About this file
This is an asbestos survey report conducted by Trust Thermal in May 2017 for the DNR Rose Lake Field Office Building located at 8562 E. Stoll Road in East Lansing, MI. The inspection was performed to fulfill EPA NESHAP requirements and AHERA guidelines, identifying the presence and quantity of asbestos-containing materials (ACM) prior to any renovation or demolition work. The survey was completed by AHERA-certified inspectors Jeff Brook and Mark Wilson and analyzed by SanAir Technologies Laboratory.
The inspection identified 15 different asbestos-containing materials present in the building, including various floor tiles (6% and 4% asbestos), plaster ceiling (2%), multiple types of caulk (2-3%), adhesives (2-3%), boiler seam mud (3%), sink undercoatings (4-6%), vent pipe (20%), transite panels (20%), roof tar (10%), and fire doors (assumed ACM). The materials were found throughout different areas of the building including flooring, walls, ceilings, mechanical spaces, and exterior surfaces. The report notes that if any of these materials are to be disturbed during renovation or demolition, they must be removed by a licensed asbestos abatement contractor in accordance with EPA regulations. Detailed floor plans and sample locations were included, along with photo documentation and laboratory analysis results for all tested materials.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Clarification.dotx | DOTX file | |
| Addendum 1 19255.pdf | ||
| Specs Rose Lake Vol 4.pdf | ||
| Addendum 2.pdf | ||
| Specs Rose Lake Vol 2.pdf | ||
| Specs Rose Lake Vol 5.pdf | ||
| Specs Rose Lake Vol 6.pdf | ||
| Advertisement 19255.pdf | ||
| Specs Rose Lake Vol 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX E
PREVIOUS ASBESTOS SURVEY
OF
FIELD OFFICE BUILDING
210 S. Water Street, Owosso, MI. 48867 Phone 989-720-8834 Fax 989-720-8836 www.trustthermal.com
ASBESTOS SURVEY
Location:
8562 E. Stoll Road
East Lansing, MI 48823
May 2017
!2
A asbestos inspection was conducted at 8562 E. Stoll Road in fulfillment of 40 CFR 61, Subpart M, of asbestos NESHAP requirements and done in accordance with inspection guidelines as set forth in 40
CFR 761, AHERA.
The EPA under the National Emission Standards for Hazardous Air Pollutants (NESHAP) requires that prior to the start of a renovation or demolition project, the building must be inspected for asbestos containing materials (ACM). The purpose of this inspection was to determine the presence and quantity of asbestos containing materials. If any asbestos containing materials are to be disturbed for a renovation or demolition, the ACM must be removed by a licensed asbestos abatement contractor.
A material is considered to be asbestos containing when it contains greater than one percent (<1%) asbestos as determined by PLM lab analysis. Any assumed asbestos containing material listed in the report was either inaccessible during inspection or known to be asbestos containing.
The quantities listed in this report are approximate estimates. It is the contractor’s responsibility to verify quantities for bidding purposes. In the event that any building materials that are not identified in this report are uncovered during any demolition or renovation activities, work should stop and these materials should be tested for asbestos or assumed to be asbestos containing material.
Inspection completed by: Report prepared by:
Jeff Brook, Mark Wilson, Trust Thermal Trust Thermal AHERA Inspector AHERA Inspector Accreditation #A15191 Accreditation #A9777
!3
The following summery of homogenous areas (HA) were determined to be asbestos containing materials:
HA: Material: Amount: Location(s) Results:
1 Tan 9”x9” Tile 2,300 sq.ft. Throughout 6% Asbestos
2 Dark Brown 9”x9” Tile 2,300 sq.ft. Throughout 4% Asbestos
3 Med Brown 9”x9” Tile 2,300 sq.ft. Throughout 6% Asbestos
7 Plaster Ceiling 200 sq.ft. Receiving Area 2% Asbestos
8 Brown Caulk 1 sq.ft. Receiving Area 3% Asbestos
10 Tan Caulk 5 sq.ft. Door Frames 2% Asbestos
11 Tan Adhesive 6 sq.ft. Restroom 1 3% Asbtesos
12 Boiler Seam Mud 3 sq.ft. Boiler Room 3% Asbestos
15 White Sink Undercoating 30 sq.ft. Restrooms 4% Asbestos
24 Grey Vent Pipe 5 ln.ft. Lab 20% Asbestos
25 Paneling Adhesive 325 sq.ft. Reception Area 2% Asbestos
26 Black Sink Undercoating 1 Sink Restroom 1 6% Asbestos
32 Transite Panels 2,700 sf.ft Exterior 20% Asbestos
33 Roof and Penetration Tar 100 sq.ft. Throughout 10% Asbestos
28 Fire Doors 10 ea. Throughout Assumed ACM
!4
The following is a list of materials that were suspect ACM in the building. They were sampled and listed by homogenous areas (HA):
1. Floor Tile (9”x9” Tan) – Approximately 2,300 sq.ft. was located throughout and was suspect ACM. It was sampled and labeled as #1. Lab results indicate that there is 6% asbestos detected.
