TL 6 - 2nd Floor Plan.pdf
PDF 322 KB Posted
- Attached to
- RFP for Theatrical Systems & Controls
- Solicitation number
- RFP-CHAR-250000000116-3
- Issued by
- Cass County, Michigan
About this file
This document appears to be a set of installation notes and requirements for a lighting upgrade project at the Charlevoix Middle/High School Auditorium, located in Charlevoix, Michigan. The project involves installing new CAT6 cables, LED lamps, lighting tracks and fixtures, wall dimmers, fluorescent fixture LED retrofit kits, LED "Jelly Jar" and "House/Work" light fixtures, a new DRd Rack, and associated cabling and conduit work. The installation notes detail the specific quantities and locations of the new equipment to be installed, as well as instructions for interconnecting the new equipment with the existing dimmer racks and LCR1 equipment rack.
The document also includes separate installation notes for the Technology Lighting Vendor (TLV), which entail installing new Ethernet connectors, Unison stations, and performing power package upgrades to existing sensor racks. While specific pricing terms, funding sources, and award dates are not provided, the document appears to be part of a state or local government contract opportunity related to the auditorium lighting upgrades at the Charlevoix Middle/High School.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CL
UNLESS OTHERWISE SPECIFIED ALL
DIMENSIONS ARE IN INCHES.
REPRESENTATIVE:
APPLICATIONS ENGINEER:
DATE
PROJECT MANAGER:
ORIGINAL FILE:
BY REV.
LOCATION:
DRAWING TITLE:
CONTRACT WITH:
JOB:
JOB NUMBER:
DRAWING:
CHARLEVOIX HIGH SCHOOL THEATRE
Detroit, MI 48211
Fantaseeintegration.com
6235 Concord Ave., Tel 1-734-699-7200
CHARLEVOIX, MICHIGAN
CHARLEVOIX HIGH SCHOOL
Jon Weaver
DATEBY REV.
05-05-24G.O.
GROUND PLAN VIEW - UPPER
SCALE:
16"= 1'0" rblain Rectangle rblain Rectangle rblain Rectangle rblain Rectangle
AutoCAD SHX Text
BOX BOOM
AutoCAD SHX Text
BOX BOOM
AutoCAD SHX Text
LOADING BRIDGE
AutoCAD SHX Text +360"
AutoCAD SHX Text
FANTASEE INTEGRATION
rblain Rectangle rblain Snapshot rblain Arrow rblain Polygon rblain Text Box rblain Arrow rblain Arrow rblain Arrow rblain Arrow rblain Arrow rblain Ellipse rblain Ellipse rblain Ellipse rblain Ellipse rblain Ellipse rblain Ellipse rblain Ellipse rblain Ellipse rblain Arrow rblain Arrow rblain Arrow rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Arrow rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Text Box
EC INSTALLATION NOTES:
1) Install 3 new CAT6 cables running from this location to Dimmer Room Rack LCR1.
2) Install 3 new CAT6 cables running from this location to Dimmer Room Rack LCR1
3) Install new CAT6 cable running from this location to Dimmer Room Rack LCR1.
4) Install 8 LED Lamps (to be supplied by the TLV).
5) Install 2 new lighting tracks and 8 new track fixtures (to be supplied by the TLV).
6) Install 2 wall dimmers (to be supplied by the TLV).
7) Install new Fluorescent fixture LED retrofit Kit (to be supplied by the TLV).
8) Install 12 ne LED blue "Jelly Jars" (to be supplied by the TLV).
9) Install the following new LED "House" & "Work" Light fixtures and lamps (to be supplied by the TLV):
25 Clear LED Jelly Jars 23 LED Pendant Cylinders 11 LED Wall Mounted Cylinders 16 LED Ceiling Mounted (500w) 30 "A" Type LED Lamps
13) Install new "DRd" Rack (matching existing circuit numbers).
16) Install all required cable and conduit for interconnection between existing dimmer racks, DRd rack, and LCR1 equipment rack as per riser drawing.
17) Install back box (to be supplied by the TLV) and run CAT6 cable from this location to Dimmer Room Rack LCR1.
rblain Text Box
TLV INSTALLATION NOTES:
1) Install 3 new Ethernet connectors using newly installed Cat6 cables.
2) Install 2 new Ethernet connectors using newly installed Cat6 cables.
rblain Text Box
10) Install new 1-button Unison Station. Reuse existing Unison wires.
11) Install new 2-button Unison Station. Reuse existing Unison wires.
rblain Text Box
12) Install new 5-button Unison Station. Reuse existing Unison wires.
13) Load existing D20 modules into new "DRd" Rack.
rblain Text Box
14) Install and test rack LCR1 components.
15) Perform Power Package Upgrades for 3 existing SR48 Sensor Racks rblain Text Box
17) Install gateway as per Riser.
rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Polygon rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Rectangle rblain Text Box rblain Text Box
DRAWING TITLE:
2ND FLOOR PLAN
rblain Text Box
DRAWN BY:
R. BLAIN
rblain Text Box
DRAWING #
TL 6
rblain Text Box
SCALE:
NTS
rblain Text Box
CHARLEVOIX MIDDLE/HIGH SCHOOL AUDITORIUM LIGHT UPGRADES 2024
rblain Text Box
RPB
rblain Text Box 5/23/24 rblain Text Box
CHARLEVOIX PUBLIC SCHOOLS
| Sheets and Views |
| CHARLEVOIXHSTHEATRE-GP UPPER |
File details come from the government source that posted it. Updated .