This is a Diffused Aeration System Modeling Program document prepared by Tideflex Technologies for Hydro Controls, detailing the design specifications for coarse bubble mixing and oxygen aeration systems for Sludge Storage Tanks No. 2 and No. 3 at Cincinnati/Northern Kentucky International Airport's Wastewater Treatment Plant. The modeling document, dated June 27, 2025 (Revision 1), provides comprehensive engineering calculations and design parameters for upgrading from fine bubble to coarse bubble diffuser systems. The project involves two circular tanks with 113-foot diameters and 14.95-foot depths, each with a liquid volume capacity of 1,121,475 gallons. The design specifies TFA-3.00 coarse bubble diffusers with a total required airflow of 7,600 cubic feet per minute distributed across two blowers operating at 3,800 CFM each. The system is engineered to deliver an Actual Oxygen Requirement (AOR) of 5,664 pounds per day based on an aerobic digestion process for sludge with 4.0 percent solids concentration and a recommended oxygen uptake rate of 12.62 milligrams per liter per hour.

The modeling calculations account for site-specific conditions including the facility's elevation of 840 feet above mean sea level, wastewater temperature of 68 degrees Fahrenheit, and atmospheric pressure of 14.26 psia. The coarse bubble system design specifies blower requirements of 209 brake horsepower per blower with discharge pressures of 7.05 pounds per square inch gauge and adjusted airflow of 4,261 actual cubic feet per minute per blower at site conditions. The design incorporates Type 304 stainless steel distribution piping with 14-inch nominal diameter drop pipes, 8-inch and 6-inch manifold sections, and 0.5-inch diameter diffuser orifices. Headloss calculations throughout the system total 195.87 inches, including hydrostatic pressure of 176.40 inches, drop pipe losses of 1.21 inches, and combined diffuser body and orifice losses of 9.0 inches. The oxygen transfer efficiency is projected at 24.8 percent of the Standard Oxygen Transfer Rate under the specific process conditions, with velocity gradient mixing design calculations confirming adequate mixing for the 12.13 percent efficiency target in the coarse bubble system.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Company/Agency Name:

Facility Name:

Location:

Contact:

Email:

Consulting Firm:

Location:

Contact:

Email:

Tideflex Representative:

@ Engineering / Design Location

Contact:

Email:

Tideflex Representative:

@ Equipment Installation Location

Contact:

Email:

Revision Date:

Revision Description:

Diffused Aeration System Modeling Program

Hydro Controls Milford, OH

Airport WWTF Operations

Cincinnati / Northern Kentucky International Airport Sludge Storage Tank No.2 & No.3 - Coarse Bubble Mixing & O2 System

Wastewater Treatment Plant Cincinnati / Northern Kentucky International Airport

DESIGN FOR MIXING & O2

PHONE (412) 279-0044

750 Holiday Drive, Suite 400, Pittsburgh, PA 15220

Revision 1 - Initial Design

Adam McCarthy

6/27/2025 9:28 amccarthy@hydrocontrols.net

Hydro Controls Milford, OH Adam McCarthy amccarthy@hydrocontrols.net

Model Version:02-01-2025 I:\Engineering\TAD (Air Diffusers)\Projects\USA\Cincinnati (CVG) Airport, KY\2025 Sludge Tanks\Model\Tideflex Aeration Model_Rev1.xlsm

0.0 gpd 0.00 m3/day

0.0 mg/l

0.0 mg/l

0.0 mg/l

0.0 mg/l

0.0 mg/l

0.0 mg/l

1.10 lbs O2/lb BOD 0.499 kg O2/kg BOD

4.30 lbs O2/lb BOD 1.950 kg O2/kg BOD

MLSS Concentration for Activated Sludge Process 0 mg/l 0.20

0.0 lbs/day 0.0 kg/day

12.62 mg/l/hr 12.00 mg/l/hr (Recommended for this Process Fluid) Process Fluid Solids Concentration 4.00 % Solids

Alpha Factor 0.30 % Transfer Adjustment @ Solids Concentration

0.25 ft. 0.1 m Diffuser Depth (Dp) 14.70 ft. 4.5 m

Site Elevation above Mean Sea Level 840.0 ft. 256.0 m Barometric Pressure at Site (Pa) 29.04 in Hg 14.26 psia 98.336 kPa

