About this file
The document is a product specification and ordering guide for Von Duprin's 6100 Series Electric Strikes for Rim Exit Devices, manufactured by Allegion. The comprehensive technical document details electric strike models (6111, 6112, 6113, 6114, and 6121) designed for use with various rim exit devices in single and double door configurations. The strikes are compatible with multiple manufacturers' exit devices, including Von Duprin, Falcon, Precision, Sargent, and Yale, and are suitable for hollow metal, aluminum, and wood door/frame types. Key features include heavy-duty stainless steel construction, UL 1034 listing for burglary-resistant electric door strikes, UL 10C 3-hour fire rating for select models, and static strength of 1500 lbs.
The product offers multiple configuration options, including fail-secure and fail-safe modes, dual monitor switches, entry buzzer, and Allegion Connect wire extension. Power requirements include 12V and 24V DC options, with continuous duty ratings. Finish options range from plated brass and bronze to stainless steel in various sheens. While not directly related to a specific government contract, the product specification sheet provides detailed technical information that could be applicable to the FSU Charter School ADA Access Controls project, which requires access control components. The document includes comprehensive wiring diagrams, dimensional specifications, and a detailed ordering guide to help users select the appropriate electric strike for their specific application.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VonDuprin.com
6100 Series Strikes for Rim Exit Devices
Von Duprin electric strikes are known for their reliability, durability and security. The 6100 Series strikes are designed to withstand abuse. Their heavy-duty stainless steel construction is UL1034 listed.
6100 Series electric door strikes are designed for use with a variety of rim exit devices including rim nightlatch. Electrified strikes allow remote release of a locked door by activating a movable lip (keeper) using an entry/exit button or credential reader and can be a cost effective means for managing access. 6100 Series strikes come standard as 24 VDC in fail secure mode. 12 VDC and AC operation can be selected, as can fail safe mode and other options that enable you to configure these strikes to fit your exact needs.
Use 6100 Series electric strikes for retrofit applications or new construction. To assure the proper selection of an electric strike on new applications, lockset compatibility charts are shown on the next page. When using a lockset not listed or if retrofitting a strike to an existing application, please contact Von Duprin technical support for application assistance.
• Five configurations available for rim exit and nightlatch devices
• Heavy-duty stainless steel construction
• Strike box allows horizontal adjustment to compensate for misalignment of the door or frame
• 24 VDC standard with 12 VDC and AC operation optional
• Two-piece plug connectors are furnished for ease of installation and removal during strike servicing
• Options include rectifier kit for VAC to VDC conversion, dual monitor switches, entry buzzer and Allegion Connect wire extension
• Six popular finishes available to suite with existing hardware
• UL 10C 3-hour fire-rated electric strike (models 6111, 6112 and 6113 – fail secure only)
• UL 1034 listed for burglary-resistant electric door strikes
• Static strength: 1500 lbs
• Dynamic strength: 70 ft-lbs
• UL 294 listed for access control system
Overview Features & Benefits
*With manufacturer’s mullion.
Note: 16 VDC and 28 VDC solenoid are sold as replacement parts for existing strikes. Please contact customer care for details.
Strikes for Rim Exit Devices 6100 Series
1. Strike must be factory modified, specify when using with a 55 Rim device.
2. Deadlocking feature will not properly function, consult factory.
3. Panic only, not fire-rated.
4. 6111 is recommended for LBR applications.
Note: When using a lockset not listed or when retrofitting an existing application, please contact Von Duprin technical support for application assistance.
Model Specifications
Model number 6111 6112 6113 6114 6121
Retrofits model VD 3031 FA 310-4 VD 3011
VD 3021
FA 310-5 FA 310-4-100
Latchbolt throw 3⁄4" 3⁄4" 3⁄4" 3⁄4" 3⁄4"
Face plate length 6" 9" 6" 7-1⁄2" 9-1⁄8"
Backbox depth 1-5⁄8" 1-11⁄16" 1-15⁄16" N/A N/A
Lockset Rim exit device Rim exit device Rim exit device Rim nightlatch Rim exit device
Number of doors
Single • • • • ---
Double door with mullion
Double door without mullion
Door/frame type
Hollow metal • • • • • Aluminum • • • • • Wood • • • --- •
Options Blade stop shim Yes No Yes No No
DS or DS-LC (dual monitor switches)
Yes Yes Yes Yes Yes
EB (entry buzzer -fail-secure only)
Yes Yes Yes Yes Yes
Certifications/ Listings
UL 1034 • • • • •
UL 10C Single Door 3 hour 3 hour 3 hour --- ---
UL 10C Pair Door* 90 Minutes 90 Minutes 90 Minutes --- ---
Application notes 1 2 3 4 5
Application notes:
1. 1⁄2" projection blade stop shim 010055-XX available for use on cased opening or blade stop frames. Specify when using 55 rim devices. May also be used with vertical rod exit devices noted on previous page x Pullman latch LBR (non-fire rated).
