25-0627 Telluride WWTP Lab Remodel Drawings.pdf
PDF 18 MB Posted
- Solicitation number
- 2025-8
- Issued by
- Rio Blanco County, Colorado
About this file
This document is a comprehensive set of architectural and engineering construction documents for the Telluride Wastewater Treatment Plant Lab Upgrades project, prepared by Eidos Architects in collaboration with Bighorn Consulting Engineers and JVA Consulting Engineers for the Town of Telluride, Colorado. The project involves a three-phase renovation of an existing laboratory and adjacent storage room, with work scheduled to commence in February 2025. The scope includes expanding and updating laboratory space, adding windows to specific offices, replacing the existing roof with a new EPDM membrane roofing system, and making structural modifications to the headworks to accommodate equipment upgrades.
The project is located at 12000 CO-145 in Telluride, spanning a 3.247-acre site zoned as public. The renovation will include installing new mobile lab tables, a 48" fume hood, emergency eyewash and shower stations, rubber tile flooring, new electrical panels, and reconfiguring mechanical systems. The estimated construction timeline includes a permit set issued in December 2024, with subsequent responses to comments in February 2025. The architectural plans detail phased demolition and reconstruction, mechanical and electrical system updates, and specific requirements for equipment installation, ensuring minimal disruption to the existing wastewater treatment plant operations while modernizing the laboratory infrastructure.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Address: 12000 CO-145 Telluride, Colorado 81435
Site Area: 3.247 Acre
Zone: Public
Site Information
Drawing Index
The existing lab and adjacent storage room will receive a three phase renovation to provide an expanded and updated laboratory space. A window will be added to offices 214 D and 214 E. The existing roof will be replaced with a new EPDM membrane roofing system. The existing headworks will receive structural modifications to accomodate equipment upgrades.
Scope of Work
ATC ACOUSTICAL TILE CEILING
ADJ. ADJUST(ABLE), ADJACENT
A.F.F. ABOVE FINISHED FLOOR
ALUM. ALUMINUM
ALT. ALTERNATE
APPROX. APPROXIMATE
ARCH. ARCHITECT / ARCHITECTURAL
ANOD. ANODIZED
APPROV. APPROVED
BD. BOARD
BLDG. BUILDING
BLK. BLOCK
BLKG. BLOCKING
B.M. BENCH MARK
BOT. BOTTOM
B.O. BOTTOM OF
BRG. BEARING
BSMT. BASEMENT
B.U.R. BUILT UP ROOF
CTR. CENTER, CENTERED
CIR. CIRCLE
CIRC. CIRCUMFERENCE
C.J. CONTROL JOINT
CLG. CEILING
CLR. CLEAR
CMU CONCRETE MASONRY UNITS
COL. COLUMN
COMB. COMBINATION
COMP. COMPACT(ED), COMPOSITION
CONC. CONCRETE
CONT. CONTINUOUS
CONST. CONSTRUCTION
COORD. COORDINATE
CORR. CORRIDOR
CPT CARPET
C. TILE CERAMIC TILE
D. DEEP, DRYER
DBL. DOUBLE
DEMO. DEMOLITION
DEPT. DEPARTMENT
D.F. DRINKING FOUNTAIN
DTL. DETAIL
DIAG. DIAGONAL
DIA. DIAMETER
DIM. DIMENSION
DISP. DISPENSER
DISPL. DISPOSAL
DIV. DIVISION
DN. DOWN
DR. DOOR
D.S. DOWN SPOUT
DWG. DRAWING
E. EAST
EA. EACH
ELEC. ELECTRIC, ELECTRICAL
ELEV. ELEVATION, ELEVATOR
EQ. EQUAL
EQMT. EQUIPMENT
E.W.C. ELECTRIC WATER COOLER
EXH. EXHAUST
EXIST., (E) EXISTING
ETR. EXISTING TO REMAIN
EXT. EXTERIOR
EXP. EXPANSION
E.J. EXPANSION JOINT
F.D. FLOOR DRAIN
F.E. FIRE EXTINGUISHER
F.F.E. FINISH FLOOR ELEVATION
FIN. FINISH(ED)
FIXT. FIXTURE
FLR. FLOOR
FND. FOUNDATION
F.R. FIRE RATED
FRMG. FRAMING
FRT. FIRE RETARDANT TREATED
FRZ. FREEZER
FTG. FOOTING
FUT. FUTURE
GA. GAUGE
GALV. GALVANIZED
G.B. GRAB BAR
GRND. GROUND
G.C. GENERAL CONTRACTOR
GYP. BD. GYPSUM BOARD
H. HIGH
H.B. HOSE BIB
HC. HANDICAPPED
H.D. HEAVY DUTY
HDWR. HARDWARE
H.M. HOLLOW METAL
H.O. HOLD OPEN(S)
HORZ. HORIZONTAL
HT. HEIGHT
HTG. HEATING
I.D. INSIDE DIAMETER
INCL. INCLUDE, INCLUDING
INSUL. INSULATION, INSULATED
INT. INTERIOR
JT. JOINT
JST. JOIST
KIT. KITCHEN
L. LENGTH
LAB. LABORATORY
LAM. LAMINATE
LAV. LAVATORY
L.F. LINEAL FEET
LB., # POUND
LVR. LOUVER
MAS. MASONRY
M.O. MASONRY OPENING
MAT’L. MATERIAL
MAX. MAXIMUM
MECH. MECHANICAL
MED. MEDIUM
MFR. MANUFACTURER
MH. MANHOLE
MIN. MINIMUM
MISC. MISCELLANEOUS
MM. MILLIMETER(S)
MTL. METAL
(N) NEW
N. NORTH
NEC. NECESSARY
N.I.C. NOT IN CONTRACT
NO., # NUMBER
NOM. NOMINAL
N.T.S. NOT TO SCALE
O.D. OUTSIDE DIAMETER
O.C. ON CENTER
OH. OVERHEAD
O.H. OPPOSITE HAND
OPN’G. OPENING
OPP. OPPOSITE
O.S.B. ORIENTED STRAND BOARD
PART. PARTITION, PARTICLE
PER. PERIMETER
P-LAM. PLASTIC LAMINATE
PLBG. PLUMBING
PROP. PROPERTY
P.T. PRESSURE TREATED
PT. PAINT(ED)
P. TILE PORCELAIN TILE
Q. TILE QUARRY TILE
R. RISER, RADIUS
RB. RUBBER BASE
RE. REFER TO
REC. RECESSED
REF. REFERENCE
REFL. REFLECTED
REM. REMOVE, REMOVABLE
REQ’D. REQUIRED
RET. RETURN
REV. REVISION
RM. ROOM
S. SOUTH
S.B. SPLASH BLOCK
SCHED. SCHEDULE
SECT. SECTION
S.F. SQUARE FOOT
SHWR. SHOWER
SHT. SHEET
SIM. SIMILAR
S.O.G. SLAB-ON-GRADE
S.O.G. SLAB-ON-GRADE
SPEC. SPECIFICATION
SPECS. SPECIFICATIONS
SPK. SPEAKER
SQ. SQUARE
ST. STAIN
STD. STANDARD
STL. STEEL
STR. STAIR
STRUCT. STRUCTURE, STRUCTURAL
SUSP. SUSPENDED
SYM. SYMMETRICAL
SYS. SYSTEM
T. THICK, TREAD
T.B.D. TO BE DETERMINED
TEMP. TEMPORARY, TEMPERED
T & G TONGUE AND GROOVE
T.O.__ TOP OF _____ (E.G. STEEL)
TLT. / TOIL. TOILET
T.P. TOILET PAPER
T.S. TUBE STEEL
TYP. TYPICAL
UC. UNDERCUT
U.N.O. UNLESS NOTED OTHERWISE
V.B. VAPOR BARRIER
V.C.T. VINYL COMPOSITION TILE
VENT. VENTILATOR
VERT. VERTICAL
VEST. VESTIBULE
VIN. VINYL
V.I.F. VERIFY IN FIELD
W. WIDE, WEST, WASHER
W/ WITH
W/O WITHOUT
W.C. WATER CLOSET
WD. WOOD
WDW. WINDOW
WIN. WINDOW
W.R. WATER RESISTANT
WSCT. WAINSCOT
W.W.F. WELDED WIRE FABRIC
Abbreviations List
Section Detail
Building & Wall Section
Plan Detail
N
Room Name
150 SF
3A6
A 5.0x
SIM
Wall Type Identification
Elevation Level
Room Identification
Window Identification
Door Identification
Revision Tag
North Arrow
Detail Number
Sheet Number
Room Name
Room Number
Door Number
Hollow Metal
Revision Number
Spot Elevation
100'-0"
Interior Elevation
Detail Number
Sheet Number
1A
1C
1D 1B
N
Curtain Wall Storefront
C1 A1
Wall Type
Wall Width (See Type For Actual Width)
Wall
A5.0x
Optional Note
Wood
.H1 W1
Indicates True North
A 5.0x
SIM
Door Swing
Room Area
S Modifying Suffix (See Type)
View Name 1/8" = 1'-0"
Plan Identification View Name
View Scale
1. View Name 1/8" = 1'-0"
Detail Identification
View Number View Name
View Scale
A 5.0x
SIM
Level Name
Level Height
Height
Grid Lines
Existing Grid
Grid Identification
Detail Number
Sheet Number
Detail Number
Sheet Number
Level
100' - 0"
Symbols Legend
BATT INSULATION
CMU
BRICK
CONCRETE
EARTH
METAL STUD
PLYWOOD
RIGID INSULATION
STEEL
TILEGYPSUM BOARD
WOOD BLOCKING
DRAINAGE FILL
TERRAZZO
FINISH WOOD STONE
WOOD STUD
Symbols Legend
N
Addition toLab Upgrades to
5400 Greenwood Plaza Blvd.
Greenwood Village, CO 80111 Phone: 720.200.0630
Architect
Eidos Architects, PC
Owner Information
/2
/2
:3 :1
P
M C
U s e rs \m ru b io \D o c u m e n ts
\2
T e llu ri d e W
W T
P A
C e n tr a l_
M R u b io e id o s a rc h .c o m
.r vt
Telluride Wastewater Treatment Plant Town of Telluride
Telluride, Colorado
A0.0
Response to Comments
February 7, 2025
Eidos Project No.23019
T e llu ri d e W a s te w a te r T re a tm e n t
P la n t
E id o s P ro je c t
N o
.2
Town of Telluride P.O. Box 397
Telluride, CO 81435 Phone: 970.728.2177
M / E / P Engineer
Bighorn Consulting Engineers, Inc.