Barometric Pressure at Mean Sea Level (Pmsl) 29.92 in Hg 14.70 psia 101.320 kPa Process Water Salinity 0.00 ppt

Surface Oxygen Saturation at 20 C (Cs) 9.09 mg/l Surface Oxygen Saturation at Temp (Cst) 9.09 mg/l Residual Dissolved Oxygen Level (DO) 1.00 mg/l

Waste Water Temperature (T) 68 F 20.0 C Fine Bubble Coarse Bubble

Model Number TFX-STYLE-1 TFA-3.00 Alpha Factor 0.45 Beta Factor 0.950 Beta Factor 0.950

Theta Factor 1.024 Theta Factor 1.024 Depth Correction Factor (f) 0.40 0.25

Corrected Saturation at Std. for Depth (Css) 10.67 mg/l 10.08 mg/l Corrected Saturation at Temp. for Depth (Csw) 10.40 mg/l 9.81 mg/l

Inlet Blower Air Temperature at the Site 100 F 37.7 C Saturated Vapor Pressure at Site Temperature 0.9503 psia 6.552 kPa

Relative Humidity at the Site 50% Applied Blower Efficiency 55%

Pressure at Standard Conditions 14.70 psia 101.354 kPa Temperature at Standard Conditions 68 F 20.0 C

Saturated Vapor Pressure at Standard Temperature 0.3391 psia 2.338 kPa Relative Humidity at Standard Conditions 36%

Density of Air at Standard Conditions 0.075 lbs/ft^3 1.201 kg/m3 Density of Air Correction factor 0.8917

Corrected Density of Air at Site Elevation & Temp 0.0669 lbs/ft^3 1.071 kg/m3

Process Design Values

Oxygen Transfer Efficiency Values

Blower Parameters

Food to BioMass ratio F/M

Diffuser Variables

Oxygen Supply Rate provided at design airflow rate

Diffuser distance from base of Tank

Lbs of Oxygen required per lb. Of BOD removed Lbs of Oxygen Required per lb. Of NH3 removed

Pre-Determined AOR Value to be Applied

Design BOD influent concentration

Influent / Effluent Concentrations

Design NH4 influent concentration Design NH4 effluent concentration

Design BOD effluent concentration

Cincinnati / Northern Kentucky International Airport Sludge Storage Tank No.2 & No.3 - Coarse Bubble Mixing & O2 System

Input Data & Design Parameters for Biological / Chemical Process Systems

Design COD effluent concentration

DESIGN FOR MIXING & O2

Design Plant Flowrate Design COD influent concentration

Disclaimer: The calculations, projections and values produced within this model are based upon the applied site specific values as shown on the Input Data page and any other related pages. These site specific values may have been provided by the facility owner, consulting engineer or derived from industry standards. Any variance in these values will effect the projections produced within this model. This model is intended to provide design guidance related to the operation of the Tideflex System and/or Tideflex components. Air Diffuser data applied within the model is derived from certified performance curves for headloss and oxygen transfer capacity under standard conditions for ASCE testing. All conversions applied within the model for determining the effectiveness in specific process fluids, as compared to clean water testing, are intended as a projection of the actual conditions expected. Tideflex Technologies shall not be responsible for the accuracy of these projected conditions.

6/27/2025 Tideflex Engineered Systems

A Division of Red Valve Company, Inc. Page 2 of 10

US UNITS

Vertical Aeration Additional Aeration Aeration Sidewall Conical Surface Conical Dimensional Liquid Percentage

Tank Diameter Depth Depth Area Volume Volume Volume of AOR feet feet feet sq. ft. cubic feet cubic feet gallons Distrib.

SST-02 113.00 14.95 0.00 10,029 0 149,930 1,121,475 50%

SST-03 113.00 14.95 0.00 10,029 0 149,930 1,121,475 50%

20,057 299,860 2,242,950 100% sq.ft. cuft gallons

SI UNITS

Aeration Additional Aeration Aeration

Conical Surface Conical Dimensional Liquid Percentage Tank Diameter Depth Depth Area Volume Volume Volume of AOR meters meters meters sq. meters meter^3 cubic meters liters Distrib.

