TECHNICAL EXHIBIT AD
FIRE ALARM SYSTEM INSPECTION CHECKLIST
ALL DEFICIENCIES MUST BE FULLY EXPLAINED ON COMMENT/DEFICIENCY
Building #: Contact Person: Phone#:
Facility type:
| Has Contact Person Been Notified of Test: Yes | No | Time: | ||
| Has Ft. Hood Fire Dept Been Notified: Yes | No | Time: | ||
| Testing/Inspection Conducted By: | NICET# Date: |
System Information:
Panel Number:
Panel Manufacturer:
System Monitoring:
Is this system monitored: Yes No If yes, type of transmitter?
SYSTEM TESTS AND INSPECTION *
| Were all initiating and notification devices unobstructed and visible? Yes | No | |||
| *Annotate Location of all Non-Functional Devices in comments or deficiency reports. | ||||
| TEST RESULTS | ||||
| QTY PASSED | QTY FAILED | Comments |
Manual Pull Stations Smoke Detectors Smoke/heat Combo Heat Detectors Bells Strobes Horns Speakers Strobes w Speakers Strobes w Horns System Switches Duct Detectors Voice Systems System Switches Duct Detectors Other: (Specify)
TECHNICAL EXHIBIT AH
ALL DEFICIENCIES MUST BE FULLY EXPLAINED ON COMMENT/DEFICIENCY PAGE
| Building #: | Contact Person: | Phone#: | ||
| QTY PASSED | QTY FAILED | Comments |
Fire Alarm Panel
Type: Hardwired Multiplex Addressable Other:
Functional Comments:
| Lamps/LEDs | Yes | No | N/A | ||
| Fuses | Yes | No | N/A | ||
| Trouble Signals | Yes | No | N/A | ||
| Zone Disable | Yes | No | N/A | ||
| Supervisory Signal | Yes | No | N/A | ||
| Remote Annunciator | Yes | No | N/A | ||
| Ground Fault | Yes | No | N/A | ||
| Transmitter | Yes | No | N/A | ||
| Batteries | Yes | No | N/A |
Other:
POWER SUPPLIES
| Primary (Main): Nominal Voltage: | Amps: |
| Overcurrent Protection: Type: | Amps: |
Location of Primary Supply Panel:
| Has Lockout Been Provide: Yes | No | Is Circuit Breaker Labeled: Yes | No | |
| Secondary: | Battery Amp-Hour Rating: |
Calculated Battery Back-up Capacity in Hours:
Backup Generator Providing Power to Fire Alarm System: Yes No
TECHNICAL EXHIBIT AH
* ALL DEFICIENCIES MUST BE FULLY EXPLAINED ON COMMENT/DEFICIENCY PAGE
Building #: Contact Person: Phone#:
SUPERVISORY STATION MONITORING
| Functional | Comments: | ||||
| Alarm Signal | Yes | No | N/A | ||
| Time: | |||||
| Alarm Restored | Yes | No | N/A | ||
| Time: | |||||
| Trouble Signal | Yes | No | N/A | ||
| Time: | |||||
| Supervisory Signal | Yes | No | N/A | ||
| Time: | |||||
| Supervisory Restored | Yes | No | N/A | ||
| Time: |
System Restored to Normal Operation: Date: Time:
Inspectors Signature:
Test: Annual_____ Two Year______ Three Year______
COMMENTS/DEFICIENCIES