This document is a Questions and Answers (Q&A) file for Solicitation Number W50S7T-25-B-A005, a project for Repair Fire Hydrants. The solicitation involves replacing fire hydrants with specific technical requirements, including NST standard threading, left-opening direction, and a base white and top blue color scheme. The project covers 4-5 fire hydrants, with hydrant 6-12 being removed from the statement of work despite being shown on drawings. Key technical specifications include a 5" Storz pumper nozzle, two 2½" hose nozzles, and a presumed 5' bury depth based on existing infrastructure drawings. Potential bidders are directed to www.sam.gov for complete bid documentation, with questions being answered through August 14, 2025.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation Number: W50S7T-25-B-A005 Project Title: Repair Fire Hydrants Answers thru August 14, 2025
Questions and Answers
Number Bldg/Loc/
CLIN
Question Answer
1 Was reaching out to see if you could send me the bid plans and docs for your hydrant replacement job you have open for bid. Would also like to know when the due date is for them.
All of this information is already provided on www.sam.gov.
2 Threading: SOW specifies a 5″ Storz pumper nozzle and two 2½″ hose nozzles. Should nozzle threading match the local fire department standard (Peoria Fire/ILANG), or is a specific thread standard (e.g., NST/NH) required?
Nozzle threading needs to be NST standard.
3 Open Direction: Most ANG installations use open-left, but the SOW doesn’t specify. Please confirm the required direction.
Open direction is left opening.
4 Color: No hydrant color is listed. Is factory red acceptable, or does the base require a specific color standard (e.g., safety yellow or other coding)?
Hydrants need to be painted to match the base standard which is base white and top blue.
5 Bury Depth: We assume new hydrants match existing bury depths (likely 5′) at each location. Please confirm if all sites are standard 5′ or if any vary.
Bury depth is presumed 5' bury depth per existing infrastructure drawings.
6 CLINs 8-7, 7- 5, 6-6, 6-8
“While looking over this project I noticed that the solicitation calls out (5) fire hydrants and the drawing show the location for 5 hydrants, there are only 4 listed in the CLINs (8-7, 7-5,6-6, 6-8) the hydrant 6-12 is not listed.
Will this be given an updated CLIN, the drawing calls it CLIN 004 but the solicitation has 6-8 listed.”
No. Hydrant 6-12 was removed from the statement of work as it was found to be functional, however, was not removed from the drawing. Please disregard. We will attempt to delete the reference within the drawing and repost.