This is a product specification document for the Sure-Lites SLX Series LED exit lighting units, designed for commercial, institutional, and multi-housing applications. The SLX Series features field-selectable red and green sign capability, dual voltage input of 120/277 VAC at 60Hz, and optional two-circuit (2C) operation. Units are constructed with 20-gauge steel housing and universal mounting patterns that support ceiling or end mounting with optional canopy and backplate configurations. The exit lamps utilize energy-efficient LED technology consuming less than one watt on average, with red and green lenses made from impact-resistant polycarbonate. The self-powered option includes a sealed nickel cadmium battery with a 24-hour maximum recharge time and patented EZ Key external battery disconnect feature. All units are UL 924 listed, comply with UL Damp Location standards, Life Safety NFPA 101, and NEC/OSHA requirements, with NOM certification available.

The SLX Series exits are available in multiple configurations designated as either AC Only (SLX6) or Self Powered (SLX7), with optional self-diagnostics capability (SD) featuring automatic testing per UL924 and NFPA 101 standards and random 90-minute battery simulation tests. Units operate at minimal power consumption ranging from 0.98 to 1.12 watts at 120V and 1.03 to 1.12 watts at 277V, depending on color and voltage configuration. The product line includes customizable signage options beyond the standard EXIT sign, such as "AREA OF RESCUE," "SALIDA," "STAIRS," and directional indicators, with optional accessories including wall-mount wire guards, polycarbonate vandal shields, and pendant kits. Sure-Lites products are backed by a one-year warranty against defects in material and workmanship, while batteries carry a fifteen-year pro-rata warranty. The manufacturer is Cooper Lighting Solutions located in Peachtree City, Georgia.

View the file

Other files

File Type Posted
230529-RIB-Hangers and Supports for HVAC Piping and Equipment-12-24-2025.pdf PDF
221005-RIB-Plumbing Piping-12-24-2025.pdf PDF
235216-RIB-Condensing Boilers-12-24-2025.pdf PDF
260519-RIB-Low-Voltage Electrical Power Conductors and Cables-12-24-2025.pdf PDF
230719-RIB-HVAC Piping Insulation-12-24-2025.pdf PDF
221006-RIB-Plumbing Piping Specialties-12-24-2025.pdf PDF
265140-LUT-Luminaires-12-24-2025.pdf PDF
235100-RIB-Breechings, Chimneys, and Stacks-12-24-2025.pdf PDF
230923 Alerton Direct Digital Control System for HVAC.pdf PDF
TYPE P2 Metalux-Cruze-Linear-Bay-spec-sheet.pdf PDF
Bid Questions - BCE Response - 05012026.pdf PDF
230553-RIB-Identification for HVAC Piping and Equipment-12-24-2025.pdf PDF
265600-RIB-Exterior Lighting-12-24-2025.pdf PDF
230593-RIB-Testing, Adjusting, and Balancing for HVAC-12-24-2025.pdf PDF
260583-RIB-Wiring Connections-12-24-2025.pdf PDF
260553-RIB-Identification for Electrical Systems-12-24-2025.pdf PDF
230513-RIB-Common Motor Requirements for HVAC Equipment-12-24-2025.pdf PDF
220553-RIB-Identification for Plumbing Piping and Equipment-12-24-2025.pdf PDF
233100-RIB-HVAC Ducts and Casings-12-24-2025.pdf PDF
233423-RIB-HVAC Power Ventilators-12-24-2025.pdf PDF
265100-RIB-Interior Lighting-12-24-2025.pdf PDF
237413-RIB-Packaged Outdoor Central-Station Air-Handling Units-12-24-2025.pdf PDF
TYPE EMX CMB-ISOLITE-Specification.pdf PDF
230523-RIB-General-Duty Valves for HVAC Piping-12-24-2025.pdf PDF
25388-CBI 100% CD w Add1.pdf PDF
232113-RIB-Hydronic Piping-12-24-2025.pdf PDF
TYPE S1 iO-CoviO-Spec-Sheet.pdf PDF
232123-RIB-Hydronic Pumps-12-24-2025.pdf PDF
262726-RIB-Wiring Devices-12-24-2025.pdf PDF
260923-RIB-Lighting Control Devices-12-24-2025.pdf PDF
TYPE P1 Corelite-Iridium-i3-Suspended-specification-sheet.pdf PDF
238126.13-RIB-Small-Capacity Split-System Air Conditioners-12-24-2025.pdf PDF
220529-RIB-Hangers and Supports for Plumbing Piping and Equipment-12-24-2025.pdf PDF
231123-RIB-Facility Natural-Gas Piping-12-24-2025.pdf PDF
232114-RIB-Hydronic Specialties-12-24-2025.pdf PDF
230913-RIB-Instrumentation and Control Devices for HVAC-12-24-2025.pdf PDF
260505-RIB-Selective Demolition for Electrical-12-24-2025.pdf PDF
CBI GJ Project Manual_VSS_R2.pdf PDF
230800-RIB-Commissioning of HVAC-12-24-2025.pdf PDF
TYPE D3 PrentaLux-CYL6-6-Sustainable-LED-Cylinder-Luminaire-Spec-Sheet.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sure-Lites SLX Series LED exit is a steel unit suitable for commercial, institutional, and multi-housing applications. With the new advanced standard features and industry leading innovations, they are now the most universal, energy friendly, easiest to stock and install, and safest Exits in their class.

