This document provides specifications for track lighting and mounting systems to be installed at the US Cavalry Museum located at Fort Riley, Kansas. The Army Contracting Command - Detroit Arsenal intends to competitively award a firm fixed price contract for museum fabrication and installation services. The services include preparing shop drawings, fabricating exhibit components, packing, shipping, and installing historic objects and artifacts. The museum is 7,550 square feet divided across two floors, containing 14 exhibit sections and housing approximately 321 artifacts. Lighting specifications cover track components, dimensions, finishes, electrical details, and fixture interface requirements. Mounting system specifications address mechanical and electrical specifications for different mounting options including stems, cables, and clips. Product details are provided for track lighting fixtures, accessories, lamps, and ordering information.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Cavalry Museum Track lighting
LSI Surface track, White Finish w/ LSI SS/238 Series LED PAR38 Fixtures, White finish
8 www.LightingServicesInc.com
SURFACE TRACK (120/250V) • SPECIFICATIONS
GENERAL Lighting Track shall allow fixtures to be located anywhere along the track length. Fixtures shall be easily focused, switched, dimmed, accessorized and removed as desired. Track system shall have a ten year warranty from date of shipment.
MECHANICAL Lighting Track shall be constructed of .070 (2mm) extruded aluminum with overall height of 1.42 (36mm) and overall width of 1.812 (46mm). Track shall have same overall dimensions and physical appearance for both one and two circuit models.
Track shall be available in nominal 4 foot (1.2m), 8 foot (2.4m), and 12 foot (3.7m) lengths, in Silver, Black, White, or Graphite high temperature baked paint finish. Track shall be field cuttable to any length with a single cut.
Track system shall be available with End Feed, End Cap, Straight Mini-Joiner, Straight Joiner/Feeder, Flexible Joiner and L, T, and X Joiner/Feeders as standard components.
Track shall have the ability to be directly surface mounted. Track shall have pre-punched mounting slots for direct mounting to any surface. Track shall have the ability to: be mounted 1/2 inch (13mm) from a surface by extruded aluminum mounting clips, be sus-pended from a surface by a field cuttable stainless steel cable system, be suspended from a surface by a field cuttable steel stem system, and be mounted into UniTrack housing.
ELECTRICAL Lighting Track and components shall be UL and CUL listed, CE Certified, and comply with the National Electric Code standards for Lighting Track. One and two circuit Lighting Track shall be rated at 120/250 volt, 50/60 Hz. 2400 watts maximum each circuit.
Each 20 amp/120 volt circuit shall be comprised of flat copper busbars and have a sepa-rate neutral busbar for each circuit busbar. The neutral busbar shall be oversized to be comparable to #10 gauge 30 amp wire to reduce the possibility of overheating due to non-linear loads and harmonics. Track shall have integral wiring channels for six (6) additional
#12 THHN wires to create three (3) additional 20 amp/120 volt circuits, which can be dropped into any Joiner/Feeder, for a total track power capacity of 100 amps. A separate grounding busbar shall be integral in all track lengths. All busbars shall be insulated to prevent contact with aluminum extrusion.
Track shall have electric feed capability through all Joiner/Feeders (except Flexible Joiner and Straight Mini-Joiner) using either 1/2 or 3/4 U.S. trade size knock-outs (.875 diameter [22mm] or 1.125 diameter [29mm]). Joiner/Feeders can be electrically field modified by removing the Lexan™ cover and rerouting internal pre-wired jumpers. All Joiner/Feeders shall be available in Black, White, Silver, and Graphite GE fiber reinforced LexanTM.
One and two circuit Lighting Track with separate neutral busbars shall have the ability to have each circuit separately dimmed as required when using standard voltage and low voltage fixtures with either magnetic or electronic transformers. Track shall have the abili-ty to be dimmed or switched in selected sections in addition to dimming or switching an entire track configuration or track run.