386 Indian Road Grand Junction, CO 81501 Phone: 970.241.8709
Structural Engineer
JVA Consulting Engineers
817 Colorado Ave., Suite 301 Glenwood Springs, CO 81601 Phone: 970.404.3100
General
A0.0 Cover Sheet
A0.1 General Notes
A0.2 Code Plan, Analysis, & Legend
Structural
S0.1 2018 IBC Statement of Special Construction
S1.0 Headworks Demolition and Floor Plan
S1.1 Office Window Addition
Architecture
A1.0 Demolition Floor Plan & Floor Plan - Phase 1
A2.0 Demolition Floor Plan & Floor Plan - Phase 2
A3.0 Demolition Floor Plan & Floor Plan - Phase 3
A5.0 Interior Elevations, Room Finish Schedules
A7.0 Reflected Ceiling Plan
A8.0 Roof Plan
Mechanical
MEC1-0 Mechanical / Electrical Code Compliance
M0-1 Mechanical Cover Sheet
M1-1 Mechanical - Demolition Floor Plan & Floor Plan Phase 1
M1-2 Mechanical - Demolition Floor Plan & Floor Plan Phase 2
M1-3 Mechanical - Demolition Floor Plan & Floor Plan Phase 3
M1-4 Mechanical - Roof Plan
M2-1 Mechanical - Schedules
Plumbing
P0-1 Plumbing Cover Sheet
P1-1 Plumbing - Demolition Floor Plan & Floor Plan Phase1
P1-2 Plumbing - Demolition Floor Plan & Floor Plan Phase2
P1-3 Plumbing - Demolition Floor Plan & Floor Plan Phase3
P2-1 Plumbing Schedules
Electrical
E0-1 Electrical Cover Sheet
E1-1 Lighting - Main Level Demo RCP & RCP Phase 3
E2-1 Electrical - Demolition Floor Plan & Floor Plan Phase 1
E2-2 Electrical - Demolition Floor Plan & Floor Plan Phase 2
E2-3 Electrical - Demolition Floor Plan & Floor Plan Phase 3
E2-4 Electrical - Roof Plan
E3-1 Electrical Schedules
E3-2 Electrical Details
Site Vicinity
Mark Date Description
12-04-24 100% CDs
12-20-24 Permit Set
1 02-07-25 Response to Comments
REMOVED FROM SCOPE OF WORK
1. Do not scale the drawings. The Contractor shall field verify all dimensions before construction. If there are any discrepancies, the Contractor shall notify the Architect before proceeding with the Work.
2. All dimensions on the drawings are to the face of stud, masonry and foundation walls unless noted otherwise.
3. All angles shown on the plans are 90 degrees unless noted otherwise.
4. Refer to the Reflected Ceiling Plans and Code Plans for fire-rated wall locations.
5. The Contractor shall coordinate and implement all safety measures requested and/or required by the local Fire Marshal, Health Department, Building Officials, and other authorities having jurisdiction on the project.
6. The Contractor shall maintain the security of the building and construction site throughout the entire project.
7. The Contractor shall coordinate all items provided or installed by the Owner or the Owner's Subcontractors so work on those contracts and this may be carried out smoothly.
8. The Contractor shall provide the blocking/backing in walls as required to support all wall-hung accessories, hardware, and cabinets.
9. All penetrations in surfaces exposed to weather, fire walls, surfaces exposed to view, and other similar conditions shall have pipe sleeves or final assemblies fit tight to surrounding construction. Penetrations in fire rated assemblies shall be sealed as required to maintain the integrity of the assembly.
10. The Contractor shall provide a transition strip at all dissimilar floor materials.
11. The Contractor shall provide control joints in walls where gypsum board is placed in alignment with walls of another material.
12. The Contractor shall review the Structural, Mechanical, Electrical, and all other related drawings and documents for additional project requirements. No extras will be allowed for work shown in any part of these drawings or described in any part of the Project Manual.
13. Refer to sheet A3.0 for floor pattern and striping details.
14. Refer to sheet A5.0 for room finish.
15. The Contractor shall patch, repair, and/or paint all existing surfaces affected by construction activities to match adjacent surfaces.
16. The Contractor shall be responsible for patching, leveling, and/or grinding smooth all existing floors for the installation of new flooring materials.
17. The Contractor shall patch, repair and/or repaint all existing walls at conditions where existing fixtures are removed. See Architectural, Mechanical, Plumbing, Electrical, and demolition drawings for locations.
18. The Contractor shall verify rough-in dimensions with the manufacturer for all new, existing, and reused equipment to ascertain that the equipment will fit in the scheduled locations.
19. The Contractor shall notify the Architect immediately regarding damage having potential structural implications and upon encountering any unexpected existing conditions that could affect the work as required by the Construction Documents.
20. Existing doors that are to remain are unnumbered.
21. Shaded areas denote existing building to remain.
General Notes
1. The Contractor shall coordinate and schedule all construction activities with the Owner to allow the Owner to continue to occupy the facility while construction activities are occurring.
2. Provide temporary barricades and other protection required to prevent injury to people and damage to adjacent buildings and facilities to remain. Temporary dust partitions shall be insulated and constructed of metal studs at 24” O.C. Partition shall seal off area of demolition from the passage of dust and noise. Partition shall be of finished and painted Type ‘X’ gypsum board on the visible side.
3. The Contractor shall maintain all existing exit ways and shall not block any exit paths. If an exit path must be blocked, an alternative means of egress shall be provided as approved by the authorities having jurisdiction on the project.
4. The Contractor shall coordinate the salvage of all existing materials, equipment, and fixtures with the Owner. The Owner retains salvage rights to all items removed from the building. Items which the Owner does not wish to keep shall become the property of the Contractor.
5. The Contractor is responsible for properly removing and legally deposing of all demolished items from the site. On site sale, disposal, or incineration of demolished items is not permitted.
6. The existing utilities are to remain in service and protected against damage during demolition activities. The Contractor shall notify the Owner at least forty-eight hours in advance of any interruptions to utilities.
7. Remove, replace, patch, and repair materials and surfaces cut or damaged during demolition activities, by methods and with materials and using approved contractors so as not to void existing warranties.
8. Protect construction indicated to remain against damage and soiling during demolition activities. The Contractor shall be responsible for repairing and replacing any existing items or conditions that are damaged.
9. The Contractor shall coordinate the removal of existing wall, floor, and ceiling finishes with the Room Finish Schedule.
10. Before removal, document the condition of all existing items scheduled to be salvaged and/or relocated. The Contractor shall disconnect all existing equipment which is to be salvaged and/or relocated and coordinate with the Owner for temporary storage of such items.
11. The Contractor is responsible for the removal of all supports, accessories, and conveyances related to equipment and fixtures shown to be removed on the construction documents.
12. Hazardous materials testing reports are included in project specifications. Limited areas of asbestos are present. If suspected additional hazardous materials are encountered, do not disturb; immediately notify the Architect and the Owner. Hazardous materials shall be removed by the General Contractor.
13. Solid lines on the drawings represent building items to remain.
14. Dashed lines on the drawings represent walls and other items to be removed from the building.
15. The drawings are diagrammatic and may not show all the demolition that is required. The Contractor shall visit the building to document all existing conditions and determine the extent of demolition that will be required to construct the project as it is documented.
Demolition Notes
RCP General Notes
1. Refer to the Mechanical and Electrical drawings for fixtures and equipment not shown here and for mounting locations of items where no ceiling is required or indicated.
2. The Contractor shall center all fire sprinkler heads, fire alarm devices, technology, security, and other mechanical and electrical ceiling devices in the ceiling tiles unless noted otherwise.
3. The Contractor shall submit a layout of all gypsum board ceiling control joints for review prior to proceeding with construction.
4. The Contractor shall center ceiling grids within each space unless noted otherwise.
5. Coordinate the sequence of construction of the various trades in the project to maintain the ceiling heights indicated on the Reflected Ceiling Plans. If there is a discrepancy, notify the Architect before proceeding with the Work.
1. The Contractor shall remove all existing electrical devices when they are affected by existing ceilings to be removed. The wiring shall be capped and maintained for the reinstallation of such devices in the new ceiling.
