Technical Exhibit B-Deliverables Schedule dpg 012826.pdf
PDF 89 KB Posted
- Solicitation number
- W911S6-26-Q-A010
About this file
This is a Deliverables Schedule (Technical Exhibit B) that outlines the contractor's submission requirements for ISO 17025 calibration services.
The contractor must provide on-site support from certified ISO 17025 technicians and submit annual documentation including proof of relevant training and qualifications for each service technician performing calibrations on specified equipment types (analytical balances, flow meters, flow controllers, digital thermometers, and analytical weight sets). The contractor shall include in the proposal package a summary of ISO 17025 calibration procedures intended for use on each equipment type, providing the Government visibility into the calibration process and ensuring alignment with ISO 17025 standards and traceability to appropriate standards. The contractor must maintain ISO 17025 accreditation and submit updated documentation annually to the Contracting Officer's Representative (COR) at the start of each contract year via electronic email.
For deliverables, the contractor shall submit detailed ISO 17025 compliant calibration reports for each instrument within five business days of completing calibration services, either electronically or through database access allowing the COR to download records. Additionally, the contractor must affix a physical calibration label or stamp to each calibrated instrument immediately following calibration, indicating the new calibration date and ISO 17025 accreditation. All documentation submissions are directed to the COR via email.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL EXHIBIT B
Deliverables Schedule
Deliverable Frequency # of Copies Medium/Format Submit To
On-site support from certified ISO 17025 technician
[PWS para. 5.2.2]
Proof of relevant training and qualifications for each service technician performing calibrations on the specified equipment types.
The contractor shall annually submit the updated documentation to the
COR
The contractor will submit an electronic copy to the COR at the start of each contract year.
Documentation shall be submitted via email
The COR
On-site support from certified ISO 17025 technician
[PWS para. 5.2.2] include in their proposal package a summary of the ISO
17025 calibration procedures intended for use on each equipment type
(analytical balances, flow meters, flow controllers, digital thermometers, and analytical weight sets). This will provide the
Government with visibility into the calibration process, ensuring alignment with ISO 17025 standards and traceability to appropriate standards; detailed technical specifics are not required, but a clear overview of the documented
The contractor shall annually submit the updated copy to the COR at the start of each contract year.
Documentation shall be submitted via email
The COR
Deliverable Frequency # of Copies Medium/Format Submit To procedures is necessary.
Maintain ISO 17025
Accreditation
[PWS para. 5.2.4] annually submit the updated copy to the COR at the start of each contract year.
Documentation shall be submitted via email
The COR
Deliverables
[PWS para. 5.2.5.4]
ISO calibration report: A detailed
ISO 17025
compliant report of calibration for each instrument, including all relevant data and traceability information.
The contractor shall submit all calibration reports for each equipment to the COR within five business days of completing the calibration services
The contractor shall either submit an electronic copy to the COR or provide access to the company’s database to allow the COR to download the record.
Documentation shall be submitted via email
The COR
Deliverables
[PWS para. 5.2.5.4]
A physical stamp affixed to each calibrated instrument indicating the new calibration date and
ISO 17025
accreditation
Apply a new calibration label/stamp to each equipment immediately following calibration.
One label or stamp for each equipment
Sticker NA