T_-_Tenant_Design_Criteria_-_Exhibits.pdf
PDF 562 KB Posted
- Solicitation number
- RCS 26-0040
- Issued by
- Maricopa County, Phoenix City, Arizona
About this file
This is a Tenant Design Criteria document for the City of Phoenix Aviation Department regarding Food & Beverage concession spaces at Phoenix Sky Harbor International Airport's Terminal 3 North 2 Concourse (T3N2). The document provides detailed architectural specifications and floor plans for apron-level storage units that will support the concession operations. The file includes specifications for three main storage categories: Dry Storage S1 (containing seven units ranging from 129 to 275 square feet), Cold Storage S2 (containing six units ranging from 99 to 127 square feet), and Dry Storage S3 (containing two units of 256 and 927 square feet). All square footage calculations include wall thickness, and the document provides precise dimensional measurements for each individual storage unit, with dimensions ranging from 8'-0" to 30'-0" in length and 10'-2" to 22'-9" in width. The design criteria establish the baseline physical requirements that successful respondents must accommodate within their operational plans for the three concession packages being offered.
The storage specifications detailed in this document directly support the three F&B concession packages outlined in the related solicitation: Package 1 totaling 6,091 square feet (two Quick-Serve Restaurant Concepts, a Cafe Bar, and Beverage Vending Machines), Package 2 consisting of 1,198 square feet for a Coffee Focus plus Cafe small business opportunity, and Package 3 offering 2,267 square feet for a Full-Service Restaurant with Bar. The storage units are sized and configured to provide dedicated, secure facilities for dry and cold inventory management, with individual units marked with fenced boundaries as indicated by the ** notation throughout the plans. Successful respondents will need to integrate these standardized storage areas into their operational and design specifications as part of their concession lease agreements with the City of Phoenix.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APRON LEVEL - CONCESSIONS DRY STORAGE - S1 S1-A
ENLARGED FLOOR PLAN
2469 SF
CONCESSION
STORAGE
S1
8' - 0" 6' - 9"
8' - 0" 9'
- 1 0"
6'
- 0
6"
0"
0"
8'
- 2
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
DRY STORAGE
UNIT S1-A
250 SF *
8’-0” x 30’-0” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
ATTACHMENT T
APRON LEVEL - CONCESSIONS DRY STORAGE - S1 S1-B
2469 SF
CONCESSION
STORAGE
S1
8' - 0" 6' - 9"
8' - 0" 9'
- 1 0"
6'
- 0
6"
0"
0"
8'
- 2
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
DRY STORAGE
UNIT S1-B
250 SF *
8’-0” x 30’-0” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS DRY STORAGE - S1 S1-C
2469 SF
CONCESSION
STORAGE
S1
8' - 0" 6' - 9"
8' - 0" 9'
- 1 0"
6'
- 0
6"
0"
0"
8'
- 2
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
DRY STORAGE
UNIT S1-C
129 SF *
8’-0” x 15’-6” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS DRY STORAGE - S1 S1-D
2469 SF
CONCESSION
STORAGE
S1
8' - 0" 6' - 9"
8' - 0" 9'
- 1 0"
6'
- 0
6"
0"
0"
8'
- 2
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
DRY STORAGE
UNIT S1-D
274 SF *
9’-10” x 22’-9” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS DRY STORAGE - S1 S1-E
2469 SF
CONCESSION
STORAGE
S1
8' - 0" 6' - 9"
8' - 0" 9'
- 1 0"
6'
- 0
6"
0"
0"
8'
- 2
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
DRY STORAGE
UNIT S1-E
197 SF *
8’-0” x 21’-6” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS DRY STORAGE - S1 S1-F
2469 SF
CONCESSION
STORAGE
S1
8' - 0" 6' - 9"
8' - 0" 9'
- 1 0"
6'
- 0
6"
0"
0"
8'
- 2
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
DRY STORAGE
UNIT S1-F
275 SF *
8’-0” x 30’-0” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS DRY STORAGE - S1 S1-G
2469 SF
CONCESSION
STORAGE
S1
8' - 0" 6' - 9"
8' - 0" 9'
- 1 0"
6'
- 0
6"
0"
0"
8'
- 2
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
DRY STORAGE
UNIT S1-G
275 SF *
8’-0” x 30’-0” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS COLD STORAGE - S2 S2-A
1053 SF
CONCESSION COLD
STORAGE
S2
8' - 0" 6' - 9"
8' - 0" 8'
- 0
3"
9"
4"
7'
- 6
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
COLD STORAGE
UNIT S2-A
114 SF *
8’-0” x 13’-9” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS COLD STORAGE - S2 S2-B
1053 SF
CONCESSION COLD
STORAGE
S2
8' - 0" 6' - 9"
8' - 0" 8'
- 0
3"
9"
4"
7'
- 6
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
COLD STORAGE
UNIT S2-B
110 SF *
8’-0” x 13’-3” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS COLD STORAGE - S2 S2-C
1053 SF
CONCESSION COLD
STORAGE
S2
8' - 0" 6' - 9"
8' - 0" 8'
- 0
3"
9"
4"
7'
- 6
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
COLD STORAGE
UNIT S2-C
127 SF *
14’-9” x 8’-0” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS COLD STORAGE - S2 S2-D
1053 SF
CONCESSION COLD
STORAGE
S2
8' - 0" 6' - 9"
8' - 0" 8'
- 0
3"
9"
4"
7'
- 6
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
COLD STORAGE
UNIT S2-D
125 SF *
8’-0” x 13’-4” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS COLD STORAGE - S2 S2-E
1053 SF
CONCESSION COLD
STORAGE
S2
8' - 0" 6' - 9"
8' - 0" 8'
- 0
3"
9"
4"
7'
- 6
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
COLD STORAGE
UNIT S2-E
99 SF *
8’-0” x 10’-10” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS COLD STORAGE - S2 S2-F
1053 SF
CONCESSION COLD
STORAGE
S2
8' - 0" 6' - 9"
8' - 0" 8'
- 0
3"
9"
4"
7'
- 6
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
COLD STORAGE
UNIT S2-F
99 SF *
8’-0” x 10’-10” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS DRY STORAGE - S3
S3-A
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2" 10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
DRY STORAGE
UNIT S3-A
256 SF *
22’-9” x 10’-2” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
APRON LEVEL - CONCESSIONS DRY STORAGE - S3
S3-B
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2" 10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
** INDICATES SIZE OF FENCED UNIT
KEY PLAN
DRY STORAGE
UNIT S3-B
927 SF *
12’-1” x 15’-0” & 22’-9” x 29’-5” **
EXHIBIT
1353 SF
CONCESSION
STORAGE
S3
5"
0"
2"
10' - 8" 12' - 1"
* SQUARE FOOTAGE CALCULATIONS
INCLUDE WALL THICKNESS
January 30, 2026 | Phoenix Sky Harbor International Airport | T3N2 Concessions Tenant Design Criteria
| S1-A |
| S1-B |
| S1-C |
| S1-D |
| S1-E |
| S1-F |
| S1-G |
| S2-A |
| S2-B |
| S2-C |
| S2-D |
| S2-E |
| S2-F |
| S3-A |
| S3-B |
File details come from the government source that posted it. Updated .