RCP Demolition Notes
1. The Contractor shall coordinate all electrical and mechanical items that are incorporated into the millwork. Outlets, devices, switches and all other exposed electrical or mechanical items shall not be concealed by the millwork.
2. The Contractor shall provide upper and base cabinet fillers as required or as shown on the drawings. Required filler pieces shall be installed evenly to allow proper operation of drawers and doors.
3. On wall cabinets without a fascia above, the top surface shall be continuous to prevent inaccessible spaces from occurring.
4. The Contractor shall install back panels on all casework unless noted otherwise.
5. The Contractor shall refer to the casework elevations for the hinge swing direction on all single door upper and lower cabinets. Doors that open towards a wall, appliances, etc.
shall be provided with limit chains or door stops.
6. The Contractor shall coordinate the location of electrical punch throughs and grommets with the Architect and the Owner.
7. All semi exposed surfaces shall be covered with a laminate or finished wood surface to match the exposed sides unless noted otherwise. All non-exposed surfaces shall be covered with white melamine unless noted otherwise.
8. All cabinet pulls are noted in the casework specifications and/or finish plans.
9. The Contractor shall provide under counter support brackets as required for proper support of the countertops.
10. All backsplashes shall be 4" h. unless noted otherwise.
11. The Contractor shall verify all equipment sizes with the Owner and the Architect to ensure proper space is allotted. Coordinate the installation and space requirements for all Owner Furnished, Contractor Installed (OFCI) equipment.
12. The Contractor shall coordinate the installation of the casework and appliances to ascertain that there is adequate space provided for all the operable parts to function properly.
Casework Notes
1. The Contractor shall field verify all dimensions before fabrication of window frames. If there are any discrepancies, notify the Architect before proceeding with the Work.
2. The Contractor shall Install safety glazing throughout the project.
3. All exterior glazing shall be insulated, tempered and low ‘E’ glazing, unless noted otherwise.
4. In-Swing Hopper windows and shall have 9" limit stops incorporated.
Window Frame Notes
/2
" Project Number:
5400 Greenwood Plaza Blvd.
Greenwood Village, CO 80111
Phone: 720.200.0630
Consultants:
Project Title:
Sheet Title:
Drawn By:
Checked By:
/2
/2
:3 :1
P
M C
U s e rs \m ru b io \D o c u m e n ts
\2
T e llu ri d e W
W T
P A
C e n tr a l_
M R u b io e id o s a rc h .c o m
.r vt
23019
A0.1
General Notes
Telluride Wastewater
Treatment Plant
Town of Telluride
Telluride, Colorado
MLR
LMH
© 2025
Lab Upgrades
Mark Date Description
12-04-24 100% CDs
12-20-24 Permit Set
1 02-07-25 Response to Comments
S SS
1F 1F1F
DW
Building Information:
Building was built in 1987 and compliant with the codes used at that time.
Codes Used: 2018 IBC 2018 IPC
2018 IECC 2018 IFC
2023 NEC 2018 IFGC
2018 IMC 2009 ICC/ANSI A117.1
2018 IEBC 2018 IPMC
IECC 2018 - Climate Zone 6B
Occupancy Classification: B (existing, no proposed change)
Construction Type: Type II-B, non-sprinklered (existing, no proposed change)
Code Analysis Approach:
The existing building is being remodeled under the Work Area Method: Alteration - Level 2 of the 2018 IEBC, Chapter 8. No additional square footage is being added as part of the project.
Laboratory 540 SF <15% Total Area of Administrative Building: 3,720 SF
Light well / Mechanical chase does not need to be enclosed in a fire rated shaft because the roof/ceiling is not rated. However, the space around the duct needs to be fire sealed.
(716.6.3)
There is no combustible attic spaces in the addition, therefore no draftstopping required.
Code Analysis
Room & Area Number
Room & Area Name
Room & Area Occupancy
Net Room & Net Area As Required Per Code
Room & Area Use Group
Room Use Occupancy Load
Egress Component Capacity
Maximum Travel Distance From Furthest Point ( Use This Tag In Conjunction With The 'Egress Distance' Schedule For Totaling Of All Paths)
56'-0"
Smoke
1 - Hour Fire
FEC
FEW
Fire Extinguisher & Cabinet
Fire Extinguisher & Wall Mounting Bracket
Code Legend
Rm. No. Room Name
Factor Area Occ.
101 NAME
150 SF #OccTYPE
PATH
Occupant Load of Room Exit
Travel Path
Subtotal Occupant Load
X1
XSub
XXAct
XXMax
Actual Total Occupant Load at Exit
Maximum Total Required Occupant Load at Exit
Direction of Exit
FEW
Rm. No. Room Name
Factor Area Occ.
538 SF
209 Lab
4150G Rm. No. Room Name
Factor Area Occ.
149 SF
208 Electrical Room
1300G
Rm. No. Room Name
Factor Area Occ.
127 SF
205 Office
1150G
Rm. No. Room Name
Factor Area Occ.
376 SF
214 Control Room
3150G
Rm. No. Room Name
Factor Area Occ.
98 SF
214E Office
1150G
Rm. No. Room Name
Factor Area Occ.
101 SF
214D Office
1150G
Rm. No. Room Name
Factor Area Occ.
122 SF
214A Library Plan Rm
1150G
Rm. No. Room Name
Factor Area Occ.
53 SF
214B Elec./ Water
1300G
Rm. No. Room Name
Factor Area Occ.
54 SF
214C Laundry
1300G
Rm. No. Room Name
Factor Area Occ.
1483 SF
215 Headworks
6300G
Rm. No. Room Name
Factor Area Occ.
605 SF
228 Break Room
AREA OF WORK
LAB REMODEL
EXISTING
BUILDING TO
REMAIN
AREA OF WORK
NEW WINDOWS
& DOOR
N
AREA OF WORK
BAR SCREEN &
GRIT CHAMBER
REMOVED FROM
SCOPE OF WORK
/2
" Project Number:
5400 Greenwood Plaza Blvd.
Greenwood Village, CO 80111
Phone: 720.200.0630
Consultants:
Project Title:
Sheet Title:
Drawn By:
Checked By:
/2
/2
:3 :2
P
M C
U s e rs \m ru b io \D o c u m e n ts
\2
T e llu ri d e W
W T
P A
C e n tr a l_
M R u b io e id o s a rc h .c o m
.r vt
23019
A0.2
Code Plan, Analysis, & Legend
Telluride Wastewater
Treatment Plant
Town of Telluride
Telluride, Colorado
JJ/MLR
LMH
© 2025
1/8" = 1'-0"
Main Level Code Plan
1" = 40'-0"
Key Plan
N Phase 3 shown
Lab Upgrades
Mark Date Description
12-04-24 100% CDs
12-20-24 Permit Set
STATEMENT OF SPECIAL INSPECTIONS
This Statement of Special Inspections is submitted as a condition for permit issuance in accordance with the Special Inspection and Structural Testing requirements of the Building Code. It includes a schedule of Special Inspection services applicable to this project as well as the name of the Special Inspection Coordinator and the identity of other approved agencies to be retained for conducting these inspections and tests. This Statement of Special Inspections encompass the following disciplines: Structural
The Special Inspection Coordinator shall keep records of all inspections and shall furnish inspection reports to the Building Official and the Registered Design Professional in Responsible Charge. Discovered discrepancies shall be brought to the immediate attention of the Contractor for correction. If such discrepancies are not corrected, the discrepancies shall be brought to the attention of the Building Official and the Registered Design Professional in Responsible Charge. The Special Inspection program does not relieve the Contractor of his or her responsibilities.
The inspectors and testing agencies shall be engaged by the Owner or the Owner’s Agent, and not by the Contractor or Subcontractor whose work is to be inspected or tested. Any conflict of interest must be disclosed to the Building Official, prior to commencing work.
Reports shall be submitted to the Building Official and the Registered Design Professional in Responsible Charge.
Report Frequency: Within 48 hours of inspection, unless indicated otherwise.
A Final Report of Special Inspections documenting completion of all required Special Inspections, testing and correction of any discrepancies noted in the inspections shall be submitted prior to issuance of a Certificate of Use and Occupancy.
Job site safety and means and methods of construction are solely the responsibility of the Contractor.
The qualifications of all personnel performing Special Inspection and testing activities are subject to the approval of the Building Official. The credentials of all Inspectors and testing technicians shall be provided if requested.
Key for Minimum Qualifications of Inspection Agents:
When the Registered Design Professional in Responsible Charge deems it appropriate that the individual performing a stipulated test or inspection have a specific certification or license as indicated below, such designation shall appear below the Agency Number on the Schedule.
PE/SE Structural Engineer – a licensed SE or PE specializing in the design of building structures PE/GE Geotechnical Engineer – a licensed PE specializing in soil mechanics and foundations EIT Engineer-In-Training – a graduate engineer who has passed the Fundamentals of Engineering examination
American Concrete Institute (ACI) Certification ACI-CCI Concrete Construction Inspector
American Welding Society (AWS) Certification AWS-CWICertified Welding Inspector AWS/AISC-SSICertified Structural Steel Inspector
American Society of Non-Destructive Testing (ASNT) Certification ASNT Non-Destructive Testing Technician – Level II or III
International Code Council (ICC) Certification ICC-SWSI Structural Steel and Welding Special Inspector
Quality Assurance Plans
Quality Assurance for Seismic Resistance Seismic Design Category: C Quality Assurance Plan Required: No
Quality Assurance for Wind Requirements Basic Wind Speed Vasd (3 second gust): 85 mph Basic Wind Speed Vult (3 second gust): 110 mph Wind Exposure Category: B Quality Assurance Plan Required: No
Statement of Responsibility Each contractor responsible for the construction or fabrication of a system or component designated above must submit a Statement of Responsibility.