SST-02 34.44 4.56 0.00 932 0 4,245 4,244,783 50%

SST-03 34.44 4.56 0.00 932 0 4,245 4,244,783 50%

1,863 8,491 8,489,565 100% sq.m. cu.m L

Cincinnati / Northern Kentucky International Airport Sludge Storage Tank No.2 & No.3 - Coarse Bubble Mixing & O2 System

CIRCULAR TANK DIMENSIONS

DESIGN FOR MIXING & O2

6/27/2025

A Division of Red Valve Company, Inc. Page 3 of 10

Applied Values Specific Weight = 62.3156 lb/ft^3

Velocity Dynamic Dynamic Viscosity = 4.25E-05 lbf-s/ft^2 Gradient Viscosity Fluid Temp = 68.00 F G (sec-1) lbf-s/ft^2

Water Level Surge 90-120 15 cfm/1000 cuft for Equalization Tank 2.01E-05 Off Gas Rise Rate = 2.00 ft/sec 90-120 20 cfm/1000 cuft for Aeration Tank to 2500 mg/l MLSS 2.35E-05 Volume of Air in Liquid = 465.50 cuft 90-120 25 cfm/1000 cuft for Aeration Tank to 4500 mg/l MLSS 2.70E-05 Liquid Level Increase = 0.56 inches 90-120 28 cfm/1000 cuft for Aeration Tank to 6500 mg/l MLSS 3.05E-05 90-120 30 cfm/1000 cuft for Aerobic Sludge to 1% solids 3.40E-05 MLSS Concentration = 0 mg/l 90-120 35 cfm/1000 cuft for Aerobic Sludge to 2% solids 3.75E-05 Solids Concentration = 4.0 % Solids 90-120 40 cfm/1000 cuft for Aerobic Sludge to 3% solids 4.00E-05 90-120 45 cfm/1000 cuft for Aerobic Sludge to 4% solids 4.25E-05

Coarse Bubble Volume Volume Diffusers

Tank cu.ft. cu.m. cfm/1000 cuft m3/hr/m3 cfm m3/hr cfm m3/hr

SST-02 149,930 4,245 25.35 1.521 3,800.00 6456.18 15.83 26.901 240.0

SST-03 149,930 4,245 25.35 1.521 3,800.00 6456.18 15.83 26.901 240.0

299,859.60 8491.0 7,600.00 12,912.36 480 cu.ft. cu.m. cfm m3/hr units

Volume Volume Depth Depth Tank cu.ft. cu.m. feet meters ft-lb/sec kW

SST-02 149,930 4,245 15 5 48,979 66.41 88

SST-03 149,930 4,245 15 5 48,979 66.41 88

Cincinnati / Northern Kentucky International Airport Sludge Storage Tank No.2 & No.3 - Coarse Bubble Mixing & O2 System

Airflow Rate Required

Airflow Required for Complete Mixing - Volume Ratio & Gradient Velocity Design Comparison

COARSE BUBBLE DIFFUSER SYSTEM

Design Unit Air Flowrate

Recommended Design Values for Mixing Airflow per Volume Ratio cfm per 1000 cuft liquid

Volume Ratio Mixing Design

Diffuser Model

TFA-3.00

DESIGN FOR MIXING & O2

Velocity Gradient Mixing Design

G, sec-1

Air Flowrate per Diffuser

Equivalent Power

Mean-Squared Velocity Gradient

6/27/2025

A Division of Red Valve Company, Inc. Page 4 of 10

AOR = Actual Oxygen Transferred into wastewater solution SOTR = Oxygen transfer rate based on clean water

AOR / SOTR Ratio 24.8% Airflow per Airflow per Efficiency Total Coarse

Tank AOR AOR SOTR SOTR Airflow Airflow Diffuser Diffuser per foot Diffuser Bubble No. kg/hr lbs/hr kg/hr lbs/hr m3/hr cfm cfm m3/hr depth Efficiency Diffusers

SST-02 53.53 118.01 216.15 476.51 6,456.96 3,800.00 15.8 26.904 0.825% 12.13% 240.0 SST-03 53.53 118.01 216.15 476.51 6,456.96 3,800.00 15.8 26.904 0.825% 12.13% 240.0

107.06 236.02 432.29 953.03 12,913.92 7,600.00 480 kg/hr lbs/hr kg/hr lbs/hr m3/hr cfm units

MLSS Concentration for Activated Sludge Process = 0 mg/l Sludge Process Solids Concentration = 4.00 % Solids

Cincinnati / Northern Kentucky International Airport Sludge Storage Tank No.2 & No.3 - Coarse Bubble Mixing & O2 System