2. Floor Tile (9”x9” Dark Brown) - Approximately 2,300 sq.ft. was located throughout and was suspect ACM. It was sampled and labeled as #2. Lab results indicate that there is 4% asbestos detected.
!5
3. Floor Tile (9”x9” Med Brown) – Approximately 2,300 sq.ft. was located throughout and was suspect ACM. It was sampled and labeled as #3. Lab results indicate that there is 6% asbestos detected.
4. Counter Top Linoleum – Approximately 80 sq.ft. was located in Room S1 and was suspect ACM. It was sampled and labeled as #4. Lab results indicate that there is no asbestos detected.
!6
5. Cove Base Adhesive – Approximate quantities indeterminate, adhesive was located throughout the building and was suspect ACM. It was sampled and labeled as #5, 18. Lab results indicate that there is no asbestos detected.
6. Plaster – Approximately 10,400 sq.ft was located throughout and was suspect ACM. It sampled and labeled as #6, 13, 19, 22, 28, 31. Lab results indicate that there is no
!7
7. Plaster Ceiling – Approximately 200 sq.ft was located in the Receiving Area and was suspect ACM. It sampled and labeled as #7. Lab results indicate that there is 2% asbestos detected.
8. Caulk (Brown) – Approximately 1 sq.ft. was located in the Receiving Area and was suspect ACM. It was sampled and labeled as #8. Lab results indicate that there is 3% asbestos
!8
9. Caulk (White) – Approximately 1 sq.ft. was located on the windows in Receiving Area was suspect ACM. It was sampled and labeled as #9. Lab results indicate that there is no asbestos detected.
10.Caulk (Tan) – Approximately 5 sq.ft. was located on the door frames was suspect ACM. It was sampled and labeled as #10. Lab results indicate that there is 2% asbestos detected.
!9
11. Adhesive (Tan) - Approximately 6 sq.ft. was located in the Restroom 1 and was suspect ACM.
It was sampled and labeled as # 12. Lab results indicate that there 3% asbestos detected.
12. Boiler Seam Mud (Grey) - Approximately 3 sq ft. was located on the grey boiler was suspect ACM. It was sampled and labeled as #14. Lab results indicate that there 3% asbestos
!10
13.Boiler Fire Brick (White) - Approximately 20 sq ft. was located on the grey boiler was suspect ACM. It was sampled and labeled as #16. Lab results indicate that there no asbestos detected.
14.Boiler Fire Brick (Red) - Approximately 20 sq ft. was located on the Blue Boiler was suspect ACM. It was sampled and labeled as #17. Lab results indicate that there no asbestos
!11
15.Sink Undercoating (Grey) - Approximately 30 sq ft. was suspect ACM. It was sampled and labeled as #15. Lab results indicate that there 4% asbestos detected.
16.Paneling Adhesive (Tan) - Approximately 800 sq.ft. was located throughout was suspect ACM. It was sampled and labeled as #20. Lab results indicate that there no asbestos
!12
17.Ceiling Tile (White 12”x12”) - Approximately 2,600 sq.ft. was suspect ACM. It was sampled and labeled as #21. Lab results indicate that there no asbestos detected.
18.Ceiling Tile (White Dot & Fissure 2”x4”) - Approximately 6,000 sq ft. was suspect ACM. It was sampled and labeled as #23. Lab results indicate that there no asbestos detected.
!13
19.Ceiling Tile (Smooth White 12”x12”) - Approximately 20 sq ft. was suspect ACM. It was sampled and labeled as #24. Lab results indicate that there no asbestos detected.
20.Ceiling Tile (White Fissured 12”x12”) - Approximately 30 sq ft. was suspect ACM. It was sampled and labeled as #25. Lab results indicate that there no asbestos detected.