Prepared by:
EOR NAME / Signature Date
Owner's Authorization:
Signature Date
Building Official's Acceptance:
Signature Date
STEEL SPECIAL INSPECTION (2018 IBC 1705.2 & 1705.12.1)
ITEM
REQUIRED
QUALIFICATIONS FREQUENCY DETAILED INSTRUCTIONS
PERIODIC TEST
OR INSPECTION
FREQUENCY
STEEL INSPECTION NOTES AND
DEFINITIONS:
Observe The inspector shall observe these items on a random basis.
Operations need not be delayed pending these inspections.
Perform These tasks shall be performed for each item, instance, member, or connection unless noted otherwise
Document Document all inspection tasks as required by AISC 341-16
FABRICATORS (2018 IBC 1704.2.5 & 1705.10)
In-plant Inspection AWS/AISC-SSI
ICC-SWSI
Required unless Fabricator is approved and follows procedures of 1704.2.5.1
PRIOR TO WELDING (AISC 360-16, TABLE N5.4-1; AISC 341-16, TABLE J6.1)
Verify welding procedures (WPS) and consumable certificates
AWS-CWI ASNT Perform
Material identification AWS-CWI ASNT Observe Verify type and grade of material.
Welder identification AWS-CWI ASNT Observe A system shall be maintained by which a welder who has welded a joint or member can be identified.
Fit-up of fillet welds AWS-CWI ASNT Observe Verify alignment, gaps at root, cleanliness of steel surfaces, and tack weld quality and location.
DURING WELDING (AISC 360-16, TABLE N5.4-2; AISC 341-16, TABLE J6.2)
Use of qualified welders AWS-CWI ASNT Observe Verify that welders are appropriately qualified.
Control and handling of welding consumables
AWS-CWI ASNT Observe Verify packaging and exposure control.
Environmental conditions AWS-CWI ASNT Observe Verify wind speed is within limits as well as precipitation and temperature.
WPS followed AWS-CWI ASNT Observe Verify items such as settings on welding equipment, travel speed, welding materials, shielding gas type/flow rate, preheat applied, interpass temperature maintained, proper position, intermix of filler metals avoided unless approved.
Welding techniques AWS-CWI ASNT Observe Verify interpass and final cleaning, each pass is within profile limitations, and quality of each pass.
AFTER WELDING (AISC 360-16, TABLE N5.4-3; AISC 341-16, TABLE J6.3)
Welds cleaned AWS-CWI ASNT Observe Verify that welds have been properly cleaned.
Size, length, and location of welds AWS-CWI ASNT Perform
Welds meet visual acceptance criteria AWS-CWI ASNT Perform Verify crack prohibition, weld/base-metal fusion, crater cross section, weld profiles and size, undercut, and porosity.
Arc strikes AWS-CWI ASNT Perform k-area AWS-CWI ASNT Perform
Repair activities AWS-CWI ASNT Perform
Document acceptance or rejection of welded joint/member
AWS-CWI ASNT Perform
No prohibited welds have been added without the approval of the EOR
AWS-CWI ASNT Observe
OTHER STEEL INSPECTIONS (AISC 360-16, SECTION N5.8; AISC 341-16, Tables J8.1 & J10.1)
Structural steel details PE/SE Perform All fabricated steel or steel frames shall be inspected to verify compliance with the details shown in the construction documents, such as braces, stiffeners, member locations, and proper application of joint details at each connection.
Anchor rods and other embedments supporting structural steel
ACI-CCI Perform Shall be on the premises during the placement of anchor rods and other embedments supporting structural steel for compliance with construction documents. Verify the diameter, grade, type, and length of the anchor rod or embedded item, and the extent or depth of embedment prior to placement of concrete.
SCHEDULE OF INSPECTION AND TESTING AGENCIES
SPECIAL INSPECTION AGENCIES FIRM ADDRESS, TELEPHONE, E-MAIL
Special Inspection Coordinator TBD
Inspector TBD
Inspector TBD
Testing Agency TBD
Testing Agency TBD
Continuous TBD
Other TBD
/2
" Project Number:
5400 Greenwood Plaza Blvd.
Greenwood Village, CO 80111
Phone: 720.200.0630
Consultants:
Project Title:
Sheet Title:
Drawn By:
Checked By:
/7
/2
:1
:0
A
M C
U s e rs \k lb \D o c u m e n ts
\T e llu ri d e R
_k b e n to n jv a jv a .c o m
.r vt
21918
S0.1
IBC 2018
STATEMENT OF
SPECIAL
INSPECTION
Telluride Wastewater
Treatment Plant
Town of Telluride
Telluride, Colorado
KLB
AJT
Mark Date Description
12-20-24 PERMIT SET
02-07-25 RESPONSE TO
COMMENTS
02/07/2025
AREA OF WORK,
HEADWORKS DEMO AND
REPAIRS FOR NEW
EQUIPMENT
EXISTING
BUILDING TO
REMAIN
HEADWORKS
OFFICES
SLAB, SEE PLAN FOR
THICKNESS, SLAB REINF
NOT SHOWN
AS REQUIRED FOR
EQUIPMENT AND
PIPING, 5" MIN
ANCHOR BOLT
3/4" CHAMFER
#5@12" EW
ROUGHEN SURFACE, CLEAN, AND
APPLY BONDING COMPOUND
M
IN
1/
2" C
LR
ALL AROUND
3" MIN
G R
O U
T , I
F R
E Q
1" M
IN
N
O N
-S H
R
IN
K
LEVELING NUT
LOCK NUT
NOTES:
1. THE HEADWORKS AREA HAS VARIABLE SLAB THICKNESS AND DIFFERENT
REINFORCEMENT ACROSS THE GRADE LEVEL. DO NOT DAMAGE EXISTING SLAB
REINF.
A. FOR NEW EQUIPMENT PADS ON 6" EXISTING SLABS, DRILL INTO EXISTING SLAB
4" DEPTH AT 12" CENTERS AROUND PERIMETER OF EQUIPMENT BASE AND SET
#5 HOOKED DOWELS IN EPOXY GROUT. (4 DOWELS MIN)
B. FOR NEW EQUIPMENT PADS ON EXISTING COMPOSITE DECK SLABS, DRILL
INTO EXISTING SLAB 1 1/2" AT 6" CENTERS AROUND PERIMETER OF EQUIPMENT
BASE AND SET #5 HOOKED DOWELS IN EPOXY GROUT. (4 DOWELS MIN)
2. EQUIPMENT PAD DIMENSIONS SHALL BE AS REQUIRED BY THE EQUIPMENT MFR.
3. ANCHOR BOLTS AS RECOMMENDED BY THE EQUIPMENT MFR. BOLTS SHALL BE
HELD IN POSITION WITH A TEMPLATE WHILE EQUIPMENT BASE IS BEING CAST.
4. EQUIPMENT BASES SHALL BE INSTALLED LEVEL. TOLERANCE IS 1/16"
5. CONCRETE MIX DESIGN PROPERTIES: f'c = 4,000 PSI @ 28 DAYS, 0.45 W/CM RATIO, 3/4" STONE MAX AGGREGATE, ENTRAPPED AIR ONLY.
6. IF REQUIRED, NON-SHRINK GROUT PROPERTIES: f'c = 4,000 PSI @ 1 DAY, f'c=5,000
PSI @ 7 DAYS
#5 CLOSED
TIES @ 6"
EQUIPMENT BASE
REMOVAL
DEMO EXISTING
CONCRETE EQUIPMENT
PADS AS SHOWN ON PLAN
CLEAN EXPOSED CONCRETE
SURFACES OF DEBRIS
REMOVE CONCRETE AT
EQUIPMENT PADS
BETWEEN 1/4" AND 1/2"
INTO EXISTING SLAB. DO
NOT CUT OR DAMAGE
HORIZONTAL SLAB
REINFORCEMENT
RESTORATION
APPLY BONDING COMPOUND
TO CONCRETE SURFACES
SIKA EZ PATCH MORTAR, OR
EQUAL, FINISHED TO MATCH
ADJACENT SURFACE
S1.0 ________ 1
S1.0
SAWCUT AND REMOVE 6"
SLAB AND/OR EXISTING
GRATING OVER THE
CHANNEL TO EXTEND
OPENING FOR SCREEN
3'
4'
-0
1'
-6
NOTES:
1. ALL DIMENSIONS TO BE FIELD VERIFIED.
A. FOR BIDDING PURPOSES, ASSUMED EQUIPMENT PAD HEIGHTS ARE VARIABLE BETWEEN 6"
AND 2'-0"
2. VERIFY LENGTH OF SAWCUT OVER CHANNEL PER NEW SCREEN MFR REQUIREMENTS.
3. DO NOT OVER CUT NEW OPENINGS IN EXISTING SLAB.
4. CONTRACTOR TO VERIFY THE EQUIPMENT ANCHOR BOLTS ARE COMPATIBLE WITH THE
GIVEN SUBSTRATE.