COARSE BUBBLE DIFFUSER SYSTEM

Oxygen Mass Transfer Rates at Applied Airflow

DESIGN FOR MIXING & O2

6/27/2025

A Division of Red Valve Company, Inc. Page 5 of 10

AOR1 AOR as Specified by Owner/Engineer 0 lbs./day 0 kg./day

AOR2 AOR for BOD & NH3 Removal 0 lbs./day 0 kg/day

AOR3 AOR for COD Removal 0 lbs./day 0 kg/day

AOR4 AOR for Post Aeration 0 lbs./day 0 kg/day

AOR5 AOR for Aerobic Digestion 0 lbs./day 0 kg./day

AOR6 AOR per Uptake Rate 5,664 lbs./day 2,569 kg/day

Oxygen Uptake Rate Applied 12.62 mg/l/hr 12.00 mg/l/hr (Recommended for this Process Fluid)

AOR Applied for Design* 5,664 lbs./day 2,569 kg/day AOR Conversion 236.02 lbs/hr (24 hr. day) 107.06 kg/hr (24 hr. day)

* (Maximum Value of AOR1, AOR2, AOR3, AOR4, AOR5 & AOR6)

Selected - Actual Oxygen Required (AOR) Based on an Maximum Value listed below

Sludge Storage Tank No.2 & No.3 - Coarse Bubble Mixing & O2 System Cincinnati / Northern Kentucky International Airport

DESIGN FOR MIXING & O2

6/27/2025

A Division of Red Valve Company, Inc. Page 6 of 10

Specific Weight of Air 0.0669 lb/ft^3 Beginning Flowrate 3700.00 cfm Density of Air 0.00208 slug/ft^3 Ending Flowrate 3800.00 cfm Air Temp in pipe 180.00 deg. F Flowrate Increments 5.00 cfm

20 Total Values Maximum 20.00

Absolute Roughness 1.50E-04 E Linear Length of Discharge 70.00 feet Relative Roughness 1.286E-04 E/D Equivalent Length of Fittings 35.00 feet Discharge Line Nominal Diameter 14.00 inches Equivalent Length of Discharge 105.00 feet Actual Inside Diameter (Disch.) 13.624 inches

Airflow Pipe I.D. Velocity Headloss Headloss Nominal Recommended cfm inches fpm psi inch - H20 Pipe Diameter Max. Velocity

3700.00 13.624 3654.1 0.041 1.15 inches fpm

3705.00 13.624 3659.1 0.042 1.15

3710.00 13.624 3664.0 0.042 1.16 2.00 2790

3715.00 13.624 3668.9 0.042 1.16 3.00 3025

3720.00 13.624 3673.9 0.042 1.16 4.00 3400

3725.00 13.624 3678.8 0.042 1.16 6.00 3495

3730.00 13.624 3683.8 0.042 1.17 8.00 3750

3735.00 13.624 3688.7 0.042 1.17 10.00 3970

3740.00 13.624 3693.6 0.042 1.17 12.00 4200

3745.00 13.624 3698.6 0.042 1.18 14.00 4450

3750.00 13.624 3703.5 0.042 1.18 16.00 4695

3755.00 13.624 3708.4 0.043 1.18 18.00 4950

3760.00 13.624 3713.4 0.043 1.19 20.00 5175

3765.00 13.624 3718.3 0.043 1.19 22.00 5410

3770.00 13.624 3723.3 0.043 1.19 24.00 5970

3775.00 13.624 3728.2 0.043 1.19

3780.00 13.624 3733.1 0.043 1.20

3785.00 13.624 3738.1 0.043 1.20

3790.00 13.624 3743.0 0.043 1.20

3795.00 13.624 3747.9 0.043 1.21

3800.00 13.624 3752.9 0.044 1.21

Cincinnati / Northern Kentucky International Airport Sludge Storage Tank No.2 & No.3 - Coarse Bubble Mixing & O2 System

SYSTEM HEADLOSS THROUGH DROP PIPE SECTION

PIPING DATA

FLOW DATA

EQUIVALENT LENGTHS

AIR DATA

SYSTEM CURVE HEADLOSS OUTPUT

A Division of Red Valve Company, Inc. Page 7 of 10

Specific Weight of Air 0.0669 lb/ft^3 Beginning Flowrate 1150.00 cfm Density of Air 0.00208 slug/ft^3 Ending Flowrate 1250.00 cfm Air Temp in pipe 140.00 deg. F Flowrate Increments 5.00 cfm

