This document contains a Request for Information (RFI) response regarding a federal construction project and the related Solicitation Notice. The RFI response provides clarification on specifications for an air shower, water lines, concrete pads, and overhead doors if certain bid options are accepted or declined. It also specifies fall arrest anchor details and additional anchors for a new roof. The Solicitation Notice is for the ADD/ALTER B403 CC project at Mansfield Air National Guard Base, involving renovation and construction of the B403 Corrosion Control facility. Services include demolition, site work, doors/windows, sprinklers, HVAC, electrical upgrades, and IT infrastructure. The project duration is estimated at 300 days with a Notice to Proceed. There are four additive bid items for additional work areas, an air shower, motorized door, and blast resistant windows. Bids will be evaluated without discussion and awarded in accordance with the FAR. The solicitation is set aside for small businesses with a NAICS code of 236220 and $1-5 million magnitude. The pre-bid conference is November 5 and bids are due December 7 through the SAM website.
View the file
Other files for this federal contract opportunity
Show all 50
ADD/ALTER B403 CC has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR INFORMATION
R E
Q U
E S
T O
R S
E C
T
IO
N
From: Date:
11/24/2020
To: Contracting Officer
1. Solicitation Number:
W50S8R-21-B-0001
2. Location of Project:
Building 403
3. Information Requested: (Include Specification Section and/or Drawing Number and Page if inquiring about a discrepancy)
Ref Drawing A101 keynote 13- Will specifications be provided for the Air Shower?
Ref Drawing CD101, keynote 6- If bid option 1 is not accepted can the 4” water line remain under the concrete pad? If bid option 1 is not accepted will a new concrete pad be required on exterior side of existing overhead doors? Will new overhead doors be required to replace existing overhead doors if bid option 1 is not accepted?
Ref Exhibit A Checklist Item 14- What information is to be included in the plant and equipment schedule if applicable?
Ref drawing A103 keynote 2- Will specifications and structural drawing details be provided for fall arrest anchor system on existing building roof? Will fall arrest anchors be required for new roof?
Attachments: Date Response Required:
By: Title:
Requestor's FAX Number: Requestor's Telephone Number:
C E
R E
S P
O N
S E
To: Date:
12/02/2020
Response:
• Specification for Air Shower to be stainless steel knock‐down 52”w x 72”d x 120”h 1 blower 3,600 RPM producing 1820 CFM @2”. The Government is not authorized to provide suggested sources or brand-name basis of design.
• If Additive Bid Item (ABI, not an "option") 1 is not accepted, o Install new waterline as shown on sheet CU101. Existing 4” water line can remain abandoned in place.
o No, a new concrete pad will not be required o No new OH doors will not be required. However Bid Option 3 is for new motorized OH doors.
• Disregard this information as a requirement for submission with bid; this is related to post-award
• See Detail 7/A503 for fall arrest anchors. Provide addition anchors as required near each of the roof drains on the new roof.
This information is a clarification of the solicitation/contract and does not change the contract terms or conditions.
This information is a proposed change to the solicitation/contract. An amendment will be issued.
Contracting Officer: