CS451 CODE COMPLIANCE SITE PLAN (R1).pdf
PDF 521 KB Posted
- Attached to
- ADC HANGAR Federal contract opportunity
- Solicitation number
- W50S7020B0001
About this file
This document includes a code compliance site plan drawing and related federal contract opportunity notice for solicitation of bids. The site plan drawing depicts the layout of existing infrastructure and security features at the Georgia Army National Guard facility in Savannah, including fencing, gates, buildings, utilities, and fire safety equipment. The related contract opportunity is soliciting bids under solicitation number W50S7020B0001 for construction of a new ADC hangar at the facility. Interested bidders are encouraged to attend a pre-bid conference on July 7th at 10:00 AM EST to obtain additional details outlined in the solicitation section 00100. The Army is the contracting agency seeking proposals due by an unspecified deadline to construct the new hangar.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| ES102 - ELECTRICAL SITE PLAN - 2 (R1).pdf | ||
| W50S70-20-B-0001-0003.pdf | ||
| CD102 CIVIL UTILITY DEMOLITION PLAN (R1).pdf | ||
| B101 BORING LOGS (R1).pdf | ||
| GC004 ACCESS AND LAYDOWN PLAN (R1).pdf | ||
| W50S70-20-B-0001-0002.pdf | ||
| GC501 Access and Phasing Details-1 (R1).pdf | ||
| 01 45 35 Schedule of Special Inspections.pdf | ||
| GC005 Enlarged Access and Phasing Plan (R1).pdf | ||
| W50S70-20-B-0001-0001.pdf | ||
| Vendor Sign in Sheet Site Visit 7-7-20.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
I
D
E
W
A
L
K
C
H
A
I
N
L
I
N
K
F
E
N
C
E
C
H
A
I
N
L
I
N
C
E
METAL
SHED
METAL
SHED
A
S
P
H
A
V
E
M
E
N
T
C H
A I N
L I N
K
F
E N
C E
G
A
T
E
G
A
T
E
GUARD
SHACK
ASPH PAVEMENT
A
S
V
E
M
E
N
T
C
H
A
I
N
L
I
N
C
E
A
S
P
D
R
I
V
E
C
H
A
I
N
L
I
N
C
E
C H
A I N
L I N
K
F
E N
C E
CHAINLINK FENCE
C
H
A
I
N
L
I
N
C
E
METAL
SHED
GATE
CHAINLINK FENCE
CHAINLINK FENCE
BRUSHWOOD AVENUE
A
R
M
S
T
E
V
E
N
U
E
COMM.
BOX
AIR
VALVE
CLEANOUT
CLEANOUT
S T
O P
CLEANOUT
OVER
HANG
ELEC.
BOX
ELEC.
BOX
ELEC.
BOX
A/C
UNIT
CLEANOUT
A/C
UNIT
ELEC.
BOX
BOLLARDS
ANTENNA
BOLLARDS
BOLLARDS
A/C
UNIT
ELEC.
PANEL
ELEC.
BOX
A/C
UNIT
CONTROL
PANEL
ELEC.
BOX
ELEC.
BOX
S T
O P
ECP BLOCK
ECP
BLOCK
ELEC.
BOX
ELEC.
BOX
S
T
O
P
G7
G6G5 G4G3
G2G1
GZONE
FZONE
BOLLARDS
KEY
PAD
CLEANOUT
SPIGOT
CLEANOUT
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXXX
X
XXXXXX
X X
X X
X
X
X
X
X
XX
X
X X
X
X
LO
S
LO
S
LO
S
LO
S
LO
S
LO
S
LOS
LOS
LOS
LOS
LOS
LOS
LOS
LOS LOS
LOS LOS LOS LOS LOS LOS LOS LOS LOS LOS LOS
LOS
L O S
LO
S
LOS
LOS
L O S
L O S
L O S
LOS
LO
S
LOSLOSLOSLOSLOSLOSLOSLOSLOS
LOS
LOSLOS
LOS
L O S
L O S
L O S
LO
S
LO
S
LOS
LO
S
LO
S
LO
S
LO
S
LOS
LOS
LOS
LOS
CO
CO
CO
CO
CO
CO
CO
EXISTING FLIGHTLINE FENCE
VEHICLE ACCESS GATE
FIRE DEPARTMENT ENTRY
FIRE PUMP ROOM
6"
4"
JADC RAMP
METER
WATER
LO
S
LO
S
LO
S
LO
S
LO
S
LO
S
LOS
LOS
LOS
LOS
LOS
LOS
LOS
LOS LOS
LOS LOS LOS LOS LOS LOS LOS LOS LOS LOS LOS
LOS
L O S
LO
S
LOS
LOS
L O S
L O S
L O S
LOS
LO
S
LOSLOSLOSLOSLOSLOSLOSLOSLOS
LOS
LOSLOS
LOS
L O S
L O S
L O S
LO
S
LO
S
LOS
LO
S
LO
S
LO
S
LO
S
LOS
LOS
LOS
LOS
FIRE HYDRANT
FIRE HYDRANT
FIRE HYDRANT
SUMP TANK
BLDG 198
BLDG 195
60,000 GALLON WATER STORAGE TANK
R
R
R
103591CS451.DWG
5 6
D
C
A
B
1 2 3 4
E
D
C
A
B
E
5 61 2 3 4 ofsheet sheets date detailed checkeddesigned project contract rev.drawing file
C O
P Y
R I G
T
B
U R
S
M c D
O N
N E
L L
E
N G
I N
E E
R I N
G
C
O M
P A
N Y
I N
C
C
DATEREV.
