Attachment 17 - Japan PBC Training Catalog v10262018.xlsx

XLSX spreadsheet 66 KB Posted

Attached to
Sasebo HW Disposal Federal contract opportunity
Solicitation number
SP450020R0008
Issued by
Defense Logistics Agency

View the file

Other files for this federal contract opportunity

Other files attached to Sasebo HW Disposal, newest first.
File Type Posted
Solicitation SP450020R0008 - Q and A_20200203.docx DOCX document
Attachment 00 - Sasebo PWS UPDATED 20200203.docx DOCX document
Attachment 01 - BID Sasebo HW_UPDATED 20200203.xlsx XLSX spreadsheet
SF1449_SP450020R0008.pdf PDF
Attachment 14 - USFJ LABEL NO 5 Asbestos Bag_English_Japanese.pdf PDF
BID Sasebo HW_UPDATED 20190918.xlsx XLSX spreadsheet
Attachment 16 - Facility Profile Sheet.pdf PDF
Attachment 08 - Qualified Facility List Update - DLA Form 2507-2.pdf PDF
Attachment 05 - Acceptable Performance Levels Table (APL).pdf PDF
Attachment 15 - Loading Assistance and Government Scales 9-11-2019 .pdf PDF
Attachment 04 - Primary Pick-up Locations_20190912 .pdf PDF
Attachment 10 - Manifest Tracking Log_DLA Form 2505.pdf PDF
Attachment 13 - Example of a Certificate of Destruction.pdf PDF
Attachment 00 - Sasebo PWS UPDATED 20190917.pdf PDF
Attachment 06 - Quality Assurance and Surveillance Plan (QASP).pdf PDF
Attachment 07 - Qualified Facility List Application DLA Form 2507-1.pdf PDF
Attachment 12 - Certificate of Recycling.pdf PDF
Attachment 11 - DD Form 1155 Order for Supplies or Services.pdf PDF
Attachment 09 - Transporter Qualification Review Application_2503.pdf PDF
Attachment 03 - Acronyms.pdf PDF
Attachment 02 - Definitions.pdf PDF
Attachment 18 - Example of a Certificate of Demilitarization.pdf PDF
Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Japan Profile-Base CLIN Catalog The following is a catalog of Pofile-Based CLIN (PBC) descriptions, physical states, listed by Base CLIN.

Contractors and Government personnel are advised that these CLINs are only available for new contracts and modifications to existing contracts. CLIN descriptions are subject to change. Information contained herein is accurate as of the date of publication. NOTE: List of previously used JCLINs is not all inclusive cross-reference.

Base CLINPreviously used J CLINJapan Profile-Based CLINs (PBCs) Waste Description per Waste Profile Sheet As of 26 October 2018Physical State
Batteries for Recycle / Disposal
BA01C7J13010, J1301B, J1301RSludge, Alkaline Batteries, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Various
BA02C7J13010, J1301CSludge, Calcium Chromate (CaCrO4) Thermal Batteries, Deactivated, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Solid
BA03C7J1301D, J1301RSludge, Carbon-Zinc (CZn) Batteries, Zinc Air, may be managed as IW/Regulated, for Recycling or Disposal.Solid
BA04C7J1301ESludge, Lead Acid Batteries, Wet, Dry or Gel Pack may be managed as IW/Regulated, for Recycling/Recovery Only.Various
BA05C7J1301F, J1303RSludge, Lithium Ion (Li-Ion) Batteries, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Various
BA06C7J1301G, J1303RSludge, Lithium Iron Disulfide (Li2FeS2) Thermal Batteries, including fully discharged Lithium Alloy Thermal Batteries, Deactivated, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Solid
BA07C7J1301H, J1303RSludge, Lithium Manganese (LiMn and Oxides thereof) Batteries, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Solid
BA08C7J1310I, J13030Sludge, Lithium Sulfur Dioxide (LiSO2) Batteries, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Solid
BA09C7J1301J, J13030Sludge, Lithium Thionyl Chloride (LiSCl) Batteries, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Solid
BA10C7J1301K, J13030Sludge, Lithium Batteries, Mixed Types, Deactivated if Applicable, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Solid
BA11C7J13010, J1301L, J1303RSludge, Magnesium (Mg) Batteries, may be managed as IW/Regulated, for Recycling or Destruction and Disposal.Solid
BA12C7J13010, J1301MSludge, Mercury (Hg) Batteries, may be managed asRegulated, for Recycling or Destruction & Disposal.Solid
BA13C7J1301N, J1301R, J1303RSludge, Nickel Metal Hydride (NiMh) Batteries, Wet and Dry may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Solid
BA14C7J1301O, J1301R, J1303RSludge, Nickel-Cadmium (NiCd) Batteries, Wet and Dry, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Various
BA15C7J1301P, J1303RSludge, Silver-Zinc (AgZn) and Zinc Silver Oxide (ZnAgO) Batteries, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.Various
Corrosives
CS01J31010, J3101A, J3101MWaste Acids, Organic or Inorganic other than HF and HNO3, pH 2.1 - 6.9, No Heavy Metals, Managed as IW.Liquid
CS02J32010, J33010, J3301A, J33020, J3301B, J3301MWaste Acids, Organic or Inorganic other than HF and HNO3, pH <7.0, May contain JEGS or GOJ waste codes, Managed as Regulated.Liquid
CS03J32010Waste Acids, Oraganic or Inorganic other than HF and HNO3, Concentrated, pH≤2.0, May contain JEGS or GOJ waste codes, Managed as Regulated.Liquid
CS04Waste Acids, Chromic (H2Cr04 ), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris. Managed as IW.Various
CS05Waste Acids, Chromic (H2Cr04 ), 1-10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris. May contain JEGS or GOJ waste codes, Managed as Regulated.Various
CS06Waste Acids, Chromic (H2Cr04), >10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris. May contain JEGS or GOJ waste codes, Managed as Regulated.Various
CS07Waste Acids, Chromic (H2Cr04 ), >100 ppm Cr+6, F-Listed Liquids, Solids, Sludges, Debris. May contain JEGS or GOJ waste codes, Managed as Regulated.Various
CS08Waste Acids, Non-Fuming, Hydrofluoric (HF) <40% and Nitric (HNO3), <25% in Water. Managed as IW.Liquid
CS09Waste Acids, Fuming, Hydrofluoric (HF) >40% and Nitric (HNO3), ≥75% in Water, <1% Total Metals, Cr+6 <100 ppm. May contain JEGS or GOJ waste codes, Managed as Regulated.Liquid
CS10J11050, J41010, J4101M,Waste Alkaline, Organic or Inorganic, pH 7.1 - 12.4, No heavy metals, Managed as IW.Various
CS11J4302C, J4302R, J42010, J43010, J43020, J4302CWaste Alkalines, Organic or Inorganic, May contain JEGS or GOJ Regulated Materials, pH >7.0, Managed as Regulated.Liquid
CS12J41010Waste Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, FLP ≥158◦FVarious
CS13J1104C, J11050, J1105M, J11040, J1104A, J1104MWaste Organic Acids or Bases, Liquids/Sludges/Solids/Debris, FLP ≥158◦F, pH 2.1 - 12.4, May contain JEGS or GOJ waste codes, Managed as Regulated.Various
CS14NewWaste Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.Liquid
CS40J42010Waste Alkalines, Organic or Inorganic, May contain JEGS or GOJ Regulated Materials, pH ≥12.5, Managed as Regulated.Liquid
CS99J11010, J1102O, J13010, J13070, J21020, J22020, J23020, J43020, J51010Military Items, Demil-Required, Corrosive Solids/Liquids/Debris, i.e. CDE Kits, Vials, Filters, PPE, etc. for Conventional Treatment and Disposal. Certificate of Disposal/Destruction Required.Various
Compressed Gas Cylinders / Cartridges

