UT FTFW OURA 11-1 Signed 100 AD Plans SS.PDF
PDF 13 MB Posted
- Attached to
- UT FTFW OURA 11(1), Auto Tour Route Federal contract opportunity
- Solicitation number
- 6982AF20B000030
About this file
This solicitation is for roadway rehabilitation and resurfacing work along segments of the Auto Tour Route within Ouray National Wildlife Refuge in Utah. The project includes rehabilitation and resurfacing of approximately 1.64 miles of the northwest segment and 1.51 miles of the northeast segment of the route, with 982 feet of roadway realignment on the northeast segment away from an embankment instability area. Additionally, 0.04 miles of an adjacent Fishing Access spur will be resurfaced. New gates, bollards and signs will also be installed. The purpose of the work is to improve access to portions of the refuge during high flow periods in the Green River by providing turnaround locations that allow segments of the route to remain open when flooded. The solicitation was issued by the Federal Highway Administration to rehabilitate and improve segments of the Auto Tour Route for continued safe access within Ouray National Wildlife Refuge.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| UT FTFW OURA 11(1) Auto Tour Route Amended Bid Opening Summary.pdf | ||
| UT FTFW OURA 11(1) Auto Tour Route Bid Opening Summary.pdf | ||
| Amendment A002.pdf | ||
| Amendment A001.pdf | ||
| IFB UT FTFW OURA 11-1 Auto Tour Route.pdf | ||
| UT FTFW OURA 11-1 Auto Tour Route - V1 PM tech memo rev. 07-10-19a.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SILT FENCE
6" min. trench
6" min.
18" min.
30" min.
24" min.
C157-50
NOTE:
4.
3.
2.
1.
6 ft. (max.)
fence support mesh = withoutPost spacing
10 ft. (max.)
fence support mesh =withPost spacing running around the ends.
fence up the slope to prevent water from
As the slope is constructed, curve the silt contours as closely as possible.
Install silt fence to follow the ground manufacturer's recommendations.
machine-sliced silt fence according to the slicing as approved by the CO. Install
Silt fence may be installed using machine
REVISED: 08/2014
A
M c p w w o r k in g c e n tr a l0 d C .d g n
U
S E
R
E1
ELEVATION
PLAN
POST AND GEOTEXTILE INSTALLATION DETAIL
SILT FENCE INSTALLATION AT TOE OF FILL
Flow Fi ll slo pe
Flow
T o e o f s lo p e
Flow
(undisturbed)
Existing ground
END POSTS DETAIL
PLAN
PLAN
END DETAIL
ELEVATION
Fi ll sl op e
Steel or wood post
Backfilled and compacted soil
Limits of clearing
Steel or wood post
Varies
Varies
See Note 3 for spacing
See Note 4
Fasten fabric to posts.
around each post one full turn.
Fold geotextile fabric
NO SCALE
PLAN
T o e o f s lo p e
Note 3See
Staple or tie
Top of posts tied together.
Posts driven tightly together.
Steel or wood posts
POSTS AT JOINTS
See End Posts Detail
End posts
Geotextile fabric
Staple or tie
SILT FENCE AS PERIMETER CONTROL
Fill
Existing ground
Sheet flow Silt fence
PLAN
SECTION A-A
A
A
Roadway
Edge of shoulder
Edge of shoulder
Toe of slope
Toe of slope
Posts Detail
See End
End posts
Silt fence
Fence support mesh (optional)
Section A fabric
Geotextile
Section B
Geotextile fabric
Geotextile
See Typical Section Sheet
STATE PROJECT
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
FEDERAL HIGHWAY ADMINISTRATION
U.S. DEPARTMENT OF TRANSPORTATION
REVISED:
DETAIL
U.S. CUSTOMARY DETAIL
U
S E
R
NUMBER
SHEET
UT
A
M c p w w o r k in g c e n tr a l0 d C .d g n
DETAIL APPROVED FOR USE
UT FTFW OURA 11(1)
AUTO TOUR ROUTE
NOTE:
12" min.
DETAIL APPROVED FOR USE 01/2011
FIBER ROLL
Maximum spacing (ft)
9" Ø Fiber Roll
Flow
12" min.
L im it
C le a r in g
S ta k e
S lo p e
INSTALLATION DETAIL
FIBER ROLL AS PERIMETER CONTROL
uphill side of fiber roll
Place excavated material on
A
M c p w w o r k in g c e n tr a l0 d C .d g n
U
S E
R
AT CULVERT OUTLET
FIBER ROLL
flared end section
Culvert inlet with
AT CULVERT INLET
FIBER ROLL
flared end section
Culvert outlet with Flow
D ire c tio n o f ru n o ff
Flow
FIBER ROLL LAPPING DETAIL
Stagger joints (typ.)