SPECIFICATION FEATURES

Electrical

- General Features

- Field selected red and green sign capability standard on all units (units shipped red, field convert to green with supplied parts)

- Dual Voltage Input 120/277 VAC,60Hz

- AC Only

- Optional 2C (Two circuit, FTBR) available in 120/277 VAC in standard and emergency operation

- Self Powered

- Sure-Lites EZ Key patented external battery disconnect feature

– prevents unnecessary battery drainage, saves on installation time

- Solid-state Voltage Limited Charger

- Brownout Circuit

- Low-Voltage Disconnect

- Test Switch/Power Indicator Light

- Standard 24 hour recharge time (max)

- Eagle Eye™ Self-Diagnostic Standard

Housing Construction

- 20-gauge steel housing

- Universal pattern knockouts on rear for direct mounting to junction box

- Knockouts for chevron directional indicators

- Canopy allows ceiling or end Mounting

- Universal styles offer complete installation flexibility with canopy, backplate, and two stencil faces

Battery (Self Powered Only)

- Sealed Nickel Cadmium

- Maintenance-Free, Long-Life

- Full Recharge Time, 24 hrs. (max)

Code Compliance

- UL 924 Listed

- UL Damp Location (0-40C

- Life Safety NFPA 101

- NEC/OSHA

- Most State and Local Codes

- NOM Certified

- UL Listed for 2C (FTBR)

Warranty

- Exit – 5 year

- Battery: 5-Year pro-rata

Lamp Data

- AC LED: Red and green LED lamps provide uniform diffused illumination

- DC: Red and green LED DC lamps (Brighter in emergency mode)

SLX SERIES

DESCRIPTION

4 5/8" [117mm]

7 1/2" [191mm]

12 1/4" [311mm]

6 7/8" [175mm]

6 7/8" [175mm]

1 1/4" [32mm]

2 1/4" [57mm]

STEEL EXIT

SURFACE MOUNT

LED LAMPS

EXIT LIGHTING

E N E R G Y D A T A Maximum power consumption under all charge conditions:

AC Only, 120V - Red

Amps: 0.07

Watts: 0.98

Power Factor: 0.12

AC Only, 120V - Green

Amps: 0.07

Watts: 1.02

Power Factor: 0.13

AC Only, 277V - Red

Amps: 0.07

Watts: 1.04

Power Factor: 0.06

AC Only, 277V - Green

Amps: 0.07

Watts: 1.12

Power Factor: 0.06

Self Powered, 120V - Red

Amps: 0.07

Watts: 0.98

Power Factor: 0.12

Self Powered, 120V - Green

Amps: 0.07

Watts: 1.00

Power Factor: 0.13

Self Powered, 277V - Red

Amps: 0.07

Watts: 1.03

Power Factor: 0.06

Self Powered, 277V - Green

Amps: 0.07

Watts: 1.09

Power Factor: 0.05

TD505021EN

2021-7-19

Catalog # Type

Date

Project

Comments

Prepared by

AP SERIES EXITS WITH SQUARE HEADS COMBO

ORDERING INFORMATION

TECHNICAL DATA

Lamps SLX Series Exits use energy efficient, long life LED’s to provide uniform diffuse illumination of the exit face. These red and green LEDs require no maintenance and consume less than one watt, on average.

Housing Construction Exit housing is constructed of durable 20-gauge cold rolled steel with corrosion resistant polyester powder coat paint finish. All exits can be mounted and wired through knockouts located on the top and side. Surface mount back panel has knockouts for direct mounting to junction box. The mounting canopy is made of impact resistant thermoplastic with complementary finish. Stencil face exits are supplied with knockout chevron directional indicators for easy conversion to directional exits. Exit stencil and backplate install in channels in the exit housing to eliminate light leaks.

Lens Lenses for the SLX Series Exits are made from durable, impact resistant polycarbonate. All exit faces are designed with full 3/4” stroke snap-out or snap-in chevron directional indicators to insure maximum visibility and compliance with the latest codes. Units come with red lenses installed and green lenses included for field selectable red or green signs.

Sure-Lites EZ Key External Battery Disconnect (Self Powered Only) Patented technology that allows installers to externally control the battery connection. Better than line latching, allows installers to choose when the battery is connected so that it stays fresh longer. Allows battery to be disconnected after installation but before building is occupied, enabling emergency circuit to be shut down for power savings.

