These are technical drawings and specifications for steel shade structures to be constructed at Goodfellow AFB FAM-CAMP. The drawings show a 25' x 30' steel-framed structure with a height of 16' and includes detailed top, side, front, and isometric views at a 1"=1'-0" scale.
The structure requires TR6x4 and TR6x2 steel members of varying thicknesses (0.25", 0.1875", and 0.075" 14Ga.), with specific quantities listed in the bill of materials. Foundation details specify 1' x 4' round concrete footers with 8" x 6" weld plates and J-bolts. The contractor must install the concrete footers 4' below ground, place J-bolts 6" in the concrete footer, weld steel plates to the steel columns, and position J-bolts 1" x 1" from the corner of the steel plate.