5. UNLESS NOTED OTHERWISE, EXISTING CONC SLAB IS 6" IN THICKNESS. EXISTING
REINFORCEMENT IS VARIABLE DEPENDING ON LOCATION.
A B
DEMOLISH EQUIPMENT PADS
FOR THE SLUDGE
THICKENERS AND FLOC
TANKS. FINISH SURFACE PER
DETAIL
ASSUME FOR BIDDING
PURPOSE 1'-8" TALL PADS
DEMOLISH EQUIPMENT
PADS FOR THE SLUDGE
THICKENERS AND FLOC
TANKS. FINISH SURFACE
PER DETAIL
ASSUME FOR BIDDING
PURPOSE 1'-8" TALL PADS
3/S1.0
3/S1.0
DEMO EQUIPMENT PADS FOR THE
GRIT CLASSIFIER. FINISH SURFACE
PER DETAIL . ASSUME FOR
BIDDING PURPOSE 1'-0" TALL PADS
3/S1.0
EXISTING COMPOSITE STEEL DECK:
2" CONC W/ WWF 6x6 - W4xW4 ON 2"
METAL DECK
O P
E N
IN
G
L E
N G
T H
9'
EXISTING OPENING FOR EXISTING
SCREEN
DEMOLISH EQUIPMENT
PADS FOR THE SCREEN.
FINISH SURFACE PER
DETAIL , TYP (2),
ASSUME FOR BIDDING
PURPOSE 6" TALL PADS
3/S1.0
EXISTING 1" GRATING
SUPPORTED BY ALUM
SUPPORT MEMBERS
EVALUATE GRATING CONDITION
UNDER THE REMOVED FEEDER
SYSTEM. LOCALIZED REPLACEMENT
GRATING PANEL MAY BE REQUIRED.
MATCH EXISTING GRATING. ASSUME
FOR BIDDING PURPOSES THAT 14 SF
OF GRATING WILL NEED TO BE
REPLACED WITH 1" GALV STEEL
GRATING
4' - 0 1/2"
CORE 6" Ø PENETRATION
VERIFY LOCATION PER
EQUIPMENT MFR. DO NOT
DAMAGE EXISTING BEAM
BELOW.
EXISTING HATCH OPENING
EXISTING PIPE PENETRATION NOT
USED, ROUGHEN EDGES AND FILL
WITH SIKACRETE-211 OR EQUAL.
EXISTING PENETRATION TO
BE REUSED
1' - 6" 4"
1' - 10"
REMOVE DUCT THRU SLAB AND
PATCH PER OR ALT
DETAIL . DEMOLISH
SURROUNDING CURB AND PATCH
PER .3/S1.0
5/S1.1 6/S1.1
#4 @ 12" EW
T O
P
1/ 2"
C
LR
SAWCUT THRU REBAR IN CONC
SLAB AT OPENING PER PLAN AND
COAT EXPOSED BARS W/ TNEMEC
SERIES 435 @ 30 MILS OR EQUAL
2" 2"
6"
INFLUENT CHANNELBYPASS CHANNEL
1 1/2" SERRATED TOP ALUMINUM
GRATING, MATCH FINISHED FLOOR
ELEVATION
ALUMINUM L3x2x1/4 LLV W/ 1/2" Ø SS
ANCHORS @ 18" MAX SPACING AND
EACH END
INFLUENT CHANNELBYPASS CHANNEL
NOTE: CONTRACTOR TO VERIFY THE DEPTH OF
CHANNEL AT THE FOOT OF THE SCREEN IS 8'-9 1/2"
PER MFR REQUIREMENT.
S1.0 ________ 2
S1.0
INSTALL NEW 1 1/2"
ALUMINUM GRATING
OVER CHANNEL,
COORD W/ MFR FOR
OPENING SIZE FOR
SCREEN. VERIFY
GRATING SIZE PER
FIELD MEASURED
CONDITIONS
3'
4'
-0
1-
6"
NOTES:
1. FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF GRATING
2. ALL NEW EQUIPMENT IS NOT SHOWN. REFER TO MFR DWGS.
A B
NEW ANCHORS AND
GRATING CLIPS TO
GRATING ON A
NEOPRENE RUBBER
VIBRATION PAD AS
REQUIRED BY MFR FOR
FEEDER
9'
1' - 0"2' - 7"
1' - 0" 1' - 4"
8" 5'
4'
2' - 9" 1' - 9"
3"
NEW 5" TALL EQUIPMENT
PADS FOR GRIT CLASSIFIER,
VERIFY DIMENSIONS AND
LOCATIONS WITH MFR, SEE
DETAIL , TYP (3)4/S1.0
3"
A B
S1.0
S1.0
1/
2"
2' - 6"
DEMO AREA
MIN 1/4" SURFACE
AMPLITUDE AFTER
DEMO
2' - 6"
.0
SIKACRETE 211, OR EQUAL, TO PROVIDE
10° SLOPED SURFACE, ALIGN TOP OF
GROUT WITH ELEVATION OF THE
INFLUENT CHANNEL
1" M
IN
/2
" Project Number:
5400 Greenwood Plaza Blvd.
Greenwood Village, CO 80111
Phone: 720.200.0630
Consultants:
Project Title:
Sheet Title:
Drawn By:
Checked By:
/6
/2
:2
:1 P
M C
U s e rs \k lb \D o c u m e n ts
\T e llu ri d e R
_k b e n to n jv a jv a .c o m
.r vt
21918
S1.0
HEADWORKS
DEMOLITION AND
FLOOR PLAN
Telluride Wastewater
Treatment Plant
Town of Telluride
Telluride, Colorado
KLB
AJT
NORTH
1" = 40'-0"
KEYPLAN0 2' 4' 32'8' 16'
3/4" = 1'-0"S1.0
EQUIPMENT PAD DETAIL4
0 2' 4' 32'8' 16'
3" = 1'-0"S1.0
CONCRETE SLAB RESTORATION3
0 2' 4' 8' 16'
NORTH
1/8"1/8" = 1'-0"
HEADWORKS DEMO GRADE PLAN
1' 2' 4'0 8'
1/4" = 1'-0"S1.0
CHANNEL DEMO1
1' 2' 4'0 8'
1/4" = 1'-0"S1.0
CHANNEL REPAIR2
NORTH
1/8" = 1'-0"
HEADWORKS NEW GRADE PLAN
NORTH
1/8" = 1'-0"
LOWER LEVEL GRIT PLAN
1' 2' 4'0 8'
1/2" = 1'-0"S1.0
GRIT CHAMBER DEMO5
0 2' 4' 32'8' 16'
1/2" = 1'-0"S1.0
GRIT CHAMBER REPAIR6
Mark Date Description
12-20-24 PERMIT SET
02-07-25 RESPONSE TO
COMMENTS
02/06/2025
SCOPE
REMOVED
FROM
PROJECT
AREA OF WORK,
NEW WINDOWS IN
EXTERIOR WALL
EXISTING
BUILDING TO
REMAINHEADWORKS
OFFICES
STONE SILL, RE: ARCH
INTERIOR EXTERIOR
4" CMU VENEER
4" CMU VENEER
(2) - L7x4x3/8 (LLH) x OPENING WIDTH + 4" BEARING
EACH SIDE, VERT LEGS TIGHT TO FACE OF WALL.
COATING PER ARCH. DO NOT CUT MASONRY
REINFORCEMENT, COPE ANGLES AS REQUIRED WHERE
ANGLE INTERFERES WITH REINFORCEMENT
WINDOW FRAME, RE: ARCH
GLAZING, RE: ARCH
8" CMU
1 1/2" INSULATION
NOTE:
1. FIELD VERIFY, ASSUMED THICKNESS OF WALL SECTION PER COMPONENTS AS
NOTED ABOVE. NOTIFY ENGINEER OF RECORD IF DISCREPANCIES EXIST.
1/2" AIR VOID
3/16 2-12
1/4" COVER PL TO
ANGLE
8" STRUCTURAL CMU
INTERIOR
EXTERIOR
GLAZING & FRAME,
RE: ARCH
STONE SILL BELOW,
RE: ARCH
3/8" BENT PLATE, FULL HEIGHT OF OPENING
AND FULL WIDTH OF WALL SECTION, WRAP 2"
AROUND INTERIOR BLOCK TIGHT TO FACE OF
WALL.
DO NOT DAMAGE REINF IN
GROUTED CELLS AT JAMBS
NOTE:
1. FIELD VERIFY THICKNESS OF WALL SECTION FOR PROCUREMENT
OF BENT PLATE
8" STRUCT CMU BLOCK
4" CMU VENEERSTONE SILL BELOW,
RE: ARCH
3/8" Ø TITEN HD COUNTERSUNK HEAD ANCHOR
W/ 2 3/8" EMBED INTO GROUTED OR HOLLOW
CELLS @ 16" MAX SPACING. 3 13/16" MIN EDGE
DIST, 1 3/4" MIN DIST TO BED JOINT.
