Performance Work Statement (PWS)

Mechanical Repair, Finishing and RF Pattern Testing of Lewis Scanner Antennas for

S-Band Lewis Scanner Azimuth Antenna PN: 583Z5001MC-1 and

S-Band Lewis Scanner Elevation Antenna PN: 583Z5001MC-3

1.0 PURPOSE AND APPLICATION

1.1 The purpose of this PWS is to define the mechanical and electrical acceptance standards for overhaul of the S-Band Lewis Scanner Azimuth Antenna PN:

583Z5001MC-1 and S-Band Lewis Scanner Elevation Antenna PN:

583Z5001MC-3 antenna assemblies that are part of the AN/MPS-T1(V) Threat Simulator radar system. Requirements include hardware and electrical functionality as well as mechanical repair, finishing and RF pattern testing.

2.0 BACKGROUND

2.1 This PWS describes the work and services that are required for the inspection, overhaul, testing and repair of the S-Band Lewis Scanner Azimuth (AZ) and Elevation (EL) antennas. Both antennas are identical despite the different part numbers, the only difference being the waveguide mounting hardware. Each antenna assembly is comprised of five sections:

A. Scanner (PN: 583Z5024MC-1): Contains a rotary joint, P/N 2176, that connects to WR284 waveguide.

B. Scanner Cone (PN 583Z5014-1): Comprised of an input parallel plate waveguide section containing an input for the scanner and RF mirror located in the middle of section that directs RF energy as the scanner rotates.

C. Geodesic Lens (PN 583Z5010-1): This is a parallel plate waveguide section containing a sunken curved waveguide path to enhance RF energy direction for beamforming.

D. Asymmetrical Horn (PN 583Z5021-1): This is the output parallel plate waveguide section for directing RF energy onto a reflector.

E. Reflector (PN 583Z5011-1): This is the final output of antenna system. The reflector is approximately 2 FT x 16 FT.

The antennas operate in the 2.9 GHz to 3.1 GHz frequency range and the RF beam is electro-mechanically scanned from (-) 10 degrees to (+) 10 degrees without moving the radar system platform.

3.0 APPLICABLE DOCUMENTS

The following documents specified form a part of this PWS to the extent specified herein. The most recent revision of the referenced document at the time this PWS shall be used unless otherwise specified. In the event of conflict between the applicable documents and this PWS, the PWS takes precedence. All second tier and below references cited in mandatory compliance documents shall be considered as guidance only. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.

3.1 Military Standards and Specifications

W25G1V-18-R-0008 Attachment I

MIL-STD-2073-1E, DoD Standard Practice for Military Packaging (w/CHANGE 1), DATED: 23 MAY 2008.

MIL-STD-129, Military Marking for Shipment and Storage (Latest Version), DATED:

15 DEC 202002.

MIL-PRF-85285E, Performance Specification, Coating: Polyurethane, Aircraft and Support Equipment, DATED: 12 JAN 2012.

TO 43D7-11-21-2-1, Technical Manual, Maintenance Instructions, Radar Training Set, AN/MPS-T1 (V), Part No. 583Z1000MG, 10 SEP 2005, Change 3 -20 NOV 2012.

TO 43D7-11-21-4, Technical Manual, Illustrated Parts Breakdown, Radar Training Set, AN/MPS-T1 (V), Part Nos. 583Z1000M1 and 583Z1000ME, This Publication Supersedes TO 43D7-11-21-4, 26 July 2011.

3.2 Handbooks

None.

3.3 Other Government Documents

J/F-12/04460, APPLICATION TITLE: AN/MPS-T1(V) RADAR SET, TRANING SET

(OT-85/M), DATED: 24 MAR 1976.

Qualified Products List, QPL-81706.

Army Regulation 530-1, TITLE: Operations Security (OPSEC), DATED: 26 SEPT 2014.

3.4 Non-Government Documents

Contract End Item Subsystem Design Analysis Report on Pattern Analysis AN/MPS-T1 (U), General Dynamics, Convair Aerospace Division, Fort Worth Operation, Fort Worth, TX 76101, DATED: 15 May 1972. NOTE: Document (FZE- 1811) Declassified IAW Electronic Warfare Threat Emitters, Classification Guide, SM-ALC/MMC, DATED: 15 April 1983 by Carl W. Chapman/MMCE DATED: 20

OCT 1983.

ASTM D3951, Standard Practice for Commercial Packaging (ASTM D3951-15).

ANSI/AWS D1.2/D1.2M:2008.

ANSI/AWS D1.1/D1.1M:2010.

AWS D17.2/17.2M-2007.

AWS D1.2/D1.2M:2008, CLASS B.

3.5 Drawings

583Z4012_81755 Series; 583Z4278_81755 Series; 583Z4287_81755 Series;

583Z4301_81755 Series; 583Z4306_81755 Series; 583Z4310_81755 Series;

583Z4323_81755 Series; 583Z4378_81755 Series; 583Z5001_81755 Series;

583Z5003_81755 Series; 583Z5005_81755 Series; 583Z5009_81755 Series;

583Z5010_81755 Series; 583Z5011_81755 Series; 583Z5012_81755 Series;

583Z5013_81755 Series; 583Z5014_81755 Series; 583Z5017_81755 Series;

583Z5019_81755 Series; 583Z5021_81755 Series; 583Z5023_81755 Series;

583Z5024_81755 Series; 583Z5030_81755 Series; 583Z5032_81755;

583Z5033_81755 Series; 583Z5036_81755 Series; 583Z5038_81755 Series;

583Z5039_81755 Series; 583Z5042_81755 Series; 583Z5045_81755 Series;

583Z5048_81755 Series; 583Z5049_81755 Series; 583Z5050_81755 Series;

583Z5051_81755 Series; 583Z5053_81755 Series; 583Z5058_81755 Series;

583Z5059_81755 Series; 583Z5060_81755 Series; 583Z5063_81755 Series; and 583Z5087_81755 Series.

