Questions-Answers for SP4702-21-R-0020.pdf

PDF 1 MB Posted

Attached to
Project: CSC-20007 Maintenance & Repair Building 22 Federal contract opportunity
Solicitation number
SP4702-21-R-0020
Issued by
Defense Logistics Agency

View the file

Other files for this federal contract opportunity

Other files attached to Project: CSC-20007 Maintenance & Repair Building 22, newest first.
File Type Posted
Amendment 03-SP4702-21-R-0020-SF30.pdf PDF
Amendment 03 Continue sheet SF30.pdf PDF
Amendment 02-SP4702-21-R-0020-SF30.pdf PDF
Amendment 02 Continue sheet SF30.pdf PDF
Amendment 01-SP4702-21-R-0020-SF30 (1).pdf PDF
Continue sheet SF30.pdf PDF
Revised SPEC 20007.pdf PDF
Attachment 06-Drawings 3-1708 CSC-20007.pdf PDF
Attachment 04-ENG FORM 4025-R.pdf PDF
Attachment 09-Contractor Access Badge Request.xlsx XLSX spreadsheet
Attachment 02-ENG FORM 93.pdf PDF
Attachment 03-DSCC Excavation Permit.pdf PDF
Attachment 05-Bid forms of CSC-20007.xlsx XLSX spreadsheet
Attachment 01-Wage Rate DOL.pdf PDF
Attachment 08-CSC-20006 NEPA Review Checklist.xlsx XLSX spreadsheet
SP4702-21-R-0020.pdf PDF
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions & Answers for SP4702-21-R-0020:

Question #1 Scope of Work on sheet 3 of 6 Coded Notes.

#1 Ask to install (1) New Elkay Bar II Ultra Water Cooler Bottle Filling Station with built-in filtration system.

#2 Ask to install New Bottle Filling Station Aqua Bar II Ultra Water Cooler in the Buggy Room 164.

Need to know if both of these are to be the Aqua Bar II units in both locations? See attached models.

Elkay does make a similar free-standing unit but not a “Bar II”.

The Aqua Units do not have drain connection so the Buggy Room would not require a drain line to be installed. Please clarify if we are to install a new drain line.

Answer to Question 1- Please install the ELKAY EZH2O for all of them. Please see attached the submittal.

Question #2 Sheet 2 of 6 Intercom / Speaker System Plan: Is there an electrical routing plan / details for connecting the speakers Coded note #1 to the intercom coded note #2 at the front desk? Wiring to be feed through conduit?

Answer to Questions 2- Speakers will NOT be connected to the intercom. Intercom will be separate on the main door close to the receptionist. New two speakers to be installed on the locations marked on to the drawing and to be connected to the main amplifier. Wiring to be feed in conduit is not necessary. Please see attached submittals for BOGEN system.