Size (Suffix): Lecture (ME) = 3"x 12" • Small (M1) = 4"x 24" • Medium (M2) = 12"x 36" • Large (M3) = 16"x 56"

CY08J62010, J62020Cylinders, Propane.Comp. Gas
CY09J62020Cylinders, Acetylene, Empty, Contains Asbestos.Comp. Gas
CY12J62010, J62020Cartridges, Flammable Gas, AVGAS, Gas/Diesel Starting, for Disposal/Recycle. Diameter up to 3", Length up to 10" e.g. Ether Cylinders.Comp. Gas
CY40J65010, J6501M, J6202ACompressed gas cylinders, Inert, Graded Breathing Air, Non-Flammable Gases, May include fire extinguishers, No Halon.Comp. Gas
CY41J62010, J62020Compressed gas cylinders, Flammable gases, Managed as Regulated.Comp. Gas
CY42J62010Compressed gas cylinders, Corrosive gases, Managed as Regulated.Comp. Gas
CY43J6201ACompressed gas cylinders, Toxic gases, Managed as Regulated.Comp. Gas
CY44J72010, J7201A, J7201MOzone Depleting Substances, JEGS or GOJ designated hazardous substances, Halon. Managed as Regulated.Various
Flammable/Combustible/ Ignitable
FL01C7J21010, J2101A, J2101M, J22010, J2201M, J23040, J2201B, J2201N, J2201AWaste Oil / Non-Foaming, Flammable, Corrosive, Aerosols; may include JEGS or GOJ designated hazardous substances. Managed as IW/RegulatedAerosol
FL02J23060, J2306M, J13300Sludge, Industrial Waste, Flammable Debris, Contaminated with Common Solvents, Shreddable, e.g., absorbents, rags, PCP wood. No Free Liquids, No large metal, rock, or masonry components; Managed as IW/RegulatedVarious
FL03J11010, J1101A, J1101B, J1101M, J1101R, J1106B, J11070, J11090, J2101M, J21020, J51010, J5101MSludge, Industrial Waste, Flammable, Liquids/Solids/Sludges/Debris, e.g., ordinary industrial waste, sludge, absorbents, lubricants, adhesives, rags, filters, PPE, non-reactive paint waste with isocyanates, Managed as IW/Regulated.Various
FL04J23030, J23050, J43020Sludge, Waste Flammable and Corrosive Liquids/Solids/Sludges/Debris, pH 2.1 - 12.4, Contaminated with Volitile Organic Compounds, (VOC) and other halogentated solvents. Managed as Regulated.Various
FL05J22020, J23010, J2301M, J23020, J23030, J2301RWaste Oil, Flammable Liquids Only, Pumpable for fuels blending, May include JEGS or GOJ designated hazardous substances. Managed as Regulated.Liquid
FL06J22020Waste Oil, Flammable Liquids Only, Pumpable for fuels blending, No heavy metals, May include JEGS or GOJ designated hazardous substances. Managed as Regulated.Liquid
FL07NewWaste Oil,Flammable Liquids, Pumpable for fuels blending, Lean to Rich, >2,500 BTU/Lb, 5-10% Total ChlorineLiquid
FL08NewWaste Oil, Flammable Resuspendable Liquids w/Solids/Sludges, Rich, >7,000 BTU/Lb, <5% Total ChlorineVarious
FL09NewWaste Oil,Flammable Resuspendable Liquids w/Solids/Sludges, Lean, 2,500-7,000 BTU/Lb, <5% Total ChlorineVarious
FL10NewWaste Oil, Flammable Resuspendable Liquids w/Solids/Sludges, Lean to Rich, >2,500 BTU/Lb, 5-10% Total ChlorineVarious
FL11NewSludge, Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.Liquid
FL12J11030, J13200, J13210Sludge, Flammable, Containing High VOC, Chlorinated (>10%) and Halogenated solvents, Insecticides, Herbicides, Fungacides and Pesticides. JEGS or GOJ Regulated, No PCBs, Dioxins, Furans, or Precursors. Managed as Regulated.Various
FL13J11020, J1102A, J1102CSludge, Oxidizers, Non-Reactive, other than chromic acid (see Corrosives), Liquids/Sludges/Solids/Debris, May contain JEGS or GOJ Regulated, Managed as IW / Regulated.Various
FL14Waste Oil, Paints, Loose-Packed small containers, Oil-Based, and Paint-Related Materials, >2,500 BTU/Lb. No Isocyanates (See Base CLIN NR06 for 100% Latex)Various
FL15Water Contaminated with Solvents, Pumpable, <2,500 BTU/LbLiquid
FL40J13070Waste Reagents and Chemicals. RegulatedVarious
FL41J11010, J11020, J11040, J11050, J1307AWaste Reagents and Chemicals. IWVarious
FL99J1102O, J13010, J23010, J23020, J43010Military Items, Demil-Required, Flammable Solids/Liquids/Debris, i.e. CDE Kits, Vials, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.Various
Lab Packs / Loose Packs (Over-packed Small Containers < pint to ≤ 5GL)
LP01NewLab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.Various
LP02NewLab Packs/Loose Packs, Mercury, Elemental Liquid.Various
LP03NewLap Packs/Loose Packs, Flammables and Flammable Corrosives other than Paints eligible for FL14.Various
LP04NewLab Packs/Loose Packs, Non-Regulated Industrial Waste, other than Water-Based paints (Latex).Various
LP05NewLab Packs/Loose Packs, Non-Reactive Oxidizers.Various
LP06NewLab Packs/Loose Packs, Reactive Oxidizers, Includes Organic Peroxides, Special Packaging May Be Required.Various
LP07NewLab Packs/Loose Packs, Reactive Metals, Wet/Dry, Includes Broken Sodium Lamps and MRE heaters. Special Packaging May Be Required.Various
LP08NewLab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing. Special Packaging May Be Required.Various
LP09NewLab Packs/Loose Packs, Toxic Metals.Various
LP10NewLab Packs/Loose Packs, Toxic Organics.Various
LP11NewLab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, including listed pharmaceuticals. Allows for packaging with U-Listed waste.
Various
LP12NewLab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals.Various
LP13NewLab Packs/Loose Packs, Pesticides.Various
Non-Regulated
NR01NewNon-RCRA Solids, Direct Landfill Ready. No Free Liquids. Non-Cumbustible Ordinary Industrial Wastes.Solid
NR02J85010, J8501A, J8501M, J85050, J8505M,
Non-Dispersal Asbestos, Non-Friable Asbestos Containing Materials, ≥0.1% asbestos by weight. Other than Regulated waste, Special Packaging Required. No Free Liquids. Managed as IW/Regulated. (See RG01 for dispersable asbestos)Solid