!14
21.Ceiling Tile (White Textured 12”x12”) - Approximately 30 sq ft. was suspect ACM. It was sampled and labeled as #26. Lab results indicate that there no asbestos detected.
22.Paneling Adhesive (Yellow) - Approximately 600 sq.ft. was suspect ACM. It was sampled and labeled as #27. Lab results indicate that there no asbestos detected.
!15
23.Paneling Board (White) - Approximately 600 sq.ft. was suspect ACM. It was sampled and labeled as #14. Lab results indicate that there no asbestos detected.
24.Vent Pipe (Grey) - Approximately 5 ln.ft. located in the Lab and was suspect ACM. It was sampled and labeled as #30. Lab results indicate that there 20% asbestos detected.
!16
25.Paneling Adhesive (Brown) - Approximately 325 sq.ft. was located in the reception area was suspect ACM. It was sampled and labeled as #32. Lab results indicate that there 2% asbestos detected.
26.Sink Undercoating (Black) - Approximately 1 sink was located in Restroom 1 was suspect ACM. It was sampled and labeled as #33. Lab results indicate that there 6% asbestos
!17
27.Carpet Adhesive - Approximately 3 sq.ft. was located on the grey boiler was suspect ACM. It was sampled and labeled as #34. Lab results indicate that there asbestos detected.
28.Paneling adhesive (Grey) - Approximately 775 sq.ft. was located in the break room was suspect ACM. It was sampled and labeled as #35. Lab results indicate that there no
!18
29.Drywall/Joint Compound - Approximately 5,500 sq.ft. was suspect ACM. It was sampled and labeled as #36, 37, 38, 47 48. Lab results indicate that there no asbestos detected.
30.Pipe Fitting Insulation - Approximately 100 ln.ft. was suspect ACM. It was sampled and labeled as #39. Lab results indicate that there no asbestos detected.
!19
31.Floor Tile/ Mastic (Cream 12”x12”) - Approximately 200 sq.ft. was located in Restroom 6 was suspect ACM. It was sampled and labeled as #40. Lab results indicate that there no asbestos detected in tile or mastic.
32.Transite Panels - Approximately 2,700 sq.ft. was suspect ACM. It was sampled and labeled as #41. Lab results indicate that there 20% asbestos detected.
!20
33.Tar - Approximately 75 sq.ft. was suspect ACM. It was sampled and labeled as #11, 42 & 45.
Lab results indicate that there 10% asbestos detected.
34.Roofing Shingle - Approximately 7,000 sq.ft. was located on the grey boiler was suspect ACM. It was sampled and labeled as #43. Lab results indicate that there no asbestos
!21
35.Roofing Felt - Approximately 7,000 sq.ft. was suspect ACM. It was sampled and labeled as #44. Lab results indicate that there no asbestos detected.
36.Concrete Slab - Approximately 7,000 sq.ft. was suspect ACM. It was sampled and labeled as #46, 49. Lab results indicate that there no asbestos detected.
!22
37.Counter Top (Black)- Approximately 15 sq.ft. was suspect ACM. It was sampled and labeled as #50. Lab results indicate that there no asbestos detected.
38.Fire Doors - Approximately 10 ea. was suspect ACM. Doors were not sampled and tested.
Doors are assumed to be asbestos containing.
!23
Summary of Impact of Asbestos Containing Materials
Trust Thermal’s inspection of the facility identified 15 asbestos containing materials present. In accordance with the EPA’s National Emissions Standard for Hazardous Air Pollutants (NESHAP), if this material is to be disturbed for a renovation or demolition, these identified materials must be removed by a licensed asbestos abatement contractor.
Field Drawings and Sample Locations:
!24
SanAir Technologies LaboratorySanAir Technologies Laboratory
Analysis Report prepared for
Trust Thermal
Report Date: 5/17/2017 Project Name: DNR Rose Lake Project #: 1705-274 SanAir ID#: 17017784
804.897.1177 www.sanair.com804.897.1177 www.sanair.com
SanAir Technologies Laboratory, Inc.
1551 Oakbridge Drive, Suite B, Powhatan, VA 23139
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Trust Thermal 210 S. Water St Owosso, MI 48867
May 17, 2017
SanAir ID # 17017784 Project Name: DNR Rose Lake Project Number: 1705-274
Dear J. Brook, We at SanAir would like to thank you for the work you recently submitted. The 50 sample(s) were received on Tuesday, May 16, 2017 via FedEx. The final report(s) is enclosed for the following sample(s): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50.