3.6 Forms

ELTY Form 583, TITLE: Tobyhanna Army Depot On-Post Training Record. List the title

ELTY Form 648-C, TITLE: Request for Access to Tobyhanna Army Depot. List the title

Forms are available from Management Assistant, Melanie A. Janosky, Installation Services, Customer Service Branch, and MailTo: Melanie.a.janosky.civ@mail.mil.

Drawings and specifications will be furnished upon request. The drawings and specifications are for PWS requirements and are International Traffic Arms Regulations (ITAR) restricted and will only be released to interested Vendors who have a current and valid registration on the Joint Certification Program (JCP) site. The JCP site is https://public.logisticsinformationservice.dla.mil/Public Home/jcp/default.aspx.

Contact the contract Specialist Maureen.Myrthel.civ@mail.mil with Joint Certification Program (JCP) certification information to obtain a copy of the drawings and specification.

Due to the number of drawings and file sizes all drawings will be transmitted to interested vendors through ARMDEC’s Safe Access File Exchange (SAFE) website:

https://safe.amrdec.army.mil/safe/Welcome.aspx

4.0 SCOPE OF WORK

4.1 The Vendor shall perform mechanical repair and finishing of the antennas to include iridite coating and epoxy primer. When mechanical repairs and primer coatings are completed the sections shall be assembled as an antenna assembly and electrical performance verified by measuring antenna patterns.

If the antenna assemblies do not initially pass electrical performance the vendor shall make any alignments necessary for them to pass specification. In no case shall tools or equipment; e.g., chisels, paint scrapers, screw drivers, pry bars, electric or pneumatic sanders, impact wrenches, staplers, drills, ratchets, be used to accomplish mechanical work such that the inappropriate use of results in damage to the antenna assembly, hardware, electrical cable and motors, waveguide, any other piece parts, or GFE.

4.2 One (1) scanner (PN: 583Z5024MC-1) is being provided by the Government for the Vendor’s use in satisfying the requirements of this PWS. The scanner section will not require any mechanical repair work or finishing. The scanner section will be shipped to the Vendor fully painted and shall be used for buildup of the antenna assembly before RF pattern testing is conducted. The scanner is necessary to introduce RF energy into the scanner cone.

4.3 Two (2) scanner cones (PN: 583Z5001MC-1 & PN: 583Z5001MC-3) are being provided by the Government for the Vendor’s use in satisfying the requirement of this PWS. One scanner cone will be shipped disassembled. The other scanner cone shall be dissembled at the Vendor’s facility. These scanner cones have numerous scratches as a result of TYAD personnel attempting to reassemble out of shape halves. The two scanner cones shall be repaired starting from a disassembled condition in order to replace the reflective metal tape and RF absorber attached to the supporting sidewalls. The interior metal skins shall be cleaned (not sanded) and have an iridite coat applied as needed.

All surfaces are to be examined for mechanical damage, corrosion, uniform

W25G1V-18-R-0008 Attachment I https://public.logisticsinformationservice.dla.mil/Public%20Home/jcp/default.aspx mailto:Maureen.Myrthel.civ@mail.mil https://safe.amrdec.army.mil/safe/Welcome.aspx thickness, metal fatigue, cracks, metal surface bulges, weld separations, metal and rivet burs and RF burns and/or arcing.

Once reassembled the scanner cones shall have the outer skin paint coating lightly sanded (not removed) and then an epoxy based primer coat shall be applied.

Any area of the scanner cone surface that has been media blasted down to the bare metal shall have an epoxy based primer applied. The scanner cone shall be examined for warpage incurred from prior media blasting. The gap between top and bottom metal sheets shall be between 0.60” +/-0.05”. The Vendor shall provide for the verification of uniform spacing of parallel plates. The verification of the gap spacing shall be demonstrated to the Government by the Vendor at time of inspection (See Paragraph 7.0). Extensive metal shaping shall be used to obtain and maintain the gap between the top and bottom metal sheets.

The scanner cones shall be Voltage Standing Wave Ratio (VSWR) tested after repair. The VSWR is to be 1.9 to 1.0 or better. The Vendor shall provide the Government with an approach for measuring the VSWR in the response to testing in Paragraph 7.0.

These scanner cones will be the first items to be shipped to the Vendor for testing and evaluation (See Paragraph 7.3).

4.4 Two (2) geodesic lenses (PN 583Z5010-1) are being provided by the Government for the Vendor’s use in satisfying the requirement of this PWS.

The two geodesic lenses shall be inspected and evaluated to determine the need for required mechanical repair work. These geodesic lenses shall be overhauled. They will be shipped to the vendor with a primer finish and used for buildup of the antenna assembly before RF pattern testing.

4.5 Two (2) asymmetrical horns (PN 583Z5021-1) are being provided by the Government for the Vendor’s use in satisfying the requirement of this PWS.

The two asymmetrical horns shall be inspected and evaluated to determine the need for required mechanical repair work. These asymmetrical horns shall be overhauled. Radome material shall be replaced. They will be shipped to the vendor with a primer finish and used for buildup of the antenna assembly before RF pattern testing.

4.6 Two (2) reflectors (PN 583Z5011-1) are being provided by the Government for the Vendor’s use in satisfying the requirement of this PWS. One of the two reflectors will not require any mechanical repair work. It will be shipped to the vendor with a primer finish and used for buildup of the antenna assembly before RF pattern testing.

The other reflector requires re-construction and replacement of the reflective material and shall be coated with an epoxy based primer before installing onto the antenna assembly for RF pattern testing. The re-construction of this damaged reflector shall be completely addressed in the test and evaluation report delivered to the Government identifying all replacement parts and materials. This damaged reflector shall be re-constructed by the Vendor.