NR03J21020, J31010Non-Regulated Liquids, Aqueous (Water based). Wastewater treatment and discharge.Liquid
NR04J41010Non-Regulated Liquids, Pumpable, Organic-Based, i.e., primarily consisting of compound(s) containing hydrocarbons.Liquid
NR06J21010Sludge, Loose-Packed Paints, including 100% Water-Based, e.g., Latex.Various
NR07NewUnused Pharmaceutical Materials for Thermal Destruction.Various
NR11NewSludge, Industrial Waste, Combustible Solids for Waste-To-Energy (WTE) Disposal. May contain some free liquids.Various
NR40J11010, J87100, J8710KPetroleum contaminated soils, Managed as Non-Regulated.Various
NR79NewSludge, Industrial Waste,Solids, POL-Contaminated Items, e.g., Pads, Rags, Booms, Sweepables, etc. Contractor returns empty drums to Generator for reuse.Solid
NR91AFFF-Contaminated Solids/Sludges/Debris for Incineration, e.g., Soil, PPE, Filter Media, Empty Containers, May contain some free liquids. Certificate of Disposal/ Destruction Required.Various
NR93J43010, J43201AAFFF Concentrate Liquid for Incineration, Unused or >10% AFFF Product, Pumpable. Containing PFOA/PFOS. Certificate of Disposal/Destruction Required.Liquid
NR94AFFF Rinsate/Water-Diluted Liquid for Incineration, Used or >90% Water, Pumpable. Containing PFOA/PFOS. Certificate of Disposal/Destruction Required.Liquid
NR95Non-Regulated Electron Tubes for Demil and Disposal. Certificate of Disposal/ Destruction Required.Solid
NR96Non-Regulated Liquids for Incineration, Pumpable.Liquid
NR97J11010, J11050, J21020, J31010, J41010, J51010Non-Regulated Industrial Waste, Solids/Sludges/Debris for Incineration. May contain some free liquids.Various
NR98J51010Non-Regulated Military Articles, Demil-Required, e.g., Boots, Gloves, CDE Kits, Filters, Masks, MOPP Suits, etc. Certificate of Disposal/ Destruction Required. No Uniforms or Submarine Tiles.Various
PCB-Related ** DO NOT APPLY TO JAPANESE CONTRACTS
PC01PCB and PCB/RCRA-Mixed Waste Contaminated with or Containing >50 ppm Source, i.e. Debris, Sludge, Water, Leaking Capacitors, Fluids other than Transformer Mineral Oil. Certificate of Destruction Required.Various
PC02PCB Mineral Oil from Transformers, 1-49 ppm PCBs, Non-RegulatedLiquid
PC03PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs. Non-Regulated, Certificate of Recycling or Destruction Required.Liquid
PC04PCB Mineral Oil , Water, Other Fluids, >4,000 ppm PCBs. Certificate of Destruction Required.Liquid
PC05PCB Oil-Filled Capacitors/Equipment other than Transformers, 1-49 ppm PCBs, Non-RegulatedVarious
PC06PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, >50 ppm PCBs, INon-Regulated, Certificate of Recycling or Destruction Required.Various
PC07PCB Oil-Filled Transformers, 1-49 ppm PCBs, Non-Regulated.Various
PC08PCB Oil-Filled Transformers, >50 ppm PCBs. Certificate of Recycling or Destruction Required.Various
PC09PCB Solids/Debris Contaminated with 1-49 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-RegulatedSolid
PC10PCB Solids/Debris Contaminated with >50 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-Regulated. Certificate of Disposal, Recycling or Destruction Required.Solid
Recycle/Recovery
RE01C7J1308M, J1308R, J1308T, J1308USludge, Lamps, Fluorescent, Intact, Linear, CFLs, U-Bent, and Circulars. Intact. Managed as Regulated.Solid
RE02J13080, J1308NSludge, Crushed/Broken Lamps, Fluorescent, with Filters and debris.Solid
RE03J1308A, J1308OSludge, Lamps, Halogen (May include broken lamps)Solid
RE04J1308B, J1308P, J13120Sludge, Lamps, High Intensity Discharge (HID), Light Emitting Diode (LED) (May include broken lamps)Solid
RE05J1308C, J1308Q, J13120Sludge, Lamps, Mercury/Mercury Vapor (May include broken lamps)Solid
RE06J1308D, J13120Sludge, Lamps, Metal Halide and Metal Hydride, including Sodium (May include broken lamps)Solid
RE07J13070Sludge, Mercury, High, COD Vials, Nessler's Reagent, Chemicals and Residues, Hg>15 mg/Kg Hg<1000 mg/kgVarious
RE08J13400Sludge, Mercury, High, Unused Dental Amalgams, Debris & Residues, Hg >15 mg/Kg. Managed as Regulated. May container Silver and Mercury.Various
RE09J13070Sludge, Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg>1000 mg/Kg. i.e. Elemental Mercury Only.Various
RE10J2112M, J2112N, J2112R, J21120Waste Oil, Antifreeze, Used and Unused for Recycling or Fuels Blending. Managed as Non-Regulated. Certificate of Recycle Required.Liquid
RE11NewUsed Oil, <10% Water, <1,000 ppm Total Organic Halides. For Recycling or Fuels Blending, Waste to Energy.Liquid
RE12Used Oil, >10% Water, <1,000 ppm Total Organic Halides. For Recycling or Fuels Blending, Waste to Energy.Liquid
RE13J1301A, J1302A, J5101A, J5101NSludge, Used Oil Filters, Drained and Undrained, and/or Fully Drained Fuel Filters. Certificate of Recycle Required.Various
RE79J1309R, J1309USludge, Sandblast media for recycling. Managed as IW.Solid
GOJ Regulated Wastes
RG01J83030, J8303MWaste Dispersable/Friable Asbestos, Building Maintenance ACM, GOJ Regulated, Special Packaging Required. No Free Liquids. Managed as Regulated.Solid
RG02J85010, J8501A, J8501M, J85050, J8505M,
Waste Non-Dispersable/Non-Friable Asbestos, Building Maintenance ACM, GOJ Regulated, Special Packaging Required. No Free Liquids. Managed as Regulated.Solid
RG03J87200, J8720KPetroleum Contaminted Soils with heavy metals, Magaged as RegulatedSolid
Reactive
RX02J1102E, J13050Sludge, Cyanide,>50% Debris, >590 mg/Kg Total CN

DMK0016: DMK0016:

