Text version
DOUBLE GARAGE
GARAGE STORE
GT
GT
GT
SVP
GT
Ø110mm SP/WP TO CONNECT
TO NEAREST MANHOLE
110mm SP
U/S
Ø40mm SP/WP
U/S
Ø50mm WP
U/S
Ø50mm WP
U/S
110mm SP
U/S
2x Ø50mm WP
U/S
Ø110mm SP/WP TO CONNECT
TO NEAREST MANHOLE
Ø40mm WP
U/S
Ø50mm WP
U/S
Ø50mm WP
U/S
Ø110mm SP/WP TO CONNECT
TO NEAREST MANHOLE
svp
GT
Ø110mm SP
U/S
Ø110mm SP/WP TO CONNECT
TO NEAREST MANHOLE
SVP
110mm SP
U/S
110mm SP
U/S
INTERNAL SEWER RETICULATION
CLIENT
DATE: 03/2016
TITLE:
PROJECT:
Rev.
Description Date
DRAWN: M.M
SCALE: 1/75
CHECKED: DGH
LUSAKA ZAMBIA
DRAWING NUMBER:
1.THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL RELEVANT
ARCHITECTS AND ENGINEERS DRAWINGS
2.ALL WASTE AND SEWER PIPES TO BE IN CLASS 16 UPVC MARLEY
PLASTIC OR SIMILAR APPROVED LAID AND JOINTED TO MANUFACTURES
SPECIFIC INSTRUCTIONS.
3.SEWER PIPES LAID UNDER SLAB AND ROADWAYS TO BE ENCASED IN
CONCRETE AND CLEARLY MARKED.
4. MANHOLE COVER IN ROADWAYS TO BE HEAVY DUTY. ELSEWHERE TO
BE MEDIUM DUTY.
LEGEND
SP - SOIL PIPE
SVP - SOIL VENT PIPE
WP - WASTE PIPE
F/A - FROM ABOVE
T/B - TO BELOW
5. GRADIENT FOR THE SEWER PIPE AS FOLLOWS;
110 - 1/80
160 - 1/120
NOTES:
FLOOR DRAIN
INSTALLATION DETAIL.
DRAWN NOT TO SCALE
S L A
B
T
H I C
K N
E S
S
50mm FD
CAST IN SLAB
GENERAL WASTE AND SEWERAGE PLUMBING NOTES
FIRST FLOOR.
WHB - TO CONNECT TO 40mmØ CHROME BOTTLE TRAP
TO CONNECT TO 110mmØ WASTE WATER PIPE.
WC - TO CONNECT TO 100mmØ 'P' TRAP TO CONNECT
TO 110mmØ SP TO CONNECT TO SOIL VENT PIPE AND WASTE PIPE.
SHOWER - TO CONNECT TO 50mmØ SHOWER TRAP TO CONNECT
TO 50mmØ WP TO CONNECT TO 110mm WASTE WATER PIPE.
W/MACHINE - TO CONNECT TO 50mmØ BATH TRAP TO CONNECT TO
50mmØ WP TO CONNECT TO 110mm WASTE WATER PIPE.
FLOOR DRAIN - TO CONNECT TO 50mmØ BATH TRAP TO CONNECT
TO 50mmØ WP TO CONNECT TO 110mm WASTE WATER PIPE.
CAST IRON GRATING
100230100
EE
GULLEY TRAP SECTION
DETAIL PLAN
GULLEY TRAP SECTION DETAIL
PLAN
REDEVELOPMENT OF USAID18E LEOPARDS LANE
USAID
DH 12/2016/M03(A)
REVISED TO SUIT ARCHITECTURAL LAYOUT
05/2017