FIBER ROLL JOINT DETAIL
FIBER ROLL SLOPE LAYOUT
spacing table See Fiber Roll along contours
Install fiber rollsWood stakes
Fiber Roll
Slope
Fiber Roll
Pay Limits
Pay Limits overlap 12" (min.)
Fill slope
C157-55 side of fiber roll material on uphill
Place excavated
Flow Flow
54" or larger
Culvert Size
24" or smaller
30" to 48"
9" Ø Fiber Roll length (ft)
FIBER ROLLS AT CULVERTS*
needed due to project-specific conditions.
top of the culvert inlet only. Adjust length as
*Approximate length shown for rolls across the
See note 6 control runoff culvert as needed to
Install fiber rolls below
6.
5.
4.
3.
2.
1.
disturbance.
and all water entering the culvert is crossing the disturbance is on both the road and around the culvert
Place fiber rolls all the way around the inlet when the under it.
water is forced to flow through fiber roll rather than against upstream side of fiber roll to ensure storm with trench bottom and sides. Tamp soil backfill to the contour. Place fiber rolls in continuous contact
For fiber rolls on bare soil, construct trenches parallel
Expose stakes 2" above top of fiber roll.
Drive stakes into undisturbed soil at least 12" deep.
from each end.
2' o.c. max. culverts. Stake fiber rolls 6-inches stakes. Space stakes 4' o.c. max. on slopes and
Stake fiber rolls in place with 1" x 1" or 1" Ø wood vary more than 5% from level.
section of fiber roll, do not allow the fiber roll to
Install fiber rolls along slope contours. For any 20' to installation.
Repair all rills or gullies and properly compact prior
A A
Trench 2" min.
See no te 3
See no te 3
2" min.
Trench table for length requirements
See Fiber Rolls at Culverts culvert inlet
Install fiber rolls around table for length requirements
See Fiber Rolls at Culverts culvert outlet
Install fiber rolls around
Flow
Fiber roll roll 2" min.
Trench fiber
SECTION A-A
REVISED: 12/2017
E2
Flow
NO SCALE
1V:4H or flatter
Slope Gradient
1V:2H or steeper
STAKE DETAIL
uphill side of fiber roll
Place excavated material on
Fill or cut slope
FIBER ROLL SPACING TABLE*
project-specific conditions.
*Approximate spacing shown. Adjust spacing as needed due to
Between 1V:4H and 1V:3H
Between 1V:3H and 1V:2H
STATE PROJECT
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
FEDERAL HIGHWAY ADMINISTRATION
U.S. DEPARTMENT OF TRANSPORTATION
U.S. CUSTOMARY DETAIL
U
S E
R
NUMBER
SHEET
UT
A
M c p w w o r k in g c e n tr a l0 d C .d g n
DETAIL APPROVED FOR USE 12/2012
SUBEXCAVATION
NO SCALE C204-51
See bench detail than 2 ft Bench if greater Varies (2 ft typ.)
max.
2 ft
1 ft min.
6.
5.
4.
3.
2.
1.
NOTE:
the CO.
not construct slopes steeper than 1:2 unless approved by slope adjustments to match the subgrade hinge point. Do
At daylight locations, match the existing fill slope or make roadway cross slope when steeper than 2%.
toward the daylight for drainage, or match the existing subgrade hinge point. Slope the excavation bottom 2%
Daylight to drain when the excavation is within 4 ft of the every 2 ft of subexcavation depth.
in bottom layers. Provide a 1 ft min. bench width for
Widen top of subexcavation area to allow for bench width
Do not place backfill material within the structural section.
Minimum subexcavation dimensions are 6 ft wide x 6 ft long.
unless otherwise specified.
Replace unsuitable material according to Subsection 204.07
REVISED: 08/2014
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
FEDERAL HIGHWAY ADMINISTRATION
U.S. DEPARTMENT OF TRANSPORTATION
U.S. CUSTOMARY DETAIL
DETAIL
F1 structural section
See typical sections for
Finished grade according to Section 204
Backfill with material
TYPICAL SECTION
SUBEXCAVATION
Geotextile
BENCH DETAIL
Total subexcavation width
Width of need according to Section 204
Backfill with material structural section
See typical sections for
Finished grade
STATE PROJECT
U
S E
R
NUMBER
SHEET
UT
A
M c p w w o r k in g c e n tr a l0 d C .d g n