Various
RX03J1102F, J13050Sludge, Cyanide, <50% Debris, (1%) Total CNVarious
RX04J1102G, J13050Sludge, Cyanide, <50% Debris, 1%-10% Total CNVarious
RX05J1102HSludge, Cyanide, <50% Debris, >10% Total CNVarious
RX06J11020, J1102DSludge, Reactive Oxidizers, e.g., Nitrates, Nitrites, Persulfates, Inorganic Peroxides, No Organic PeroxidesVarious
RX07J11020, J1102ISludge, Polymerizing Materials, e.g, Styrene, Isocyanates, AcrylatesVarious
RX08J1101C, J1102J, J1102P, J11080Sludge, Reactive Metals, e.g., Powders, Dusts, Fines. Air/Water Reactive. Shipped Under Oil and/or Special Packaging May Be required.Solid
RX09J1101C, J1102K, J11080Reactive Metals, Debris. Air/Water Reactive. Shipped Under Oil and/or Special Packaging May Be Required.Solid
RX10J1102L, J13070Sludge, Reactive Non-Metals, e.g., P-Coded, Temperature Sensitive, PIHs, Air/Water Reactive.Various
RX40J1101C, J11060, J13200Sludge, Liquids, Organic/Inorganic Peroxides. Managed as Regulated.Various
RX95J1102M, J13050Sludge, Reactive, Ignitable, and Toxic Solids, e.g., tank bottoms, sludge, and/or debris for Thermal Destruction. Contaminated with Mineral Spirits, Motor Oil, Alcohol, Solvents, and Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.Solid
RX97J1102M, J23020Sludge, Reactive, Ignitable, and Toxic Liquid for Thermal Destruction. Contains Water, Mineral Spirits, Motor Oil, Alcohol, Solvents, and Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total Metals.Liquid
RX98J1102N, J13050Sludge, OBA Cannisters, EEBD and Oxygen Candles, Potentially Reactive, Spent and/or Unspent. Special packaging may be required.Solid
RX99J1102O, J13070Military Items, Demil-Required, Reactive, Must Carry D003, Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. (No Batteries) for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.Various
Toxic
TX01NewSludge, Chromium, Hexavalent, <1% Cr+6, Characteristic Liquids, Solids, SludgesVarious
TX02NewSludge, Chromium, Hexavalent, 1-10% Cr+6, Characteristic Liquids, Solids, SludgesVarious
TX03NewSludge, Chromium, Hexavalent, >10% Cr+6, Characteristic Liquids, Solids, SludgesVarious
TX04NewSludge, Chromium, Hexavalent, <1% Cr+6, Listed Liquids, Solids, SludgesVarious
TX05NewSludge, Chromium, Hexavalent, Wastewater, Pumpable, <1% Total MetalsLiquid
TX06NewDebris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. No free liquids unless incidental rainwater/condensation (See TX20).Various
TX07NewDebris, Organic and/or Inorganic Constituents. >50% Debris by volume, >60 mm (~2.5") Particle size. Total VOCs <500 ppm. No free liquids unless incidental rainwater/condensation (see TX20).Various
TX08NewDioxins, Furans, and Precursors. Liquids, Solids, Sludges, Debris.Various
TX09NewHigh Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides, Characteristic/ListedVarious
TX10NewSludge, Metals in Wastewater, <5% Suspended Solids, <1% Total Sludge, Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/ListedLiquid
TX11NewSludge, Metals in Wastewater, <5% Suspended Solids, >1% Total Sludge, Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/ListedLiquid
TX12NewSludge, Metals-Bearing Liquids, Low, <1% TCLP Sludge, Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, CharacteristicLiquid
TX13NewSludge, Metals-Bearing Liquids, Low, <1% TCLP Sludge, Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, ListedLiquid
TX14NewSludge, Metals-Bearing Liquids, High, >1% TCLP Sludge, Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, CharacteristicLiquid
TX15NewSludge, Metals-Bearing Liquids, High, >1% TCLP Sludge, Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, ListedLiquid
TX16NewSludge, Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Sludge, Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, CharacteristicVarious
TX17NewSludge, Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Sludge, Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, ListedVarious
TX18NewSludge, Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Sludge, Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, CharacteristicVarious
TX19NewSludge, Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Sludge, Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, ListedVarious
TX20J13010, J1301C, J1301D, J1301R, J13040Sludge, Metals-Bearing Debris/Solids/Sludges with Free Liquids, Contains JEGS/GOJ Characteristic/ListedVarious
TX21NewOrganics Contaminated Water, Pumpable, <10% Suspended Solids, <10% Organics, e.g., Toluene, Phenol in water. Not more toxic than common solvents.Liquid
TX22J13010, J13050, J13060Organics or Inorganics in Solids/Sludges/Debris, i.e. Tank & Still Bottoms, Filtercake. Not more toxic than common solvents.Various
TX24NewOrganic Solvents, Technical Grade Pure or Mixed Solutions, With or Without Water and/or Metals, Pumpable, Flashpoint ≥140°F.
Liquid
TX97NewToxic Electron Tubes for Demil and Disposal, Intact, Certificate of Disposal/Destruction Required.Solid
TX98NewMilitary Items, Demil-required, RCRA Toxic, i.e. CDE Kits, Tents, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.Various
TX99NewMilitary Submarine Tiles, Demil-Required via Incinerator. Use this CLIN even when no toxic Waste Codes apply. Certificate of Destruction Required.Solid

PBC w Waste Codes The following is a catalog of Pofile-Based CLIN (PBC) descriptions, physical states, listed by Base CLIN.

Contractors and Government personnel are advised that these CLINs are only available for new contracts and modifications to existing contracts. CLIN descriptions are subject to change. Information contained herein is accurate as of the date of publication.