REMOVE (E) CMU
FOR (N) WINDOW
4"
EXISTING WINDOWS TO REMAIN
4"
REMOVE (E) CMU FOR (N)
SILL BLOCK, RE: ARCH
2'
8" 3'
1'
1'
1'
3' - 4"
2/S1.1
2/S1.1
DO NOT CUT MASONRY
REINFORCEMENT, COPE
ANGLES AS REQUIRED
WHERE ANGLE
INTERFERES WITH
REINFORCEMENT
ANTICIPATED LOCATION/SPACING OF
REINFORCED GROUTED CELLS,
CONTRACTOR TO CONFIRM GROUTED
CELL EXISTS BETWEEN PROPOSED
WINDOW LOCATIONS, CONTACT
ENGINEER OF RECORD OTHERWISE
3/S1.13/S1.1
REMOVE (E) CMU
FOR (N) WINDOW
REMOVE (E) CMU FOR (N)
SILL BLOCK, RE: ARCH
10' - 0"
NOTES:
1. ASSUMED #4 @ 32" REBAR SPACING.
2. ASSUMED JAMB DESIGN FOR THE 10'-0" WINDOW ABOVE IS SUFFICENT FOR ADDITION
OF OPENINGS BELOW.
A. CONTRACTOR TO IDENTIFY GROUTED CELLS AT JAMB TO VERIFY.
3. INSTALLATION STEPS:
A. SAWCUT BED JOINT FOR ANGLES
B. INSTALL ANGLES AND WELD TOGEHER WITH CLOSURE PLATE.
C. DEMO AND REMOVE CMU BLOCK BELOW ANGLES AS SHOWN. DO NOT OVERCUT.
0"
ALIGN NEW WINDOWS WITH EXISTING WINDOW ABOVE
EXISTING OPENING
SUPPORT FRAME (IF EXISTS)
EXTEND DECK TO NEAREST
ROOF BEAM/JOIST IF FRAME
IS NOT PRESENT
DEMO SKYLIGHT & REPLACE WITH
INSULATION AND ROOF
MEMBRANE EQUIVALENT AND
COMPATIBLE WITH EXISTING
ROOFING MATERIALS
EXTENT OF NEW DECK
PENETRATION
EXISTING ROOF
1 1/2" MIN BEARING, TYP
NOTES:
1. FOR LOCATION OF SKYLIGHTS TO BE INFILLED, RE: ARCH.
2. FIELD VERIFY EXISTING DECK IS 1 1/2"x 22 GA ROOF DECK.
3. FILL OPENING WITH NEW DECK MATCHING EXISTING, FASTEN TO EXISTING
DECK ALONG PERIMETER WITH #10 SDST SCREWS @ 6"
4. INSTALL EQUIVALENT AND COMPATIBLE INSULATION AND ROOFING
MATERIALS ABOVE DECKING, UNLESS NOTED OTHERWISE.
INFILL WITH
SIKACRETE-211 OR
EQUAL AT EXISTING
DUCT OPENING
MIN
6" EXISTING OPENING
MIN
6"
NOTES:
1. FIELD VERIFY EXISTING DECK SIZE AND GAUGE. MATCH NEW DECK WITH
EXISTING.
2. COVER OPENING FROM UNDERSIDE OF OPENING AND LAP 6" MINIMUM WITH
NEW DECK. FASTEN TO EXISTING DECK ALONG PERIMETER WITH TAPCON
3/16"Øx2 1/4" TAPCON STAINLESS SCREW @ 12" MAX SPACING AT
PERIMETER FROM BOTTOM OF DECK FLUTES.
EXTENT OF NEW DECK
LAP NEW 2"
COMPOSITE DECK
WITH EXISTING
L3x2x3/16 (LLH) CONT
NEW SLAB ON 2" DECK, TOTAL SLAB
THICKNESS INCLUDING DECK FLUTES = 4".
CONT L6x4x5/16 (LLH) AT 4 SIDES OF
INFILL, ATTACH TO EXISTING CONCRETE
SLAB W/ 3/16"Øx2 1/4" TAPCON STAINLESS
SCREW @ 12"
EXISTING CONCRETE SLAB
ON DECKING
3/16 2-12
TYP
SHORTEST DIMENSION
2' - 0" MAX IN
3"
0 2' 4' 32'8' 16'
1 1/2" = 1'-0"S1.1
WINDOW HEAD AND SILL2
0 2' 4' 32'8' 16'
1 1/2" = 1'-0"S1.1
WINDOW JAMB3
/2
" Project Number:
5400 Greenwood Plaza Blvd.
Greenwood Village, CO 80111
Phone: 720.200.0630
Consultants:
Project Title:
Sheet Title:
Drawn By:
Checked By:
/6
/2
:2
:2 P
M C
U s e rs \k lb \D o c u m e n ts
\T e llu ri d e R
_k b e n to n jv a jv a .c o m
.r vt
21918
S1.1
OFFICE WINDOWS
ADDITION
Telluride Wastewater
Treatment Plant
Town of Telluride
Telluride, Colorado
KLB
AJT
NORTH
1" = 40'-0"
KEYPLAN
0 2' 4' 32'8' 16'
3/4" = 1'-0"S1.1
ELEVATION OF NEW WINDOW OPENINGS1
NO SCALES1.1
TYP ROOF DECK REPAIR4
Mark Date Description
12-20-24 PERMIT SET
02-07-25 RESPONSE TO
COMMENTS
3/4" = 1'-0"S1.1
COMPOSITE DECK REPAIR5
3/4" = 1'-0"S1.1
ALT COMPOSITE DECK REPAIR6
02/06/2025
D W
D W
DW
D W
DW
AREA OF WORK
LAB REMODEL
EXISTING
BUILDING TO
REMAIN
AREA OF WORK
NEW WINDOWS
& DOOR
N
AREA OF WORK
BAR SCREEN &
GRIT CHAMBER
REMOVED FROM
SCOPE OF WORK
D.2
Storage
390 SF
Lab
D.1
212A
Shower 212C
Toilet
Janitor
Bathroom &
Shower 214D
Hall
Hall 207Headworks
D.3 D.5
D.4
PHASE 2
AREA OF WORK
PHASE 3
AREA OF WORK
D.18
1.1
1.2
Janitor
Shower 212C
212A Toilet
Storage
390 SF
Lab
Hall
Hall
1.4 1.5
1.6
PHASE 2
AREA OF WORK
PHASE 3
AREA OF WORK
1.10 1.12
Bathroom &
Shower 214D
Headworks
1.9
A5.0 31
12' - 10" V.I.F.
V .I .F
9' - 10" 3' - 0"
1.19
L E N
G T H
6' LENGTH
1.8
1.22
"1.23
1.25
Existing Construction To Be Removed
Existing Construction To Remain
Shaded Area Not In Contract
Phase 2 Area of Work
Phase 3 Area of Work
Demolition Legend
Office 214E
Office 214F
A5.0
01 01 1.161.16
3' - 4" 3' - 4" 3' - 4"
10' - 0"
Vestibule
A5.0
Office 214E
Office 214F
D.17 D.17
ALIGN TO (E) WINDOW
4' - 8" V.I.F. 3' - 4" 3' - 4" 3' - 4"
D.24
10' - 10" V.I.F.
Vestibule
Library Plan Rm 214A
Elec./ Water 214B
Laundry 214C
Janitor
Shower 212C
212A Toilet
Storage
Lab
Office 214E
Office 214F
Hall
Hall
Hall 214H
PHASE 2
AREA OF WORK
PHASE 3
AREA OF WORK
Bathroom &
Shower 214D
Headworks
1.17
Control Room
RE: S1.0 FOR
SCOPE OF
WORK IN
HEADWORKS
/2
" Project Number:
5400 Greenwood Plaza Blvd.
Greenwood Village, CO 80111
Phone: 720.200.0630
Consultants:
Project Title:
Sheet Title:
Drawn By:
Checked By:
/2
/2
:5 :5
P
M C
U s e rs \m ru b io \D o c u m e n ts
\2
T e llu ri d e W
W T
P A
C e n tr a l_
M R u b io e id o s a rc h .c o m
.r vt
23019
A1.0
Demolition Floor Plan & Floor Plan - Phase 1
Telluride Wastewater
Treatment Plant
Town of Telluride
Telluride, Colorado
JJ
LMH
© 2025
1" = 40'-0"
Key Plan
1/4" = 1'-0"
Main Level Demolition Plan - Phase 1
1/4" = 1'-0"
Main Level Floor Plan - Phase 1
Keynote Legend - Demo Plans
D7.1 REMOVE (E) MECH. DIFFUSERS - RE: HVAC
D7.2 REMOVE (E) CEILING TILE & GRID
D7.3 REMOVE (E) LIGHTS FOR RELOCATION - RE: ELEC.
D7.4 REMOVE (E) WALL
D7.5 REMOVE (E) HOOD VENT DUCTWORK THROUGH TO ROOF
D7.6 REMOVE (E) SKYLIGHTS
D.1 REMOVE (E) SHELVING
D.2 RELOCATE (E) 30" X 30" REFRIGERATOR
D.3 REMOVE (E) FREEZER, RETURN TO OWNER
D.4 RELOCATE (E) ICE MAKER
D.5 REMOVE (E) LOCKER, RETURN TO OWNER
D.6 REMOVE (E) P-LAM. COUNTERTOP
D.7 RELOCATE (E) LAB WASHER
D.8 RELOCATE (E) UNDERCOUNTER REFRIGERATOR
D.9
REMOVE (E) SINK (LIMITED ASBESTOS COATING ON SINK - TO BE DISPOSED
OF PROPERLY)
D.10 REMOVE (E) BASE CABINETS, TYP.
D.11 REMOVE (E) EYEWASH AND SHOWER, RE: PLUMB.
