CS451 CODE COMPLIANCE SITE PLAN (R1).pdf

PDF 521 KB Posted

Attached to
ADC HANGAR Federal contract opportunity
Solicitation number
W50S7020B0001
Issued by
Department of the Army Georgia Army National Guard

About this file

This document includes a code compliance site plan drawing and related federal contract opportunity notice for solicitation of bids. The site plan drawing depicts the layout of existing infrastructure and security features at the Georgia Army National Guard facility in Savannah, including fencing, gates, buildings, utilities, and fire safety equipment. The related contract opportunity is soliciting bids under solicitation number W50S7020B0001 for construction of a new ADC hangar at the facility. Interested bidders are encouraged to attend a pre-bid conference on July 7th at 10:00 AM EST to obtain additional details outlined in the solicitation section 00100. The Army is the contracting agency seeking proposals due by an unspecified deadline to construct the new hangar.

View the file

Other files for this federal contract opportunity

Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

I

D

E

W

A

L

K

C

H

A

I

N

L

I

N

K

F

E

N

C

E

C

H

A

I

N

L

I

N

C

E

METAL

SHED

METAL

SHED

A

S

P

H

A

V

E

M

E

N

T

C H

A I N

L I N

K

F

E N

C E

G

A

T

E

G

A

T

E

GUARD

SHACK

ASPH PAVEMENT

A

S

V

E

M

E

N

T

C

H

A

I

N

L

I

N

C

E

A

S

P

D

R

I

V

E

C

H

A

I

N

L

I

N

C

E

C H

A I N

L I N

K

F

E N

C E

CHAINLINK FENCE

C

H

A

I

N

L

I

N

C

E

METAL

SHED

GATE

CHAINLINK FENCE

CHAINLINK FENCE

BRUSHWOOD AVENUE

A

R

M

S

T

E

V

E

N

U

E

COMM.

BOX

AIR

VALVE

CLEANOUT

CLEANOUT

S T

O P

CLEANOUT

OVER

HANG

ELEC.

BOX

ELEC.

BOX

ELEC.

BOX

A/C

UNIT

CLEANOUT

A/C

UNIT

ELEC.

BOX

BOLLARDS

ANTENNA

BOLLARDS

BOLLARDS

A/C

UNIT

ELEC.

PANEL

ELEC.

BOX

A/C

UNIT

CONTROL

PANEL

ELEC.

BOX

ELEC.

BOX

S T

O P

ECP BLOCK

ECP

BLOCK

ELEC.

BOX

ELEC.

BOX

S

T

O

P

G7

G6G5 G4G3

G2G1

GZONE

FZONE

BOLLARDS

KEY

PAD

CLEANOUT

SPIGOT

CLEANOUT

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XXXXXXXXX

X

XXXXXX

X X

X X

X

X

X

X

X

XX

X

X X

X

X

LO

S

LO

S

LO

S

LO

S

LO

S

LO

S

LOS

LOS

LOS

LOS

LOS

LOS

LOS

LOS LOS

LOS LOS LOS LOS LOS LOS LOS LOS LOS LOS LOS

LOS

L O S

LO

S

LOS

LOS

L O S

L O S

L O S

LOS

LO

S

LOSLOSLOSLOSLOSLOSLOSLOSLOS

LOS

LOSLOS

LOS

L O S

L O S

L O S

LO

S

LO

S

LOS

LO

S

LO

S

LO

S

LO

S

LOS

LOS

LOS

LOS

CO

CO

CO

CO

CO

CO

CO

EXISTING FLIGHTLINE FENCE

VEHICLE ACCESS GATE

FIRE DEPARTMENT ENTRY

FIRE PUMP ROOM

6"

4"

JADC RAMP

METER

WATER

LO

S

LO

S

LO

S

LO

S

LO

S

LO

S

LOS

LOS

LOS

LOS

LOS

LOS

LOS

LOS LOS

LOS LOS LOS LOS LOS LOS LOS LOS LOS LOS LOS

LOS

L O S

LO

S

LOS

LOS

L O S

L O S

L O S

LOS

LO

S

LOSLOSLOSLOSLOSLOSLOSLOSLOS

LOS

LOSLOS

LOS

L O S

L O S

L O S

LO

S

LO

S

LOS

LO

S

LO

S

LO

S

LO

S

LOS

LOS

LOS

LOS

FIRE HYDRANT

FIRE HYDRANT

FIRE HYDRANT

SUMP TANK

BLDG 198

BLDG 195

60,000 GALLON WATER STORAGE TANK

R

R

R

103591CS451.DWG

5 6

D

C

A

B

1 2 3 4

E

D

C

A

B

E

5 61 2 3 4 ofsheet sheets date detailed checkeddesigned project contract rev.drawing file

C O

P Y

R I G

T

B

U R

S

M c D

O N

N E

L L

E

N G

I N

E E

R I N

G

C

O M

P A

N Y

I N

C

C

DATEREV.