20 Total Values Maximum 20.00

Absolute Roughness 1.50E-04 E Linear Length of Discharge 100.00 feet Relative Roughness 2.250E-04 E/D Equivalent Length of Fittings 35.00 feet Discharge Line Nominal Diameter 8.00 inches Equivalent Length of Discharge 135.00 feet Actual Inside Diameter (Disch.) 8.329 inches

Airflow Pipe I.D. Velocity Headloss Headloss Nominal Recommended cfm inches fpm psi inch - H20 Pipe Diameter Max. Velocity

1150.00 8.329 3038.8 0.068 1.88 inches fpm

1155.00 8.329 3052.0 0.068 1.90

1160.00 8.329 3065.2 0.069 1.91 2.00 2790

1165.00 8.329 3078.4 0.069 1.93 3.00 3025

1170.00 8.329 3091.7 0.070 1.94 4.00 3400

1175.00 8.329 3104.9 0.071 1.96 6.00 3495

1180.00 8.329 3118.1 0.071 1.97 8.00 3750

1185.00 8.329 3131.3 0.072 1.99 10.00 3970

1190.00 8.329 3144.5 0.072 2.01 12.00 4200

1195.00 8.329 3157.7 0.073 2.02 14.00 4450

1200.00 8.329 3170.9 0.073 2.04 16.00 4695

1205.00 8.329 3184.1 0.074 2.05 18.00 4950

1210.00 8.329 3197.4 0.075 2.07 20.00 5175

1215.00 8.329 3210.6 0.075 2.09 22.00 5410

1220.00 8.329 3223.8 0.076 2.10 24.00 5970

1225.00 8.329 3237.0 0.076 2.12

1230.00 8.329 3250.2 0.077 2.13

1235.00 8.329 3263.4 0.077 2.15

1240.00 8.329 3276.6 0.078 2.17

1245.00 8.329 3289.8 0.079 2.18 3.30 inches

1250.00 8.329 3303.1 0.079 2.20

AIR DATA

Cincinnati / Northern Kentucky International Airport Sludge Storage Tank No.2 & No.3 - Coarse Bubble Mixing & O2 System

Diffuser Orifice Min. Headloss Required

SYSTEM CURVE HEADLOSS OUTPUT

PIPING DATA

FLOW DATA

EQUIVALENT LENGTHS

SYSTEM HEADLOSS THROUGH DISTRIBUTION PIPE SECTION

A Division of Red Valve Company, Inc. Page 8 of 10

Specific Weight of Air 0.0669 lb/ft^3 Beginning Flowrate 550.00 cfm Density of Air 0.00208 slug/ft^3 Ending Flowrate 650.00 cfm Air Temp in pipe 140.00 deg. F Flowrate Increments 5.00 cfm

20 Total Values Maximum 20.00

Absolute Roughness 1.50E-04 E Linear Length of Discharge 50.00 feet Relative Roughness 3.000E-04 E/D Equivalent Length of Fittings 35.00 feet Discharge Line Nominal Diameter 6.00 inches Equivalent Length of Discharge 85.00 feet Actual Inside Diameter (Disch.) 6.357 inches

Airflow Pipe I.D. Velocity Headloss Headloss Nominal Recommended cfm inches fpm psi inch - H20 Pipe Diameter Max. Velocity

