This document is a detailed proposal from MacBick Labs and Interiors for laboratory furniture and equipment for the Telluride Wastewater Treatment Plant in Telluride, Colorado. The proposal covers the furnishing and installation of new steel laboratory furniture across multiple project phases, with a total quoted price of $94,544.95. The project includes comprehensive laboratory casework, fixtures, sinks, safety stations, workstations, mobile cabinets, fume hoods, and various specialized laboratory equipment. MacBick proposes a 12-week lead time after receipt of purchase order and approved drawings, with the understanding that the longest lead-time item will govern the entire order's ship date.

The proposal includes specific details on equipment configurations, including eight different elevation setups ranging from sink and safety station arrangements to column and storage configurations. The quote covers furniture and equipment at $78,399.49, freight at $3,678.31, and non-union, non-mechanical installation at $12,467.15. MacBick explicitly notes that fume hoods, mechanical connections, and certain other items are specifically excluded from the proposal. The company offers flexibility in installation, allowing the project to be completed in up to three separate phases if needed, and warns that during peak holiday and summer seasons, lead times may increase by 2-4 weeks.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

August 18, 2025

Kyle and Lori, We propose to furnish, fob factory, new MacBick Steel Laboratory Furniture for Telluride Waster Water Treatment Plant as shown in our drawings date 8/4/2025.

This project can be installed in up to three separate phases if needed.

• Furniture & Equipment: $78,399.49

• Freight (FOB Shipping Point): $3,678.31

• Non-Union, Non-Mechanical Installation: $12,467.15

Grand Total: $94,544.95

Lead-times 12 weeks, after receipt of PO and approved drawings are received.

Lead-time noted above once shop drawings are approved, all measurements are verified, and all questions have been answered. At that point the order will be placed into production and with our vendors, and the lead-time begins. Please be aware that the longest lead-time governs ship date of the entire order. During peak holiday and summer season lead-time tends to increase 2-4 weeks.

SCOPE OF WORK AS PART OF LABORATORY

CASEWORK AND FIXTURES THAT HAS BEEN

SEPARATELY PROCURED BY THE OWNER.

Summary of Quoted Items – Telluride Waste Water Project

General Materials

• Spray paint (Snow White enamel)

• Black non-adhesive cove base

• Base molding corner clips

Elevation 1 – Sink & Safety Station Setup

• Pure water deck-mounted faucet

• Pegboard (30" x 30")

• ADA black drop-in sink (A25)

• Research aprons (knee space panel, wall pedestal, support frames, fillers)

• Alpha shelving (standards, brackets, lip shelves)

• Sink cabinet base (36”)

• 1” Kemresin worksurfaces with cutouts, black backsplash

• Barrier-free safety station

• ADA-compliant mixing faucet

Elevation 2 – Hood & Workstations

• Canopy hood (72” x 30” x 18”)

• Premier fume hood with blower (4 ft)

• Spill containment accessory (4 ft)

• Base cabinets (acid-resistant)

• Alpha adjustable table frame (70”)

• Alpha workstation table with Kemresin top (72”)

• Mobile cabinets (1-drawer/door and 4-drawer units)

Elevation 3 – Column & Storage

• EVO column (84” x 30” x 72”) with shelving brackets

• EVO workstation table (72”) with Kemresin top

• Mobile cabinet (1 drawer + 1 right-hand door)

Elevation 4 – Column & Mobile Storage

• EVO column (84” x 30” x 48”) with shelving

• EVO workstation table (48”)

• Mobile cabinet (4-drawer)

Elevation 5 – Larger Column Setup

• EVO column (84” x 30” x 96”) with shelving

• EVO workstation table (96”)

• Mobile cabinets (1 drawer + 1 left-hand door; 4-drawer unit)

Elevation 6 – Wide Column & Cabinets

• EVO column (84” x 36” x 96”) with shelving

• EVO workstation table (96”)

• Mobile cabinets (cupboard with door; 4-drawer unit)

Elevation 7 – Multiple Workstations & Cabinets

• Alpha adjustable table frames (64”)

• Alpha free-standing Kemresin tables (66”)

• EVO column + shelving (96”)

• EVO workstation table (96”)

• Multiple mobile cabinets (cupboards, drawers, and file drawers)

Elevation 8 – Final Column Setup

• EVO column (84” x 30” x 72”) with shelving

• EVO workstation table (72”)

• Mobile cabinet (cupboard with door)

Included:

▪ Non-Mechanical Installation

▪ Freight Charges

▪ Shop Drawings

▪ Project Coordination

All other items are specifically excluded. Including fume hoods and mechanical connections of any kind.

