Statement of Work 03C00737 Boom Truck Repair - 20250814.pdf
PDF 97 KB Posted
- Attached to
- Bucket Truck Repair - Whiteman AFB
- Solicitation number
- FA462525Q0005
About this file
This Statement of Work (SOW) details the repair requirements for a 2003 AM800 Altec Boom Truck, asset number 03C00737, located at Whiteman Air Force Base. The government requires comprehensive repair services including replacing out-of-date leveling cables, inspecting and repairing upper and lower fiberglass boom sections for stress fractures and cracks, refinishing boom surfaces, and ensuring the vehicle meets manufacturer specifications.
The SOW specifies six Contract Line Item Numbers (CLINs) for the repair process: refinishing fiberglass boom sections with warranty, replacing leveling cables, performing a structural load test, conducting a dielectric test, completing an operational test, and addressing any unknown/discovered repairs. The contractor must follow safety standards including OSHA 1910.67, OSHA 1910.269, ANSI A92.2, ANSI A92.24, ANSI A92.9, and ASME 91-203. The US Government will deliver the vehicle to the contractor's facility within a 100-mile radius of Whiteman AFB and will inspect and accept the vehicle upon completion of services.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK (SOW)
FOR
ALTEC BOOM TRUCK REPAIR
14 August 2025
1.0. General: The US Government requires the repair of an 2003 AM800 Altec Boom Truck.
1.1. Scope: The Company shall provide all personnel, equipment, tools, materials, supervision, and quality control necessary, to replace the out-of-date leveling cables and inspect upper and lower fiberglass boom sections, repair stress cracks inside of upper and lower fiberglass booms, refinish the upper boom spiral cracks so that vehicle meets or exceeds manufacturer requirements, as defined within this statement of work (SOW).
1.1.1. Objectives: Inspect and repair upper and lower fiberglass boom sections for stress fractures and cracking (please see attachment 1 for reference photos).
Inspect fiberglass to metal connection points to ensure these are serviceable and meet manufacturers specifications, repair inner boom cracks and outer boom spiral cracks, replace out of date leveling cables, perform a structural load test, perform a dielectric test, and perform an operational test after repairs are completed and certify truck is serviceable for all type of repairs following OSHA
1910.67:/OSHA 1910.269: /ANSI A92.2 /ANSI A92.24 /ANSI A92.9 / ASME 91-203.
Provide test reports to the government.
CLIN Description Required number
0001 UPPER AND LOWER FIBERGLASS BOOM
REFINISHED AND SPIRAL CRACKS
REPAIRED WITH WARRANTY
1 ea
0002 REPLACE LEVELING CABLES WITH
WARRANTY
1 ea
0003 STRUCTURAL LOAD TEST 1 ea
0004 DIELECTRIC TEST 1 ea
0005 OPERATIONAL TEST 1 ea
0006 UNKNOWN/DISCOVERED REPAIRS 1 lot
2.0. The Contractor shall provide all labor, tools and materials necessary to accomplish the repairs to this unit. Any unknown services required following award of this contract will be brought to the government’s attention prior to taking action.
2.1. Transportation. US Government will deliver asset 03C00737 to contractor facility. The government will not travel more than 100 mile radius from Whiteman AFB. US government will inspect/accept vehicle upon completion of service prior to taking ownership of vehicle again.