550.00 6.357 2494.9 0.041 1.14 inches fpm

555.00 6.357 2517.6 0.042 1.16

560.00 6.357 2540.2 0.042 1.18 2.00 2790

565.00 6.357 2562.9 0.043 1.20 3.00 3025

570.00 6.357 2585.6 0.044 1.22 4.00 3400

575.00 6.357 2608.3 0.045 1.24 6.00 3495

580.00 6.357 2631.0 0.045 1.26 8.00 3750

585.00 6.357 2653.6 0.046 1.28 10.00 3970

590.00 6.357 2676.3 0.047 1.30 12.00 4200

595.00 6.357 2699.0 0.047 1.32 14.00 4450

600.00 6.357 2721.7 0.048 1.34 16.00 4695

605.00 6.357 2744.4 0.049 1.36 18.00 4950

610.00 6.357 2767.0 0.050 1.38 20.00 5175

615.00 6.357 2789.7 0.051 1.40 22.00 5410

620.00 6.357 2812.4 0.051 1.42 24.00 5970

625.00 6.357 2835.1 0.052 1.45

630.00 6.357 2857.8 0.053 1.47

635.00 6.357 2880.4 0.054 1.49

640.00 6.357 2903.1 0.054 1.51

645.00 6.357 2925.8 0.055 1.53 2.33 inches

650.00 6.357 2948.5 0.056 1.56

Diffuser Orifice Min. Headloss Required

PIPING DATA EQUIVALENT LENGTHS

SYSTEM CURVE HEADLOSS OUTPUT

Cincinnati / Northern Kentucky International Airport Sludge Storage Tank No.2 & No.3 - Coarse Bubble Mixing & O2 System

SYSTEM HEADLOSS THROUGH DISTRIBUTION PIPE SECTION

AIR DATA FLOW DATA

A Division of Red Valve Company, Inc. Page 9 of 10

Total Airflow Required for the Process = 7,600.0 cfm 12,914 m3/hr Number of Operating Blowers = 2.0

Airflow per Blower = 3,800.0 cfm 6,457 m3/hr Mass Rate = 285.83 lbs/min

Barometric Pressure at Site = 14.26 psia 0.984 Bar Inlet Blower Air Temperature at the Site = 100 F 37.74 C

Saturated Vapor Pressure at Site Temperature = 0.9503 psia 6.552 kPa Relative Humidity at the Site = 50%

Applied Blower Efficiency = 55% Pressure at Standard Conditions = 14.70 psia 101.354 kPa

Temperature at Standard Conditions = 68 F 19.98 C Saturated Vapor Pressure at Standard Temperature = 0.3391 psia 2.338 kPa

Relative Humidity at Standard Conditions = 36% Density of Air at Standard Conditions = 0.075 lbs/ft^3 1.201 kg/m3

Headloss - Hydrostatic = 176.40 in. 4.481 m Headloss - Drop Pipe Section = 1.21 in. 0.031 m

Headloss - Longest Manifold Piping Section = 3.76 in. 0.095 m Diffuser Orifice Diam. = 0.5000 in. 12.700 mm

Headloss - Diffuser Orifice = 5.00 in. 0.127 m Headloss - Diffuser Body = 4.00 in. 0.102 m

Total Headloss = 195.87 in. 4.975 m

Absolute Pressure at Top of Drop Leg = 21.31 psia 146.953 kPa 1.470 Bar Gauge Pressure at Top of Drop Leg = 7.05 psig 48.616 kPa 0.486 Bar

R = 1.4797 Discharge Air Temperature = 222.6 F 105.8 C

Blower Airflow at Site Conditions = 4,261.4 acfm 7,241 am3/hr Blower Brake HP = 209.0 HP 155.8 kW

Number of Operating Blowers = 2.0 Airflow per Blower = 4,261 acfm 7,241 Am3/hr

Discharge Pressure* = 7.05 psig 48.616 kPa Blower Brake HP = 209.0 HP 155.8 kW

Applied Blower Efficiency = 55%

ICFM = SCFM on Manufacturer's Blower Curves

CFM = Airflow required for the process

ACFM = Adjusted Airflow for site conditions

ICFM = ACFM +additional losses thru blower and field piping

Cincinnati / Northern Kentucky International Airport Sludge Storage Tank No.2 & No.3 - Coarse Bubble Mixing & O2 System

BLOWER REQUIREMENTS - CONVERSION FOR SITE AIR DENSITY, HUMIDITY & TEMPERATURE

COARSE BUBBLE DIFFUSER SYSTEM

DESIGN FOR MIXING & O2

*Note: Headloss associated to top side, field routed air supply piping, valves and blower fittings must be added to determine total system operating pressure and ICFM rate at blower.

The calculations shown on this page are for the purpose of estimating the diffuser system operating head at the top of the drop pipe and also estimating the airflow requirement after adjusting for site elevation, relative humidity, inlet air temperature, and estimated blower operating efficiency. Actual blower performance may differ after the specific blower efficency is applied along with additional head requirements associated to the blower unit, inter-connecting piping and inline valves.

Blower Performance

Requirements

6/27/2025

A Division of Red Valve Company, Inc. Page 10 of 10

File details come from the government source that posted it. Updated .