All quotes are subject to possible surcharges from material suppliers and fuel.

Thank you for the opportunity to be of service again. We look forward to working with you on this project and future projects.

If anyone has questions or needs additional clarifications, please let me know. Thank you for the opportunity to do business!

Bud Wittmer

Quote prepared by Bevin Carter, Macalaster Bicknell “MacBick”

ARCHITECT

CONTRACTOR

SHEET INDEX

Field dimensions have been taken

For Internal Use

Color selections have been made For fabrication and installation

Space Reserved for Approval Stamp

Revise and re-submit for approval

Make changes as noted and proceed with fabrication

Select One of the Following Prior to Release

Signature : Date:

Approved, proceed with fabrication

As built drawings

Submittal Date: 07-11-25 Revisions:

OWNER

VICINITY MAP

Project Vendors:

SPECIFICATION SECTIONS

Telluride Wastewater

Telluride, CO

Section 11610 - Laboratory Fume Hoods Section 12345 - Laboratory Casework

Name Address City, CA Zip Contact:

Phone: (___) ___-____ Cell: (___) ___-____ Fax: (___) ___-____ Email: ____@____.com Purchase Order #

Name Address City, CA Zip Phone: (___) ___-____ Fax: (___) ___-____

PROJECT MGR.:

Phone: (___) ___-____ Cell: (___) ___-____ Fax: (___) ___-____ Email: ____@____.com

PROJECT SUPT.:

Phone: (___) ___-____ Cell: (___) ___-____ Fax: (___) ___-____ Email: ____@____.com

Name Address City, CA Zip Contact:

Phone: (___) ___-____ Fax: (___) ___-____ Email: ____@____.com

Sheet # Quantity Description 1 Cover Sheet

N1 thru N5 7 Notes & Schedules F1 & F2 2 Floor Plans E1 thru E8 8 Elevations & Tops H1 thru H2 2 Fume Hood Details

Treatment Plant Bud Wittmer

Director, Design & Construction

724-612-1764, cell bud.wittmer@macbick.com www.macbick.com 1200 Abernathy Rd Ne, , Suite 450, Atlanta, GA 30328 855-460-7817, office

MACBICK PROJECT MANAGER

MacBick PROJECT NUMBER

1) All wall to wall dimensions must be field verified prior to release of casework, tops and fume hoods for fabrication.

2) +- Indicates area of casework to be reduced or increased based on field verified dimensions. MacBick drawings resemble architect's prints.

Cabinet and filler sizes may vary depending on final wall to wall measurements. MacBick requests that during the submittal review, the architect/owner indicate on shop drawings which cabinet(s) should be modified when wall to wall measurements vary from document dimensions. This action will assist MacBick in expediting the ordering of the casework. Please note that cabinet modifications will not be revised until final wall-to-wall measurements are taken.

3) Casework color and work surface color are to be selected prior to release of any material for fabrication.

4) All furring, blocking, backing / in wall backing to be furnished & installed by others, N.I.C..

5) These production drawings are an interpretation of the ideas expressed by the architect. They provide a medium where MacBick may suggest modifications to the architect's drawings. They are also a common language between MacBick, the architect and general contractor.

6) These production drawings are in accordance with our most recent quotation. Should changes be made, we reserve the right to adjust price accordingly.

7) General contractor to verify if finished flooring is to be installed before the casework is installed. If finished flooring is to be installed before the casework, please verify if flooring is flat up to the wall or has a cove up the wall. Provide radius of cove, if applicable.

8) Tables are not anchored to floor. Supplied with adjustable plastic swivel glides. Tables to be assembled and moved into place.

1) Base cove / base molding supplied and installation by Division 09.

2) Plumbing and/or piping items will be supplied and installed by Division 15.

3) Duct work, duct transition and / or exhaust fans will be supplied and installed by Division 15.

4) Electrical and/or wiring items will be provided and supplied and installed by Division 16

Elevation Number Sheet Number

Revision Cloud Designation

Section or Detail Symbol

Elevation & Plan Symbol

Detail Number Sheet Number

A) In order to provide the finest quality casework and furnishings and to assist in proper coordination of casework delivery and installation activity with the other trades on the project, the following criteria has been established and defines the required degree of building readiness to facilitate the start of installation. It is imperative that these guidelines be met in order to minimize, or eliminate the potential damage to casework and equipment prior to acceptance by the end user. Installation firms should utilize this criteria to determine job site readiness during their pre-installation inspections.