These results only pertain to this job and should not be used in the interpretation of any other job.
This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information sample conditions:
50 sample(s) in Good condition
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
Trust Thermal 210 S. Water St Owosso, MI 48867
Project Number:
P.O. Number:
Project Name:
1705-274
DNR Rose Lake
Collected Date:
Received Date:
Report Date:
Analyst:
5/12/2017
5/16/2017 10:25:00 AM
5/17/2017 2:29:51 PM
Wilson, Johnathan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 1 / 17017784-001 Brown 94% Other 6% Chrysotile Flooring Material, Flooring Non-Fibrous
Homogeneous 1 / 17017784-001 Black 2% Cellulose 98% Other None Detected Flooring Material, Mastic Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 2 / 17017784-002 Brown 96% Other 4% Chrysotile Flooring Material, Flooring Non-Fibrous
Homogeneous 2 / 17017784-002 Black 2% Cellulose 98% Other None Detected Flooring Material, Mastic Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 3 / 17017784-003 Brown 94% Other 6% Chrysotile Flooring Material, Flooring Non-Fibrous
Homogeneous 3 / 17017784-003 Black 2% Cellulose 98% Other None Detected Flooring Material, Mastic Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 4 / 17017784-004 Brown 40% Cellulose 60% Other None Detected Flooring Material, Flooring Non-Fibrous
Heterogeneous 4 / 17017784-004 Yellow 3% Cellulose 97% Other None Detected Flooring Material, Mastic Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 5 / 17017784-005 Brown 2% Cellulose 98% Other None Detected Adhesive Non-Fibrous
Homogeneous
17017784 SanAir ID Number
FINAL REPORT
Certification
Analyst: Approved Signatory:
Analysis Date: 5/17/2017 Date: 5/17/2017 Page 3 of 15
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
Trust Thermal 210 S. Water St Owosso, MI 48867
Project Number:
P.O. Number:
Project Name:
1705-274
DNR Rose Lake
Collected Date:
Received Date:
Report Date:
Analyst:
5/12/2017
5/16/2017 10:25:00 AM
5/17/2017 2:29:51 PM
Wilson, Johnathan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 6 / 17017784-006 Grey 100% Other None Detected Ceiling Material, Plaster Non-Fibrous
Homogeneous 6 / 17017784-006 White 100% Other None Detected Ceiling Material, Skim Coat Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 7 / 17017784-007 Off-White 2% Cellulose 94% Other 2% Chrysotile Ceiling Material Non-Fibrous 2% Glass
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 8 / 17017784-008 Grey 2% Cellulose 95% Other 3% Chrysotile Countertop Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 9 / 17017784-009 White 100% Other None Detected Window Caulk Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 10 / 17017784-010 Tan 2% Wollastonite 96% Other 2% Chrysotile Door Caulk Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 11 / 17017784-011 Black 98% Other 2% Chrysotile Tar Non-Fibrous
Homogeneous
17017784 SanAir ID Number
FINAL REPORT
Certification
Analysis Date: 5/17/2017 Date: 5/17/2017 Page 4 of 15
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
Trust Thermal 210 S. Water St Owosso, MI 48867
Project Number:
P.O. Number:
Project Name:
1705-274
DNR Rose Lake
Collected Date:
Received Date:
Report Date:
Analyst:
5/12/2017
5/16/2017 10:25:00 AM
5/17/2017 2:29:51 PM
Wilson, Johnathan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 12 / 17017784-012 Tan 97% Other 3% Chrysotile Adhesive Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 13 / 17017784-013 Off-White 100% Other None Detected Ceiling Material, Plaster Non-Fibrous
Homogeneous 13 / 17017784-013 White 100% Other None Detected Ceiling Material, Skim Coat Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 14 / 17017784-014 Grey 97% Other 3% Chrysotile Insulation Material Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 15 / 17017784-015 Purple 96% Other 4% Chrysotile Tar Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 16 / 17017784-016 Cream 100% Other None Detected Boiler Brick Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 17 / 17017784-017 Red 100% Other None Detected Boiler Brick Non-Fibrous
Homogeneous
17017784 SanAir ID Number
FINAL REPORT
Certification
Analysis Date: 5/17/2017 Date: 5/17/2017 Page 5 of 15
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
Trust Thermal 210 S. Water St Owosso, MI 48867