FIXTURE FITTING INTERFACE Track shall accept GE fiber reinforced Lexan™ fixture fittings which positively lock into track and cannot be energized by the integral switch until safety interlock handle is in the closed position. Safety interlock shall also prevent fixture fitting removal from track unless the switch is in the “off” position. Upon insertion of fixture fitting into track, grounding connection from fixture fitting to track shall be automatically com-pleted before any electrical contact is made with busbars. When removing fixture fitting from track, the grounding connection shall automatically be disconnected last. The fixture fitting shall recess into the track, creating a minimal profile below the track. Fixture fittings for magnetic low voltage fixtures shall be furnished with fuse of the correct ampere rating for integral transformer protection, and shall not be fused as a branch circuit.
One Ckt 120/250V Track
NEUTRAL 1CKT 1
GROUND
1 7/16"
1 13/16"
13/16"
Two Ckt 120/250V Track
CKT 2
NEUTRAL 2NEUTRAL 1
CKT 1
GROUND
1 7/16"
1 13/16"
13/16"
MOUNTING SYSTEMS • SPECIFICATIONS
GENERAL Mounting Systems shall allow Track Systems to be fastened to or from various surfaces in a wide range of safe and approved methods. Mounting Systems shall have a ten year warranty from date of shipment.
MECHANICAL Mounting stems shall be made from .50 (13mm) diameter steel.
All mounting canopies shall be made from either 20 gauge steel (1mm) or .080 (2mm) aluminum. All Mounting Systems shall be available in either Black, White, Silver, or Graphite high temperature baked paint finish.
Mounting stems shall be capable of being cut to length in the field. All hang-straight stems shall have a 30° swivel from plumb in all directions.
All stem systems shall be available in either 18 inch (457mm), 48 inch (1.2m) or 96 inch (2.4m) standard lengths.
All cable systems shall be available in either 18 inch (457mm), 48 inch (1.2m), 96 inch (2.4m), or 144” (3.7m) standard lengths.
Cables shall be constructed of .062 (1.6mm) stainless steel cable and be capable of being cut to length in the field.
Stem and cable mounting systems shall have a safety collar to ensure proper tightening of locking hardware for all field cuttable systems.
Mounting systems shall be capable of being mounted to T-bar ceiling structures either parallel or perpendicular to the T-bar by means of galvanized mounting clips.
ELECTRICAL Mounting Systems shall be UL and CUL listed, CE Certified, and comply with the National Electric Code standards for Lighting Track. Mounting Systems shall have provisions for feeding Track System through feed stems or flexible tubing with a maximum of 5 #12 THHN wires and with Stainless Steel Cable Feed Kit a maximum of 9 #12 THHN wires.
FIXTURE FITTING INTERFACE Mounting Systems used in conjunction with Track shall accept GE fiber reinforced Lexan™ fixture fittings which positively lock into track and cannot be energized by integral switch until safety interlock handle is in closed position. Safety interlock shall also prevent fixture fitting removal from track unless the switch is in the “off” position. Upon insertion of fixture fitting into track, grounding connection from fixture fitting to track shall be automatically completed before any electrical contact is made with busbars. When removing fixture fitting from track, the grounding connection shall automatically be disconnected only after the electrical contact with busbars are disconnected. The fixture fitting shall recess into track creating a minimal intrusion into space. Fixture fittings for magnetic low voltage fixtures shall be furnished with fuse of the correct ampere rating for integral transformer protection, and shall not be fused as a branch circuit.
Surface Hanger Clip
1 5/8"
2"
1/2"
Stainless Steel Cable Support
Canopy Stem Support
5" DIA.
1/2" DIA.
18", 48"& 96"
1"
32 www.LightingServicesInc.com
02/15 www.LightingServicesInc.com
MOUNTING OPTIONS
SSL238-3G
C-clamp for pipes from 5/8” to 2” O.D. With switch, straight 6-foot 3-wire grounding cord and NEMA 5-15P plug.
SSL238-5A
Canopy for permanent mounting on standard 4” octagonal outlet boxes.
SSL238-00
Lexan fitting for 1 and 2 circuit LSI Track. With On/Off switch.
SSL238-BUS
Lexan fitting for 1 and 2 circuit LSI Busway. With On/Off switch.