B) From the earliest stages, project schedules should take into account the following parameters:

1) The building areas requiring the installation of casework & furnishings are to be dried-in and unexposed to any adverse weather conditions which may damage finished materials.

2) For proper curing of epoxy sealant and adhesives, interior building temperatures are not register below 65 degrees relative humidity.

3) Interior building temperature is not to exceed 80 degrees to avoid undue drying of materials which could cause structural fatigue and damage.

Additionally, frequent or excessive changes in temperature or humidity levels during the course of installation, or once casework and equipment is installed, must be avoided to prevent damage.

4) Moisture levels should never exceed 60% relative humidity.

5) Windows and exterior doors must be installed.

6) All overhead mechanical, electrical, plumbing rough-in work, overhead soffits or ceiling grid (with or without acoustical ceiling) is to be complete prior to delivery of casework

7) Walls/partitions (whether framed, demountable, or masonry) must be in place. It is recommended that all painting be completed prior to delivery of casework and furnishings. Walls/partitions must have a minimum of primer paint applied prior to installation.

8) Wood or metal blocking must be installed in walls prior to delivery of casework.

9) Overhead lighting must be installed and connected prior to installation.

10) Flooring required to be placed under casework and furnishing must be installed prior to installation.

11) All floors must be level within acceptable trade tolerances. Specifically, the floor must be within 1/8" of level per10 foot of run.

a) DIMENSIONS ON SHOP DRAWINGS ARE TAKEN FROM HIGHEST POINT ON FLOOR.

12) In order for delivery of casework and furnishings to take place the following general guidelines must be applicable prior to the shipment of materials:

a) Lockup rooms available

b) Loading dock accessible

c) Entry to elevator free of charge or hoist must be present

d) Unobstructed use of hoisting during delivery and easy distribution of materials must be possible

e) Staging area for materials to be available

f) Areas of installation to be broom clean

g) Minimum trade interference in area of installation.

ER 30

General:

Products:

Materials:

Quality ControlQC

CFOI

OD

OFCI

OFOI

NIC

SIM

REF

OH

EQ

ID

Contractor Furnish Owner Install

Outside Diameter

Opposite Hand

Owner Furnish Contractor Install Owner Furnish Owner Install Not In Contract

Equally Spaced

Reference

Similar

Inside Diameter

Centerline

GA Gauge

RH Right Hand

LH Left hand

UC Under Counter

ADA American Disabilities Act ADJ Adjustable AFF Above Finished Floor

CO Cut-Out

(E) Existing EQ Equipment

MIN

MAX

Minimum Maximum

NTS

DIA

Not To Scale

Diameter

On-CenterOC

CONT Continuous

LF Linear Foot

UNO Unless Noted Otherwise

SF Square Foot

CU Cubic Foot

VIF Verify In Field

Dimensioning:

Equipment:

CIF Cut In Field CO Cutout

Work surface type, see schedule for material.

Indicates utility space, rough- ins to be located in this area.

Indicates rough-in locations above ceiling line.

Work surface height 36" AFF = Stand-up

34" AFF = ADA

30" AFF = Sit-down

FE Finished End/Edge FJ Field Joint

Indicates center line of in-wall backing.

In-wall backing by others

E1

E1

4"

Epoxy ResinER

Distilled Water

Plastic Laminate

Vacuum Natural Gas Compressed Air

Stainless Steel

DI

V G A

PLY

SS

PL

CW Cold Water

H/CW Hot & Cold Water Mixing

EyewashEW

NitrogenNIT

PVC

HDWD

Polyvinyl Chloride

CDA Compressed Dry Air

Hardwood Plywood

Solid PhenolicSP WD Wood

ElectricalE

OxygenOXY

Deionized WaterDW

HW Hot Water

Service Fixtures:

Epoxy Resin, Marine EdgeERM

MacBick General Notes

Project Specific Notes

Building Condition Guidelines

Abbreviations and Symbols

Scope of Includes & Excludes

Work Surface

Constant Air Volume Fume Hood

Knee Space Opening

Peg Board

Paper Towel Dispenser

Variable Air Volume

WKSF

CAV

FH

KS

PB

PTD

VAV

Soap DispenserSD

SinkSK Cup SinkCS

Knee Space PanelKSP

AS Adjustable Shelf

KEWAUNEE STEEL

Color Option Category Name Color Color Code

Cabinets SNOW WHITE 78

Evolution Frames & Tables SNOW WHITE 78

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o ffi ce w w .m ac bi ck .c om

N1

None

N ot es , A bb re vi at io ns

S ym bo ls

Sink Schedule Sinks:

Arch.