Base CLINJapan Profile-Based CLINs (PBCs) Waste Description per Waste Profile Sheet As of 22 April 2018Physical StatePermissble Waste Codes (e.g., EPA, JGEGS and GOJ)
Batteries for Recycle / Disposal
BA01C7Sludge, Alkaline Batteries, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.VariousIndustrial Waste, D002, J002
BA02C7Sludge, Calcium Chromate (CaCrO4) Thermal Batteries, Deactivated, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.SolidIndustrial Waste, D001, J001 (Oxidizer), D002, J002, D003-11
BA03C7Sludge, Carbon-Zinc (CZn) Batteries, Zinc Air, may be managed as IW/Regulated, for Recycling or Disposal.SolidIndustrial Waste, D002, J002, D004-11
BA04C7Sludge, Lead Acid Batteries, Wet, Dry or Gel Pack may be managed as IW/Regulated, for Recycling/Recovery Only.VariousIndustrial Waste, D002, J002, D004-11
BA05C7Sludge, Lithium Ion (Li-Ion) Batteries, may be managed as IW/Regulated, for Recycling/Recovery Only.SolidIndustrial Waste, D002, J002, D004-11
BA06C7Sludge, Lithium Iron Disulfide (Li2FeS2) Thermal Batteries, including fully discharged Lithium Alloy Thermal Batteries, Deactivated, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.SolidIndustrial Waste, D002, J002, D004-11
BA07C7Sludge, Lithium Manganese (LiMn and Oxides thereof) Batteries, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.SolidIndustrial Waste, D002, J002, D004-11
BA08C7Sludge, Lithium Sulfur Dioxide (LiSO2) Batteries, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.SolidIndustrial Waste, D002, J002, D004-11
BA09C7Sludge, Lithium Thionyl Chloride (LiSCl) Batteries, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.SolidIndustrial Waste, D002, J002, D004-11
BA10C7Sludge, Lithium Batteries, Mixed Types, Deactivated if Applicable, may be managed as IW/Regulated, for Recycling or Destruction & Disposal.SolidIndustrial Waste, D002, J002, D004-11
BA11C7Sludge, Magnesium (Mg) Batteries, may be managed as IW/Regulated, for Recycling or Destruction and Disposal.SolidIndustrial Waste, D002, J002, D004-11
BA12C7Sludge, Mercury (Hg) Batteries, may be managed asRegulated, for Recycling/Recovery Only.SolidIndustrial Waste, D002, J002, D004-11
BA13C7Sludge, Nickel Metal Hydride (NiMh) Batteries, Wet and Dry may be managed as IW/Regulated, for Recycling/Recovery Only.VariousIndustrial Waste, D002, J002, D004-11
BA14C7Sludge, Nickel-Cadmium (NiCd) Batteries, Wet and Dry, may be managed as IW/Regulated, for Recycling/Recovery Only.VariousIndustrial Waste, D002, J002, D004-11
BA15C7Sludge, Silver-Zinc (AgZn) and Zinc Silver Oxide (ZnAgO) Batteries, may be managed as IW/Regulated, for Recycling/Recovery Only.SolidIndustrial Waste, D002, J002, D004-11
Corrosives
CS01Waste Acids, Organic or Inorganic other than HF and HNO3, pH 2.1 - 6.9, No Heavy Metals, Managed as IW.LiquidD002, J002, D004-11, Listed Inorganics
CS02Waste Acids, Organic or Inorganic other than HF and HNO3, pH <7.0, May contain JEGS or GOJ waste codes, Managed as Regulated.LiquidD002, J002, D004-11, Listed Inorganics
CS03Waste Acids, Oraganic or Inorganic other than HF and HNO3, Concentrated, pH≤2.0, May contain JEGS or GOJ waste codes, Managed as Regulated.LiquidD002, J002, D004-11, Listed Inorganics
CS04Waste Acids, Chromic (H2Cr04 ), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris. Managed as IW.VariousD001 (Oxidizer) D002, J002, D004-11
CS05Waste Acids, Chromic (H2Cr04 ), 1-10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris. May contain JEGS or GOJ waste codes, Managed as Regulated.VariousD001 (Oxidizer) D002, J002, D004-11
CS06Waste Acids, Chromic (H2Cr04), >10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris. May contain JEGS or GOJ waste codes, Managed as Regulated.VariousD001 (Oxidizer) D002, J002, D004-11
CS07Waste Acids, Chromic (H2Cr04 ), >100 ppm Cr+6, F-Listed Liquids, Solids, Sludges, Debris. May contain JEGS or GOJ waste codes, Managed as Regulated.VariousD001 (Oxidizer), D002, J002, D004-11, F-Listed, U032
CS08Waste Acids, Non-Fuming, Hydrofluoric (HF) <40% and Nitric (HNO3), <25% in Water. Managed as IW.LiquidD001 (OX), D002, J002, D004-11, Listed Inorganics
CS09Waste Acids, Fuming, Hydrofluoric (HF) >40% and Nitric (HNO3), ≥75% in Water, <1% Total Metals, Cr+6 <100 ppm. May contain JEGS or GOJ waste codes, Managed as Regulated.LiquidD001 (OX), D002, J002, D004-11, Listed Inorganics
CS10Waste Alkaline, Organic or Inorganic, pH 7.1 - 12.4, No heavy metals, Managed as IW.VariousD002, J002, D004-11, Listed Inorganics
CS11Waste Alkalines, Organic or Inorganic, May contain JEGS or GOJ Regulated Materials, pH >7.0, Managed as Regulated.LiquidD002, J002, D004-11, Listed Inorganics
CS12Waste Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, FLP ≥158◦FVariousD002, J002, D004-11, Listed
CS13Waste Organic Acids or Bases, Liquids/Sludges/Solids/Debris, FLP ≥158◦F, pH 2.1 - 12.4, May contain JEGS or GOJ waste codes, Managed as Regulated.VariousD002, J002, D004-11, Listed
CS14Waste Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.LiquidD002, J002, D004-11, Listed
CS40Waste Alkalines, Organic or Inorganic, May contain JEGS or GOJ Regulated Materials, pH ≥12.5, Managed as Regulated.LiquidD002, J002, D004-11, Listed
CS99Military Items, Demil-Required, Corrosive Solids/Liquids/Debris, i.e. CDE Kits, Vials, Filters, PPE, etc. for Conventional Treatment and Disposal. Certificate of Disposal/Destruction Required.Various
Compressed Gas Cylinders / Cartridges

Size (Suffix): Lecture (ME) = 3"x 12" • Small (M1) = 4"x 24" • Medium (M2) = 12"x 36" • Large (M3) = 16"x 56"