Both reflectors shall be inspected and evaluated to determine the need for required mechanical repair work. The reflectors shall be overhauled.

4.7 The scanner, scanner cones, geodesic lenses, asymmetrical horns and reflectors shall be assembled such that two (2) complete S-Band Lewis Scanner antennas are completely assembled and ready for RF antenna pattern testing. RF pattern testing shall be conducted and pattern measurements taken at five (5) frequencies and eleven (11) separate scanning angles.

4.8 The Government’s rights to all designs, drawings, specifications, engineering notes and other works developed in the performance of this contract shall be In Accordance With (IAW) DFARS clause 252.227-7013, Rights In Technical Date – Noncommercial Items. Any asserted use or release restrictions shall be provided by the Contractor IAW DFARS clause 252.227-7037 – Validation of Restrictive Markings on Technical Data. All work shall be documented using Vendor format and provided to the Government IAW DFARS clause 252.277- 7026 – Deferred Delivery of Technical data or Computer Software. See PWS Paragraph 12.0 for documentation that shall be furnished to the Government as a deliverable.

4.9 The Vendor shall replace reflective metal tape and RF absorber attached to the supporting sidewalls of the scanner cones, replace radome material on the horn assembly, RF absorber material shall be attached to the phenolic spacers by the appropriate adhesives, all hardware including bolts, nuts, washers, screws removed from any assembly during refurbishment and repair shall be replaced by new and of equal grade standard and quality hardware and installed with the correct torque and tension. All materials, parts, composite surface applicants, conductive coatings, restorative materials, paints (color and type), metal fillers, caulking, iridite and adhesives shall be approved by the Government prior to work being performed.

5.0 TECHNICAL INTERCHANGE MEETINGS (TIMs)

5.1 The Vendor shall plan for three (3) TIMs to be held at the Vendor’s facility.

5.2 The Vendor shall plan, host, attend, coordinate, support and conduct the TIMs. The TIMs shall be conducted at the Vendor’s facility, agreed upon location, or via teleconference/video teleconference (VTC). All such TIMs shall be included in the overhaul schedule and may be held concurrently with the Government’s approval. The Government reserves the right to cancel any TIM or to require any TIM to be scheduled at critical points during the period of performance. The Vendor shall prepare and deliver agendas, presentation materials, and minutes for each TIM. Action item documentation, assignment of responsibility for completion and due dates shall be determined prior to adjournment of all TIMs. The Vendor shall identify, present and make available to the Government a Project Manager and an alternate, who shall serve as the focal points and coordinators for all requirements. Both the Program Manager and alternate shall attend the TIMS when conducted.

Project management is responsible for the antenna system overhaul and allowing Government access to the Vendor’s facility in areas that are necessary for completing the overhaul. The Project Manager and alternate shall possess technical, interpersonal, conceptual, communication, and management skills necessary for successfully completing the requirements of this PWS.

A. First TIM (Prior to Start of Scanner Cone Overhaul and after issuance of the First “Notice to Procced (NTP)”: The Vendor shall work closely with the Contracting Officers Representative (COR). The COR will meet with the Vendor at the Vendor’s facility before work is started. The processes and methods; e.g., mechanical, chemical, electrical, etc. that the Vendor intends to employ during the antenna overhaul shall be presented and reviewed by the TYAD COR. The Vendor shall provide to the Government for review collected data, inspection reports, analysis and recommendations that Vendor is required by this PWS in Vendor format.

The S-Band Lewis Scanner antenna evaluation report shall have been completed by the Vendor as required in Paragraph 7.0 and delivered to the Government prior to the scheduling of the first TIM.

TIM 1 shall be held five (5) days after Government’s issuance of the first “NTP” as found in Paragraph 7.0 for scanner cone repair.

B. Second TIM (During Mechanical Repair and after issuance of the Second “NTP”): The Vendor shall provide the Government with all test reports and documentation that result from the mechanical antenna assembly overhaul.

The overhaul process shall be discussed and an inspection of the current condition of the antenna assembly at time of the TIM by the Government.

The inspection shall include, but not limited to, the following: sheet metal work, fabrication of parts, plating, abrasive blasting, welding, painting and replacement of materials in the waveguide. Vendor scheduling and developed drawings shall be presented at time of the TIM.

TIM 2 shall be held ten (10) days after Government’s issuance of the second “NTP” as found in Paragraph 7.0 for geodesic lenses, asymmetrical horn and reflector repair.

C. Third TIM (At Time of Antenna Testing): The Government shall witness the RF pattern testing for the S-Band Lewis Scanner Azimuth and Elevation antennas. RF pattern testing shall be conducted and pattern measurements taken at five (5) discrete frequencies and eleven (11) separate scanning angles. The RF performance test plan shall be made available prior to the third TIM (See Paragraph 7.2).

The Vendor shall notify the Government that the Vendor has scheduled pattern testing ten (10) days prior to the start of testing.

TIM 3 Shall be held twenty-five (25) days after 3rd NTP.

5.3 All TIMs shall be at a time, date and location mutually agreed upon by the Vendor and Government. The Government reserves the right to conduct the TIM via teleconference when circumstances warrant. TIMs conducted via teleconference must be provided by and hosted by the Vendor unless otherwise directed by the Government. When the Vendor provides the TIM via teleconference, sufficient communication lines must be made available as to allow all appropriate principals of the teleconference to dial in and attend for the duration of the teleconference.

6.0 S-BAND LEWIS SCANNER ANTENNA GENERAL CHARACTERISTICS

6.1 The following characteristics represent those derived from historical technical documentation that were developed under a Contract End Item Subsystem Design Analysis Repot on Pattern Analysis AN/MPS-T1 (U), DATED: 15 May 1972. This data is provided for guidance purposes only and does not represent measured data resulting from testing conducted at the Tobyhanna Army Depot on S-Band Lewis Scanner antennas. TO 43D7-11-21-1 data is also provided. The following are presented here:

A. Frequency range: 2,900 MHz to 3,100 MHz.

B. Polarization:

6.1.b.1 Azimuth Trough – Vertical.

