Attachment 3 - Bollards Detail.pdf

PDF 111 KB Posted

Attached to
Replace Fire Hydrants
Solicitation number
W50S7T25BA005
Issued by

About this file

The document is a technical drawing detailing the specifications for bollard (security post) installation for a fire hydrant placement project. The detailed cross-section diagram provides precise engineering specifications, including:

Bollard Construction Details:

  • 4' tall overall height
  • 6" standard galvanized steel pipe filled with concrete
  • Concrete footing with 1'6" diameter
  • Concrete cap under sleeve with heavy-duty bollard cover
  • Slope concrete base at exterior
  • A.C. paving or concrete per plan
  • Safety yellow sleeve with "Ideal Shield" or equivalent tape

Placement Diagram:

  • Two bollards positioned 36" apart
  • Bollards located adjacent to a hydrant
  • Typical interior/exterior installation detail
  • Scale of 1:10 with measurement guide provided
  • Dated April 5, 2023 at 7:30 AM

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bollard Post Placement

Wednesday, April 5, 2023 7:30 AM i-- 36" r· t-

36" -----i

Hydrant

BOLLARD/

GUARD

POST (TYP)

8. Attachment 4 Bollards Detail b4.pdf
0. bollard post placement_Redacted.pdf