Project Number:
P.O. Number:
Project Name:
1705-274
DNR Rose Lake
Collected Date:
Received Date:
Report Date:
Analyst:
5/12/2017
5/16/2017 10:25:00 AM
5/17/2017 2:29:51 PM
Wilson, Johnathan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 18 / 17017784-018 Brown 100% Other None Detected Adhesive Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 19 / 17017784-019 Grey 100% Other None Detected Wall Material, Plaster Non-Fibrous
Homogeneous 19 / 17017784-019 White 100% Other None Detected Wall Material, Skim Coat Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 20 / 17017784-020 Yellow 100% Other None Detected Adhesive Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 21 / 17017784-021 White 90% Cellulose 10% Other None Detected Ceiling Material Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 22 / 17017784-022 Grey 100% Other < 1% Chrysotile Wall Material, Plaster Non-Fibrous
Homogeneous 22 / 17017784-022 White 100% Other None Detected Wall Material, Skim Coat Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 23 / 17017784-023 White 60% Cellulose 15% Other None Detected Ceiling Material Fibrous 15% Glass
Homogeneous 10% Min. Wool
17017784 SanAir ID Number
FINAL REPORT
Certification
Analysis Date: 5/17/2017 Date: 5/17/2017 Page 6 of 15
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
Trust Thermal 210 S. Water St Owosso, MI 48867
Project Number:
P.O. Number:
Project Name:
1705-274
DNR Rose Lake
Collected Date:
Received Date:
Report Date:
Analyst:
5/12/2017
5/16/2017 10:25:00 AM
5/17/2017 2:29:51 PM
Wilson, Johnathan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 24 / 17017784-024 White 60% Cellulose 15% Other None Detected Ceiling Material Fibrous 15% Glass
Homogeneous 10% Min. Wool
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 25 / 17017784-025 White 90% Cellulose 10% Other None Detected Ceiling Material Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 26 / 17017784-026 White 60% Cellulose 15% Other None Detected Ceiling Material Fibrous 15% Glass
Homogeneous 10% Min. Wool
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 27 / 17017784-027 Yellow 100% Other None Detected Adhesive Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 28 / 17017784-028 Grey 100% Other < 1% Chrysotile Wall Material, Plaster Non-Fibrous
Homogeneous 28 / 17017784-028 White 100% Other None Detected Wall Material, Skim Coat Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 29 / 17017784-029 White 90% Cellulose 10% Other None Detected Wall Material Fibrous
Homogeneous
17017784 SanAir ID Number
FINAL REPORT
Certification
Analysis Date: 5/17/2017 Date: 5/17/2017 Page 7 of 15
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
Trust Thermal 210 S. Water St Owosso, MI 48867
Project Number:
P.O. Number:
Project Name:
1705-274
DNR Rose Lake
Collected Date:
Received Date:
Report Date:
Analyst:
5/12/2017
5/16/2017 10:25:00 AM
5/17/2017 2:29:51 PM
Wilson, Johnathan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 30 / 17017784-030 Grey 80% Other 10% Chrysotile Duct Material Non-Fibrous 10% Crocidolite
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 31 / 17017784-031 White 15% Cellulose 85% Other None Detected Ceiling Material, Drywall Non-Fibrous
Homogeneous 31 / 17017784-031 Grey 100% Other None Detected Ceiling Material, Plaster Non-Fibrous
Homogeneous 31 / 17017784-031 White 100% Other None Detected Ceiling Material, Skim Coat Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 32 / 17017784-032 Grey 4% Cellulose 94% Other 2% Chrysotile Adhesive Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 33 / 17017784-033 Black 94% Other 6% Chrysotile Sink Tar Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 34 / 17017784-034 Yellow 2% Cellulose 98% Other None Detected Adhesive, Adhesive Non-Fibrous
Homogeneous 34 / 17017784-034 Clear 3% Cellulose 97% Other None Detected Adhesive, Adhesive Non-Fibrous
Homogeneous
17017784 SanAir ID Number
FINAL REPORT
Certification
Analysis Date: 5/17/2017 Date: 5/17/2017 Page 8 of 15
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
Trust Thermal 210 S. Water St Owosso, MI 48867
Project Number:
P.O. Number:
Project Name:
1705-274
DNR Rose Lake
Collected Date:
Received Date:
Report Date:
Analyst:
5/12/2017
5/16/2017 10:25:00 AM
5/17/2017 2:29:51 PM