D.13 RELOCATE (E) EQUIPMENT - BY OWNER
D.14 REMOVE (E) DOOR & FRAME
D.16 REMOVE (E) FUME HOOD
D.17
REMOVE PORTION OF (E) EXT. MASONRY WALL FOR NEW WINDOW OPENINGS -
RE: DETAILS FOR STRUCTURAL LINTEL SUPPORT
D.18 REMOVE (E) CABINET HEATER - RE: HVAC
D.19 REMOVE (E) ELECTRICAL PANEL - PHASE 2
D.20 REMOVE (E) UPPER CABINET/SHELVES
D.21 REMOVE (E) LABORATORY DRYING RACK
D.22 REMOVE (E) VCT FLOORING & RUBBER BASE
D.23 REMOVE (E) METAL FRAMED WALL
D.24 REMOVE (E) DOOR. (E) CURTAIN WALL FRAME TO REMAIN
1/4" = 1'-0"
Main Floor Level Plan - Phase 1 Windows and Door
1/4" = 1'-0"
Main Level Demolition Plan - Phase 1 Windows and Door
N
N
N
N
1/8" = 1'-0"
Headworks Scope of Work Floor Plan N
Keynote Legend - Floor Plans
1.1 RELOCATED ICE MAKER UNDER COUNTERTOP
1.2 (N) BUILT-IN 30" D. EPOXY COUNTERTOP & BASE CABS.
1.3 RELOCATED WORKSTATIONS ON (N) 30" D. MOBILE LAB TABLES
1.4 NEW SINK
1.5 NEW EMERGENCY EYEWASH & SHOWER
1.6 RELOCATED 30" X 30" REFRIGERATOR
1.7 (N) 48" FUME HOOD WITH ACID BASE CABINET, RE: MECH.
1.8 (N) 30" D. MOBILE LAB TABLES W/ ATTACHED SHELVING
1.9 (N) 30" x 30" UNDERCOUNTER REFRIGERATOR
1.10 RELOCATED UNDERCOUNTER LAB WASHER
1.11 (N) 30" D. MOBILE LAB TABLES
1.12 (N) 12" D. OPEN METAL SHELVING
1.13 (N) EXHAUST SNORKEL ABOVE FOR MUFFLE FURNACE/OVENS, RE: MECH.
1.14 (N) RUBBER TILE FLOORING -NORA NORAMENT XP & RUBBER BASE
1.15 RELOCATED BALANCE TABLE
1.16 (N) DARK BRONZE ANOD. ALUM. WINDOW, OPERABLE
1.17 PRIMARY BAR SCREEN - RE: STRUCT. FOR EQUIP. SUPPORTS
1.18 NEW ELECTRICAL PANEL - PHASE 2
1.19 NEW LABORATORY DRYING RACK
1.20 3 OVENS WITH HEAT EXHAUST
1.21 CANOPY HOOD - RE: MECH. FOR EXHAUST FAN
1.22 FLOOR DRAIN - RE: PLUMBING
1.23 FRP - 8' H.
1.24 STAINLESS STEEL CORNER GUARDS - 4' H.
1.25 RELOCATE (E) DI WATER GENERATION SYSTEM
Lab Upgrades
Mark Date Description
12-04-24 100% CDs
12-20-24 Permit Set
1 02-07-25 Response to
DW
W
DW
144 SF
Storage Lab
Lab
PHASE 3
AREA OF WORK
1.8
1.7
1.13
212A
Shower 212C
Toilet
Janitor
Bathroom &
Shower 214D
Hall
Hall
Headworks
PHASE 1
AREA OF WORK
A5.0
4' - 0" 5' - 4" 12' - 8" 1' - 0" 19' - 0" V.I.F.
1.18
8' LENGTH
8' LENGTH
LE
N G
T H
6' LENGTH
LE
N G
T H
1.20
1.21
1.11 1.8
AREA OF WORK
LAB REMODEL
EXISTING
BUILDING TO
REMAIN
AREA OF WORK
NEW WINDOWS
& DOOR
N
AREA OF WORK
BAR SCREEN &
GRIT CHAMBER
REMOVED FROM
SCOPE OF WORK
D.6
D.7
D.8
D.9
D.10
D.10
D.13
Lab
Storage Lab
212A
Toilet
Shower 212C
Bathroom &
Shower 214D
Janitor
Hall
Hall 207Headworks
D.13
D.16
D.11
PHASE 3
AREA OF WORK
PHASE 1
AREA OF WORK
D.6
D.6
D.13
D.20
D.20
D.21
D.19
Existing Construction To Be Removed
Existing Construction To Remain
Shaded Area Not In Contract
Phase 2 Area of Work
Phase 3 Area of Work
Demolition Legend
/2
" Project Number:
5400 Greenwood Plaza Blvd.
Greenwood Village, CO 80111
Phone: 720.200.0630
Consultants:
Project Title:
Sheet Title:
Drawn By:
Checked By:
/2
/2
:3 :2
P
M C
U s e rs \m ru b io \D o c u m e n ts
\2
T e llu ri d e W
W T
P A
C e n tr a l_
M R u b io e id o s a rc h .c o m
.r vt
23019
A2.0
Demolition Floor Plan & Floor Plan - Phase 2
Telluride Wastewater
Treatment Plant
Town of Telluride
Telluride, Colorado
JJ
LMH
© 2025
1/4" = 1'-0"
Main Level Floor Plan - Phase 2
1" = 40'-0"
Key Plan
1/4" = 1'-0"
Main Level Demolition Plan - Phase 2 N
N
Keynote Legend - Demo Plans
D7.1 REMOVE (E) MECH. DIFFUSERS - RE: HVAC
D7.2 REMOVE (E) CEILING TILE & GRID
D7.3 REMOVE (E) LIGHTS FOR RELOCATION - RE: ELEC.
D7.4 REMOVE (E) WALL
D7.5 REMOVE (E) HOOD VENT DUCTWORK THROUGH TO ROOF
D7.6 REMOVE (E) SKYLIGHTS
D.1 REMOVE (E) SHELVING
D.2 RELOCATE (E) 30" X 30" REFRIGERATOR
D.3 REMOVE (E) FREEZER, RETURN TO OWNER
D.4 RELOCATE (E) ICE MAKER
D.5 REMOVE (E) LOCKER, RETURN TO OWNER
D.6 REMOVE (E) P-LAM. COUNTERTOP
D.7 RELOCATE (E) LAB WASHER
D.8 RELOCATE (E) UNDERCOUNTER REFRIGERATOR
D.9
REMOVE (E) SINK (LIMITED ASBESTOS COATING ON SINK - TO BE DISPOSED
OF PROPERLY)
D.10 REMOVE (E) BASE CABINETS, TYP.
D.11 REMOVE (E) EYEWASH AND SHOWER, RE: PLUMB.
D.13 RELOCATE (E) EQUIPMENT - BY OWNER
D.14 REMOVE (E) DOOR & FRAME
D.16 REMOVE (E) FUME HOOD
D.17
REMOVE PORTION OF (E) EXT. MASONRY WALL FOR NEW WINDOW OPENINGS -
RE: DETAILS FOR STRUCTURAL LINTEL SUPPORT
D.18 REMOVE (E) CABINET HEATER - RE: HVAC
D.19 REMOVE (E) ELECTRICAL PANEL - PHASE 2
D.20 REMOVE (E) UPPER CABINET/SHELVES
D.21 REMOVE (E) LABORATORY DRYING RACK
D.22 REMOVE (E) VCT FLOORING & RUBBER BASE
D.23 REMOVE (E) METAL FRAMED WALL
D.24 REMOVE (E) DOOR. (E) CURTAIN WALL FRAME TO REMAIN
Keynote Legend - Floor Plans
1.1 RELOCATED ICE MAKER UNDER COUNTERTOP
1.2 (N) BUILT-IN 30" D. EPOXY COUNTERTOP & BASE CABS.
1.3 RELOCATED WORKSTATIONS ON (N) 30" D. MOBILE LAB TABLES
1.4 NEW SINK
1.5 NEW EMERGENCY EYEWASH & SHOWER
1.6 RELOCATED 30" X 30" REFRIGERATOR
1.7 (N) 48" FUME HOOD WITH ACID BASE CABINET, RE: MECH.
1.8 (N) 30" D. MOBILE LAB TABLES W/ ATTACHED SHELVING
1.9 (N) 30" x 30" UNDERCOUNTER REFRIGERATOR
1.10 RELOCATED UNDERCOUNTER LAB WASHER
1.11 (N) 30" D. MOBILE LAB TABLES
1.12 (N) 12" D. OPEN METAL SHELVING
1.13 (N) EXHAUST SNORKEL ABOVE FOR MUFFLE FURNACE/OVENS, RE: MECH.