REVISIONS
DESCRIPTION INIT
GEORGIA AIR NATIONAL GUARD
SAVANNAH/ HILTON HEAD IAP
SAVANNAH, GEORGIA
KANSAS CITY, MISSOURI
ENGINEERS ARCHITECTS & CONSULTANTS
103591
Project No. - XDQU109057
W9133L-15-D-0003-C004
165 AW, ADC
NEW CONSOLIDATED MX
HANGAR AND SHOPS
NOT FOR
CONSTRUCTION
CODE COMPLIANCE SITE PLAN
CS451 C
10/15/18
J. SHEPHERD L. MONZON
M. MILLER
A 10/15/18 B1 SUBMITTAL JTS
B 1/22/19 B2 SUBMITTAL JTS
C 5/1/19 B3 SUBMITTAL JTS
SCALE 1" = 40'
CODE COMPLIANCE SITE PLAN
A1
GENERAL NOTES:
1. SEE SHEET GC002 FOR LEGEND & ABBREVIATIONS.
2. SEE SHEET GC003 FOR GENERAL NOTES.
3. WHERE APPLICABLE, THE FOLLOWING MINIMUM FIRE PROTECTION
PROVISIONS MUST BE INCLUDED ON THE CODE COMPLIANCE SITE PLAN
IN ACCORDANCE WITH UFC 3-600-01 (CHANGE 2, 03-25-2018):
a. LINE OF ENCROACHMENT IDENTIFYING ASSUMED PROPERTY LINES
AND MINIMUM SEPARATION DISTANCES FROM ADJACENT
BUILDINGS.
b. BUILDING PERIMETER USED FOR FRONTAGE INCREASES.
c. FIRE DEPARTMENT ACCESS.
d. FIRE LANE WIDTH, MARKING AND LOCATIONS, APPROACH ROADS
AND TURN RADIUS AND LOCATION.
e. TYPE AND QUANTITY OF ANTITERRORISM SECURE ACCESS.
f. INTENDED FIRE DEPARTMENT MAIN ENTRANCE TO FACILITY.
g. LOCATION OF FIRE DEPARTMENT CONNECTIONS.
h. FIRE HYDRANTS, POST INDICATOR VALVE OR VALVES AND THEIR
CONNECTED WATER DISTRIBUTION MAINS SERVING FACILITY.
i. FIRE PUMP ROOM.
j. WATER STORAGE TANKS.
k. HAZARDOUS MATERIAL SPILL CONTAINMENT TANKS.
l. BACKFLOW PREVENTION ASSEMBLY OR ASSEMBLIES SERVING
WATER-BASED FIRE PROTECTION SYSTEMS (IF LOCATED OUTSIDE
OF BUILDING).
4-16.8.3 FIRE HYDRANTS MUST BE INSTALLED IN ACCORDANCE WITH NFPA
24, BUT SPACED NOT MORE THAN 300 FEET (91m) APART. PROVIDE A MINIMUM
OF TWO HYDRANTS LOCATED SO THAT PROTECTED EXPOSURES CAN BE
REACHED THROUGH HOSE RUNS NOT EXCEEDING 300 FEET (91m).
9-3.5.8.4 HYDRANTS MUST ALSO BE SPACED IN ACCORDANCE WITH THE
FOLLOWING REQUIREMENTS:
a. AT LEAST ONE HYDRANT MUST BE LOCATED WITHIN 150 FEET (45m)
OF THE FIRE DEPARTMENT CONNECTION.
9-3.5.9 PROTECTION
HYDRANTS LOCATED ADJACENT TO PARKING AREAS, VEHICLE TRAFFIC
AREAS, OR OTHER AREAS SUBJECT TO MECHANICAL DAMAGE, MUST BE
PROTECTED BY BOLLARDS. THE BOLLARDS MUST BE LOCATED SO THEY ARE
NOT DIRECTLY IN FRONT OF AN OUTLET. THE BOLLARDS MUST ALLOW
CLEARANCE TO ATTACH HOSES, ALLOW FOR THE REMOVAL OF THE HYDRANT
CAPS, AND FOR THE HYDRANT TO BE OPENED AND CLOSED WITHOUT
OBSTRUCTIONS, REFER TO UFC 3-260-01 WHERE BOLLARDS ARE REQUIRED
FOR HYDRANTS LOCATED ADJACENT TO AIRCRAFT PARKING AND SERVICING
APRONS.
R
| Sheets and Views |
| CS451 CODE COMPLIANCE SITE PLAN |
File details come from the government source that posted it. Updated .