Wilson, Johnathan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 35 / 17017784-035 Grey 2% Cellulose 98% Other None Detected Adhesive Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 36 / 17017784-036 White 15% Cellulose 85% Other None Detected Wall Material Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 37 / 17017784-037 White 15% Cellulose 80% Other None Detected Wall Material, Drywall Non-Fibrous 5% Glass
Homogeneous 37 / 17017784-037 White 2% Cellulose 98% Other None Detected Wall Material, Joint Compound Non-Fibrous
Homogeneous 37 / 17017784-037 White 2% Cellulose 98% Other None Detected Wall Material, Texture Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 38 / 17017784-038 White 15% Cellulose 80% Other None Detected Wall Material, Drywall Non-Fibrous 5% Glass
Homogeneous 38 / 17017784-038 White 2% Cellulose 98% Other None Detected Wall Material, Texture Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 39 / 17017784-039 Grey 15% Glass 85% Other None Detected Pipe Insulation Non-Fibrous
Homogeneous
17017784 SanAir ID Number
FINAL REPORT
Certification
Analysis Date: 5/17/2017 Date: 5/17/2017 Page 9 of 15
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
Trust Thermal 210 S. Water St Owosso, MI 48867
Project Number:
P.O. Number:
Project Name:
1705-274
DNR Rose Lake
Collected Date:
Received Date:
Report Date:
Analyst:
5/12/2017
5/16/2017 10:25:00 AM
5/17/2017 2:29:51 PM
Wilson, Johnathan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 40 / 17017784-040 White 100% Other None Detected Flooring Material, Flooring Non-Fibrous
Homogeneous 40 / 17017784-040 Black 3% Cellulose 97% Other None Detected Flooring Material, Mastic Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 41 / 17017784-041 Grey 80% Other 20% Chrysotile Roof Material Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 42 / 17017784-042 Black 8% Cellulose 92% Other None Detected Roof Material Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 43 / 17017784-043 Various 15% Glass 85% Other None Detected Roof Material Non-Fibrous
Heterogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 44 / 17017784-044 Black 65% Cellulose 35% Other None Detected Roofing Material Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 45 / 17017784-045 Black 90% Other 10% Chrysotile Roofing Material Non-Fibrous
Homogeneous
17017784 SanAir ID Number
FINAL REPORT
Certification
Analysis Date: 5/17/2017 Date: 5/17/2017 Page 10 of 15
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
Trust Thermal 210 S. Water St Owosso, MI 48867
Project Number:
P.O. Number:
Project Name:
1705-274
DNR Rose Lake
Collected Date:
Received Date:
Report Date:
Analyst:
5/12/2017
5/16/2017 10:25:00 AM
5/17/2017 2:29:51 PM
Wilson, Johnathan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 46 / 17017784-046 Grey 100% Other None Detected Flooring Material Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 47 / 17017784-047 Off-White 15% Cellulose 80% Other None Detected Ceiling Material, Drywall Non-Fibrous 5% Glass
Homogeneous 47 / 17017784-047 White 2% Cellulose 98% Other None Detected Ceiling Material, Texture Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 48 / 17017784-048 White 15% Cellulose 80% Other None Detected Wall Material, Drywall Non-Fibrous 5% Glass
Homogeneous 48 / 17017784-048 White 2% Cellulose 98% Other None Detected Wall Material, Joint Compound Non-Fibrous
Homogeneous 48 / 17017784-048 White 2% Cellulose 98% Other None Detected Wall Material, Texture Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 49 / 17017784-049 Grey 100% Other None Detected Flooring Material Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 50 / 17017784-050 Black 100% Other None Detected Countertop Material Non-Fibrous
Homogeneous
17017784 SanAir ID Number
FINAL REPORT
Certification
Analysis Date: 5/17/2017 Date: 5/17/2017 Page 11 of 15
Disclaimer
The final report cannot be reproduced, except in full, without written authorization from SanAir.
Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client ! s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.
For NY state samples, method EPA 600/M4-82-020 is performed.
Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.
NY ELAP lab ID 11983
Bidding and Contract Document (5/19) Project Name: Rose Lake Wildlife Area File No. 751/19255.KSZ
APPENDIX VI
BLANK
(Asbestos Survey by Trust Thermal Attached in
DLZ’s Asbestos Report)