Text version
DOUBLE GARAGE
GARAGE STORE
SHR
20mm HWS
20mm CWS
WHB
15mm HWS
15mm CWS
WC
15mm CWS
SHR
20mm HWS
20mm CWS
BATH
20mm HWS
20mm CWS
WHB
15mm HWS
15mm CWS
WC
15mm CWS
BATH
20mm HWS
20mm CWS
WC
15mm CWS
WHB
15mm HWS
15mm CWS
WC
15mm CWS
WHB
15mm CWS
W/MACHINE
20mm HWS
20mm CWS
20mm HWS
20mm CWS along wall
20mm CWS concealed in wall
200 litres Existing Vertically
Mounted pressure geyser
200 litres Horizontally
Mounted pressure geyser
40mm CWS from nearest water source
40mm CWS from nearest water source
32mm cPVC CWS from nearest water source
20mm CWS concealed in wall
40mm CWS
U/S
25mm HWS
25mm CWS concealed in wall
25mm HWS
25mm CWS concealed in wall
25mm HWS
25mm CWS concealed in wall
25mm HWS
25mm CWS along wall
32mm cPVC CWS from nearest water source
150 litres Existing Horizontally
Mounted pressure geyser
15mm CWS concealed in wall
WHB
15mm CWS
SINK
20mm HWS
20mm CWS
DISHWASHER
20mm HWS
20mm CWS
INTERNAL WATER RETICULATION
CLIENT
DATE: 04/2016
TITLE:
PROJECT:
Rev
Description Date
DRAWN: M.M
SCALE: 1/75
CHECKED: DGH
LUSAKA ZAMBIA
DRAWING NUMBER: DH 12/2016/M04(A)
GENERAL WATER SUPPLY PLUMBING
NOTES
FIRST FLOOR
WHB TAP - TO CONNECT TO 15mmØ
APPROVED STEEL BRAIDED FLEXIBLE
CONNECTOR TO CONNECT TO 15mmØ STOPCOCK VALVE TO 15mmØ CWS TO
CONNECT TO INCOMING CWS PIPE
SINK/DISHWASHER- TO CONNECT TO 20mmØ STOPCOCK VALVE TO 20mmØ CWS/HWS TO
CONNECT TO INCOMING CWS/HWS PIPE
WC CISTERN - TO CONNECT TO 15mmØ
STEEL BRAIDED FLEXIBLE CONNECTOR TO
CONNECT TO INCOMING CWS PIPE
THIS DRAWING IS TO BE READ IN
CONJUCTION WITH ALL
RELEVANT ARCHITECTS AND
ENGINEERS DRAWINGS
LEGEND
BWS - BOOSTED WATER SUPPLY
SPS - STANDPIPE SUPPLY
RP - RODDING POINT
FE - FIRE EXTINGUISHER
T/A - TO ABOVE
F/A - FROM ABOVE
T/B - TO BELOW
IV - ISOLATION VALVE
LONGITUDINAL SECTION
THROUGH PIPE TRENCH
D
B
A
A
CROSS SECTION
THROUGH PIPE TRENCH
G.L.
PIPE LAID TO FALL TO APPROVED STANDARDS
D
B
REDEVELOPMENT OF USAID18E LEOPARDS LANE
USAID
REVISED TO SUIT ARCHITECTURAL LAYOUT
05/2017