CY08Cylinders, Propane.Comp. Gas
CY09Cylinders, Acetylene, Empty, Contains Asbestos.Comp. Gas
CY12Cartridges, Flammable Gas, AVGAS, Gas/Diesel Starting, for Disposal/Recycle. Diameter up to 3", Length up to 10" e.g. Ether Cylinders.Comp. Gas
CY40Compressed gas cylinders, Inert, Graded Breathing Air, Non-Flammable Gases, May include fire extinguishers, No Halon.Comp. Gas
CY41Compressed gas cylinders, Flammable gases, Managed as Regulated.Comp. Gas
CY42Compressed gas cylinders, Corrosive gases, Managed as Regulated.Comp. Gas
CY43Compressed gas cylinders, Toxic gases, Managed as Regulated.Comp. Gas
CY44Ozone Depleting Substances, JEGS or GOJ designated hazardous substances, Halon. Managed as Regulated.Various
Flammable/Combustible/ Ignitable
FL01C7Waste Oil / Non-Foaming, Flammable, Corrosive, Aerosols; may include JEGS or GOJ designated hazardous substances. Managed as IW/RegulatedAerosolD001, J001 (IGN), D004-43, Listed
FL02Industrial Waste, Flammable Debris, Contaminated with Common Solvents, Shreddable, e.g., absorbents, rags, PCP wood. No Free Liquids, No large metal, rock, or masonry components; Managed as IW/RegulatedVariousD001, J001, D004-43, Listed
FL03Industrial Waste, Flammable, Liquids/Solids/Sludges/Debris, e.g., ordinary industrial waste, sludge, absorbents, lubricants, adhesives, rags, filters, PPE, non-reactive paint waste with isocyanates, Managed as IW/Regulated.VariousD001, J001, D004-43, Listed
FL04Waste Flammable and Corrosive Liquids/Solids/Sludges/Debris, pH 2.1 - 12.4, Contaminated with Volitile Organic Compounds, (VOC) and other halogentated solvents. Managed as Regulated.VariousD001, J001 (IGN), D002, D004-43, Listed
FL05Waste Oil, Flammable Liquids Only, Pumpable for fuels blending, May include JEGS or GOJ designated hazardous substances. Managed as Regulated.LiquidD001, J001 (IGN), D004-43, Listed
FL06Waste Oil, Flammable Liquids Only, Pumpable for fuels blending, No heavy metals, May include JEGS or GOJ designated hazardous substances. Managed as Regulated.LiquidD001, J001 (IGN), D004-43, Listed
FL07Flammable Liquids, Pumpable, Lean to Rich, >2,500 BTU/Lb, 5-10% Total ChlorineLiquidD001, J001 (IGN), D004-43, Listed
FL08Flammable Resuspendable Solids/Sludges, Rich, >7,000 BTU/Lb, <5% Total ChlorineVariousD001, J001 (IGN), D004-43, Listed
FL09Flammable Resuspendable Solids/Sludges, Lean, 2,500-7,000 BTU/Lb, <5% Total ChlorineVariousD001, J001 (IGN), D004-43, Listed
FL10Flammable Resuspendable Solids/Sludges, Lean to Rich, >2,500 BTU/Lb, 5-10% Total ChlorineVariousD001, J001 (IGN), D004-43, Listed
FL11Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.LiquidD001, J001 (IGN), D004-43, Listed, Universal Waste
FL12Sludge, Flammable, Containing High VOC, Chlorinated (>10%) and Halogenated solvents, Insecticides, Herbicides, Fungacides and Pesticides. JEGS or GOJ Regulated, No PCBs, Dioxins, Furans, or Precursors. Managed as Regulated.VariousD001, J001 (IGN), D004-43, Listed, Universal Waste
FL13Sludge, Oxidizers, Non-Reactive, other than chromic acid (see Corrosives), Liquids/Sludges/Solids/Debris, May contain JEGS or GOJ Regulated, Managed as IW / Regulated.VariousD001, J001(OX), D002, J002, D004-43, Listed
FL14Paints, Loose-Packed, Oil-Based, and Paint-Related Materials, >2,500 BTU/Lb. No Isocyanates (See Base CLIN NR06 for 100% Latex)VariousD001, J001 (IGN), D004-43, Listed
FL15Water Contaminated with Solvents, Pumpable, <2,500 BTU/LbLiquidD001, J001 (IGN), D004-43, Listed
FL40Waste Reagents and Chemicals. RegulatedVarious
FL41Waste Reagents and Chemicals. IWVarious
FL99Military Items, Demil-Required, Flammable Solids/Liquids/Debris, i.e. CDE Kits, Vials, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.Various
Lab Packs / Loose Packs (Over-packed Small Containers < pint to ≤ 5GL)
LP01Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.VariousD002, J002, D004-11, Listed Corrosives
LP02Lab Packs/Loose Packs, Mercury, Elemental Liquid.VariousD004-11, Listed Inorganics
LP03Lap Packs/Loose Packs, Flammables and Flammable Corrosives other than Paints eligible for FL14.VariousD001, J001, D002, J002, D004-43, Listed Flammables
LP04Lab Packs/Loose Packs, Non-Regulated Industrial Waste, other than Water-Based paints (Latex).VariousN/A
LP05Lab Packs/Loose Packs, Non-Reactive Oxidizers.VariousD001 (OX), D002, J002, D004-11, Listed
LP06Lab Packs/Loose Packs, Reactive Oxidizers, Includes Organic Peroxides, Special Packaging May Be Required.VariousD001, J001 (Oxidizer), D002, J002, D004-11, Listed
LP07Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, Includes Broken Sodium Lamps and MRE heaters. Special Packaging May Be Required.VariousD001, J001, D003-11, Listed
LP08Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing. Special Packaging May Be Required.VariousD001, J001 D004-43, Listed
LP09Lab Packs/Loose Packs, Toxic Metals.VariousD004-11, Listed Inorganics
LP10Lab Packs/Loose Packs, Toxic Organics.VariousD004-43, Listed
LP11Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, including listed pharmaceuticals. Allows for packaging with U-Listed waste.
VariousD004-43, Listed
LP12Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals.VariousD004-43, U-Listed Codes Only
LP13Lab Packs/Loose Packs, Pesticides.Various
Non-Regulated
NR01Non-RCRA Solids, Direct Landfill Ready. No Free Liquids. Non-Cumbustible Ordinary Industrial Wastes.Solid
NR02Non-Dispersal Asbestos, Non-Friable Asbestos Containing Materials, ≥0.1% asbestos by weight. Other than Regulated waste, Special Packaging Required. No Free Liquids. Managed as IW/Regulated. (See RG01 for dispersable asbestos)Solid
NR03Non-Regulated Liquids, Aqueous (Water based). Wastewater treatment and discharge.Liquid
NR04Non-Regulated Liquids, Pumpable, Organic-Based, i.e., primarily consisting of compound(s) containing hydrocarbons.Liquid
NR06Sludge, Loose-Packed Paints, including 100% Water-Based, e.g., Latex.Various
NR07Unused Pharmaceutical Materials for Thermal Destruction.Various
NR11Sludge, Industrial Waste, Combustible Solids for Waste-To-Energy (WTE) Disposal. May contain some free liquids.Various
NR40Petroleum contaminated soils, Managed as Non-Regulated.Various
NR79Sludge, Industrial Waste,Solids, POL-Contaminated Items, e.g., Pads, Rags, Booms, Sweepables, etc. Contractor returns empty drums to Generator for reuse.Solid
NR91AFFF-Contaminated Solids/Sludges/Debris for Incineration, e.g., Soil, PPE, Filter Media, Empty Containers, May contain some free liquids. Certificate of Disposal/ Destruction Required.Various
NR93AFFF Concentrate Liquid for Incineration, Unused or >10% AFFF Product, Pumpable. Containing PFOA/PFOS. Certificate of Disposal/Destruction Required.Liquid
NR94AFFF Rinsate/Water-Diluted Liquid for Incineration, Used or >90% Water, Pumpable. Containing PFOA/PFOS. Certificate of Disposal/Destruction Required.Liquid
NR95Non-Regulated Electron Tubes for Demil and Disposal. Certificate of Disposal/ Destruction Required.Solid
NR96Non-Regulated Liquids for Incineration, Pumpable.Liquid
NR97Non-Regulated Industrial Waste, Solids/Sludges/Debris for Incineration. May contain some free liquids.Various
NR98Non-Regulated Military Articles, Demil-Required, e.g., Boots, Gloves, CDE Kits, Filters, Masks, MOPP Suits, etc. Certificate of Disposal/ Destruction Required. No Uniforms or Submarine Tiles.Various
PCB-Related ** DO NOT APPLY TO REGIONAL CONTRACTS
PC01PCB and PCB/RCRA-Mixed Waste Contaminated with or Containing >50 ppm Source, i.e. Debris, Sludge, Water, Leaking Capacitors, Fluids other than Transformer Mineral Oil. Certificate of Destruction Required.Various
PC02PCB Mineral Oil from Transformers, 1-49 ppm PCBs, Non-RegulatedLiquid
PC03PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs. Non-Regulated, Certificate of Recycling or Destruction Required.Liquid
PC04PCB Mineral Oil , Water, Other Fluids, >4,000 ppm PCBs. Certificate of Destruction Required.Liquid
PC05PCB Oil-Filled Capacitors/Equipment other than Transformers, 1-49 ppm PCBs, Non-RegulatedVarious
PC06PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, >50 ppm PCBs, INon-Regulated, Certificate of Recycling or Destruction Required.Various
PC07PCB Oil-Filled Transformers, 1-49 ppm PCBs, Non-Regulated.Various
PC08PCB Oil-Filled Transformers, >50 ppm PCBs. Certificate of Recycling or Destruction Required.Various
PC09PCB Solids/Debris Contaminated with 1-49 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-RegulatedSolid
PC10PCB Solids/Debris Contaminated with >50 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-Regulated. Certificate of Disposal, Recycling or Destruction Required.Solid
Recycle/Recovery
RE01C7Sludge, Lamps, Fluorescent, Intact, Linear, CFLs, U-Bent, and Circulars. Intact. Managed as Regulated.SolidIndustrial Waste D004-11
RE02Sludge, Crushed/Broken Lamps, Fluorescent, with Filters and debris.SolidIndustrial Waste D004-11
RE03Sludge, Lamps, Halogen (May include broken lamps)SolidIndustrial Waste D004-11
RE04Sludge, Lamps, High Intensity Discharge (HID), Light Emitting Diode (LED) (May include broken lamps)SolidIndustrial Waste D004-11
RE05Sludge, Lamps, Mercury/Mercury Vapor (May include broken lamps)SolidIndustrial Waste D004-11
RE06Sludge, Lamps, Metal Halide and Metal Hydride, including Sodium (May include broken lamps)SolidIndustrial Waste D003-11
RE07Sludge, Mercury, High, COD Vials, Nessler's Reagent, Chemicals and Residues, Hg>15 mg/Kg Hg<1000 mg/kgVariousIndustrial Waste D002, D004-11
RE08Sludge, Mercury, High, Unused Dental Amalgams, Debris & Residues, Hg >15 mg/Kg. Managed as Regulated. May container Silver and Mercury.VariousIndustrial Waste D004-11
RE09Sludge, Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg>1000 mg/Kg. i.e. Elemental Mercury Only.VariousIndustrial Waste D004-11
RE10Waste Oil, Antifreeze, Used and Unused for Recycling or Fuels Blending. Managed as Non-Regulated. Certificate of Recycle Required.LiquidIndustrial Waste D004-11
RE11Used Oil, <10% Water, <1,000 ppm Total Organic Halides. For Recycling or Fuels Blending, Waste to Energy.LiquidIndustrial Waste D004-11
RE12Used Oil, >10% Water, <1,000 ppm Total Organic Halides. For Recycling or Fuels Blending, Waste to Energy.LiquidIndustrial Waste D004-11
RE13Sludge, Used Oil Filters, Drained and Undrained, and/or Fully Drained Fuel Filters. Certificate of Recycle Required.VariousIndustrial Waste D004-11
RE79Sludge, Sandblast media for recycling. Managed as IW.Solid
GOJ Regulated Wastes
RG01Waste Dispersable/Friable Asbestos, Building Maintenance ACM, GOJ Regulated, Special Packaging Required. No Free Liquids. Managed as Regulated.Solid
RG02Waste Non-Dispersable/Non-Friable Asbestos, Building Maintenance ACM, GOJ Regulated, Special Packaging Required. No Free Liquids. Managed as Regulated.Solid
RG03Petroleum Contaminted Soils with heavy metals, Magaged as RegulatedSolid
Reactive
RX02Sludge, Cyanide,>50% Debris, >590 mg/Kg Total CN

