The document addresses nine contractor inquiries clarifying scope, responsibilities, and project requirements. Key clarifications include: the Government will remove and reinstall BAK-12 energy absorber units, with the contractor responsible for ensuring correct anchor bolt placement; the contractor must provide the testing laboratory and obtain cylinder break reports for the concrete pour; the work area is not a permit-required confined space despite being approximately 8 feet below grade; and no liquidated damages clause is associated with the contract. Regarding concrete specifications, the requirement is 24 inches of concrete with 6 inches of crushed aggregate subbase (30 inches total material depth), with the SOW Step 6.1 updated accordingly. Government personnel will perform BAK-12 reinstallation, tensioning, alignment, and system certification testing, excluding these tasks from contractor scope. Technical drawings and Air Force sources referenced in the SOW are attached as PDFs to the solicitation. Government review turnaround for pre-construction submittals will be completed within 5 working days to accommodate the 60-day performance period. The contractor is recommended to have a representative present during BAK-12 installation to ensure proper fit.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFI responses for Project: Window Awnings with Installation
W50S6T26QA035
Current as of: 3 Sep 2026
QUESTION ANSWER
1. Please confirm whether the Contractor is responsible for reinstallation of the BAK-12 energy absorber units onto the new anchor bolts in accordance with TO 35E8-2-5-1, as stated in the specification, OR whether the
Government intends to remove and/or reinstall the existing units, as discussed at the job walk.
The government will remove and reinstall the BAK-12. The contractor is responsible to assure the anchor bolts are in the correct location for installation. It is recommended the contractor (or a representative) be present during installation to assure you are fit. The SOW step 7 section has been updated.
2. Request provide all Air Force "Sources and
References" for this system. Some of the links do not work in the attachments to the solicitation.
Technical descriptions are attached as PDF’s to the solicitation.
3. USAF Standard Drawing 67F2013A – The
SOW references this drawing for the anchor bolt pattern and dimensions, rebar spacing/grid pattern, and energy absorber baseplate dimensions needed for the alignment template. We were unable to locate the drawing in the solicitation package. Please provide the referenced drawing.
Technical descriptions are attached as PDF’s to the solicitation.
4. Step 7 – BAK-12 Reinstallation and Testing –
Please confirm that the BAK-12 reinstallation, tensioning, alignment, and system certification testing will be performed by base personnel and are excluded from the contractor’s scope.
Yes. Removal, reinstallation, tensioning, alignment, and system certification testing will be performed by Government personnel.
5. Testing Laboratory – SUB-09 requires cylinder break reports for the new concrete pour. Please confirm whether the testing laboratory is to be provided by the
Government or by the contractor.
Contractor
6. Pour Depth – During the site visit, we discussed 24 inches of concrete over 6 inches of crushed aggregate subbase, for a total depth of 30 inches. However, Step 6.1
24 inches of concrete. 6 inches of aggregate. 30 inches in total material. Section Step 6.1 updated.
RFI responses for Project: Window Awnings with Installation
W50S6T26QA035
Current as of: 3 Sep 2026 specifies 6 inches of crushed aggregate subbase with 18 inches of concrete, for a total of 24 inches. Please confirm which requirement governs, as this affects concrete quantities, cage height, and anchor bolt embedment.
7. Confined Space – The work is inside a reinforced concrete housing approximately 8 feet below grade. Please confirm whether this area is considered a permit-required confined space and clarify the requirements for entry permits, atmospheric monitoring, attendant, and rescue provisions.
The pit will be fully open. Not considered a permit-required confined space. No entry permits required nor atmospheric monitoring attendant.
8. Submittal Review – Please confirm the anticipated Government review turnaround time for pre-construction submittals, as this review is within the 60-day performance period.
The governments review turnaround will be within 5 working days.
9. Liquidated Damages – Please confirm whether liquidated damages apply to the 60-day performance period and, if so, the applicable rate.
A liquidated damage clause is not associated with the contract solicitation.