6.1.b.2 Elevation Trough - Horizontal.

C. VSWR: 1.5 (Maximum).

D. Gain: 32.0 ± 2.0 dBi.

E. Beamwidth (3 dB):

6.1.e.1 1.9 DEG to 2.1 DEG (Horizontal).

6.1.e.2 9 DEG to 11 DEG (Vertical).

F. Sidelobes:

6.1.f.1 Scan Plane: (-) 20 dB for 90 % of all beam positions. (-) 18 dB for all scan angles outside the central ± 4 degree scan angle.

6.1.f.2 Non-scan Plane: (-) 15 dB.

G. Scan Rate: 15/16 Hz.

H. Scan Sector: 20 ± 2 DEGs.

I. PEP RF: 1.0 MW (REF: TO 43D7-11-21-1).

J. AVG RF Power: 2.0 KW (REF: TO 43D7-11-21-1).

7.0 S-BAND LEWIS SCANNER ANTENNA EVALUATION AND REPAIR ACTIVITIES

7.1 The Vendor shall perform a visual and mechanical inspection to determine the reparability of the antennas. Inspections shall include; but, are not limited to the following:

A. Loose, damaged or missing hardware.

B. Damaged mounting holes and threads.

C. Damaged rivets and unacceptable surface heights, raised, popped, or missing rivets.

D. Water damage; i. e., cracked, bent, otherwise distorted metal areas resulting from the freezing of liquid.

E. Damaged waveguide bottom and upper plates and interface between (joins) sections and bulges.

F. Geodesic lens damage.

G. Dimensioning of the waveguide to include separation distance between the upper and lower parallel plates.

H. Parallel plate metal thickness over the entire surface of the waveguide, both upper and lower plates.

I. Broken or cracked welds.

J. All surfaces are to be examined for mechanical damage, corrosion, uniform thickness, metal fatigue, cracks, metal surface bulges, weld separations, metal and rivet burs and RF burns and/or arcing.

7.2 All mechanical, electrical, radio frequency, laser and optical measurement instrumentation shall have current calibration. The Vendor shall ensure that all inspection, measuring, and test equipment, including mechanical, automated, or electronic inspection and test equipment, is suitable for its intended purposes and is capable of producing results that can be verified and validated by the Government. The Vendor shall establish and maintain procedures to ensure that equipment is routinely calibrated, inspected, checked, and maintained. The procedures shall include provisions for handling, preservation, and storage of equipment, so that its accuracy and fitness for use are maintained.

Calibration procedures shall include specific directions for calibration and limits for accuracy and precision. When accuracy and precision limits are not met, there shall be provisions for remedial action to reestablish the limits and to evaluate whether there was any adverse effect on the equipment or device's performance.

Calibration standards used for inspection, measuring, and test equipment shall be traceable to U.S. Government, Department of Defense (DoD), U.S military, national or international standards. If national or international standards are not practical or available, the manufacturer shall use an independent reproducible standard. If no applicable standard exists, the manufacturer shall establish and maintain an in-house standard.

The equipment identification, calibration dates, the individual performing each calibration, and the next calibration date shall be documented. These records shall be displayed on or near each piece of equipment or shall be readily available to the personnel using such equipment and to the individuals responsible for calibrating the equipment. The Government reserves the right to inspect and review all equipment calibration documentation and observe all equipment usage in satisfying the requirements of this PWS.

All calibration requirements shall be documented and provided to the Government for review. U.S. Government, Department of Defense (DoD), U.S.

military, in-house standard, national and international standards shall be identified and referenced in the documentation that shall be provided to the Government

7.3 The Vendor shall provide to the Government two (2) Test and Evaluation (T&E) reports. The first T&E report is for the two (2) scanner cones (PN:

583Z5001MC-1 & PN: 583Z5001MC-3). The second T&E report is for the two

(2) geodesic lenses (PN 583Z5010-1), two (2) asymmetrical horns (PN 583Z5021-1) and two (2) reflectors (PN 583Z5011-1).

A. The Vendor shall prepare a T&E report after the visual, measurement and mechanical inspection is completed and notify in writing by providing the evaluation reports to the Tobyhanna Army Depot with repair methods that will restore the antenna assemblies to a like new condition. The Vendor shall provide to the COR and the Contracting Officer concurrently, the first repair T&E report fifteen (15) days after receiving the two (2) S-Band Lewis Scanner cones (PN: 583Z5001MC-1 & PN: 583Z5001MC-3 at the Vendor’s repair facility. The Vendor shall provide to the COR and the Contracting Officer concurrently, the second repair T&E report fifteen (15) days after receiving the two (2) geodesic lenses (PN 583Z5010-1), two (2) asymmetrical horns (PN 583Z5021-1) and two (2) reflectors (PN 583Z5011-1) at the Vendor’s repair facility. The T&E reports shall contain an explanation of how the evaluations were developed and conducted, specialized labor and materials needed to complete the overhaul, cost and scheduling for the completion of repair, test and alignment procedures to be conducted and method of mechanical and finishing overhaul. The T&E report for the scanner cones shall contain a method for the VSWR testing. Each T&E shall include, but not limited to, the following: Location where work shall be performed; total dollar amount of the proposal; direct labor (types of labor, hours, total estimated labor cost, overhead rate, total estimated overhead cost; subcontractor cost; parts and materials cost; special equipment costs (rented or purchased); and travel costs. The cost breakdown shall be signed and dated by a responsible authorized corporate approving or certifying official. The evaluation report shall identify any potential risk factors that can result in a processing occurrence or in a processing impact that is uncertain and would diminish the RF performance of the S-Band Lewis Scanner Antenna and would likely result in work delay shall all be identified and listed in the evaluation report. The Tobyhanna Army Depot, COR will review the inspection and evaluation report and determine if it is the Government’s best interest to issue a Notice to Proceed (NTP). The Vendor shall take no further action until the T&E has been evaluated by the Government and the written instruction is provided by the TYAD Contracting Officer (CO) as to whether the Government’s intention is to proceed. The Government’s review of the Vendor’s T&E report shall not obligate the Government to proceed with the antenna overhaul as specified in that report.

