This document contains a solicitation notice and project description for federal contract opportunity number W50S8R-21-B-0001 issued by the 179th Airlift Wing, Mansfield Ohio ANG Contracting Office. The opportunity involves construction services for Project PBXP 169102 to add and alter Building 403 for corrosion control at Mansfield Air National Guard Base. Services include interior and exterior demolition, new sidewalks and drive access, security doors and windows, sprinkler and compressed air system installation, electrical upgrades, and wireless and intercom infrastructure. The pre-bid conference is scheduled for November 5th and bids are due December 7th. The project value is between $1-5 million and has an estimated 300-day performance period. The solicitation is set aside exclusively for small businesses in NAICS code 236220 with a size standard of $39.5 million average annual revenue.
View the file
Other files for this federal contract opportunity
Show all 50
ADD/ALTER B403 CC has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR INFORMATION
R E
Q U
E S
T O
R S
E C
T
IO
N
From:
Date:
11/16/2020
To: Contracting Officer
1. Solicitation Number:
W50S8R-21-B-0001
2. Location of Project:
Building 403
3. Information Requested: (Include Specification Section and/or Drawing Number and Page if inquiring about a discrepancy)
If the insulation value is to be a minimum R-40 with a fully-tapered insulation system (7” starting thickness), the overall thickness at the highest point of the roof system will be approximately 19” thick exceeding the perimeter wall height of 117’-4” indicated on a roof framing plan. There are two elevations listed for the top of the new CMU wall: 117'-4" on the structural framing plan and 118' on the architectural plan. Which new CMU wall height is correct?
Attachments:
Date Response Required:
By:
Title:
Requestor's FAX Number:
Requestor's Telephone Number:
C E
R E
S P
O N
S E
To:
Date:
Response:
118’-0” is correct and noted on C/S-301. The 117’-4” elevation noted on S-111 is incorrect.
This information is a clarification of the solicitation/contract and does not change the contract terms or conditions.
This information is a proposed change to the solicitation/contract. An amendment will be issued.