Statement of Work 03C00737 Boom Truck Repair - PDF.pdf

PDF 71 KB Posted

Attached to
Bucket Truck Repair - Whiteman AFB
Solicitation number
FA462525Q0005
Issued by

About this file

This Statement of Work (SOW) details the repair requirements for an Altec Boom Truck (asset 03C00737) for the US Government. The scope includes comprehensive repair and inspection of the vehicle's fiberglass boom sections, specifically requiring the contractor to replace out-of-date leveling cables, repair stress cracks in upper and lower fiberglass boom sections, refinish spiral cracks, and ensure the vehicle meets manufacturer specifications. The contract includes six Contract Line Item Numbers (CLINs) covering boom refinishing, cable replacement, structural load testing, dielectric testing, operational testing, and provisions for unknown/discovered repairs.

The contract specifies that the US Government will deliver the asset to the contractor's facility and conduct a final inspection upon completion of services. The repair work must comply with multiple safety standards including OSHA 1910.67, OSHA 1910.269, ANSI A92.2, ANSI A92.24, ANSI A92.9, and ASME 91-203. The contractor is required to provide all necessary labor, tools, and materials, and must notify the government of any additional unknown services required before taking action. Each repair task comes with a warranty, and the contractor must provide test reports to the government upon completion of the repairs.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK (SOW)

FOR

ALTEC BOOM TRUCK REPAIR

08 July2025

1.0. General: The US Government requires the repair of an 03C00737 Altec Boom Truck.

1.1. Scope: The Company shall provide all personnel, equipment, tools, materials, supervision, and quality control necessary, to replace the out-of-date leveling cables and inspect upper and lower fiberglass boom sections, repair stress cracks inside of upper and lower fiberglass booms, refinish the upper boom spiral cracks so that vehicle meets or exceeds manufacturer requirements, as defined within this statement of work (SOW).

1.1.1. Objectives: Inspect and repair upper and lower fiberglass boom sections for stress fractures and cracking. Inspect fiberglass to metal connection points to ensure these are serviceable and meet manufacturers specifications, repair inner boom cracks and outer boom spiral cracks, replace out of date leveling cables, perform a structural load test, perform a dielectric test, and perform an operational test after repairs are completed and certify truck is serviceable for all type of repairs following OSHA 1910.67:/OSHA 1910.269: /ANSI A92.2 /ANSI A92.24 /ANSI A92.9 / ASME 91-203. Provide test reports to the government.

CLIN Description Required number

0001 UPPER AND LOWER FIBERGLASS BOOM

REFINISHED AND SPIRAL CRACKS

REPAIRED WITH WARRANTY

1 ea

0002 REPLACE LEVELING CABLES WITH

WARRANTY

1 ea

0003 STRUCTURAL LOAD TEST 1 ea

0004 DIELECTRIC TEST 1 ea

0005 OPERATIONAL TEST 1 ea

0006 UNKNOWN/DISCOVERED REPAIRS 1 lot

2.0. The Contractor shall provide all labor, tools and materials necessary to accomplish the repairs to this unit. Any unknown services required following award of this contract will be brought to the government’s attention prior to taking action.

2.1. Transportation. US Government will deliver asset 03C00737 to contractor facility. US government will inspect/accept vehicle upon completion of service prior to taking ownership of vehicle again.