Ref.

MacBick Ref. Model # Manufacturer Color / Finish Type Sink ID Size Outlet Accessories Cut Out Quantity

A55 A55 Durcon Black Drop-in 25"x15"x5" S03-R U-SS2 Poly Stopper 1

Service Fixture Schedule Water Fixtures:

Arch. Ref. MacBick Ref. Model # Manufacturer Service Description Finish Cut Out Quantity

L414VB-BH L414VB-BH Watersaver Hot/Cold Water Mixing Faucet, Deck Mount, Blade Handles, 6" Swivel Gooseneck, Vacuum Breaker Polished Chrome 13 8"Ø 1

L7833 L7833 Watersaver De-Ionized Water DI Faucet, Deck Mount, Round Nylon Handle, Polypropylene 1"Ø 1

Emergency Fixtures:

SSBF994 SSBF994 Watersaver Safety Station Barrier-Free Safety Station Stainless Steel 1

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

N2

None

Sc he du le s

Butt Splash (Field Applied)

1"

Epoxy Work Surface Edge

1"

Splash As

ShownDrip Groove

8"

8"

8" Machined Bevel , 4" Radius Edge, or

2" Radius Edge

1" Thick Splash Splash Thickness

Work Surface Thickness

1" Thick

Solid Phenolic Work Surface Edge

(**Not Available in Phenolic Resin**)

Splash Edge

Edge as Selected

Solid Phenolic Work Surface Material

Solid Phenolic Toplab Required

Solid Phenolic Athlon Required

**11 4" Thick**

(Standard)

16"

1"

Solid Phenolic Splash Butt - Field Applied (Standard) Coved Splash

1"1 4"

8" Machined Beveled

Edge

4" Radius Machined

Edge

4" Marine Top Dish w/ 14" Radius Edge, w/ Applied Splash Only

Epoxy Resin Splash Butt - Field Applied (Standard)

Field Joint Spacing is not Included in Work Surface Dimensions. Work Surface Manufacturer to Calculate for 18" Field Joint Spacing.

Epoxy Resin Color: Black Onyx

Solid Phenolic Color: Black

Drop in Epoxy Sink Detail

2" Radius

Sink Depth is to the Edge of Drain Hole

4"

.813"

8" Typ. Wall

.313"

8" Radius

Inside Length & Width Dimension Apply at this Point

Drop in Epoxy Sinks Required Cutout as Listed on Sink Schedule

4" Thick Splash

8" Beveled Edge

4" Radius Edge

2" Radius Edge

4" Thick

8" Machined Beveled Edge

4" Radius Machined Edge

Epoxy Resin and Solid Phenolic Compact Work Surface Construction Details and Options

1" 1"1 4" 1

4" Marine Top Dish w/

8" Machine Beveled Edge, w/ Applied Splash Only

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

N3

None

W or k Su rfa ce

D et ai

TAYLOR TX

FACTORY

FACTORY

TAYLOR TX

R1.5000

R1.6250

25.0000

26.6250

15.0000 16.6250

TOP VIEW

4.7500

5.75000.5000 R1.5000

SECTION VIEW

3.5000

3.5000

4° SLOPE

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

N3

None

Si nk s an d Pe g Bo ar ds

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

N4

None

Pl um bi ng

F ix tu re

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

N4

None

Sa fe ty S ta tio n

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

N5

None

C ab in et

H ar dw ar e

Lab

212A

Shower 212C

Bathroom & Shower

214D

Janitor

Toilet

Hall

Hall

Headworks

1.18

A81C010224 A11C322202

A81C010255 A10C3155-00_0

F13M000248-00, 2 F21M1272-00, 2 F63M0272-00, 4

BR

SC

-0

0_

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

F1

1/4"=1'-0"

Fl oo r P la n, O ve ra ll Pa rti al

Lab

212A

Shower 212C

214D

Toilet

Hall

1.18

A81C010224 A11C322202

A81C010255 A10C3155-00_0

F13M000248-00, 2 F21M1272-00, 2 F63M0272-00, 4

BR

SC

-0

0_

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

F2

None

Fl oo r P la n, P ar tia l

E1

LAB 209

Arch Elev. Ref.: 2/A5.0

BR

SC

-0

0_

A10C3155-00_0

F13M000248-00, 2 F21M1272-00, 2 F63M0272-00, 4

31 30

362455

36118

L7833 L414VB-BH

A55 S03-R

Ø13 8Ø3

CUTOUT FOR A DURCON A55

DROP-IN SINK, 25"x15"x5"