Brownout Circuit (Self Powered Only) The brownout circuit on Sure-Lites’ exits monitors the flow of AC current to the exit and activates the emergency lighting system when a predetermined reduction of AC power occurs.

This dip in voltage will cause most ballasted fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred.

Solid-State Transfer (Self Powered Only) The SLX Series Exit incorporates solid-state switching which eliminates corroded and pitted contacts or mechanical failures associated with relays. The switching circuit is designed to detect a loss of AC voltage and automatically energizes the lamps using DC power. Upon restoration of AC power, the DC power will be disconnected and the charger will automatically recharge the battery.

Low Voltage Disconnect (Self Powered Only) When the battery’s terminal voltage falls, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge.

Test Switch/Power Indicator Light (Self Powered Only) A test switch located on the side of the exit permits the activation of the emergency circuit for a complete operational systems check. The Power Indicator Light provides visual assurance that the AC power is on.

Sealed Nickel Cadmium Battery (Self Powered Only) Sure-Lites sealed nickel cadmium batteries are maintenance-free with a life expectancy of 15 years. The sealed rechargeable nickel cadmium battery offers high discharge rates and stable performance over a wide range of temperatures, from 0-40° C. The specially designed re-sealable vent automatically controls cell pressure, assuring safety and reliability. This battery is best suited for harsh ambient temperatures because the electrolyte is not active in the electrochemical process.

“2C” (AC Only) he “2C” Option enables the Exits to operate per the requirements of UL 924 when connected simultaneously to both normal and emergency power circuits (two circuit operation–UL Category FTBR–Emergency Lighting and Power Equipment). The “2C” Option alters the standard Exit such that it complies with and is UL Listed under the FTBR Category. This option should only be used for exits which are intended to be connected simultaneously to normal and emergency power circuits, but cannot support two hot inputs. Only one of the normal or emergency circuits can be powered.

If both are powered simultaneously, it will make the Exit inoperable. Both circuits have universal 120/277 VAC standard.

Eagle Eye™ Self Diagnostics Standard on SLX7 The self-diagnostic unit will automatically perform all tests required by UL924, and NFPA

101. The system indicates the status of the exit at all times using the LED indicator near the test switch on the side of the unit. A 90 minute battery power (emergency mode) simulation test will occur randomly once every 12 months.

A 30 second battery power simulation test will occur every 30 days.

Warranty All Sure-Lites’ products are backed by a firm one-year warranty against defects in material and workmanship. Maintenance-free, long-life, sealed nickel cadmium batteries carry a fifteenyear pro-rata warranty.

TD505021EN

2021-7-19

Sample Number: SLX7, SLX7SD90, SLX6SR2, SLX7SD23050

Family

SLX Steel Exit, LED=

Series

6 AC Only= 7 Self Powered=

Housing Finish

Blank White=

BK Black=

S Open Face for Signage (single face, White housing only)

Blank Single and Double

Face Options Features

2C Two Circuit Option (SLX6 only)

SD Self Diagnostics Standard (SLX7 only)

Blank No additional options

Signage Options (Color)

Blank EXIT sign=

R Red letter, Red LED

G Green letter, Green LED

B Blue letter, White LED

Signage Options (Common Signs)

Blank EXIT sign=

1 “AREA OF RESCUE”=

2 “SALIDA”=

3 “STAIRS”=

4 “AREA OF REFUGE”=

5 “IN USE”=

6 “NOT AN EXIT”=

7 (WHEEL CHAIR SYMBOL)=

8 “X-RAY ON”=

9 “LASER IN USE”=

10 “DO NOT ENTER”=

[Options for non-EXIT signs]

Protection Devices

WG10 Wall mount wire guard

VS1 Polycarbonate Vandal Shield

VS1WP Polycarbonate Vandal Shield, Weather Proof

WGS11 Ceiling or End mount wire guard

Pendant Kit

PK18PKWH 18˝ Pendant Kit, White=

PK18PKBK 18˝ Pendant Kit, Black=

PK18PKHTWH 18˝ Hang True Pendant Kit, White

PK18PKHTBK 18˝ Hang True Pendant Kit, Black

Available Accessories (Order Separately)

1 Consult factory for additional custom signage options.

2 Blue Letters, White LED does not have the “SD” option.

3 Units ordered with “Salida” signage (e.g., SLX6SR2) will use a steel stencil that outlines the word “Salida”, while all other signage options will be open-face.

Notes:

SD90 Self Diagnostics with Fire Alarm Interface Capability (SLX7 Only)

Specifications and dimensions subject to change without notice.

Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com

Anna Text Box

SLX

Anna Text Box

Anna Text Box S

Anna Text Box

SD

Anna Text Box R

Anna Text Box

Text Field 7: SLX7-S-SD-R5
Text Field 8:
Text Field 9:
Text Field 10:
Text Field 11: IU
Text Field 12:

File details come from the government source that posted it. Updated .