ADA_Access_Controls_at_FSU_Charter.pdf
PDF 3 MB Posted
- Attached to
- FSU Charter School ADA Access Controls
- Solicitation number
- PSPW-24-08
- Issued by
- Broward County, Florida
About this file
These electrical plan documents are for the Pembroke Shores Charter School Access Control project located at 501 SW 172nd Avenue in Pembroke Pines, Florida, prepared by INGEMEL S.A. engineering firm. The scope of work consists of installing five (5) new electrical outlets for door access control systems across Buildings A, B, and C on the first and second floors. The project involves integrating these new access control systems with the existing access control infrastructure of the school, with the electrical contractor responsible for coordinating all work with the City of Pembroke Pines Project Manager.
The electrical plans detail specific technical requirements including compliance with multiple building codes such as the Florida Building Code (8th Edition - 2023), Florida Fire Prevention Code, National Electrical Code (2020 Edition), and other relevant standards. The electrical specifications mandate that all new equipment be installed according to manufacturer recommendations, all conductors be copper with appropriate insulation, conduits meet specific material requirements, and all work be guaranteed free from defects for one year from final acceptance. The project drawings include detailed electrical symbols, panel schedules, key notes, and site plans showing the precise locations of the proposed access control system modifications.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BRANCH CIRCUIT HOMERUN TO PANEL BOARD
NUMBER INDICATE CIRCUIT DESIGNATIONP-XX
ELECTRICAL SYMBOLS
EXISTING ELECTRICAL PANEL
JUNTION BOX
ELECTRICAL KEY NOTES
1 ALL WORK SHALL BE COORDINATED WITH CITY OF PEMBOKE PINES
PROJECT MANAGER.
2 ALL WORK SHALL BE PERFORMED IN A CLEAN MANNER. ALL WORK
SHALL BE COORDINATED WITH OWNER'S PROJECT MANAGER TO
MINIMIZE ANY DISTURBANCE TO OTHER AREAS OF THE BUILDING
WHICH ARE TO REMAIN IN OPERATION.
3 THESE DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND
REPRESENT EXISTING CONDITIONS BASED ON AVAILABLE
DRAWINGS AND SITE OBSERVATIONS. CONTRACTOR IS
RESPONSIBLE FOR FIELD VERIFICATION OF ALL ACTUAL
CONDITIONS, FOR EXACT LOCATIONS AND SIZES OF PIPING,
CONDUIT, WIRES, EQUIPMENT, ETC.
4 EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE.
WORK DAMAGED BY THE CONTRACTOR SHALL BE REPAIRED TO
MATCH EXISTING WORK.
5 NEW JUNCTION BOX ON TOP OF THE DOOR FOR THE INSTALLATION
OF A NEW ACCES DOOR CONTROL SYSTEM. ELECTRICAL
CONTRACTOR SHALL COORINATE THE LOCATION WITH ACCES
CONTROL SYSTEM CONTRACTOR (TYPICAL).
SCOPE OF WORK
THE SCOPE OF WORK OF THIS PROJECT CONSISTS OF THE ADDITION OF
FIVE ELECTRICAL OUTLETS FOR THE INSTALLATION OF FIVE (5) NEW DOOR
ACCESS CONTROL.
THE INSTALLATION OF THE DOOR ACCESS CONTROL AND THE
INTEGRATION OF THEM TO THE EXISTING ACCES CONTROL SYSTEM OF THE
SCHOOL WILL BE THE CONTRACTOR'S RESPONSABILITY. THE DOOR
ACCESS CONTROL CONTRACTOR SHALL COORDINATE ALL WORK WITH
CITY OF PEMBROKE PINES PROJECT MANAGER.
