TL 1 - Symbols & Notes.pdf
PDF 1 MB Posted
- Attached to
- RFP for Theatrical Systems & Controls
- Solicitation number
- RFP-CHAR-250000000116-3
- Issued by
- Cass County, Michigan
About this file
This document appears to be a technical drawing and legend for the Charlevoix Middle/High School Auditorium Lighting Upgrades 2024 project. The drawing provides specifications for conduit, wiring, and mounting details for the electrical work required. The project is being managed by Fantasee Integration for the Charlevoix Public Schools. The drawing includes general notes for the electrical contractor, a control wiring legend, and specific details on wire types and identification. While the document does not provide a full scope of work or project details, it indicates the planned upgrades to the school auditorium's lighting systems.
The document does not contain information on pricing, set-asides, incumbents, funding sources, or other contractual terms. It appears to be a technical drawing provided as part of the overall project specifications and requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UNLESS OTHERWISE SPECIFIED ALL
DIMENSIONS ARE IN INCHES.
REPRESENTATIVE:
APPLICATIONS ENGINEER:
DATE
PROJECT MANAGER:
ORIGINAL FILE:
BY REV.
LOCATION:
DRAWING TITLE:
CONTRACT WITH:
JOB:
JOB NUMBER:
Detroit, MI 48211
Fantaseeintegration.com
6235 Concord Ave., Tel 1-734-699-7200
CHARLEVOIX, MICHIGAN
CHARLEVOIX HIGH SCHOOL
Jon Weaver
DATEBY REV.
DRAWING:
SCALE:
AutoCAD SHX Text
FANTASEE INTEGRATION
rblain Rectangle rblain Text Box
STATION TYPE
rblain Text Box
STATION_ID
rblain Text Box
CLR
rblain Text Box
MTG
rblain Text Box
LOCATION
rblain Text Box rblain Text Box
COLOR DETAIL
rblain Text Box
CRM
rblain Text Box
IVR
rblain Text Box
GRY
rblain Text Box
BLK
rblain Text Box
WHT
rblain Text Box
CC
rblain Text Box
CLR
rblain Text Box
KEY
rblain Text Box
CREAM (RAL 9001)
rblain Text Box
IVORY (RAL 1015)
rblain Text Box
GRAY (RAL 7001)
rblain Text Box
BLACK (RAL 9004)
rblain Text Box
SIGNAL WHITE (RAL 9003)
rblain Text Box
CUSTOM
rblain Text Box
UNKNOWN
rblain Text Box
DESCRIPTION
rblain Line rblain Line rblain Text Box
MOUNTING DETAIL
rblain Text Box S rblain Text Box
SL
rblain Text Box
SSL
rblain Text Box F rblain Text Box
FL
rblain Text Box
FSL
rblain Text Box U rblain Text Box
KEY
rblain Text Box
SURFACE
rblain Text Box
SURFACE WITH LOCKING COVER
rblain Text Box
SURFACE WITH SLIDING LOCKING COVER
rblain Text Box
FLUSH
rblain Text Box
FLUSH WITH LOCKING COVER
rblain Text Box
FLUSH WITH SLIDING LOCKING COVER
rblain Text Box
U-BOLT
rblain Text Box
DESCRIPTION
rblain Line rblain Line rblain Text Box
OU
rblain Text Box
OFFSET U-BOLT
rblain Text Box
MTG
rblain Text Box
UNKNOWN
rblain Text Box
STATION COLOR AND MOUNTING KEY
rblain Rectangle rblain Rectangle rblain Rectangle rblain Rectangle rblain Rectangle rblain Line rblain Line rblain Line rblain Line rblain Line rblain Line rblain Line rblain Line rblain Line rblain Line rblain Image rblain Rectangle rblain Image rblain Rectangle rblain Text Box
CHARLEVOIX MIDDLE/HIGH SCHOOL AUDITORIUM LIGHTING UPGRADES 2024
PROJECT NO: TBD BID# TBD
rblain Image rblain Rectangle rblain Text Box
CONDUIT GENERAL NOTES FOR ELECTRICAL CONTRACTOR
- EC to provide and install all conduit, backboxes, gutter boxes, terminal cans, raceways, cable trays and access panels unless otherwise noted.
- EC to install pull lines in all conduits.
- EC shall not substitute conduit type without written permission from the consultant.
- Conduit runs are drawn for illustration only. Actual conduit paths & interim boxes to be determined by the EC.
- EC may increase the size of junction boxes, gutters & conduit as needed in the event that a conflict exists.
- EC to provide and install all high voltage (120V - 240V) cable and fixtures unless otherwise notes.
- Install applicable size pull boxes after 270 deg. of bend or if conduit run is more than 100'.
- Label all conduit for destinations such as box numbers and/or room locations.
- Deburr all rough edges to prevent cable abrasion.
- Ensure all conduits are free from debris & water.
- Ensure all in ground pull boxes and vaults are weather proof & free of debris & water.
- Ensure conduit is electrically isolated from all equipment racks & enclosures rblain Text Box
CONTROL WIRING LEGEND
rblain Text Box
SYMBOL
rblain Text Box
WIRE TYPE(S)
rblain Text Box
SIGNAL
rblain PolyLine rblain Line rblain Line rblain Line rblain Line rblain Line rblain Text Box
* = WIRE IDENTIFICATION NUMBER (NOT QUANTITY)
rblain PolyLine rblain Rectangle rblain Text Box
(1) BELDEN #2412
rblain Text Box ETCNet
(CAT6)
rblain Text Box N* rblain Line rblain Line rblain Line rblain Line rblain Polygon rblain Rectangle rblain Text Box
(1) BELDEN #8471
(1) #14 AWG. STRANED GND WIRE
rblain Text Box
UNISON
rblain Text Box U* rblain Line rblain Line rblain Line rblain Line rblain Polygon rblain Image rblain Rectangle rblain Text Box
DRAWING TITLE:
SYMBOLS & NOTES
rblain Text Box
DRAWN BY:
R. BLAIN
rblain Text Box
DRAWING #
TL 1
rblain Text Box
SCALE:
NTS
rblain Text Box
CHARLEVOIX MIDDLE/HIGH SCHOOL AUDITORIUM LIGHT UPGRADES 2024
rblain Text Box
RPB
rblain Text Box 5/23/24 rblain Text Box
CHARLEVOIX PUBLIC SCHOOLS
| Sheets and Views |
| CHARLEVOIXHSTHEATRE-BLANK |
File details come from the government source that posted it. Updated .