7.3.a.1 The Government will review the first T&E and issue or not issue an “NTP”.

7.3.a.2 The Government will review the second T&E and issue or not issue an “NTP”.

B. After receiving the first “NTP” the Vendor shall perform all necessary repairs to the S-Band Lewis Scanner cones as determined by the Vendor and described in the first T&E and approved by the Government. The Government shall inspect the repaired scanner cones and determine if the scanner cones are in a like new condition and satisfy the Government’s approved T&E and the cones are ready for attachment on the geodesic lenses of the S-Band Lewis Antenna Assembly. The scanner cones shall be VSWR tested after repair. The VSWR is to be 1.5 to 1.0 or better. The Vendor shall provide a listing of repairs completed and VSWR testing results to the Government in Vendor format ten (10) days after completion of VSWR testing.

C. The Government will inspect the scanner cones. The Government will review the findings of the inspection and to include and to consider the 1st T&E documentation and results of the Government evaluation and instruction and issue or not issue a 2nd “NTP.” If the scanner cones are found by the Government to meet the requirements of the PWS the 2nd “NTP” will be issued to the Vendor for follow on repair of the completed S- Band Lewis Scanner Elevation and Azimuth Antennas. The Government will then ship the scanner, geodesic lenses, asymmetrical horns and reflectors such that two (2) complete S-Band Lewis Scanner antennas can be completely assembled and readied for RF antenna pattern testing after refurbishment. Paragraph 9.0 GFP will also be shipped to the Vendor for the Vendor’s use in offloading, testing, alignment and return shipping of the individual antenna structures and completed antenna assembly.

D. After issuance of a 3rd “NTP” following the second T&E in Paragraph 7.3 the Vendor shall perform all necessary repairs to the scanner, geodesic lenses, asymmetrical horns and reflectors as described in the second T&E and approved by the Government. The Vendor shall notify the Government in writing of the completion of the repairs and when the S-Band Lewis Scanner

Antenna is completely assembled and readied for RF performance testing.

The Government shall inspect the completed work prior to the RF performance testing and antenna alignment.

E. The Vendor shall commence work only after receipt of the Government’s “NTP.” All work shall be documented using Vendor format and provided to the Government.

7.4 The Vendor shall develop a RF performance test plan that provides a complete evaluation of the RF performance of the S-Band Lewis Scanner Antenna. The test plan shall include; but, are not limited to the following:

A. Narrative describing the antenna test range.

B. Method for minimizing reflections from ground if outdoor range is employed.

C. Block diagram of the testing equipment configuration used for the various testing requirements of the PWS.

D. Parameters to be tested: Frequency range, polarization, VSWR, gain, beamwidth, sidelobes, scan sector. All parameters shall be identified and described in detail within the test plan.

E. Fabrication of any mechanical and electrical interface assemblies that are required for RF pattern testing on the Vendor’s range.

F. Description of test report product deliverable indicating the number of antenna patterns to be provided to the government and parameters tested.

Scheduling of tests to be performed on the Vendor’s test range along with the names of personnel that are to be conducting the testing.

G. Equipment calibration certification certificate(s).

H. Schedule of planned testing procedures that support the parametric testing.

I. Two (2) copies of the RF performance test plan shall be provided to the Government fifteen (15) days prior to the third TIM for Government review.

The Government will provide questions and comments to the Vendor for clarification of and possible modifications to the test plan five (5) days after receipt. After Government review of the RF performance test plan and issue or not issue a “NTP.” The Vendor shall commence work after receipt of the Government’s “NTP.”

7.5 The Government shall have the right to attend the Vendor’s testing activities called for in the Vendor’s RF performance test plan and observe all measurements and methods.

8.0 S-Band Lewis Scanner Antenna Pattern Testing Requirements

8.1 The Vendor shall conduct and provide test results in the Vendor’s format documenting the measurement of VSWR, antenna gain, beamwidth, sidelobe (To include comma lobes or shoulders), scan angle, polarization and antenna pattern(s) for the S-Band Lewis Scanner Antennas described in this PWS.

8.2 VSWR, antenna gain, beamwidth, sidelobe, polarization and measurements resulting in a set of antenna patterns and measurement data that can be analyzed on the basis of meeting the general characteristics of Paragraph 6.0 shall be conducted on the following frequencies: 2,900 MHz, 2,950 MHz, 3,000 MHz, 3,050 MHz and 3,100 MHz.

8.3 The antenna pattern of S-Band Lewis Scanner antenna shall be evaluated at eleven (11) scan settings. Those scan settings in degrees are: (-)10, (-)8, (-)6, (-)4, (-)2, 0, (+)2, (+)4, (+)6, (+)8, (+)10. All measurements called for in Paragraph 8.2 shall be made at the scan settings identified for antenna pattern scan evaluation.

8.4 All work shall be documented using Vendor format and provided to the Government as required by this PWS.

8.5 The Vendor shall inform the Government in writing that the S-Band Lewis Scanner antenna test is completed. The Vendor shall provide to the Government the RF performance test results NLT 10 days after notifying the Government of the completion of the testing (SEE PAR 13).