DMK0016: DMK0016:

VariousD002, J002, D004-11, Listed
RX03Sludge, Cyanide, <50% Debris, (1%) Total CNVariousD002, J002, D004-11, Listed
RX04Sludge, Cyanide, <50% Debris, 1%-10% Total CNVariousD002, J002, D004-11, Listed
RX05Sludge, Cyanide, <50% Debris, >10% Total CNVariousD002, J002, D004-11, Listed
RX06Sludge, Reactive Oxidizers, e.g., Nitrates, Nitrites, Persulfates, Inorganic Peroxides, No Organic PeroxidesVariousD001, J001, D003, J003, D004-11, Listed
RX07Sludge, Polymerizing Materials, e.g, Styrene, Isocyanates, AcrylatesVariousD001, J001, D003, J003, D004-11, Listed
RX08Sludge, Reactive Metals, e.g., Powders, Dusts, Fines. Air/Water Reactive. Shipped Under Oil and/or Special Packaging May Be required.SolidD001, J001, D003, J003, D004-11, Listed
RX09Reactive Metals, Debris. Air/Water Reactive. Shipped Under Oil and/or Special Packaging May Be Required.SolidD001, J001, D003, J003, D004-11, Listed
RX10Sludge, Reactive Non-Metals, e.g., P-Coded, Temperature Sensitive, PIHs, Air/Water Reactive.VariousD001, J001, D003, J003, D004-11, Listed
RX40Sludge, Liquids, Organic/Inorganic Peroxides. Managed as Regulated.Various
RX95Sludge, Reactive, Ignitable, and Toxic Solids, e.g., tank bottoms, sludge, and/or debris for Thermal Destruction. Contaminated with Mineral Spirits, Motor Oil, Alcohol, Solvents, and Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.SolidD001, J001, D003, J003, D004-11, Listed
RX97Sludge, Reactive, Ignitable, and Toxic Liquid for Thermal Destruction. Contains Water, Mineral Spirits, Motor Oil, Alcohol, Solvents, and Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total Metals.LiquidD001, J001, D003, J003, D004-11, Listed
RX98Sludge, OBA Cannisters, EEBD and Oxygen Candles, Potentially Reactive, Spent and/or Unspent. Special packaging may be required.SolidD001, J001, D003, J003, D004-11
RX99Military Items, Demil-Required, Reactive, Must Carry D003, Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. (No Batteries) for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.VariousD001, J001, D002, J002, D003, J003, D004-D043, Listed
Toxic
TX01Chromium, Hexavalent, <1% Cr+6, Characteristic Liquids, Solids, SludgesVariousD001, J001, (Oxidizer), D004-11
TX02Chromium, Hexavalent, 1-10% Cr+6, Characteristic Liquids, Solids, SludgesVariousD001, J001, (Oxidizer), D004-11
TX03Chromium, Hexavalent, >10% Cr+6, Characteristic Liquids, Solids, SludgesVariousD001, J001, (Oxidizer), D004-11
TX04Chromium, Hexavalent, <1% Cr+6, Listed Liquids, Solids, SludgesVariousD004-11, F006-12, F019
TX05Chromium, Hexavalent, Wastewater, Pumpable, <1% Total MetalsLiquidD004-11, Listed Inorganics
TX06Debris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. No free liquids unless incidental rainwater/condensation (See TX20).VariousD004-11, Listed Inorganics
TX07Debris, Organic and/or Inorganic Constituents. >50% Debris by volume, >60 mm (~2.5") Particle size. Total VOCs <500 ppm. No free liquids unless incidental rainwater/condensation (see TX20).VariousD004-43, Listed, but no F020-32.
TX08Dioxins, Furans, and Precursors. Liquids, Solids, Sludges, Debris.VariousD004-43, Listed
TX09High Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides, Characteristic/ListedVariousD004-43, Listed, Industrial Waste
TX10Metals in Wastewater, <5% Suspended Solids, <1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/ListedLiquidD004-11, Listed Inorganics
TX11Metals in Wastewater, <5% Suspended Solids, >1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/ListedLiquidD004-11, Listed Inorganics
TX12Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, CharacteristicLiquidD004-11
TX13Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, ListedLiquidD004-11, Listed
TX14Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, CharacteristicLiquidD004-11
TX15Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, ListedLiquidD004-11, Listed
TX16Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, CharacteristicVariousD004-11
TX17Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, ListedVariousD004-11, Listed Inorganics
TX18Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, CharacteristicVariousD004-11
TX19Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, ListedVariousD004-11, Listed
TX20Metals-Bearing Debris/Solids/Sludges with Free Liquids, Contains JEGS/GOJ Characteristic/ListedVariousD004-11, Listed
TX21Organics Contaminated Water, Pumpable, <10% Suspended Solids, <10% Organics, e.g., Toluene, Phenol in water. Not more toxic than common solvents.LiquidD004-43, Listed
TX22Organics or Inorganics in Solids/Sludges/Debris, i.e. Tank & Still Bottoms, Filtercake. Not more toxic than common solvents.VariousD004-43, Listed
TX24Organic Solvents, Technical Grade Pure or Mixed Solutions, With or Without Water and/or Metals, Pumpable, Flashpoint ≥140°F.
LiquidD004-43, Listed
TX97Toxic Electron Tubes for Demil and Disposal, Intact, Certificate of Disposal/Destruction Required.SolidD004-11
TX98Military Items, Demil-required, RCRA Toxic, i.e. CDE Kits, Tents, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.VariousD004-43, Listed
TX99Military Submarine Tiles, Demil-Required via Incinerator. Use this CLIN even when no toxic Waste Codes apply. Certificate of Destruction Required.SolidD004-11

