Attachment 9 Material Safety Data Sheet Iron Alloy Foils No Restriction.pdf
PDF 180 KB Posted
- Solicitation number
- W15QKN-19-R-0133
About this file
This document contains a material safety data sheet and related federal contract solicitation. The material safety data sheet provides safety information for activated iron/iron alloy foils, identifying it as a pyrophoric metal requiring special handling and storage precautions.
Solicitation W15QKN-19-R-0133 is for the production, testing, inspection, packaging and delivery of M211 infrared countermeasure decoys and MJU-50A/B and MJU-51A/B infrared countermeasure flares. These products are part of the family of advanced infrared countermeasures used to protect Army and Air Force aircraft from infrared-seeking missile threats by generating decoying infrared energy. The solicitation references associated technical data packages and specifications listed in Section J as attachments. The Department of the Army Materiel Command Contracting Command Picatinny Arsenal is the issuing agency.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Material Safety Data Sheet U.S. Department of Labor
May be used to comply with Occupational Safety and Health
Administration
OSHA's Hazard Communication Standard, (Non-Mandatory Form)
29 CFR 1910.1200. Standard must be Form Approved consulted for specific requirements. OMB No. 1218-0072
IDENTITY (As Used on Label and List) Activated Iron/Iron Alloy Foils
Note: Blank Spaces are not permitted. If any item is not applicable, or no information is available, the space must be marked to indicate that.
Manufacturer's Name Alloy Surfaces Company, Inc.
Emergency Telephone Number 1-800-424-9300
Address (Number, Street, City, State, and ZIP Code) 121 N. Commerce Drive
Telephone Number for Information
(610) 497-7979
Chester Township, PA 19014 Date Prepared March 31, 1992
Signature of Preparer (optional)
Section II - Hazard Ingredients/Identity Information
Hazardous Components (Specific Chemical Identity, Common Name(s)).
OSHA
PEL
ACGIH TLV
Other Limits
Recommended % (optional)
Active Metal: Sponge Metal
Contains Fe, Al, Sn, Ta, Mn
Proper shipping name: Pyrophoric metal (activated Iron)
Hazard Class: 4.2
ID#: UN1383
DOT Label: “Spontaneously Combustible”
Section III - Physical/Chemical Characteristics
Boiling Point N/A Specific Gravity (H2O = 1) Approx. 4
Vapor Pressure (mm Hg.) N/A Melting Point N/A
Vapor Density (AIR = 1) N/A Evaporation Rate
(Butyl Acetate = 1)
N/A
Solubility in Water Insoluble in water
Appearance and Odor Grey to black, dull finish, no odor
Section IV - Fire and Explosion Hazard Data
Flash Point (Method
Used)
Flammable Limits LEL UEL
Extinguishing Media Water, CO2, foam to deactivate and quench
Special Fire Fighting Procedures
Unusual Fire and Explosion Hazards: Activated Iron is pyrophoric. When exposed to air, it attains red heat quickly and provides a combustion source for exposed combustible materials. It is highly reactive with organic compounds when heated or exposed to oxidizing agents. Some hydrogen may be evolved during shipping or storage. Open flames and smoking prohibited.
(Reproduce locally) OSHA 174, Sept. 1985
Section V - Reactivity Data
Stability Unstable x Conditions to Avoid. Air-Sensitive Material. Some Hydrogen will be evolved during storage.
Stable
Incompatibility (Materials to Avoid). Reacts with strong acids to liberate hydrogen. Reacts vigorously with strong oxidizing agents.
Hazardous Decomposition Byproducts. Hydrogen may be evolved.
Hazardous Polymerization
May Occur Conditions to Avoid
Will Not
Occur x
Health Hazard Data
Route(s) of Entry: Inhalation? Yes Skin? Yes Ingestion? Yes
Health Hazards (Acute and Chronic) N/A
Carcinogenicity: NTP? N/A IARC Monographs?
N/A
OSHA Regulated? N/A
Signs and Symptoms of Exposure Skin – May cause skin irritation
Medical Conditions
Generally Aggravated by Exposure N/A
Emergency and First Aid Procedures. Wash skin with soap and water.
Section VII - Precautions for Safe Handling and Use
Steps To Be Taken In Case Material Is Released Or Spilled. Should be flushed with water.
Contaminated cleaning materials should be considered pyrophoric.
Waste Disposal Method Expose to air. Material will burn and become deactivated Residue consists of iron and iron oxides which are not hazardous and may be discarded. Disposal must be in accordance with federal, state, and local Regulations.
Precautions to be Taken in Handling and Storage. Keep away from heat, sparks, and open flames. Handle and store under nitrogen or inert gas.
Other Precautions
Section VIII - Control Measures
Respiratory Protection (Specify Type) OSHA/MHSA Approved
Ventilation Local Exhaust Special
Mechanical (General) Metal or heat resistant container for disposal
Other
Protective Gloves Heat resistant Eye Protection Safety goggles
Other Protective Clothing or Equipment
Work/Hygienic Practices
Page 2 * U.S.G.P.O.: 1986 – 491 - 529/45775