9.0 Government Furnished Property (GFP)

9.1

9.2

9.3

9.4

9.5

9.6

9.7

9.8

9.9

Two (2) antenna support structure will be provided to the Vendor. These support structures shall be used for the buildup of the S-Band Lewis Scanner Antenna Assemblies.

Semitrailer for transport of antenna assemblies PN 583Z4600-809.

One (1) scanner assembly with motor.

Scanner pulse generator assembly PN 583Z4278-3.

One (1) VDC power supply to operate the scanner pulse generator.

Waveguide adapter WR284 to N to mate with the feed on the scanner assembly.

Lifting bar assembly PN 583Z4012-809. This lifting bar is used to lift the various antenna assemblies on-and-off the antenna support structure.

Cable assembly PN 583Z4012-3.

Choker assembly PN 583Z4012-5.

9.10 All GFP shall be returned to TYAD in working condition after completion of work described in this PWS.

10.0 PACKAGING, HANDLING, STORAGE and TRANSPORTATION COSTS

10.1 The Government will bear the transportation costs of the antenna assembly from the Tobyhanna Army Depot, Tobyhanna, PA 1866-5100 to the Vendor’s plant (irrespective of the f.o.b. point or the point of acceptance).

10.2 The Government will create and load onto transport all antenna systems, support structures and other items to be delivered to the Vendor. The transportation company/firm will be responsible for securing the cargo.

10.3 The Vendor shall store the received antenna assemblies, support structures and other items in a secure area to prevent unauthorized access and/or harmful manipulation.

10.4 The Vendor is responsible for the unloading of all antenna systems, support structures and other items that the Tobyhanna Army Depot shipped to the Vendor’s plant (irrespective of the f.o.b. point or the point of acceptance). The Vendor shall find instructions for the unloading, movement and positioning of the S-Band Trough Antenna in TO 43 D7-11-21-2-1. This TO contains information on the use of the lifting bar assembly PN 583Z4012-809, transport trailer, various lifting cables, brackets and attachments necessary for the handling of the S-Band Lewis Scanner Antenna.

10.5 The Vendor shall bear the transportation costs of the antenna assemblies and all other parts, cables, assemblies, support structures and equipment provided to the Vendor by the Government for completing the requirements of this PWS from the Vendor’s plant to (irrespective of the f.o.b. point or the point of acceptance):

Tobyhanna Army Depot 11 Hap Arnold Blvd.

Bldg. 4 bay 6 Attn: Rich Orlowski Tobyhanna, PA 18466-5100

10.6 The Vendor shall be responsible for the preservation, packaging, creating, loading onto transport, securing cargo, transfer in transit, and handling of all items to be delivered under terms of this PWS IAW ASTM D3951-15 and MIL-

STD-2073 -1E.

10.7 The antennas shall be shrink wrapped prior to transport to the TYAD.

10.8 The Vendor shall provide shipping containers constructed to provide for handling and protection of the antenna assemblies and related items. The containers shall provide for the protection (including waterproof barriers for item protection) of the items shipped and the containers closed by banding such that the containers can be opened without damage to the items contained within the container.

10.9 The Vendor shall not use materials that will cause corrosion, static damage or contamination to the antenna assemblies and related items. No material used for packaging, containerizing or shipping shall when removed from the items being shipped using a standard removal technique cause damage to the items.

10.10 The Vendor is responsible for all certifications, permits and exemptions necessary to transport the returning antenna assemblies, support structure and associated parts and equipment when returning and delivering such to the Tobyhanna Army Depot, Tobyhanna, PA 18466 from the U.S. Department of Transportation and Individual State Transportation Departments, as required by federal and state law.

10.11 The Vendor shall notify the Tobyhanna Army Depot in writing NLT fifteen (15) days in advance of the shipment of the antenna assembly, support structure and other related items to the Tobyhanna Army Depot, Tobyhanna, PA. All materials shipped shall be accompanied by a standard commercial packing sheet.

11.0 QUALITY REQUIREMENTS

11.1 The Vendor shall provide the Government with a detailed description of the Vendor’s Quality program and practices.

11.2 The Vendor shall be ISO 9001:2015 compliant and maintain an active certification.

11.3 The Vendor shall prepare and finish the Lewis Scanner Antenna following MIL-

PRF-8525E.

11.4 The Vendor shall:

A. Weld per ANSI/AWS D1.2/D1.2M:2008. (For Aluminum) Welding and brazing symbols per ANSI/AWS A2.4-2012.

B. Weld per ANSI/AWS D1.1/D1.1M:2010. (For Steel) Welding and brazing symbols per ANSI/AWS A2.4-2012.

C. Spot weld per AWS D17.2/17.2M-2007, Class B. Welding and brazing symbols per ANSI/AWS A2.4-2012.

D. All joints shall have continuous water tight welds.

E. All joints and seams shall have continuous water tight welds. And shall be in accordance with AWS D1.2/D1.2M:2008, CLASS B. Welding symbols are per

ANSI/AWS A2.4-2012.

F. Thread dimensions and designations shall be interpreted per ASME B1.1-2003.

11.5 The Vendor shall use materials listed in the Qualified Products List, QPL- 81706.

11.6 Rust, corrosion, physical damage and finish paint shall be re-worked to like new conditions. Check for corrosion on the antenna assembly and all its’ components to include bolts and scanner mounting interface. Clean as needed and coat with an iridite that is on Qualified Products List, QPL -81706.

A. Repair or replace all damaged antenna assembly hardware such as the mounting bolts, mounts, scanner interface, or lifting rings. Repairs to the antenna reflective surface such as scratches, breakage or dents shall be accomplished using a material having reflective characteristics similar to the antenna reflector so as not to degrade antenna electrical performance.

Identification of defective hardware and its replacement shall be of a similar type not compromising the mechanical performance of the antenna.