J
BUILDING CODE: FLORIDA BUILDING CODE - 8TH EDITION - 2023
FIRE/LIFE SAFETY CODE: FLORIDA FIRE PREVENTION CODE - 8TH EDITION -
ENERGY CODE: FLORIDA ENERGY CONSERVATION CODE - 8TH
EDITION-2023
NFPA 70: NATIONAL ELECTRICAL CODE - 2020 EDITION
NFPA 72: NATIONAL FIRE ALARM CODE - 2019 EDITION
NFPA 101: LIFE SAFETY CODE - 2021 EDITION
CODE REQUIREMENTS SHALL BE INCLUSIVE OF ALL ADDENDUMS AND
CLARIFICATIONS ISSUED UP TO THE TIME WHEN THE BUILDING PERMIT IS
GRANTED. THE LISTED CODES AND PERMIT STANDARDS SHALL NOT BE
CONSTRUED TO BE THE ONLY APPLICABLE CODES AND STANDARDS
GOVERNING THIS PROJECT. THE GENERAL CONTRACTOR, ALL
SUB-CONTRACTORS AND SUPPLIERS SHALL VERIFY AND ADHERE TO THE
REQUIREMENTS OF ALL OF THE CODES AND STANDARDS THAT GOVERN
AND PERTAIN TO THEIR PRESCRIBED SCOPE OF WORK.
APPLICABLE CODES
ELECTRICAL NOTES
1. ALL NEW EQUIPMENT INSTALLED IN THIS PROJECT SHALL BE INSTALLED IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDED INSTALLATION INSTRUCTIONS.
2. CONTRACTOR TO ASSURE THAT PROPER CLEARANCE (AS PER MANUF.
RECOMMENDATIONS) IS PROVIDED AROUND ALL NEW EQUIPMENT FOR SERVICING
AND REPLACEMENT PURPOSES.
3. EQUIPMENT VOLTAGES SHALL BE VERIFIED PRIOR TO ANY INSTALLATION.
4. ANY CHANGES FROM DESIGN SHALL REQUIRE THE CONTRACTOR TO PREPARE A
WRITTEN REQUEST FOR SAID CHANGE WHICH WILL BE SENT TO OWNER'S
REPRESENTATIVE FOR REVIEW.
5. ALL MATERIALS SHALL BE NEW AND BEAR UNDERWRITERS' LABELS WHERE
APPLICABLE.
6. ALL CONDUCTORS SHALL BE COPPER WITH THW/THWN INSULATION. ALL
CONDUCTORS #10 AND SMALLER MAY BE SOLID. ALL CONDUCTORS #8 AND LARGER
SHALL BE STRANDED TYPE. ALL CONDUCTORS SHALL BE IN CONDUIT. OUTDOOR
UNDERGROUND CONDUITS SHALL BE IN PVC SCHEDULE-40., MINIMUM COVER SHALL
BE 18". OUTDOOR ABOVEGROUND CONDUITS SHALL BE RIGID. INTERIOR EXPOSED OR
CONCEALED CONDUIT SHALL BE EMT. STEEL SET-SCREW FITTINGS. ALL WIRING
INSTALLATION SHALL BE MADE AS REQUIRED BY NEC Art. 300.
7. THE WORK INCLUDED CONSISTS OF ALL SUPERVISION, LABOR, MATERIALS,
EQUIPMENT FACILITIES, AND INSTALLATION REQUIRED FOR THE COMPLETE
SATISFACTORY AND APPROVED ELECTRICAL SYSTEM AS INDICATED ON THE
DRAWINGS AND CALLED FOR IN THIS SPECIFICATION, OR AS MAY BE REASONABLY
IMPLIED BY EITHER.
8. LABEL ALL EQUIPMENT (DISCONNECT SWITCHES, CIRCUIT BREAKERS, CONTROLS
ETC.) WITH ENGRAVED LAMINATED PLASTIC.
9. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTING.
CONTRACTOR SHALL OBTAIN PERMITS AND APPROVED SUBMITTALS PRIOR TO
BEGINNING WORK OR ORDERING EQUIPMENT.
10. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS. CAST ALLOY WITH
THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR
OTHER CLASSIFIED AREAS.
11. ELECTRICAL SYSTEM SHALL BE COMPLETE AND EFFECTIVELY GROUNDED AS PER
N.E.C ART. 250.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED
OF HIS WORK.
13. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND VERIFY WITH OTHER
TRADES PRIOR TO PROCEEDING WITH ANY WORK. WHERE DISCREPANCIES OCCUR
BETWEEN THESE DOCUMENTS AND ACTUAL CONDITIONS, THE DISCREPANCY SHALL
BE REPORTED TO OWNER'S REPRESENTATIVE FOR EXPEDITING AND RESOLUTION.
14. ALL ELECTRICAL CIRCUITS SHALL BE IDENTIFIED AND LABELED IN THE ELECTRICAL
PANEL.
15. THE CONTRACTOR IS REFERRED TO THE MECHANICAL PLANS AND SPECIFICATIONS.
SUCH PLANS AND SPECIFICATIONS ARE TO BE CONSIDERED PART OF THE ELECTRICAL
CONTRACT DOCUMENTS.COORDINATE WITH INTERIOR DESIGNER AND/OR ARCHITECT
FOR EXACT LOCATION AND HEIGHT OF ELECTRICAL OUTLETS.
16. ALL WORK SHALL BE GUARANTEED FREE FROM DEFECTS FOR A PERIOD OF ONE
YEAR FROM DATE OF FINAL ACCEPTANCE.
17. THE ELECTRICAL INSTALLATION SHALL MEET THE APPROVAL OF THE OWNER'S
REPRESENTATIVES BEFORE ACCEPTANCE.
18. LABEL ALL JUNCTION BOXES ABOVE CEILINGS AND IN WALLS WITH PANEL
DESIGNATION AND CIRCUIT NUMBER.
19. SUPPORT ALL BOXES AND CONDUIT ABOVE CEILING INDEPENDENTLY. DO NOT
SUPPORT ANY BOX OR CONDUIT FROM SUSPENDED CEILING SYSTEM.
20. INSTALL ALL EXPOSED CONDUIT AND WIREWAYS PARALLEL AND PERPENDICULAR TO
BUILDING SURFACES.
21. ELECTRICAL EQUIPMENT SHALL BE LISTED AND LABELED FOR THE QUALIFIED USE.
ELECTRICAL
ROOM
ELEV.
LOBBY
BREEZEWAY
WAITING
GR-2
CLASSROOM
MEDIA
RESOURCE
GR-2
CLASSROOM
MULTI
PURPOSE
BUILDING
A
BUILDING
B
J
EXISTING
PANEL LKB
LOCATION
J
J
LKB-12
LKB-12
LKB-14
D1
D3
D2 5
APPROVED:
DRAWN:
SCALE :
OF:
PROJECT NO.:
DWG FILE:
DATE:
DATEREV No. DESCRIPTION
This drawing and the information and design application herein contained is property of INGEMEL S.A. The information contained herein may not be used or reproduced in any manner without written permission of INGEMEL S.A.
LEGENDS:
SHEET:
SHEET No.:
CONTENTS:
PROJECT ADDRESS:
PROJECT:
P.E. SEAL
TO THE BEST OF OUR KNOWLEDGE THE
PLANS AND SPECIFICATIONS COMPLY WITH
THE APPLICABLE MINIMUM BUILDING CODE
20871 Johnson Street, Suite 115 Phone: (954) 318-2264 Fax: (954) 450-7216
Pembroke Pines, Florida 33029
State of Florida CA No. 9113
PEMBROKE SHORES
CHARTER SCHOOL
ACCESS CONTROL
501 SW 172nd Avenue
Pembroke Pines, FL 33029
INDICATED 08-15-24
24-108
09-24-24 ISSUED FOR PERMIT-
ELECTRICAL PLAN
BLDG A & BLDG B
1ST FLOOR
G. PACHECO 24-108E1
P. ARIAS
E -1
1 2
Pedro Arias, P.E.
Florida Registration. No. 63813
SCALE: 3/16" = 1'-0"
ELECTRICAL PLAN - BLDG A & BLDG B - 1ST FLOOR
N.T.S.
