Statement of Work 03C00737 Boom Truck Repair - 20250826.pdf
PDF 98 KB Posted
- Attached to
- Bucket Truck Repair - Whiteman AFB
- Solicitation number
- FA462525Q0005
About this file
This Statement of Work (SOW) details the repair requirements for a 2003 AM800 Altec Boom Truck for the US Government. The contract includes comprehensive repair and inspection services for the vehicle, specifically focusing on the fiberglass boom sections, including replacing out-of-date leveling cables, repairing stress cracks, refinishing spiral cracks, and ensuring the truck meets manufacturer and safety specifications (OSHA and ANSI standards).
The Statement of Work outlines nine Contract Line Item Numbers (CLINs) covering tasks such as upper and lower fiberglass boom refinishing, leveling cable replacement, structural load testing, dielectric testing, operational testing, and system adjustments. The US Government will deliver the asset (03C00737) to the contractor's facility within a 100-mile radius of Whiteman Air Force Base, with the government inspecting and accepting the vehicle upon completion of service. All repairs must be completed with a warranty, and any unknown or discovered repairs must be brought to the government's attention before action is taken.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK (SOW)
FOR
ALTEC BOOM TRUCK REPAIR
26 August 2025
1.0. General: The US Government requires the repair of an 2003 AM800 Altec Boom Truck.
1.1. Scope: The Company shall provide all personnel, equipment, tools, materials, supervision, and quality control necessary, to replace the out-of-date leveling cables and inspect upper and lower fiberglass boom sections, repair stress cracks inside of upper and lower fiberglass booms, refinish the upper boom spiral cracks so that vehicle meets or exceeds manufacturer requirements, as defined within this statement of work (SOW).
1.1.1. Objectives: Inspect and repair upper and lower fiberglass boom sections for stress fractures and cracking. Inspect fiberglass to metal connection points to ensure these are serviceable and meet manufacturers specifications, repair inner boom cracks and outer boom spiral cracks, replace out of date leveling cables, perform a structural load test, perform a dielectric test, and perform an operational test after repairs are completed and certify truck is serviceable for all type of repairs following OSHA 1910.67:/OSHA 1910.269: /ANSI A92.2 /ANSI A92.24 /ANSI A92.9 / ASME 91-203. Provide test reports to the government.
CLIN Description Required number
0001 UPPER AND LOWER FIBERGLASS BOOM
REFINISHED AND SPIRAL CRACKS
REPAIRED WITH WARRANTY
1 ea
0002 REPLACE LEVELING CABLES WITH
WARRANTY
1 ea
0003 STRUCTURAL LOAD TEST 1 ea
0004 DIELECTRIC TEST 1 ea
0005 OPERATIONAL TEST 1 ea
0006 ADJUST LEVELING SYSTEM AFTER LOAD
TESTING
1 ea
0007 SUPPLIES AND ENVIRONMENTAL 1 ea
0008 FREIGHT AND FEES 1 ea
0009 UNKNOWN/DISCOVERED REPAIRS 1 Lot
2.0. The Contractor shall provide all labor, tools and materials necessary to accomplish the repairs to this unit. Any unknown services required following award of this contract will be brought to the government’s attention prior to taking action.
2.1. Transportation. US Government will deliver asset 03C00737 to contractor facility. The government will not travel more than 100 mile radius from Whiteman AFB. US government will inspect/accept vehicle upon completion of service prior to taking ownership of vehicle again.