MAINTENANCE ENGINEERING ORDER
(AMCOM Reg. 750-2)
MEO NO.
DATE PAGE 1 of
TITLE Tolerances Unless otherwise noted, dimensions are in inches and tolerances are:
Fractional ………………… ± 1/32 Decimal ………………... ± 0.010 Angular ………………… ± ½°
APPLICABILITY CSI Critical Characteristic Affected?
Impact Statement Attached?
REFERENCES FOR RDECOM USE ONLY
DOCUMENT(S) AFFECTED
PURPOSE OR PROBLEM
PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE
MED FORM 15-DEC-09 1401-R-E
D 1188
Mar 5, 2014 1
Technical clarification for Power Transfer Unit (PTU), Hydraulic Motor/Pump P/Ns 569774 (145HS140-8), 569775 (145HS140-9), and
569776 (145HS140-10)
Administrative
INTERIM USE OF THIS MEO IS AUTHORIZED
UNTIL AFFECTED DOCUMENT IS UPDATED.
MEO CHANGE TYPE
4) Normal - Can be implemented with normal priorityPRIORITY IMPLEMENTATION CATEGORY
CH47 DAA
DMWR 55-1650-399 (7 JUN 2013) MEC D179313 21 FEB 2014
MEC D179360 21 FEB 2014
DOCUMENT CHANGE IS REQUIRED Verification: Hands-On Table-Top None
Clarified use of adhesive to adhere various data plates to housing.
CASTILLO.NOEL
.SR.1089736990
Digitally signed by
CASTILLO.NOEL.SR.1089736990
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=CASTILLO.NOEL.SR.1089736990 Date: 2014.02.28 15:17:40 -06'00'
CAREL.PAMELA.
KAY.1125864534
Digitally signed by
CAREL.PAMELA.KAY.1125864534
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=CONTRACTOR, cn=CAREL.PAMELA.KAY.1125864534 Date: 2014.02.20 08:50:00 -06'00'
Pamela Carel (Camber Corp)
PETER.ROBERT.
ARTHUR.JR.108
7823942
Digitally signed by
PETER.ROBERT.ARTHUR.JR.1087823942
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=PETER.ROBERT.ARTHUR.JR.108782394 Date: 2014.03.03 11:46:34 -06'00'
Noel Castillo Robert A. Peter, Jr.
PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT
CHANGE OR REVISION TO THE PUBLICATION IDENTIFIED ABOVE.
WP NO. PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGES MUST BE GIVEN)
3-69
3-91
3-24.d.
(7)
3-34.a.
(3)
3-34.a.
(4)
Change last sentence to read:
"Fill screw holes with sealant (Item 25, Appendix C)."
Change paragraph to read:
"If removed, install rotation plate (32) with adhesives (Item 30 or Item 38, Appendix C) so that arrow on plate is directed as shown in Figures 3-22 and 3-23. Fill screw holes with sealant (Item 25, Appendix C)."
Change paragraph to read:
"If removed, install plates (30, 31, 31.1, 31.2, and 31.3) with adhesives (Item 30 or Item 38, Appendix C) so that they are positioned as in Figures 3-22 and 3-23. Fill screw holes with sealant (Item 25, Appendix C)."
MED FORM 1401-R-E 26-AUG-2013
Formatted Cont. Sheet
RDMR-AEM
MEMORANDUM FOR RECORD:
SUBJECT: Impact of AED Maintenance Engineering Order (MEO) on maintenance using ,affecting system:
Enclosed MEO is issued by this office and is provided as part of our Technical Data user support mission.
4. THIS MEO CHANGES THE FOLLOWING (Check all that apply):
1.
Consumables
Materials
Expendables
Repairable Bill of Materials (RBOM)Impact
3. PRIORITY IMPLEMENTATION CATEGORY :
6. Comments:
7. Point of contact for this action is
2. FOR AMCOM ACQUISITION CENTER USE ONLY:
This MEO was written as a request from a contractor/KO on an active M&O contract.
Request that MEO be transmitted to the contractor as soon as possible.
b.Items checked in this area are considered Normal Priority Implementation Category.
Illustrated Parts Breakdown Change Mandatory Replacement Part
TSO/TSN Change Configuration Change
Publication New Change
Hardware Tooling Equipment
New/Revised Procedure/Process
Process Improvement Project Inspection
Special Process Testing Cost Savings a.Items checked in this area are considered High Priority Implementation Category.
5. Reason(s) MEO Written:
Other
Other
D 1188
DMWR 55-1650-399 (7 JUN 2013) CH47 PTU Pum
D 1188
4) Normal - Can be implemented with normal priority
CCAD Request
To correct portions of DMWR so that they conform to instructions for data plates paragraph 1-6.
Pamela Carel (Camber Corp) 361-961-1651/DSN 861-1651, Noel Castillo at 361-961-1741, (DSN) 861-1741, email:
noel.castillo1.civ@mail.mil.
CASTILLO.NOEL.SR.10897
36990
Digitally signed by CASTILLO.NOEL.SR.1089736990 DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=CASTILLO.NOEL.SR.1089736990 Date: 2014.02.28 15:17:23 -06'00'
Noel Castillo