REVISIONS

DESCRIPTION INIT

GEORGIA AIR NATIONAL GUARD

SAVANNAH/ HILTON HEAD IAP

SAVANNAH, GEORGIA

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

103591

Project No. - XDQU109057

W9133L-15-D-0003-C004

165 AW, ADC

NEW CONSOLIDATED MX

HANGAR AND SHOPS

NOT FOR

CONSTRUCTION

CODE COMPLIANCE SITE PLAN

CS451 C

10/15/18

J. SHEPHERD L. MONZON

M. MILLER

A 10/15/18 B1 SUBMITTAL JTS

B 1/22/19 B2 SUBMITTAL JTS

C 5/1/19 B3 SUBMITTAL JTS

SCALE 1" = 40'

CODE COMPLIANCE SITE PLAN

A1

GENERAL NOTES:

1. SEE SHEET GC002 FOR LEGEND & ABBREVIATIONS.

2. SEE SHEET GC003 FOR GENERAL NOTES.

3. WHERE APPLICABLE, THE FOLLOWING MINIMUM FIRE PROTECTION

PROVISIONS MUST BE INCLUDED ON THE CODE COMPLIANCE SITE PLAN

IN ACCORDANCE WITH UFC 3-600-01 (CHANGE 2, 03-25-2018):

a. LINE OF ENCROACHMENT IDENTIFYING ASSUMED PROPERTY LINES

AND MINIMUM SEPARATION DISTANCES FROM ADJACENT

BUILDINGS.

b. BUILDING PERIMETER USED FOR FRONTAGE INCREASES.

c. FIRE DEPARTMENT ACCESS.

d. FIRE LANE WIDTH, MARKING AND LOCATIONS, APPROACH ROADS

AND TURN RADIUS AND LOCATION.

e. TYPE AND QUANTITY OF ANTITERRORISM SECURE ACCESS.

f. INTENDED FIRE DEPARTMENT MAIN ENTRANCE TO FACILITY.

g. LOCATION OF FIRE DEPARTMENT CONNECTIONS.

h. FIRE HYDRANTS, POST INDICATOR VALVE OR VALVES AND THEIR

CONNECTED WATER DISTRIBUTION MAINS SERVING FACILITY.

i. FIRE PUMP ROOM.

j. WATER STORAGE TANKS.

k. HAZARDOUS MATERIAL SPILL CONTAINMENT TANKS.

l. BACKFLOW PREVENTION ASSEMBLY OR ASSEMBLIES SERVING

WATER-BASED FIRE PROTECTION SYSTEMS (IF LOCATED OUTSIDE

OF BUILDING).

4-16.8.3 FIRE HYDRANTS MUST BE INSTALLED IN ACCORDANCE WITH NFPA

24, BUT SPACED NOT MORE THAN 300 FEET (91m) APART. PROVIDE A MINIMUM

OF TWO HYDRANTS LOCATED SO THAT PROTECTED EXPOSURES CAN BE

REACHED THROUGH HOSE RUNS NOT EXCEEDING 300 FEET (91m).

9-3.5.8.4 HYDRANTS MUST ALSO BE SPACED IN ACCORDANCE WITH THE

FOLLOWING REQUIREMENTS:

a. AT LEAST ONE HYDRANT MUST BE LOCATED WITHIN 150 FEET (45m)

OF THE FIRE DEPARTMENT CONNECTION.

9-3.5.9 PROTECTION

HYDRANTS LOCATED ADJACENT TO PARKING AREAS, VEHICLE TRAFFIC

AREAS, OR OTHER AREAS SUBJECT TO MECHANICAL DAMAGE, MUST BE

PROTECTED BY BOLLARDS. THE BOLLARDS MUST BE LOCATED SO THEY ARE

NOT DIRECTLY IN FRONT OF AN OUTLET. THE BOLLARDS MUST ALLOW

CLEARANCE TO ATTACH HOSES, ALLOW FOR THE REMOVAL OF THE HYDRANT

CAPS, AND FOR THE HYDRANT TO BE OPENED AND CLOSED WITHOUT

OBSTRUCTIONS, REFER TO UFC 3-260-01 WHERE BOLLARDS ARE REQUIRED

FOR HYDRANTS LOCATED ADJACENT TO AIRCRAFT PARKING AND SERVICING

APRONS.

R

Sheets and Views
CS451 CODE COMPLIANCE SITE PLAN

File details come from the government source that posted it. Updated .