SITE PLAN
N.T.S.
KEY PLAN
BUILDING
B
BUILDING
A BUILDING
C
AutoCAD SHX Text
WH
AutoCAD SHX Text S7
ELECTRICAL KEY NOTES
1 ALL WORK SHALL BE COORDINATED WITH CITY OF PEMBOKE PINES
PROJECT MANAGER.
2 ALL WORK SHALL BE PERFORMED IN A CLEAN MANNER. ALL WORK
SHALL BE COORDINATED WITH OWNER'S PROJECT MANAGER TO
MINIMIZE ANY DISTURBANCE TO OTHER AREAS OF THE BUILDING
WHICH ARE TO REMAIN IN OPERATION.
3 THESE DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND
REPRESENT EXISTING CONDITIONS BASED ON AVAILABLE
DRAWINGS AND SITE OBSERVATIONS. CONTRACTOR IS
RESPONSIBLE FOR FIELD VERIFICATION OF ALL ACTUAL
CONDITIONS, FOR EXACT LOCATIONS AND SIZES OF PIPING,
CONDUIT, WIRES, EQUIPMENT, ETC.
4 EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE.
WORK DAMAGED BY THE CONTRACTOR SHALL BE REPAIRED TO
MATCH EXISTING WORK.
5 NEW JUNCTION BOX ON TOP OF THE DOOR FOR THE INSTALLATION
OF A NEW ACCES DOOR CONTROL SYSTEM. ELECTRICAL
CONTRACTOR SHALL COORINATE THE LOCATION WITH ACCES
CONTROL SYSTEM CONTRACTOR (TYPICAL).
ELECTRICAL
ROOM
116ELEV.
EQ.
CLASSROOM
BUILDING
C
EXISTING
PANEL LKC
LOCATION
J
CLASSROOM
CLASSROOM
SCIENCE
CLASSROOM
ENTRY
100 ENTRY
100 B
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
100A4321D5
LKC-39
BUILDING
C
CORRIDOR
200A
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
SCIENCE
CLASSROOM
ENTRY
200 ENTRY
200 B J
LKC-39
D4
APPROVED:
DRAWN:
SCALE :
OF:
PROJECT NO.:
DWG FILE:
DATE:
DATEREV No. DESCRIPTION
This drawing and the information and design application herein contained is property of INGEMEL S.A. The information contained herein may not be used or reproduced in any manner without written permission of INGEMEL S.A.
LEGENDS:
SHEET:
SHEET No.:
CONTENTS:
PROJECT ADDRESS:
PROJECT:
P.E. SEAL
TO THE BEST OF OUR KNOWLEDGE THE
PLANS AND SPECIFICATIONS COMPLY WITH
THE APPLICABLE MINIMUM BUILDING CODE
20871 Johnson Street, Suite 115 Phone: (954) 318-2264 Fax: (954) 450-7216
Pembroke Pines, Florida 33029
State of Florida CA No. 9113
PEMBROKE SHORES
CHARTER SCHOOL
ACCESS CONTROL
501 SW 172nd Avenue
Pembroke Pines, FL 33029
INDICATED 08-15-24
24-108
09-24-24 ISSUED FOR PERMIT-
ELECTRICAL PLAN
BLDG C
1ST & 2ND FLOOR
G. PACHECO 24-108E2
P. ARIAS
E -2
2 2
Pedro Arias, P.E.
Florida Registration. No. 63813
SCALE: 1/8" = 1'-0"
ELECTRICAL PLAN - BLDG C - 1ST FLOOR
SCALE: 1/8" = 1'-0"
ELECTRICAL PLAN - BLDG C - 2ND FLOOR
N.T.S.
KEY PLAN
BUILDING
B
BUILDING
A BUILDING
C
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN.
AutoCAD SHX Text
DN.
| 24-108 E-1-R0.pdf |
| Sheets and Views |
| E-1 |
| 24-108 E-2-R0.pdf |
| Sheets and Views |
| E-2 |
File details come from the government source that posted it. Updated .