Suffix Table

Containerized Waste Units
CLIN Suffix→C1C2C3C4C5C6C7
Container Size/Type0-5 Gal
DM/DF6-15 Gal
DM/DF16-30 Gal
DM/DF31-55 Gal
DM/DF56-95 Gal
DM/DFCYB, TRIWALL or PALLETContainerized Pounds
(U/M)(EA)(EA)(EA)(EA)(EA)(EA)(LB)
Bulk Waste Units
CLIN Suffix→B1B2B3B4B5B6
Bulk Load DescriptionHeavy Bulk Solids (>600 Lbs/Yd3)
Priced per Lb, Based on Bulk Loads that are…Bulk Pumpable LiquidsLightweight Bulk Solids

(<600 Lbs/Yd3)

(U/M)<10,000 Lbs
(LB)10K-20K Lbs
(LB)20K-30K Lbs
(LB)>30,000 Lbs
(LB)Gallons*
(GL)Cubic Yds*

(CD)

Notes:Weights shown above are net weights of actual waste per bulk load.
Not to be used for lightweight solids weighing less than 600 Lbs per cubic yard.*Light Load Surcharges Apply*Min. Load Volumes Apply
Miscellaneous Units
CylindersLectureSmallMediumLarge
CLIN Suffix→MEM1M2M3
Size Up To:3" x 12"4" x 24"12" x 36"16" x 56"
(U/M)(EA)(EA)(EA)(EA)
Container Size: Hybrid Schedule1 Quart1.25 Gal2.5 Gal3.5 Gal
CLIN Suffix→MEM1M2M3
Type:DM/DFDM/DFDM/DFDM/DF
(U/M)(EA)(EA)(EA)(EA)
CLIN Suffix ME (Miscellaneous Each) also has other applications.

CONUS Cylinder PBC CY01 Compressed Gas Cylinders/Cartridges Cylinders, Category 1, for Disposal/Recycle/Reuse. Comp. Gas See Compressed Gas Cross-Reference List CY02 Compressed Gas Cylinders/Cartridges Cylinders, Category 2, for Disposal/Recycle/Reuse. Comp. Gas See Compressed Gas Cross-Reference List CY03 Compressed Gas Cylinders/Cartridges Cylinders, Category 3, for Disposal/Recycle/Reuse. Comp. Gas See Compressed Gas Cross-Reference List CY04 Compressed Gas Cylinders/Cartridges Cylinders, Category 4, for Disposal/Recycle/Reuse. Comp. Gas See Compressed Gas Cross-Reference List CY05 Compressed Gas Cylinders/Cartridges Cylinders, Category 5, for Disposal/Recycle/Reuse. Comp. Gas See Compressed Gas Cross-Reference List CY06 Compressed Gas Cylinders/Cartridges Cylinders, Category 6, for Disposal/Recycle/Reuse. Comp. Gas See Compressed Gas Cross-Reference List CY07 Compressed Gas Cylinders/Cartridges Cylinders, Category 7, for Disposal/Recycle/Reuse. Comp. Gas See Compressed Gas Cross-Reference List CY08 Compressed Gas Cylinders/Cartridges Cylinders, Category 8, for Disposal/Recycle/Reuse. Comp. Gas See Compressed Gas Cross-Reference List

CY09Compressed Gas Cylinders/CartridgesCylinders, Acetylene, Contains Asbestos, for Purge and Landfill.Comp. GasD001
CY10Compressed Gas Cylinders/CartridgesCylinders, Acetylene, for Recycle/Reuse.Comp. GasD001
CY11Compressed Gas Cylinders/CartridgesCylinders, Propane, 20-Lb "Grill Size", for Disposal, Recycle, or Reuse. Typically 13" x 17". "ME" = 1 EA Grill-Size CylinderComp. GasD001
CY12Compressed Gas Cylinders/CartridgesCartridges, Flammable Gas, AVGAS, Gas/Diesel Starting, for Disposal/Recycle. Diameter up to 3", Length up to 10"Comp. GasD001
CY13Compressed Gas Cylinders/CartridgesCartridges, Inert Gas, for Disposal/Recycle/Reuse. Diameter up to 1", Length up to 6". "ME" = 1 EA CartridgeComp. GasN/A

Compressed Gas Cross Reference

Compressed Gas Description v.2, 26Mar2013Base CLIN
ACETALDEHYDECY02
ACETONECY02
ACETONITRILECY02
ACETYL CHLORIDECY04
ACETYL FLUORIDECY04
ACETYLENECY09/CY10
ACROLEIN INHIBITEDCY07
ACRYLOFUME (ACRYLONITRILE)CY04
AIRCY01
ALANE DIMETHYLETHYAMINE SOLUTIONCY06
ALLENE (PROPADIENE)CY02
ALLYL MAGNESIUM BROMIDECY06
ALLYL MAGNESIUM CHLORIDECY06
ALLYL TRICHLORO SILANECY06
ALLYLAMINECY04
ALLYLENECY02
ALPHA OLEFIN C4CY02
ALUMINUM CHLORIDECY04
ALUMINUM TRICHLORIDECY03
AMINOPROPANE (ISOPROPYLAMINE)CY03
AMMONIACY03
ANILINECY04
ANTIMONY PENTACHLORIDECY04
ANTIMONY PENTACHLORIDE CATALYSTCY07
ANTIMONY PENTAFLUORIDECY04
ANTIMONY TRIBROMIDECY04

This is the start of the file's text. The full file is on GovTribe.