Specification 5 - CLIN 0005 OCC roll off NASWI.docx
DOCX document 27 KB Posted
- Attached to
- ISWM Steel Containers Federal contract opportunity
- Solicitation number
- N6843622RC001YE
About this file
This document outlines specifications for six steel containers required by the Naval Facilities Engineering Systems Command for integrated solid waste management programs. The specifications include dimensions, materials, markings, and quantities required for containers including a 15-yard once-container cardboard recycling roll-off for Naval Air Station Whidbey Island, with four slots cut into the sides for cardboard. Interested small businesses should review the requirements and submit capabilities statements by August 3rd, 2022 demonstrating experience manufacturing containers per the specifications provided. The North American Industry Classification code for this potential award is 332439 for metal tank and container manufacturing.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Specification 1 - CLIN 0001 40 yard roll off NBK.docx | DOCX document | |
| Specification 3 - CLIN 0003 Boeing Scrap Box.docx | DOCX document | |
| Specification 2 - CLIN 0002 8 yard Packer Box.docx | DOCX document | |
| Specification 6 - CLIN 0006 Three sort recycle roll off NSE.docx | DOCX document | |
| Specification 4 - CLIN 0004 Multi sort roll off NASWI.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specification 5:
1. 15 Yard OCC roll off NASWI
2. Container is not considered off the shelf but it is a standard 20 yard roll off container with a solid roof and 4 slots cut into the side of the container to receive cardboard recycling.
3. This specification is for Naval Air Station Whidbey Island (NASWI) Integrated Solid Waste Program (ISWP).
a. Ship to: 3485 N. Langley Blvd., Bldg 2555, Oak Harbor, WA 98278
b. Customer will offload containers from haulers trailer at location listed in 3.a
c. Hauler does not need to apply for an access card. NASWI ISWP will escort hauler from NASWI truck inspection gate. It is recommend that the vendor use a hauling company with TWIC drivers.
d. Vendor is required to coordinate delivery date with NASWI ISWP by contacting them at least a week in advance of delivery.
4. Qty 4
5. All drawings are not to scale. All pictures with dimensions are not to scale. Both are for reference.
6. Roll off containers for this specification will be built for a Stellar Hook-lift.
a. Made to fit and work on a Stellar Slider26 system.
b. https://www.stellarindustries.com/download/StellarHookliftSpecBook.pdf
c. Reference the Stellar Industries Spec Book from link to reference information for the frame requirements of a roll off container to work on the Stellar Slider26 system.
d. It is recommended that contractor also contacts Stellar Industries to ensure the hook and rail system will be built in accordance with Stellar Industries specification to work on their hook lift systems.
7. Solid welded on roof.
a. Peak roof.
8. Dimensions of the roll off container.
a. Standard 15 yard roll off dimension.
b. Single swing rear door.
i. Hinged on passenger side.
ii. Heavy Duty Hinges.
9. OCC slot openings
a. 4 total – two on each side.
b. Spaced equal distant on each side of the roll off.
c. Opening for each slot is 48 inches wide by 8 inches high.
d. Bottom of the slot will be 40 inches up from the floor of the roll-off.
e. See drawing D#4 for reference.
10. Primer/Paint of container
a. Interior and exterior rust inhibitor primer – 2 coats
b. Exterior Rust inhibitor paint – 2 coats – color = safety orange
c. Meet all State and Federal Regulation regarding proper reflective markings.
d. All containers will be dry before shipping.
a. All containers will be loaded on trailer for shipment to avoid damage during transportation.
b. White block vinyl letter, weather and heat resistant, on each side of the container:
i. Wording - “NASWI ISWM 360-257-5481” (see drawing #D4 for example. Example not to scale and is only an example of the lettering for the container)
ii. Wording to be space equally across both sides of the container to be read from left to right when look at the wording.
NASWI ISWM 360-257-5481
#D4