2. When used to replace Folger Adam 310-4, minor fame prep modification required.
3. 1⁄2" projection blade stop shim 010055-XX available for use on cased opening or blade stop frames (non-fire rated).
4. Surface applied strike designed to replace Folger Adam 310-5 with different mounting hole locations from Folger Adam.
5. Designed to mount on inactive leaf.
Rim Exit Device Compatibility for 6111, 6112, 6113 and 6121 Strikes Manufacturer Device
Von Duprin 22, 33A, 35A, 551, 88, 98, 99 8827 LBR4 x Pullman latch Non-Fire rated 9827 LBR4 x Pullman latch Non-Fire rated 9927 LBR4 x Pullman latch Non-Fire rated
Falcon2 19-R, 24-R, 25-R
Falcon 1790
Precision2 2100
Sargent 2800, 6500, 6800, 8500, 8800, 9500, 98003, 9898
Yale 1500, 700
6" (152 mm)
1 5/8" (41 mm)
7/8" (22 mm)
1/2"
2 3/16"
1 3/8"
13/16"
1 5/8"
4 1/2"
Minimum Clearance
(13 mm)
(41 mm)
(56 mm) (114 mm)
(35 mm)
(21 mm)
1 5/8" (41 mm)
9" (229 mm)
7/8" (22 mm)
3/4" (19 mm)
2 9/16" (65 mm)
Minimum Clearance 9/16"
(14 mm)
4 1/2" (114 mm)
1 5/8" (41 mm)
1 11/16" (43 mm)
7/8" (22 mm)
1 5/8" (41 mm)
2 1/2" (64 mm)
9 1/8" (232 mm)
7/8"
6"
1 5/8" (41 mm)
(152 mm)
(22 mm)
Minimum Clearance
7/8" (22 mm)
9/16" (14 mm)
1 15/16" (49 mm)
4 1/2" (114 mm)
1 3/8" (35 mm)
2 1/4" (57mm)
Wiring
Dimensions
AC
AC with buzzer
DC
DC with Buzzer
Optional DS (FSE Shown)
Continuous duty = Energized 1 minute or more
Strike Dimensions
Frame Preparation for Strike
931243_00 Rev. 5/12-b
RH door shown
#25 drill and #10-24 tap 4 places
1/2” diameter hole for wiring access
2 places
Edge of frame
3”
6”
15/16”
6-5/8”
1”
7/16”
Edge of frame
1”
3-5/16” 7-1/2”
7/16”
1-15/16”
6-5/8”
1-5/8”
1-7/8”
3-3/4”
C of latchL
C of strikeL
1”
3-3/32”
1-9/16”
C strikeL 3-5/16”
Strikes for Rim Exit Devices 6100 Series
6100 Series Power Requirements Models Voltage Current Duty Amps Ohms All 12V DC Continuous 0.60 21 All 24V DC Continuous 0.33 83
VonDuprin.com
1 Model
Reference specification chart to make the proper model selection
2 Power failure mode FSE Fail-secure. Requires power to be applied to unlock the strike lip. On loss of power, the strike lip is locked. Fire-rated.
FS Fail-safe. Requires power to be applied to lock the strike lip. On loss of power, the strike lip is unlocked. Non-fire-rated.
3 Dual switch (optional) DS Monitors latch bolt and lock status. DS switches rated for 24 VDC at .050-2.0 amps.
DS-LC Low current option for computer monitoring.
Monitors latch bolt & lock status. DS-LS switches rated for 24 VDC at .050 amp or less.
4 Voltage (VDC) 24 Low voltage DC power
12 Low voltage DC power
Selections correspond with the numbers above.
If AC power is required, specify rectifier kit.
5 Rectifier kit (optional) S012 Converts 12 VAC voltage to 12 VDC to operate the solenoid S024 Converts 24 VAC voltage to 24 VDC to operate the solenoid 6 Finish US3/BHMA 605 Plated polished brass on stainless steel
US4/BHMA 606 Plated satin brass on stainless steel
US10/BHMA 612 Plated satin bronze on stainless steel
US10B/BHMA 613 Plated dark bronze, oil rubbed on stainless steel
US32/BHMA 629 Stainless steel, polished
US32D/BHMA 630 Stainless steel, satin
7 Buzzer (optional) EB Entry Buzzer
Only available if Fail-Secure (FSE) is specified.
8 Allegion Connect CON Allegion Connect Connector
6 in. wire extension harness available
Strikes for Rim Exit Devices 6100 Series
© 2024 Allegion plc 005282, Rev. 01/24
Ordering Information
1 2 3 4 5 6 7 8
M od el
Po w er fa ilu re m od e
D ua l s w itc h*
Vo lta ge
Re ct ifi er k it*
Fi ni sh
Bu zz er
Al le gi on
C on ne ct
6112 - FSE - DS - 24 - S024 - US3 - EB - CON
* Optional