING MARKS ON NPC.
13. WELD VENT PORT TO NPC.
SUGGESTED PROCESS: GTAW
SUGGESTED FILLER METAL: AWS ER70S-2
14. INSPECT PRESSURE CHAMBER. IF COATING IS DAMAGED, OR IF PRESSURE
CHAMBER IS UNCOATED, CLEAN AND PRIME ACCORDING TO MIL-DTL-53072E.
15. CONFIRM THAT MODIFIED BRAKE CHAMBER CAN ACHIEVE FULL PISTON STROKE BY
ENSURING THAT NO PART OF WELDED FITTING PROTRUDES INTO INTERIOR VOLUME
OF BRAKE CHAMBER.
16. REASSEMBLE COMPONENTS IN REVERSE ORDER OF DISASSEMBLY.
TORQUE FOR BAND CLAMP BOLT:
5/16-24 BOLT, GRADE 8: 18-23 FT-LB
3/8-16 BOLT, GRADE 8: 30-35 FT-LB
REPLACE BAND CLAMP BOLT IF BOLT EXHIBITS SIGNS OF DAMAGE.
17. MASK INTERNAL THREADS. PRIME AND FINISH COAT ASSEMBLY WITH CARC
IN ACCORDANCE WITH MIL-DTL-53072E. SUGGESTED COLOR PER FED-STD-595:
GREEN 383, CHIP NUMBER 34094. DIMENSIONS SHOWN APPLY PRIOR TO COATING.
18. CONFIRM AIR-TIGHT WELD AND BAND CLAMP SEAL BY SUBJECTING NPC TO A
MINIMUM OF 5 PSI AIR PRESSURE AND MAXIMUM OF 15 PSI FOR AT LEAST 2
MINUTES. WHILE NPC IS PRESSURIZED, SPRAY WELD AND BAND CLAMP INTERFACE
WITH A SOAP AND WATER SOLUTION AND VISUALLY INSPECT FOR EVIDENCE OF
BUBBLES CAUSED BY AIR LEAKS. PERFORM THIS STEP AFTER BRAKE CHAMBER
REASSEMBLY AND FINISH COAT.
SECTION A-A
SEE DETAIL A
NOTE 8
DETAIL A
SCALE 2.000
NOTE 12
NOTE 11
(TYP. 4 LOCATIONS )
NOTE 13
.13
Distribution ChangeZ01A8 2018-1-24
Distribution Statement A:
Approved for publi release: Distribution is unlimited Z01
| Sheet 1 |
| Views |
| new_view_20 |
| new_view_18 |
| top_19 |
| A |
File details come from the government source that posted it.