Replacement of radome material shall be of a similar type not degrading RF performance. Any material used to make antenna assembly repairs shall be thermally compatible with the existing material so that thermal cycling in the outdoor environment does not cause the repair to separate.

12.0 DELIVERABLES

12.1 The following is the Delivery Information Schedule:

A. DELIVERY DATE QUANITY ITEM

240 DACA One (1) PN: 583Z5001MC-1

B. 240 DACA One (1) PN: 583Z5001MC-3

C. 15 Days ARM SEE PAR 7.0 One (1) First T&E Report

10 Days After Completion of Antenna Cone Repair and Testing SEE PAR 7.3.B One (1) Scanner Cone Repair and VSWR Test Report.

D. 15 Days ARM SEE PAR 7.0 One (1) Second T&E Report

E. 15 Days Prior to TIM 3 Two (2) CPYs RF Performance Test Plan

SEE PAR 5.2.C7.4. & 13.0.

F. 10 Days After Completion of Antenna Assembly and RF Testing Two (2) CPYs RF Performance Test Results; SEE PAR 8.0 & 13.0.

G. TIM 1 10 Days After 1st T&E TIM 1 and Documentation SEE PAR 4.8 & 5.0

H. TIM 2 10 Days After 2nd NTP TIM 2 and Documentation SEE PAR 4.8 & 5.0

I. TIM 3 25 Days after 3dr NTP TIM 3 and Documentation SEE PAR 4.8 & 5.0

NOTE: The Vendor shall ship the antenna assembly, associated parts, GFP and antennas to the Ship To Address only after the data and final report has been reviewed and approved by the Government.

Ship to address:

Tobyhanna Army Depot 11 Hap Arnold Blvd.

Bldg. 4 bay 6 Attn: Rich Orlowski Tobyhanna, PA 18466-5100

13.0 PERFORMANCE REQUIREMENTS SUMMARY

Performance Objective

PWS

Para

Performance Threshold

Method of Surveillance

Monitoring Performed by

/date(s)

TIM 1

Conduct and Report

5.0 100% on conducting meeting and providing report

Attendance at TIM / Review of report

COR - As scheduled during contract performance

TIM 2

Conduct and Report

5.0 100% on conducting meeting and providing report

Attendance at TIM / Review of report

COR - As scheduled during contract performance

TIM 3

Conduct and Report

5.0 100% on conducting meeting and providing report

Attendance at TIM / Review of report

COR - As scheduled during contract performance Test and Evaluation

Report #1

7.3 100% on delivery of report Review of report COR - As scheduled during contract performance

Test and Evaluation Report #1

7.3 100% on delivery of report

Review of report COR - As scheduled during contract performance RF Performance

Test Results

8.0 100% on delivery of report Review of report COR - As scheduled during contract performance

The COR will provided a copy of the Quality Assurance Surveillance Plan to the contractor at the time of contract award.

14.0 FINAL INSPECTION AND/OR ACCEPTANCE

14.1 Inspection will be by the Government at the Vendor’s facility first for S-Band Lewis Scanner Cones and secondly for the completely assembled S-Band Lewis Scanner Elevation and Azimuth Antenna Assemblies.

14.2 Acceptance for the completely assembled S-Band Lewis Scanner Elevation and Azimuth Antenna Assemblies will be by the Government at destination TYAD, PA 18466.

14.3 All GFP shall be returned to the Government. The GFP will be inspected upon delivery to TYAD. The Government will accept delivery of the GFP if and only if the GFP is returned to the Government without damage.

14.4 Scanner Cones: The two (2) S-Band Lewis Scanner cones (PN: 583Z5001MC-1

& PN: 583Z5001MC-3 shall be made available to the Government for inspection at the Vendor’s facility.

A. The Government will inspect items such as scanner cone reflective metal tape, RF absorber attached to the supporting sidewalls of the waveguide, interior metal skins where accessible, iridite coating, all metal surfaces will be inspected for mechanical damage, corrosion, uniform thickness, metal fatigue, cracks, metal surface bulges, weld separations, metal and other mechanical conditions. In addition to the mechanicals and chemical treatments, VSWR testing will be measured and documented by the Vendor. The Government will witness the VSWR testing and review all mechanical and electrical documentation at the time of inspection.

B. If the scanner cones are found by the Government to meet the requirements of the PWS a “NTP” will be issued to the Vendor for follow-on repair for the complete S-Band Lewis Scanner Elevation and Azimuth Antennas. The Government will review the findings of the inspection and issue or not issue a “NTP”. At an issuance of an “NTP” the Government will make shipment of the GFP to the Vendors facility, See Paragraph 9.0. If the Government does not issue an NTP the Government will provide instruction to the Vendor on shipping back the scanner cones to TYAD.

C. Inspections will be at time, date and location mutually agreed upon by the Vendor and Government.

D. Acceptance will be at time, date and location mutually agreed upon by the Vendor and Government within the TYAD. This is a general Acceptance and does not constitute Final Acceptance.

14.5 Completed Antenna Assembly: Final inspection and acceptance of the S-Band Lewis Scanner Azimuth Antenna PN: 583Z5001MC-1 and S-Band Lewis Scanner Elevation Antenna PN: 583Z5001MC-3 is contingent upon satisfactory completion of in-plant overhaul, inspections, testing and antenna pattern measurements and submittal of those Vendor documents affirming completion of overhaul and testing to the Government for review and approval.

The Tobyhanna Army Depot will provide in writing comment to the Vendor NLT ten (10) business days after receipt of documents. The Vendor shall ship the completed antenna assemblies and GFP to the Tobyhanna Army Depot after receipt of the Government’s NTP. The following shall be provide prior to delivery of the antenna assemblies:

A. Documented testing results for VSWR, antenna gain, beamwidth, sidelobe, scan angle, polarization and antenna pattern(s) for the S-Band Lewis Scanner Antennas described in this PWS.