1.14 (N) RUBBER TILE FLOORING -NORA NORAMENT XP & RUBBER BASE
1.15 RELOCATED BALANCE TABLE
1.16 (N) DARK BRONZE ANOD. ALUM. WINDOW, OPERABLE
1.17 PRIMARY BAR SCREEN - RE: STRUCT. FOR EQUIP. SUPPORTS
1.18 NEW ELECTRICAL PANEL - PHASE 2
1.19 NEW LABORATORY DRYING RACK
1.20 3 OVENS WITH HEAT EXHAUST
1.21 CANOPY HOOD - RE: MECH. FOR EXHAUST FAN
1.22 FLOOR DRAIN - RE: PLUMBING
1.23 FRP - 8' H.
1.24 STAINLESS STEEL CORNER GUARDS - 4' H.
Lab Upgrades
Mark Date Description
12-04-24 100% CDs
12-20-24 Permit Set
Lab
212A
Shower 212C
Bathroom &
Shower 214D
Janitor
Toilet
Hall
Hall
Headworks
1.14
1.15
A5.0
1.31.6
1.18
8' LENGTH
1.8
1.24
BC
BC
BC
BC
B
B
C
C
AA
AREA OF WORK
LAB REMODEL
EXISTING
BUILDING TO
REMAIN
AREA OF WORK
NEW WINDOWS
& DOOR
N
AREA OF WORK
BAR SCREEN &
GRIT CHAMBER
REMOVED FROM
SCOPE OF WORK
D.14
D.6
D.10
212A
Shower 212C
Toilet
Janitor
Bathroom &
Shower 214D
Hall
Hall
Headworks
Lab
D.23
D.22
D.22
D.20
D.20
Existing Construction To Be Removed
Existing Construction To Remain
Shaded Area Not In Contract
Phase 2 Area of Work
Phase 3 Area of Work
Demolition Legend
A
MOBILE CASEWORK SCHEDULE
SYMBOL QUANTITY WIDTH DEPTH HEIGHT CONFIGURATION
B
C
2 18" 24" 28" 3 DRAWER
6 24" 24" 34" 1DRAWER, 1 DOOR
6 24" 24" 34" 4 DRAWER
/2
" Project Number:
5400 Greenwood Plaza Blvd.
Greenwood Village, CO 80111
Phone: 720.200.0630
Consultants:
Project Title:
Sheet Title:
Drawn By:
Checked By:
/2
/2
:3 :2
P
M C
U s e rs \m ru b io \D o c u m e n ts
\2
T e llu ri d e W
W T
P A
C e n tr a l_
M R u b io e id o s a rc h .c o m
.r vt
23019
A3.0
Demolition Floor Plan & Floor Plan - Phase 3
Telluride Wastewater
Treatment Plant
Town of Telluride
Telluride, Colorado
JJ
LMH
© 2025
1/4" = 1'-0"
Main Level Floor Plan - Phase 3
1" = 40'-0"
Key Plan
1/4" = 1'-0"
1. Main Level Demolition Plan - Phase 3 N
N
Keynote Legend - Demo Plans
D7.1 REMOVE (E) MECH. DIFFUSERS - RE: HVAC
D7.2 REMOVE (E) CEILING TILE & GRID
D7.3 REMOVE (E) LIGHTS FOR RELOCATION - RE: ELEC.
D7.4 REMOVE (E) WALL
D7.5 REMOVE (E) HOOD VENT DUCTWORK THROUGH TO ROOF
D7.6 REMOVE (E) SKYLIGHTS
D.1 REMOVE (E) SHELVING
D.2 RELOCATE (E) 30" X 30" REFRIGERATOR
D.3 REMOVE (E) FREEZER, RETURN TO OWNER
D.4 RELOCATE (E) ICE MAKER
D.5 REMOVE (E) LOCKER, RETURN TO OWNER
D.6 REMOVE (E) P-LAM. COUNTERTOP
D.7 RELOCATE (E) LAB WASHER
D.8 RELOCATE (E) UNDERCOUNTER REFRIGERATOR
D.9
REMOVE (E) SINK (LIMITED ASBESTOS COATING ON SINK - TO BE DISPOSED
OF PROPERLY)
D.10 REMOVE (E) BASE CABINETS, TYP.
D.11 REMOVE (E) EYEWASH AND SHOWER, RE: PLUMB.
D.13 RELOCATE (E) EQUIPMENT - BY OWNER
D.14 REMOVE (E) DOOR & FRAME
D.16 REMOVE (E) FUME HOOD
D.17
REMOVE PORTION OF (E) EXT. MASONRY WALL FOR NEW WINDOW OPENINGS -
RE: DETAILS FOR STRUCTURAL LINTEL SUPPORT
D.18 REMOVE (E) CABINET HEATER - RE: HVAC
D.19 REMOVE (E) ELECTRICAL PANEL - PHASE 2
D.20 REMOVE (E) UPPER CABINET/SHELVES
D.21 REMOVE (E) LABORATORY DRYING RACK
D.22 REMOVE (E) VCT FLOORING & RUBBER BASE
D.23 REMOVE (E) METAL FRAMED WALL
D.24 REMOVE (E) DOOR. (E) CURTAIN WALL FRAME TO REMAIN
Keynote Legend - Floor Plans
1.1 RELOCATED ICE MAKER UNDER COUNTERTOP
1.2 (N) BUILT-IN 30" D. EPOXY COUNTERTOP & BASE CABS.
1.3 RELOCATED WORKSTATIONS ON (N) 30" D. MOBILE LAB TABLES
1.4 NEW SINK
1.5 NEW EMERGENCY EYEWASH & SHOWER
1.6 RELOCATED 30" X 30" REFRIGERATOR
1.7 (N) 48" FUME HOOD WITH ACID BASE CABINET, RE: MECH.
1.8 (N) 30" D. MOBILE LAB TABLES W/ ATTACHED SHELVING
1.9 (N) 30" x 30" UNDERCOUNTER REFRIGERATOR
1.10 RELOCATED UNDERCOUNTER LAB WASHER
1.11 (N) 30" D. MOBILE LAB TABLES
1.12 (N) 12" D. OPEN METAL SHELVING
1.13 (N) EXHAUST SNORKEL ABOVE FOR MUFFLE FURNACE/OVENS, RE: MECH.
1.14 (N) RUBBER TILE FLOORING -NORA NORAMENT XP & RUBBER BASE
1.15 RELOCATED BALANCE TABLE
1.16 (N) DARK BRONZE ANOD. ALUM. WINDOW, OPERABLE
1.17 PRIMARY BAR SCREEN - RE: STRUCT. FOR EQUIP. SUPPORTS
1.18 NEW ELECTRICAL PANEL - PHASE 2
1.19 NEW LABORATORY DRYING RACK
1.20 3 OVENS WITH HEAT EXHAUST
1.21 CANOPY HOOD - RE: MECH. FOR EXHAUST FAN
1.22 FLOOR DRAIN - RE: PLUMBING
1.23 FRP - 8' H.
1.24 STAINLESS STEEL CORNER GUARDS - 4' H.
Lab Upgrades
Mark Date Description
12-04-24 100% CDs
12-20-24 Permit Set
5.4
5.12
5.10
5.2
5.5
5.1
5.16
2' - 0" 3' - 0"
5.17
6' - 0"
MIN.
1' - 3"
5.18
5.8
5.21
5.5
5.21
5.6
5.9
6' - 0"
5.8
5.21
6' - 0"
5.4
5.2
5.6 5.8
5.17
5.21
6' - 0"
5.3 5.8
5.13
5.19
5.20
5.21
6' - 0"
5.8
5.15
CAP FUME HOOD -
REMOVAL IN PHASE 3
5.8
5.22
4' - 0"
5.75.8
CAP FUME HOOD -
REMOVAL IN PHASE 3
8' - 0"
5.13
5.35.7
5.19
5.20
5.21
6' - 0"
5.115.145.3
5.21
5' - 6" 5' - 6"8' - 0"
3' - 4" 3' - 4" 3' - 4"
ALIGN TO (E) WINDOWS
10' - 0" V.I.F.
1" INSUL. TINTED
LOW-E GLAZING, TYP.
DARK BRONZE ALUM.
WDW., TYP.
NEW SILL BLOCK
(E) WDWS. TO REMAIN
(E) INTERIOR WALL
TO REMAIN
OPERABLE HOPPER
WDW., TYP.
A5.0
A5.0
A5.0
NOTE: WINDOW GLAZING TO HAVE U-VALUE
OF .43 MAX. AND SHGC OF .40 MAX.
SHIM AS REQ'D.,
SEALANT &
BACKERROD ALL
SIDES, TYP.
STL. ANGLE, PT. -
RE: STRUCT.
PATCH/PT. CMU ON
INT. SIDE AS REQ'D.
(E) 4" CMU VENEER W/
AIR SPACE ON (E)
INSUL. ON (E) 8" CMU
DARK BRONZE
ALUM. WDW., TYP.
EXTERIORINTERIOR
(E) 4" CMU VENEER W/ AIR
SPACE ON (E) INSUL. ON (E)
8" CMU
SEALANT (BOTH SIDES)
SLOPED SOLID CMU
SILL BELOW
PATCH/PT. CMU ON
INT. SIDE AS REQ'D.
BENT PLATE, PT. -
RE: STRUCT.
DARK BRONZE ALUM.
WDW., TYP.
EXTERIORINTERIOR
3/8" DIA. ANCHOR,
RE: STRUCT.
SEALANT (BOTH SIDES)
PREFIN. MTL. FLASHING
SLOPED SOLID CMU SILL
FLEXIBLE MEMBRANE FLASHING
WITH END DAMS
(E) 4" CMU VENEER W/ AIR
SPACE ON (E) INSUL. ON (E)
8" CMU
PATCH/PT. CMU ON
INT. SIDE AS REQ'D.
2'-0" AFF
1/2" TH. SOLID SURFACE SILL
DRIP EDGE1/2"
CONC.
This is the start of the file's text. The full file is on GovTribe.