PHASE 1

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

E1

1/2"=1'-0"

El ev at io ns a nd T op

BR

SC

-0

0_

BR

SC

-0

0_

48.00

38.10 Interior Width

48 72

149105

E2

LAB 209

Arch Elev. Ref.: 5/A5.0 PHASE 2

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

E2

1/2"=1'-0"

El ev at io ns a nd T

WINDOWWINDOWWINDOW

E3

LAB 209

Arch Elev. Ref.: 6/A5.0

4 741

PHASE 2

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

E3

1/2"=1'-0"

El ev at io ns a nd T

E4

LAB 209

Arch Elev. Ref.: 7/A5.0

51 17 186

PHASE 2

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

E4

1/2"=1'-0"

El ev at io ns a nd T

E5

LAB 209

Arch Elev. Ref.: 8/A5.0

PHASE 2

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

E5

1/2"=1'-0"

El ev at io ns a nd T

E6

LAB 209

Arch Elev. Ref.: 8/A5.0

PHASE 2

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

E6

1/2"=1'-0"

El ev at io ns a nd T

E7

LAB 209

Arch Elev. Ref.: 9/A5.0

4132351

66 6697

PHASE 3

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

E7

1/2"=1'-0"

El ev at io ns a nd T

E8

LAB 209

Arch Elev. Ref.: 4/A5.0

4132351

PHASE 1

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

E8

1/2"=1'-0"

El ev at io ns a nd T

Top View

19.7

16.1

4.0

2.0

18.0

30.0

36.00

8.00

72.00

30.0

8.00

Front View Side View

72.0

21.0

8.0 48.0 8.0

1.0

0.375 x 1.125 long slotted hole typ (4) places

CFM at Static Pressure - Inches H₂O

0.17" 0.24" 0.31" 0.45" 0.49" 0.89" 2.50"

425 550 638 825 850 1275 2550

Ø12.8" I.D.

Exhaust Collar

Baffle

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

H1

None

Fu m e H oo d

D et

TOP VIEW

FRONT VIEW SIDE VIEW

Scaled to fitSCALE:

Date:

Checked By:

Sheet No.

Approved By:

Drawn By:

Drawing #

Rev Date

FU

M E

H O O D S fo r:

100400040

June 2023

I.D.

4" x 7" Junction Box

37.50 Viewing Height

Service Pass-Through

Top Access Panel

Header Corner Post

Sash

Operating Instructions /Access Cover

C. Alumbaugh

LED Light Fixture

Single Point Junction Box

Sash Weight

Sash

Integral Blower

Blower Switch

28.00 Sash

Opening

8.09

Ø10.81

115v Duplex

Light Switch

115v Duplex

R1.00 This Edge Only

48.00

R0.56±0.12 At Top Surface TYP 4 Corners

Ø2.50 Hole TYP-2 Places

3.71 TYP

Ø1.50 Hole TYP-2 Places

3.67

2.44 TYP

2.28

TYP

0.38 TYP-REF

4.94

2.62

4.94

30.00

18.00

16.28 3.71

2.30

31.70

Air Foil 1.25

Baffle

10.32

48.00

38.10 Interior Width 59.00

23.30 Interior Depth

Ø1.00

7.00 Raised Sash

15.70

1.70

Airflow Volumetric Rate (CFM) @ Static Pressure (inches of water)

Nominal Ductwor k Diamete r

Equivale nt

Resistan cet

HP

Face Velocity

(fpm) 100% open

(28") 100 725 @ 0.17" 10" 75 1/3 tIn feet of straight duct

Work Surface (Sold Separately)

WORK SURFACE (Sold Separately) 95004-XX (See General Description) for XX value) Model number varies based on sink location selection

Factory Prepared for Air Flow Monitor/Alarm (Sold Separately)

Factory Prepared for Electrical Receptacles (Two Per Side, Sold Separately)

Factory Prepared for Service Fixtures (Four Per Side, Sold Separately)

SHEET JOB NO.

DRAFTER

CHECKER

R

EV

IS

IO

N S

SCALE

DATE

Pr oj ec t

Sh ee t T itl e:

JRK

BW

54321 Te llu rid e W as te w at er

Te llu rid e, C o

Tr ea tm en t P la nt

A be rn at hy

R d

N E, S ui te

At la nt a, G

A

5-

0-

, o w .m ac bi ck .c om

H2

None

Fu m e H oo d

D et

File details come from the government source that posted it. Updated .