B. The Vendor shall prepare and submit to the Government a Material Inspection and Receiving Report (MIRR), DD Form 250, after all contractual requirements are met. The DD Form 250 shall be provide to the Government at time of antenna assembly and GFP delivery at the Tobyhanna Army Depot.

C. The Government reserves the right to observe the Vendor’s overhaul, testing and alignment of the antenna assembly at the Vendor’s plant and antenna range prior to the submission to and acceptance by the Government of the DD Form 250.

15.0 TOBYHANNA ARMY DEPOT POCs

15.1 COR - Rick Saunders: Electronics Engineer

ricky.saunders.civ@mail.mil

TEL: (570)-615-6356

A COR appointment letter will be provided to the Contractor after award.

16.0 CONTRACTOR MANPOWER REPORTING APPLICATION (CMRA)

The Office of the Assistant Secretary of the Army (Manpower & Reserve Affairs) operates and maintains a secure Army data collection site where the contractor shall report ALL contractor manpower (including subcontractor manpower) required for performance of this contract. The Army's objective is to collect as much significant Contractor Man-Year Equivalents (CME) data as possible to allow accurate reporting to Congress and for effective Army planning. Detailed instructions can be found on the Contractor Manpower Reporting Application (CMRA) website in the CMRA “Contractor User Guide” or “Subcontractor User Guide”. The contractor shall create an account upon entering the site and is required to completely fill in the required information at the CMRA website: https://cmra.army.mil.

The required information includes:

(1) Unit Identification Code (UIC) of the Army Requiring Activity that would be performing the mission if not for the contractor: __________ (Enter the Army Requiring Activity’s UIC here).

(2) Command of the Requiring Activity that would be performing the mission if not for the contractor: __________ [Enter the Major Command (MACOM) of the Requiring Activity here].

(3) Contracting Officer (KO) and contact information:

(Enter KO’s name, phone number, and email address).

(4) Contracting Officer’s Representative (COR) and contact information:

(Enter COR’s name, phone number, and email address).

(5) Federal Service Code (FSC) reflecting services provided by contractor (and separate FSC for each subcontractor if different). If there are multiple FSCs for an Order number, enter a separate data record for each FSC.

(6) Location where contractor and subcontractor(s) perform the service, including the city, state, zip code, and country. When service is performed at an overseas location, state only the city and country. If there are multiple Locations for an Order number, enter a separate data record for each Location. (Note: If there are many location records that need to be entered, the

W25G1V-18-R-0008 Attachment I mailto:paul.v.roberts.civ@mail.mil https://cmra.army.mil/

Bulk Loader function is available which allows the transfer of information from a contractor’s system to the secure web site. The Bulk Loader Template and Bulk Loader Instructions may be downloaded from the web site.)

(7) Contractor Type (prime or subcontractor).

(8) Direct labor hours (including subcontractors) for each FSC.

(9) Direct labor dollars paid this reporting period (including subcontractors) for each FSC.

(10) Weapons system support indication: __________ (Enter yes or no).

If subcontractors are used in the performance of this contract, several factors shall be considered. Contractor shall include, and require inclusion of, this term in all subcontracts at any tier under the contract in which services are being procured.

Contractor shall also enter their data in a timely manner, as subcontractors cannot input any information into the CMRA system until the Prime Contractor has entered their data.

The Prime Contractor has overall responsibility for ensuring subcontractors enter their respective data. Subcontractors are only responsible for entering Location Data.

Reporting period will be the period of performance not to exceed 12 months ending 30 September of each government fiscal year and shall be reported by 31 October of each calendar year.

17.0 DEPOT ACCESS FOR THE CONTRACTOR:

A background check and approval from Tobyhanna Army Depot (TYAD) Law Enforcement is required for all contractor and subcontractor personnel prior to on-site access at TYAD. All persons seeking entrance to TYAD shall submit to and comply with all security standards and requirements in force at the time such persons are seeking entry. All contractors, regardless of resident status or citizenship, will be subject to vehicle search and intense in-processing by TYAD security personnel prior to being granted access to TYAD. This security screening process may be time consuming and access may be delayed or denied. The contractor shall ensure ELTY Form 648-C is completed for all contractor and subcontractor personnel requiring depot access to include warranty services. The TYAD point of contact (POC) will provide ELTY Form 648-C, “Request Access to Tobyhanna Army Depot” to the contractor/vendor at least ten days prior to the expected visit date for completion. The contractor/vendor shall return the completed ELTY Form 648-C to the TYAD POC in a timely manner so the same may be submitted to Security for processing no later than seven days prior to the visit. All of the required fields on the form shall be complete and accurate by the contractor/vendor for timely processing. This requirement is inclusive of on-site supervisory or managerial personnel and sub-contractor personnel that the Contractor anticipates will be performing work or visiting on-site. This security screening does not relieve the contractor of any responsibilities to conduct thorough pre-employment background checks and drug screening. Contractor workers will not be granted access to the work site until security screening is completed and access is approved. Any contractor personnel on-site who fail screening will not be permitted further access to TYAD. See “Access and General Protection/Security Policy and Procedures.”

Access and General Protection/Security Policy and Procedures. Contractor and all associated sub-contractors employees shall comply with applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative). The contractor shall also provide all information required for background checks to meet installation access requirements to be accomplished by TYAD Security Branch. Contractor workforce must comply with all personal identity verification requirements as directed by DoD, HQDA, and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any individual facility or installation change, the Government may require changes in contractor security matters or processes.

Contractor and all associated sub-contractors employees shall comply with adjudication standards and procedures using the National Crime Information Center Interstate Identification Index (NCIC-III) and Terrorist Screening Database (TSDB) (Army Directive 2014- 05/AR 190-13), applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by the government representative), or, at OCONUS locations, in accordance with status of…