SSL238-2G
Universal fitting for Unistrut Systems and any screw or bolt-up applications. With switch, straight 6-foot 3-wire grounding cord and NEMA 5-15P plug.
This medium and long throw unit is perfect for areas requiring visually quiet, high intensity light.
• Designed for most PAR38 medium screw base Solid State LED Retrofit lamps up to 20 watts (or up to 150 watt incandescent)
• Sturdy aluminum housing
• Rugged steel self-locking yoke allows for horizontal and vertical focusing
• On/off safety switch (on most mounting types)
• Equipped with beam rotation and relamping handle for easy lamp changing
• Front rotation lock for alignment of directional accessories
• Has beam rotation lock for applications that require positive focus locking
• Internal accessory cartridge holds up to three size C LSI filters and accessories
• Removable cross-baffle eliminates glare (45 degree cutoff)
• Finishes: LSI Black, White, and Silver
• Fixture weight: 1.5 lbs.
Other Options (Consult Factory):
• Stems, specify length (4”- 48”)
• Custom color, RAL palette
• Security/Worklight Fixture, add suffix EF. For use with
–EF00 (Track) and –EFBUS (Busway) mounting options only.
SSL238 SERIES • 120V • LED PAR38
Lighting Services Inc
5 1/8”
5 11/16”
7”
5 3/8”
SSLwww.LightingServicesInc.com • Solid State 02/15
ACCESSORIES
Other accessories:
• Louver C
• Glass Color Filters C
• Spread Lenses C990, C992, C995, C996
• Beam Softener C998
• Backer Ring CB
• Color and Spread Gels CLight Blocking Screens
C801S, C802S, C803S
Stainless steel screens, used to reduce transmitted light without changing its color temperature.
LED PAR38 LAMPS
W SP CCT CBCP
12 20 º 27K 4800 CREE LRP38A92-20D40
12 16º 3K 6750 MSI IPAR3830160
ORDERING INFORMATION
1. Select your Mounting Option.
2. Choose other fixture Options (add suffix):
• For Coiled Cord, add CC
Coiled Cord is 18/3 105ºC, 18” retracted, 6 foot extended. White fixtures are supplied with white cord, all other finishes are supplied with black cord. Available only with 2G and 3G mounting options. (When a coiled cord is not specified, a straight cord is provided.)
• For Wrench Locking, add WL
3. Choose a Finish for your fixture:
Black (B) White (W) Silver (S)
Example: SSL238 —2G CC WL B
FIXTURE FITTING COILED WRENCH FINISH
CORD LOCKING
Blue fields are optional. Leave blank if not required.
4. Don’t forget your Accessories!
LSI features the widest range of accessories in the industry to help you modify the light’s intensity, color, texture and pattern.
4 1/2" 115mm
6 1/8" 155mm
6 1/16" 154mm
8 15/16" 227mm
Lighting Services Inc
02/15 www.LightingServicesInc.com
Lighting Services Inc
SSL238 SERIES • PHOTOMETRIC DATA
20º
CREE 50,000 hrs.
LRP38A92-20DFO 12 watt, Beam spread to 50% of CBCP 20º
Center beamcandlepower 4800
Color temperature (Kelvin) 2700
CRI 94
MSI 50,000 hrs.
IPAR3830160 12 watt, Beam spread to 50% of CBCP 16º
Center beamcandlepower 6750
CRI 83+
16º
A ll
M a x
F o o tc a n d le s a t
B e a m A x is
All Distances in Feet
6 5 4 3 2 1 0 1 2 3 4 5 6
Abbreviations used:
• CBCP = Center Beam Candlepower
MSI IPAR3830160 16o
CREE LRP38A92-20DF0 20o
| US Army Cavalry Museum Track lighting |
| Cav Museum lighting specs |
| 1stID_ReferencePackage 2 |
| 1stID_ReferencePackage 3 |
| 1stID_ReferencePackage 4 |
| 1stID_ReferencePackage 5 |
| 1stID_ReferencePackage 6 |
| Job: Job Name Here |
| Type: Fixture Type Here |
| Designer: Designer/Firm Name Here |
| Order: Ordering Information Here |
File details come from the government source that posted it. Updated .